Caroline Mendonca Costa
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Caroline Mendonca Costa has a total of 73 co-authors. Here are the top co-authors by number of shared publications:
- Christopher Aldo Rinaldi
Guy’s and St Thomas’ Hospital & School of Biomedical Engineering and Imaging Sciences, King’s College London Department of Cardiology Westminster Bridge Road, London SE1 7EH
9 shared publications Martin J. Bishop
School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom
7 shared publicationsGernot Plank
Gottfried Schatz Research Center Biophysics, Medical University of Graz, Graz, Austria; BioTechMed-Graz, Graz, Austria
6 shared publications- Gernot Plank
Gottfried Schatz Research Center: Division of Medical Physics and Biophysics, Medical University of Graz, Graz, Austria
6 shared publications Bradley Porter
King's College London, London, United Kingdom
4 shared publications- John Whitaker
School of Biomedical Engineering and Imaging Sciences, King's College, London, United Kingdom
4 shared publications
Latest Publications
- Open Access
- 2 June 2023
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 25 (6)
Additional coils mitigate elevated defibrillation threshold in right-sided implantable cardioverter defibrillator generator placement: a simulation study
The standard implantable cardioverter defibrillator (ICD) generator (can) is placed in the left pectoral area; however, in certain circumstances, right-sided cans may be required which may increase defibrillation threshold (DFT) due to suboptimal shock vectors. We aim to quantitatively assess whether the potential increase in DFT of right-sided can configurations may be mitigated by alternate positioning of the right ventricular (RV) shocking coil or adding coils in the superior vena cava (SVC) and coronary sinus (CS). A cohort of CT-derived torso models was used to assess DFT of ICD configurations with right-sided cans and alternate positioning of RV shock coils. Efficacy changes with additional coils in the SVC and CS were evaluated. A right-sided can with an apical RV shock coil significantly increased DFT compared to a left-sided can [19.5 (16.4, 27.1) J vs. 13.3 (11.7, 19.9) J, P < 0.001]. Septal positioning of the RV coil led to a further DFT increase when using a right-sided can [26.7 (18.1, 36.1) J vs. 19.5 (16.4, 27.1) J, P < 0.001], but not a left-sided can [12.1 (8.1, 17.6) J vs. 13.3 (11.7, 19.9) J, P = 0.099). Defibrillation threshold of a right-sided can with apical or septal coil was reduced the most by adding both SVC and CS coils [19.5 (16.4, 27.1) J vs. 6.6 (3.9, 9.9) J, P < 0.001, and 26.7 (18.1, 36.1) J vs. 12.1 (5.7, 13.5) J, P < 0.001]. Right-sided, compared to left-sided, can positioning results in a 50% increase in DFT. For right-sided cans, apical shock coil positioning produces a lower DFT than septal positions. Elevated right-sided can DFTs may be mitigated by utilizing additional coils in SVC and CS. Abbreviations: DFT: defibrillation threshold; SVC: Superior Vena Cava; CS: Coronary Sinus; NS: not significant.
- 2 June 2023
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 25 (6)
Open AccessAdditional coils mitigate elevated defibrillation threshold in right-sided implantable cardioverter defibrillator generator placement: a simulation study
The standard implantable cardioverter defibrillator (ICD) generator (can) is placed in the left pectoral area; however, in certain circumstances, right-sided cans may be required which may increase defibrillation threshold (DFT) due to suboptimal shock vectors. We aim to quantitatively assess whether the potential increase in DFT of right-sided can configurations may be mitigated by alternate positioning of the right ventricular (RV) shocking coil or adding coils in the superior vena cava (SVC) and coronary sinus (CS). A cohort of CT-derived torso models was used to assess DFT of ICD configurations with right-sided cans and alternate positioning of RV shock coils. Efficacy changes with additional coils in the SVC and CS were evaluated. A right-sided can with an apical RV shock coil significantly increased DFT compared to a left-sided can [19.5 (16.4, 27.1) J vs. 13.3 (11.7, 19.9) J, P < 0.001]. Septal positioning of the RV coil led to a further DFT increase when using a right-sided can [26.7 (18.1, 36.1) J vs. 19.5 (16.4, 27.1) J, P < 0.001], but not a left-sided can [12.1 (8.1, 17.6) J vs. 13.3 (11.7, 19.9) J, P = 0.099). Defibrillation threshold of a right-sided can with apical or septal coil was reduced the most by adding both SVC and CS coils [19.5 (16.4, 27.1) J vs. 6.6 (3.9, 9.9) J, P < 0.001, and 26.7 (18.1, 36.1) J vs. 12.1 (5.7, 13.5) J, P < 0.001]. Right-sided, compared to left-sided, can positioning results in a 50% increase in DFT. For right-sided cans, apical shock coil positioning produces a lower DFT than septal positions. Elevated right-sided can DFTs may be mitigated by utilizing additional coils in SVC and CS. Abbreviations: DFT: defibrillation threshold; SVC: Superior Vena Cava; CS: Coronary Sinus; NS: not significant.
- Open Access
- 26 May 2022
- Published by Elsevier in Medical Image Analysis
- Vol. 80, 102483
An automated near-real time computational method for induction and treatment of scar-related ventricular tachycardias
- 26 May 2022
- Published by Elsevier in Medical Image Analysis
- Vol. 80, 102483
Open AccessAn automated near-real time computational method for induction and treatment of scar-related ventricular tachycardias
- Open Access
- 1 February 2022
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 141, 105061
Determining anatomical and electrophysiological detail requirements for computational ventricular models of porcine myocardial infarction
- 1 February 2022
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 141, 105061
Open AccessDetermining anatomical and electrophysiological detail requirements for computational ventricular models of porcine myocardial infarction
- Open Access
- 1 December 2021
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 139, 104987
An in-silico assessment of efficacy of two novel intra-cardiac electrode configurations versus traditional anti-tachycardia pacing therapy for terminating sustained ventricular tachycardia
- 1 December 2021
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 139, 104987
Open AccessAn in-silico assessment of efficacy of two novel intra-cardiac electrode configurations versus traditional anti-tachycardia pacing therapy for terminating sustained ventricular tachycardia
- Open Access
- 30 December 2020
- Published by Computing in Cardiology
Modelling the Effects of Conductive Polymers and Stem Cells Derived Myocytes on Scarred Heart Tissue
- 30 December 2020
- Published by Computing in Cardiology
Open AccessModelling the Effects of Conductive Polymers and Stem Cells Derived Myocytes on Scarred Heart Tissue
- 28 August 2020
- Published by Elsevier
- p. 453-461
Building Models of Patient-Specific Anatomy and Scar Morphology from Clinical MRI Data
- 28 August 2020
- Published by Elsevier
- p. 453-461
Building Models of Patient-Specific Anatomy and Scar Morphology from Clinical MRI Data
- Open Access
- 1 August 2020
- Published by Elsevier in Heart Rhythm
- Vol. 17 (8) , 1262-1270
Left ventricular endocardial pacing is less arrhythmogenic than conventional epicardial pacing when pacing in proximity to scar
- 1 August 2020
- Published by Elsevier in Heart Rhythm
- Vol. 17 (8) , 1262-1270
Open AccessLeft ventricular endocardial pacing is less arrhythmogenic than conventional epicardial pacing when pacing in proximity to scar
- 1 June 2020
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 22 (Supplement)
P532Endocardial pacing is less arrhythmogenic than conventional epicardial pacing when pacing in proximity to scar in patients with ischemic heart failure
Funding Acknowledgements: WT 203148/Z/16/Z; MR/N011007/1; RE/08/003; PG/15/91/31812; PG/16/81/32441 Background: Endocardial pacing has been shown to improve response to cardiac resynchronization therapy (CRT) in comparison to conventional epicardial pacing and the physiological activation, endocardium to epicardium, is proposed to make it less arrhythmogenic. However, the relative arrhythmic risk of endocardial and epicardial pacing has not been systematically investigated. Pacing in proximity to scar increases susceptibility to arrhythmogenesis during epicardial pacing. Whether this is also the case during endocardial pacing is currently unknown. Purpose: We investigate 1) whether endocardial pacing is less arrhythmogenic than epicardial pacing, 2) whether pacing location relative to scar plays a role in arrhythmogenesis during endocardial pacing, and 3) whether these findings could be explained by the direction of the transmural action potential duration (APD) gradient. Methods: We used computational models of ischemic heart failure and patient-specific (n = 24) left ventricular anatomy and scar morphology to simulate repolarization during endocardial and epicardial pacing. Pacing locations were selected 0.2-3.5cm from a scar. We ran simulations with a 20ms transmural APD gradient, as found in heart failure, from the epicardium to endocardium (physiological) and with this gradient inverted. We computed the volume of high (>3ms/mm) repolarization gradients (HRG) within 1cm around a scar, as a surrogate for arrhythmia risk, and analysed these with ANOVA and Tukey-Kramer post-hoc tests. Results: Simulations with a physiological APD gradient predict that endocardial pacing creates a smaller (34%) volume of HRG around (1cm) a scar compared to epicardial pacing when pacing 0.2cm from scar (Figure 1-A). The volume of HRG decreases (P < 0.05) with distance from scar for epicardial pacing but not endocardial pacing (Figure 1-A). Inverting the transmural APD gradient, inverts the trend observed with a physiological gradient. In this case, the volume of HRG is unaffected by pacing location during epicardial pacing, whereas it decreases (19%) with the distance from scar for endocardial pacing. This is illustrated in the regions highlighted in yellow in Figure 1 for endocardial pacing at 0.2 and 3.5cm from a scar with a physiological (B) and an inverted (C) gradient. Conclusions: Endocardial pacing is less arrhythmogenic (purpose 1) than conventional epicardial pacing when pacing in proximity to scar and is also less susceptible to pacing location relative to scar (purpose 2). The direction of the transmural APD gradient offers a mechanistic explanation for reduced susceptibility to arrhythmogenesis during endocardial pacing compared to epicardial pacing (purpose 3). Endocardial pacing is an attractive alternative to conventional epicardial pacing in patients with scar, as it allows pacing in proximity to scar while avoiding increasing arrhythmogenic risk in patients with ischemic heart failure. Abstract Figure.
- 1 June 2020
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 22 (Supplement)
P532Endocardial pacing is less arrhythmogenic than conventional epicardial pacing when pacing in proximity to scar in patients with ischemic heart failure
Funding Acknowledgements: WT 203148/Z/16/Z; MR/N011007/1; RE/08/003; PG/15/91/31812; PG/16/81/32441 Background: Endocardial pacing has been shown to improve response to cardiac resynchronization therapy (CRT) in comparison to conventional epicardial pacing and the physiological activation, endocardium to epicardium, is proposed to make it less arrhythmogenic. However, the relative arrhythmic risk of endocardial and epicardial pacing has not been systematically investigated. Pacing in proximity to scar increases susceptibility to arrhythmogenesis during epicardial pacing. Whether this is also the case during endocardial pacing is currently unknown. Purpose: We investigate 1) whether endocardial pacing is less arrhythmogenic than epicardial pacing, 2) whether pacing location relative to scar plays a role in arrhythmogenesis during endocardial pacing, and 3) whether these findings could be explained by the direction of the transmural action potential duration (APD) gradient. Methods: We used computational models of ischemic heart failure and patient-specific (n = 24) left ventricular anatomy and scar morphology to simulate repolarization during endocardial and epicardial pacing. Pacing locations were selected 0.2-3.5cm from a scar. We ran simulations with a 20ms transmural APD gradient, as found in heart failure, from the epicardium to endocardium (physiological) and with this gradient inverted. We computed the volume of high (>3ms/mm) repolarization gradients (HRG) within 1cm around a scar, as a surrogate for arrhythmia risk, and analysed these with ANOVA and Tukey-Kramer post-hoc tests. Results: Simulations with a physiological APD gradient predict that endocardial pacing creates a smaller (34%) volume of HRG around (1cm) a scar compared to epicardial pacing when pacing 0.2cm from scar (Figure 1-A). The volume of HRG decreases (P < 0.05) with distance from scar for epicardial pacing but not endocardial pacing (Figure 1-A). Inverting the transmural APD gradient, inverts the trend observed with a physiological gradient. In this case, the volume of HRG is unaffected by pacing location during epicardial pacing, whereas it decreases (19%) with the distance from scar for endocardial pacing. This is illustrated in the regions highlighted in yellow in Figure 1 for endocardial pacing at 0.2 and 3.5cm from a scar with a physiological (B) and an inverted (C) gradient. Conclusions: Endocardial pacing is less arrhythmogenic (purpose 1) than conventional epicardial pacing when pacing in proximity to scar and is also less susceptible to pacing location relative to scar (purpose 2). The direction of the transmural APD gradient offers a mechanistic explanation for reduced susceptibility to arrhythmogenesis during endocardial pacing compared to epicardial pacing (purpose 3). Endocardial pacing is an attractive alternative to conventional epicardial pacing in patients with scar, as it allows pacing in proximity to scar while avoiding increasing arrhythmogenic risk in patients with ischemic heart failure. Abstract Figure.
- Open Access
- 3 April 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 67 (11) , 3125-3133
3D Electrophysiological Modeling of Interstitial Fibrosis Networks and Their Role in Ventricular Arrhythmias in Non-Ischemic Cardiomyopathy
Objective: Interstitial fibrosis is a pathological expansion of the heart's inter-cellular collagen matrix. It is a potential complication of nonischemic cardiomyopathy (NICM), a class of diseases involving electrical and or mechanical dysfunction of cardiac tissue not caused by atherosclerosis. Patients with NICM and interstitial fibrosis often suffer from life threatening arrhythmias, which we aim to simulate in this study. Methods: Our methodology builds on an efficient discrete finite element (DFE) method which allows for the representation of fibrosis as infinitesimal splits in a mesh. We update the DFE method with a local connectivity analysis which creates a consistent topology in the fibrosis network. This is particularly important in nonischemic disease due to the potential presence of large and contiguous fibrotic regions and therefore potentially complex fibrosis networks. Results: In experiments with an image-based model, we demonstrate that our methodology is able to simulate reentrant electrical events associated with cardiac arrhythmias. These reentries depended crucially upon sufficient fibrosis density, which was marked by conduction slowing at high pacing rates. We also created a 2D test-case which demonstrated that fibrosis topologies can modulate transient conduction block, and thereby reentrant activations. Conclusion: Ventricular arrhythmias due to interstitial fibrosis in NICM can be efficiently simulated using our methods in medical image based geometries. Furthermore, fibrosis topology modulates transient conduction block, and should be accounted for in electrophysiological simulations with interstitial fibrosis. Significance: Our study provides methodology which has the potential to predict arrhythmias and to optimize treatments non-invasively for nonischemic cardiomyopathies.
- 3 April 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 67 (11) , 3125-3133
Open Access3D Electrophysiological Modeling of Interstitial Fibrosis Networks and Their Role in Ventricular Arrhythmias in Non-Ischemic Cardiomyopathy
Objective: Interstitial fibrosis is a pathological expansion of the heart's inter-cellular collagen matrix. It is a potential complication of nonischemic cardiomyopathy (NICM), a class of diseases involving electrical and or mechanical dysfunction of cardiac tissue not caused by atherosclerosis. Patients with NICM and interstitial fibrosis often suffer from life threatening arrhythmias, which we aim to simulate in this study. Methods: Our methodology builds on an efficient discrete finite element (DFE) method which allows for the representation of fibrosis as infinitesimal splits in a mesh. We update the DFE method with a local connectivity analysis which creates a consistent topology in the fibrosis network. This is particularly important in nonischemic disease due to the potential presence of large and contiguous fibrotic regions and therefore potentially complex fibrosis networks. Results: In experiments with an image-based model, we demonstrate that our methodology is able to simulate reentrant electrical events associated with cardiac arrhythmias. These reentries depended crucially upon sufficient fibrosis density, which was marked by conduction slowing at high pacing rates. We also created a 2D test-case which demonstrated that fibrosis topologies can modulate transient conduction block, and thereby reentrant activations. Conclusion: Ventricular arrhythmias due to interstitial fibrosis in NICM can be efficiently simulated using our methods in medical image based geometries. Furthermore, fibrosis topology modulates transient conduction block, and should be accounted for in electrophysiological simulations with interstitial fibrosis. Significance: Our study provides methodology which has the potential to predict arrhythmias and to optimize treatments non-invasively for nonischemic cardiomyopathies.
- Open Access
- 1 October 2019
- Published by Elsevier in Heart Rhythm
- Vol. 16 (10) , 1475-1483
Pacing in proximity to scar during cardiac resynchronization therapy increases local dispersion of repolarization and susceptibility to ventricular arrhythmogenesis
- 1 October 2019
- Published by Elsevier in Heart Rhythm
- Vol. 16 (10) , 1475-1483
Open AccessPacing in proximity to scar during cardiac resynchronization therapy increases local dispersion of repolarization and susceptibility to ventricular arrhythmogenesis