QSQi Shen

Qi Shen

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Qi Shen has a total of 226 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Dual-comb spectroscopy for spatially resolved hydrogen combustion diagnostics over a wide temperature range

    by Meng-Zhe Lian, Wei-Fan Hu, Yu-Xuan Cao, Ming-Ming Gu, Yan Tan, Hao-Wei Liu, You Pang, Lei Hou, Qi Shen, Shui-Ming Hu, et al.

    Dual-comb spectroscopy (DCS) provides exceptional broadband precision for non-intrusive combustion diagnostics. In this work, we present a detailed quantitative reconstruction for laminar hydrogen-air flames across a wide range of thermal conditions, a key regime for advancing clean energy technologies. We employ nonlinear frequency conversion to shift the spectral range of a near-infrared DCS system from the commonly used 1.4 µm region to the optimized 1.34 µm window. This spectral selection significantly reduces environmental interferences and ensures the consistent availability of temperature-sensitive H 2 O absorption features across a wide temperature range. To address the inherent spatial non-uniformity in laminar hydrogen flames, we implement a gradient-aware inversion strategy based on a Boltzmann sigmoidal profile. Coupled with a high-temperature H 2 O spectral database, this approach allows the parametric reconstruction of spatial profiles of temperature and H 2 O mole fraction from single line-of-sight absorption spectra, measured across varying equivalence ratios. The retrieved temperature profiles, within the validated temperature range of the spectroscopic database, show agreement with established reference data within an uncertainty of 50 K. This work establishes a robust DCS framework for hydrogen combustion diagnostics and provides a quantitative reconstruction that will support the development and validation of kinetic models for clean energy applications.

  • Free-space twin-field quantum key distribution

    by Yu-Huai Li, Ting Zeng, Min-Yan Wang, Cong Jiang, Jin Lin, Hao-Bin Fu, Xin-Yang Zheng, Jiu-Peng Chen, Zeng-Sen Lin, Cheng-Lin Li, et al.


  • Low-latency FPGA-based TDC phase detection scheme for optical frequency comb locking

    by Ziqi Wang, Yu Wang, Danyang Zhu, Xiaoning Wang, You Pang, Lei Hou, Jian-Yu Guan, Qi Shen, Haifeng Jiang, Shu-Bin Liu

    Precise phase locking of optical frequency combs requires high-bandwidth feedback to suppress fast phase noise. We present a low-latency digital phase detection scheme based on a high-resolution time-to-digital converter (TDC) implemented in a field-programmable gate array (FPGA). By directly converting signal arrival time into phase error, the total system latency is 115 ns. A digital servo system based on this approach achieves a 1 MHz control bandwidth in voltage-controlled oscillator (VCO) locking. Applied to an erbium-doped fiber frequency comb, the f b e a t locking bandwidth reaches 500 kHz, with a modified Allan deviation of 6.97×10 −18 at 1 s. These results indicate that FPGA-based TDC phase detection enables high-bandwidth and stable optical frequency comb phase locking.

  • Characterization of the phase noise in a cavity-enhanced frequency doubler

    by Mei-Chen Yan, Xing-Yang Cui, Xiao-Dong Lin, De-Quan Kong, Wen-Lan Song, Ping Xu, Qi Shen, Han-Ning Dai

    In optical atomic clocks, the low phase noise of the frequency conversion is essential to maintain the high frequency stability and phase coherence of clock lasers. Higher power of interrogation lasers is required for future optical clocks. In this work, we present a cavity-enhanced frequency doubler based on second harmonic generation with an intra-cavity PPLN crystal. The frequency doubler is highly efficient in obtaining the strontium atomic clock laser from the fundamental laser at 1397 nm. We measure the excess phase noise introduced by the enhancement cavity. The cavity-enhanced frequency doubler introduces excess phase noise with a power spectral density that is nearly an order of magnitude lower than that of state-of-the-art interrogation lasers for offset frequencies between 0.001 Hz and 1 Hz. The modified Allan deviation of fractional frequency instability is 5.3×10 −18 at a 1-second averaging time under a homemade housing. It indicates that the doubler can be used to improve the short-term stability of strontium optical clocks with the best up-to-date ultra-stable lasers. Meanwhile, its high efficiency can match increasing interrogation laser power for further applications.

  • A low-latency digital servo for optical frequency comb stabilization

    by Ziqi Wang, Yu Wang, Danyang Zhu, You Pang, Lei Hou, Qi Shen, Haifeng Jiang, Shubin Liu

    As a fundamental tool in precision spectroscopy and metrology, the optical frequency comb demands exceptional stability and accuracy across diverse applications. Digital servo systems, offering advantages such as low cost and high flexibility, are increasingly employed for optical frequency comb stabilization; however, their performance is constrained by the limited control bandwidth. In this work, we present a low-latency digital servo system designed for optical frequency comb stabilization. The system is implemented on a custom-designed field-programmable gate array-based digital board. Through the optimization of filtering and phase detection algorithms, computational latency is reduced while maintaining precision, enabling a control bandwidth of 1.1 MHz. The repetition rate of the optical frequency comb is locked to a 1560 nm ultra-stable laser. The modified Allan deviation of the measured beat signal, normalized to the optical frequency, is 7.27 × 10−18 at 1 s, thereby validating the performance of the proposed digital servo system.


  • A multi-loop auto-locking system with fully digital electronics for ultra-stable laser

    by Can Xia, DanYang Zhu, Yaodong Hu, ShaoMao Wang, JianYu Guan, Lei Hou, Qi Shen, HaiFeng Jiang

    To achieve high performance ultra-stable laser (USL), multiple locking loops are required to operate simultaneously, including such as Pound–Drever–Hall (PDH), fiber noise cancellation (FNC), and light power stabilization (LPS). In this paper, a highly integrated multi-loop auto-locking system designed for USLs is demonstrated using fully digital electronics. The auto-locking process is implemented using a field programmable gate array with high-speed and high precision analog-to-digital and digital-to-analog converters. The auto-locking system can automatically stabilize the laser carrier frequency or offset sideband frequency to its reference cavity and is capable of successfully relocking within 10 s if interrupted. The fully digital open-loop bandwidth of the fast feedback loop reached 1.3 MHz. The frequency instability of the USL’s frequency in carrier- and offset-locking modes was measured to be 1.5 × 10−15 at 1 s and 2.5 × 10−15 at 1 s, respectively. The contribution of digital electronics to the instability in carrier-locking mode was 2.9 × 10−16 at 1 s, while the noise suppression effect of the digital servo inside the FNC and LPS loops reached 75 and 40 dB at 1 Hz, respectively. The results show that this highly flexible and high-reliability digital auto-locking system can fully satisfy the requirements of USL applications.


  • Top Cited Papers

    Dual-comb spectroscopy over a 100 km open-air path

    by Jin-Jian Han, Wei Zhong, Ruo-Can Zhao, Ting Zeng, Min Li, Jian Lu, Xin-Xin Peng, Xi-Ping Shi, Qin Yin, Yong Wang, et al.


  • Measurement of atmospheric non-reciprocity effects for satellite-based two-way time-frequency transfer

    by Ting Zeng, Qi Shen, Yuan Cao, Jian-Yu Guan, Meng-Zhe Lian, Jin-Jian Han, Lei Hou, Jian Lu, Xin-Xin Peng, Min Li, et al.

    Future optical clock networks will require high-precision optical time-frequency transfer between satellites and ground stations. However, due to atmospheric turbulence, satellite motion and time delay between the satellite–ground transmission links will cause spatial and temporal variations, respectively, resulting in the breakdown of the time-of-flight reciprocity on which optical two-way time-frequency transfer is based. Here, we experimentally simulate the atmospheric effects by two-way spatio-temporally separated links between two stationary terminals located 113 km apart and measure the effects for optical two-way time-frequency transfer. Our experiment shows that the effect on the link instability is less than 2.3×10−19 at 10,000 s. This indicates that when the link instability of satellite–ground optical time-frequency transfer is on the order of 10−19, it is not necessary to consider the atmospheric non-reciprocity effects.


  • Open Access

    The role of USP7-YY1 interaction in promoting colorectal cancer growth and metastasis

    by Zhi-Ying Shao, Wen-Dong Yang, Hui Qiu, Zhi-Hong He, Meng-Ru Lu, Qi Shen, Jin Ding, Jun-Nian Zheng, Jin Bai

    Colorectal cancer (CRC) remains a significant global health issue with high incidence and mortality. Yin Yang 1 (YY1) is a powerful transcription factor that acts dual roles in gene activation and repression. High expression level of YY1 has been reported in CRC, indicating the existence of stable factors of YY1 in CRC cells. We aimed to identify the key molecules and underlying mechanisms responsible for stabilizing YY1 expression in CRC. Mass spectrometry analysis was utilized to identify USP7 as a potential molecule that interacted with YY1. Mechanically, USP7 stabilizes YY1 expression at the protein level by interfering its K63 linkage ubiquitination. YY1 exerts its oncogenic function through transcriptionally activating TRIAP1 but suppressing LC3B. In addition, at the pathological level, there is a positive correlation between the expression of YY1 and the budding of CRC. This study has revealed the intricate interplay between YY1 and USP7 in CRC, suggesting that they could serve as novel therapeutic targets or predictive biomarkers for CRC patients.


  • Increase in the signal-to-noise ratio of the beat note between a frequency comb and a continuous-wave laser

    by Shen Zhang, Qi Shen, Lei Hou, Jian-Yu Guan, Shengkai Liao, Qiang Zhang, Hai-Feng Jiang

    For most comb-based applications, the signal-to-noise ratio (SNR) of the beat note between the comb and the continuous-wave laser is a critical parameter that affects the stability of the system and the accuracy of the measurement. We analyze the SNR model of the beat note and discuss some key aspects of implementing an optimized gated-detection scheme. High-speed balanced detection is introduced to enable detection of more interfering photons, while suppressing optical-intensity-noise interference. The gated detection is achieved by our combining a self-made low-noise, delay-adjustable pulse-generator circuit, which can suppress phase-random white noise. Compared with traditional direct-detection schemes, we demonstrate a 20-dB improvement in performance and achieve a beat-note SNR of more than 60 dB within a 300-kHz resolution bandwidth. Further experiments on frequency-comb locking show that this scheme has high reliability and robustness.