Vakkas Bozkurt
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Vakkas Bozkurt has a total of 61 co-authors. Here are the top co-authors by number of shared publications:
- Sefa Erturk
Niğde Ömer Halisdemir Üniversitesi
5 shared publications - Anu Kankainen
University of Jyväskylä
2 shared publications B. Roussiere
Université Paris-Saclay
2 shared publicationsC. Gaulard
Université Paris-Saclay
2 shared publications- Clement Delafosse
University of Jyväskylä
2 shared publications D. Thisse
Université Paris-Saclay
2 shared publications
Latest Publications
- 30 July 2026
- Published by Omer Halisdemir Universitesi in Eurasian Journal of Science Engineering and Technology
- Vol. 7 (2) , 62-71
Development of a Portable Integrated Ultrasound and Gamma imaging system
Medical imaging devices that combine both the functional and anatomical modalities have proved to be highly accurate in diagnoses. Nonetheless, current SPECT-CT systems are bulky, very costly, and non-portable, restricting their use for disabled patients. A comparison was carried out using GATE/GEANT4 Monte Carlo simulation for scintillator efficiency. The experimental work used a 4×4 pixel array GAGG(Ce)+SiPM detector with SIB616/SIB1632 readout electronics and IQSP580 DAQ system. Hexagonal and pinhole collimators were thoroughly investigated. Two new algorithms for image fusion were created; these include Dynamic Alpha Blending and US-Protected Adaptive Overlay. The results show the superiority of GAGG(Ce) with 3.196 mm spatial resolution and 4.9% energy resolution, better than LYSO (3.391mm, 8.5%). Images with gamma photons were successfully acquired using phantom Tc-99m breast lesions from distances of 5 to 20 cm. Both dynamic algorithms yielded medically useful images with Method 2 having anatomical information and Method 1 with functional details. The US-SPECT device designed provides a major breakthrough in portable hybrid medical imaging, providing bedside capability for the disabled patients as well as lower radiation doses as compared to CT-based hybrid devices.
- 30 July 2026
- Published by Omer Halisdemir Universitesi in Eurasian Journal of Science Engineering and Technology
- Vol. 7 (2) , 62-71
Development of a Portable Integrated Ultrasound and Gamma imaging system
Medical imaging devices that combine both the functional and anatomical modalities have proved to be highly accurate in diagnoses. Nonetheless, current SPECT-CT systems are bulky, very costly, and non-portable, restricting their use for disabled patients. A comparison was carried out using GATE/GEANT4 Monte Carlo simulation for scintillator efficiency. The experimental work used a 4×4 pixel array GAGG(Ce)+SiPM detector with SIB616/SIB1632 readout electronics and IQSP580 DAQ system. Hexagonal and pinhole collimators were thoroughly investigated. Two new algorithms for image fusion were created; these include Dynamic Alpha Blending and US-Protected Adaptive Overlay. The results show the superiority of GAGG(Ce) with 3.196 mm spatial resolution and 4.9% energy resolution, better than LYSO (3.391mm, 8.5%). Images with gamma photons were successfully acquired using phantom Tc-99m breast lesions from distances of 5 to 20 cm. Both dynamic algorithms yielded medically useful images with Method 2 having anatomical information and Method 1 with functional details. The US-SPECT device designed provides a major breakthrough in portable hybrid medical imaging, providing bedside capability for the disabled patients as well as lower radiation doses as compared to CT-based hybrid devices.
- Open Access
- 23 March 2026
- Published by IOP Publishing in Physica Scripta
- Vol. 101 (12) , 125303
Experimental and Monte Carlo evaluation of a GAGG-BGO phoswich detector using 3D-printed Tc-99m FLUX phantoms
This study presents an experimental and Monte Carlo-based evaluation of a compact GAGG(Ce)-BGO phoswich detector for detector-level Tc-99m imaging. Single-projection measurements obtained with a 4 × 4 detector module demonstrated that simple geometric structures from a 3D-printed phantom can be clearly resolved under collimated acquisition. Experimental images show good qualitative agreement with GATE-based simulations, confirming that the observed image features are primarily governed by detector configuration and source geometry. Spatial resolution analysis yields an intrinsic resolution of 4.3 mm from simulated point-source PSF/LSF and an effective image-based resolution of 5.9 mm derived from ESF/LSF analysis, reflecting additional blurring contributions inherent to image-based measurements. Geant4 simulations indicate a GAGG-to-BGO light output ratio of approximately five, consistent with experimental characterization and GATE-based image mapping. Compared to a reference NaI(Tl) detector, the phoswich configuration exhibits reduced background noise and improved signal-to-noise and contrast-to-noise ratios, highlighting its potential for scalable SPECT detector applications. The validated experimental–simulation framework provides a basis for future detector performance optimization, including depth-of-interaction–assisted image reconstruction and image quality enhancement through alternative collimator geometries and materials.
- 23 March 2026
- Published by IOP Publishing in Physica Scripta
- Vol. 101 (12) , 125303
Open AccessExperimental and Monte Carlo evaluation of a GAGG-BGO phoswich detector using 3D-printed Tc-99m FLUX phantoms
This study presents an experimental and Monte Carlo-based evaluation of a compact GAGG(Ce)-BGO phoswich detector for detector-level Tc-99m imaging. Single-projection measurements obtained with a 4 × 4 detector module demonstrated that simple geometric structures from a 3D-printed phantom can be clearly resolved under collimated acquisition. Experimental images show good qualitative agreement with GATE-based simulations, confirming that the observed image features are primarily governed by detector configuration and source geometry. Spatial resolution analysis yields an intrinsic resolution of 4.3 mm from simulated point-source PSF/LSF and an effective image-based resolution of 5.9 mm derived from ESF/LSF analysis, reflecting additional blurring contributions inherent to image-based measurements. Geant4 simulations indicate a GAGG-to-BGO light output ratio of approximately five, consistent with experimental characterization and GATE-based image mapping. Compared to a reference NaI(Tl) detector, the phoswich configuration exhibits reduced background noise and improved signal-to-noise and contrast-to-noise ratios, highlighting its potential for scalable SPECT detector applications. The validated experimental–simulation framework provides a basis for future detector performance optimization, including depth-of-interaction–assisted image reconstruction and image quality enhancement through alternative collimator geometries and materials.
- 8 October 2025
- Published by American Physical Society (APS) in Physical Review C
- Vol. 112 (4)
-delayed spectroscopy of and competition between Gamow-Teller and first-forbidden transitions in decay- 8 October 2025
- Published by American Physical Society (APS) in Physical Review C
- Vol. 112 (4)
-delayed spectroscopy of and competition between Gamow-Teller and first-forbidden transitions in decay- 4 March 2025
- Published by American Physical Society (APS) in Physical Review C
- Vol. 111 (3)
Simultaneous impacts of nuclear shell structure and collectivity on decay: Evidence from- 4 March 2025
- Published by American Physical Society (APS) in Physical Review C
- Vol. 111 (3)
Simultaneous impacts of nuclear shell structure and collectivity on decay: Evidence from- Open Access
- 15 December 2023
- Published by Omer Halisdemir Universitesi in Eurasian Journal of Science Engineering and Technology
- Vol. 4 (2) , 50-55
THE EXOGAM2 CALIBRATION USING THE NEWLY DEVELOPED NUMEXO2 DIGITAL ELECTRONIC
In this study, the calibration process of the EXOGAM2 conventional gamma detector system with the newly developed digital electronic device, namely NUMEXO2, will be presented. This experimental study was performed at the GANIL (Grand Accélérateur National d'Ions Lourds) nuclear research center in France. The energy calibration of the EXOGAM2 detector system with the newly developed NUMEXO2 digital electronic device was conducted using both low and high gamma energy levels of a 152Eu radioactive source. This calibration was carried out for two EXOGAM2 detectors, and the energy resolution of each crystal in the EXOGAM2 system was determined. The energy resolution of each crystal was found to be reasonable energy resolution values of the EXOGAM2 detectors. Therefore, the use of the digital electronic device NUMEXO2 did not affect the energy resolution of the detectors, but it did enable us to acquire data at a high counting rate.
- 15 December 2023
- Published by Omer Halisdemir Universitesi in Eurasian Journal of Science Engineering and Technology
- Vol. 4 (2) , 50-55
Open AccessTHE EXOGAM2 CALIBRATION USING THE NEWLY DEVELOPED NUMEXO2 DIGITAL ELECTRONIC
In this study, the calibration process of the EXOGAM2 conventional gamma detector system with the newly developed digital electronic device, namely NUMEXO2, will be presented. This experimental study was performed at the GANIL (Grand Accélérateur National d'Ions Lourds) nuclear research center in France. The energy calibration of the EXOGAM2 detector system with the newly developed NUMEXO2 digital electronic device was conducted using both low and high gamma energy levels of a 152Eu radioactive source. This calibration was carried out for two EXOGAM2 detectors, and the energy resolution of each crystal in the EXOGAM2 system was determined. The energy resolution of each crystal was found to be reasonable energy resolution values of the EXOGAM2 detectors. Therefore, the use of the digital electronic device NUMEXO2 did not affect the energy resolution of the detectors, but it did enable us to acquire data at a high counting rate.
- Open Access
- 1 January 2023
- Published by Afyon Kocatepe Universitesi Fen Ve Muhendislik Bilimleri Dergisi in Afyon Kocatepe University Journal of Sciences and Engineering
- Vol. 23 (6) , 1391-1394
Energy Resolution Performance Research for NaI(TI) Detector with NUMEXO2 Digital Electronic
Dedektör sistemleri ile birlikte kullanılan elektronik sistemler, dedektör yapısı ve kullanılan dedektör malzemeleri enerji çözünürlüğü üzerinde etki eden parametrelerdir. Bu çalışmada, deneysel ve uygulamalı nükleer çalışmalarda en çok tercih edilen dedektör sistemi olan Talyum katkılı NaI(Tl) sintilasyon dedektör sisteminin enerji çözünürlüğü performans incelemesi yapılmıştır. Bu araştırmada, yeni geliştirilen 50kHz sayım sayısı limitine sahip olan NUMEXO2 dijital elektronik sistem ile birleştirilen geleneksel NaI(Tl) dedektör sistemi kullanılarak veri alımı yapıldı. Bu çalışmadaki veriler Fransa'daki GANIL araştırma merkezinde gerçekleştirilen deney sonucundan alınıp analizi yapılmıştır. Deneyde kullanılan 60Co radyoaktif kaynağın 1173.2 keV ve 1332.5 keV gama enerji pikleri için NaI(TI) fosfor sandviç detektörün her bir kristalinden elde edilen spektrum, her bir referans enerji pikinin tam genişlik yarı yükseklik-FWHM (Full Width Half Maximum) değerlerini elde etmek için uygun hale getirildi ve her bir NaI(TI) fosfor sandviç dedektörün enerji çözünürlüğü performans incelemesi yapılmıştır.
- 1 January 2023
- Published by Afyon Kocatepe Universitesi Fen Ve Muhendislik Bilimleri Dergisi in Afyon Kocatepe University Journal of Sciences and Engineering
- Vol. 23 (6) , 1391-1394
Open AccessEnergy Resolution Performance Research for NaI(TI) Detector with NUMEXO2 Digital Electronic
Dedektör sistemleri ile birlikte kullanılan elektronik sistemler, dedektör yapısı ve kullanılan dedektör malzemeleri enerji çözünürlüğü üzerinde etki eden parametrelerdir. Bu çalışmada, deneysel ve uygulamalı nükleer çalışmalarda en çok tercih edilen dedektör sistemi olan Talyum katkılı NaI(Tl) sintilasyon dedektör sisteminin enerji çözünürlüğü performans incelemesi yapılmıştır. Bu araştırmada, yeni geliştirilen 50kHz sayım sayısı limitine sahip olan NUMEXO2 dijital elektronik sistem ile birleştirilen geleneksel NaI(Tl) dedektör sistemi kullanılarak veri alımı yapıldı. Bu çalışmadaki veriler Fransa'daki GANIL araştırma merkezinde gerçekleştirilen deney sonucundan alınıp analizi yapılmıştır. Deneyde kullanılan 60Co radyoaktif kaynağın 1173.2 keV ve 1332.5 keV gama enerji pikleri için NaI(TI) fosfor sandviç detektörün her bir kristalinden elde edilen spektrum, her bir referans enerji pikinin tam genişlik yarı yükseklik-FWHM (Full Width Half Maximum) değerlerini elde etmek için uygun hale getirildi ve her bir NaI(TI) fosfor sandviç dedektörün enerji çözünürlüğü performans incelemesi yapılmıştır.
- 16 September 2022
- Published by Springer Nature in Radiation and Environmental Biophysics
- Vol. 61 (4) , 609-614
Evaluation of radon gas concentration in indoor air of spas and in spring water in the central Anatolia region of Turkey
The present study aimed to determine the concentration of radon (222Rn) levels of indoor air of spas and of spring water sites in the Turkish cities of Nigde and Aksaray, both located in Cappadocia, Anatolia, which is a well-known tourist area. In this area there are a lot of spring water and thermal water sites providing both drinking water and water for spas, which are used for therapeutic treatments of diseases and for health services. Therefore, it is necessary to quantify radon gas concentrations in the air of sites that use geothermal waters and spring water. Consequently, radon measurements were carried out using CR-39 detectors placed at different locations within each investigated thermal spa and spring water site. The results obtained indicate that, in the air of spring water at Helvadere, there is a high radon concentration. The average radon concentrations obtained for the air of Ciftehan and Ziga thermal spas were 12.5 ± 1.4 Bq/m3 and 15.5 ± 2.1 Bq/m3, respectively, while in the air of Kemerhisar, Helvadere, and Okcu village spring water sites the average radon concentrations were 32 ± 4.2 Bq/m3, 265 ± 37.9 Bq/m3, and 35 ± 5.1 Bq/m3, respectively. The corresponding average effective doses were calculated both for patients and workers for Ciftehan and Ziga thermal spas, and for workers 0.09 and 0.11 mSv/year for Ciftehan and Ziga, respectively, were obtained. Doses for patients were 0.0007 and 0.0008 mSv/year for Ciftehan and Ziga, respectively. It is concluded that based on the measured radon concentrations and corresponding effective doses no radiation protection measures must be implemented.
- 16 September 2022
- Published by Springer Nature in Radiation and Environmental Biophysics
- Vol. 61 (4) , 609-614
Evaluation of radon gas concentration in indoor air of spas and in spring water in the central Anatolia region of Turkey
The present study aimed to determine the concentration of radon (222Rn) levels of indoor air of spas and of spring water sites in the Turkish cities of Nigde and Aksaray, both located in Cappadocia, Anatolia, which is a well-known tourist area. In this area there are a lot of spring water and thermal water sites providing both drinking water and water for spas, which are used for therapeutic treatments of diseases and for health services. Therefore, it is necessary to quantify radon gas concentrations in the air of sites that use geothermal waters and spring water. Consequently, radon measurements were carried out using CR-39 detectors placed at different locations within each investigated thermal spa and spring water site. The results obtained indicate that, in the air of spring water at Helvadere, there is a high radon concentration. The average radon concentrations obtained for the air of Ciftehan and Ziga thermal spas were 12.5 ± 1.4 Bq/m3 and 15.5 ± 2.1 Bq/m3, respectively, while in the air of Kemerhisar, Helvadere, and Okcu village spring water sites the average radon concentrations were 32 ± 4.2 Bq/m3, 265 ± 37.9 Bq/m3, and 35 ± 5.1 Bq/m3, respectively. The corresponding average effective doses were calculated both for patients and workers for Ciftehan and Ziga thermal spas, and for workers 0.09 and 0.11 mSv/year for Ciftehan and Ziga, respectively, were obtained. Doses for patients were 0.0007 and 0.0008 mSv/year for Ciftehan and Ziga, respectively. It is concluded that based on the measured radon concentrations and corresponding effective doses no radiation protection measures must be implemented.
- Open Access
Eco-Geopolymers: Physico-Mechanical Features, Radiation Absorption Properties, and Mathematical Model
Waste ashes and radiation are hazardous environmental and health factors; thus, a lot of attention is paid to their reduction. We present eco-geopolymer building materials (GPBMs) based on the class F fly ashes (FFAs) from thermal power plants (TPPs) and their implementation as a barrier against radioactive radiation. Different methods of production, ratios of FFA to alkali activator, and temperatures of curing were tested. Small spherical particles and higher content of SiO2 resulted in developed surface area and higher reactivity of Isken TPP FFA than Catalagzi TPP FFA. Lower activator concentration (10% vs. 20%) and curing temperature (70 vs. 100 °C) caused an increase in GPBM compressive strength; the highest value was measured as 93.3 MPa. The highest RA was measured for GPBMs, provided alkali activator ratio (Na2SiO3/NaOH) was >2 and its concentration was 20%. The mathematical model developed in this study proved FFA quantity, and thus GPBM mechanical properties, as key factors influencing RA. In the light of these results, the lightweight GPBMs can be excellent materials for the construction sector dedicated to immobilization, storage, and disposal for radionuclides or barriers against radiation; however, multiple steps of their production require careful optimization.
Open AccessEco-Geopolymers: Physico-Mechanical Features, Radiation Absorption Properties, and Mathematical Model
Waste ashes and radiation are hazardous environmental and health factors; thus, a lot of attention is paid to their reduction. We present eco-geopolymer building materials (GPBMs) based on the class F fly ashes (FFAs) from thermal power plants (TPPs) and their implementation as a barrier against radioactive radiation. Different methods of production, ratios of FFA to alkali activator, and temperatures of curing were tested. Small spherical particles and higher content of SiO2 resulted in developed surface area and higher reactivity of Isken TPP FFA than Catalagzi TPP FFA. Lower activator concentration (10% vs. 20%) and curing temperature (70 vs. 100 °C) caused an increase in GPBM compressive strength; the highest value was measured as 93.3 MPa. The highest RA was measured for GPBMs, provided alkali activator ratio (Na2SiO3/NaOH) was >2 and its concentration was 20%. The mathematical model developed in this study proved FFA quantity, and thus GPBM mechanical properties, as key factors influencing RA. In the light of these results, the lightweight GPBMs can be excellent materials for the construction sector dedicated to immobilization, storage, and disposal for radionuclides or barriers against radiation; however, multiple steps of their production require careful optimization.
- 29 November 2020
- Published by Suleyman Demirel Universitesi Fen Edebiyat Fakultesi Fen Dergisi in Süleyman Demirel Üniversitesi Fen Edebiyat Fakültesi Fen Dergisi
- Vol. 15 (2) , 237-243
Yeni Geliştirilen NUMEXO2 Dijital Elektronik ile EXOGAM2 Dedektörünün K-Parametresine Bağlı Enerji Çözünürlüğü
Bu çalışmada, yeni geliştirilen dijital elektronik NUMEXO2 dijital elektronik ile EXOGAM2(EXOtic GAMma array spectrometer) dedektörünün K-Parametrelerine (sayım oranını optimize eden Trapezoidal filtre sistemi) bağlı enerji çözünürlüğü için 152Eu radyoaktif kaynak kullanılarak ölçüm ve analiz yapılmıştır. Yapılan bu deneysel çalışma Fransa’da bulunan GANIL (Grand Accelerature National d’Ions Lourd) nükleer araştırma merkezinde gerçekleştirilmiştir. Düşük ve yüksek gama enerji seviyesine sahip 152Eu radyoaktif kaynak kullanılarak farklı K-parametreleri için gerçekleştirilen ölçüm ve analiz sonuçları iki EXOGAM2 dedektörü için gerçekleştirilmiştir. Herhangi bir K-parametresi uygulamadan 1.EXOGAM2 dedektörü için FWHM ile ifade edilen çözünürlük değerleri sırası ile (344. 2785 keV) için 2.360% FWHM, (1408.006 keV) için 2.820% FWHM olarak ölçülürken 2.EXOGAM2 dedektörü için ise sırasıyla 2.451% FWHM ve 2.975% FWHM olarak ölçülmüştür. Farklı K-parametreleri (K=2µs, K=5µs ve K=10µs) için ise sonuçlar detayları ile aşağıda gösterilmiştir.
- 29 November 2020
- Published by Suleyman Demirel Universitesi Fen Edebiyat Fakultesi Fen Dergisi in Süleyman Demirel Üniversitesi Fen Edebiyat Fakültesi Fen Dergisi
- Vol. 15 (2) , 237-243
Yeni Geliştirilen NUMEXO2 Dijital Elektronik ile EXOGAM2 Dedektörünün K-Parametresine Bağlı Enerji Çözünürlüğü
Bu çalışmada, yeni geliştirilen dijital elektronik NUMEXO2 dijital elektronik ile EXOGAM2(EXOtic GAMma array spectrometer) dedektörünün K-Parametrelerine (sayım oranını optimize eden Trapezoidal filtre sistemi) bağlı enerji çözünürlüğü için 152Eu radyoaktif kaynak kullanılarak ölçüm ve analiz yapılmıştır. Yapılan bu deneysel çalışma Fransa’da bulunan GANIL (Grand Accelerature National d’Ions Lourd) nükleer araştırma merkezinde gerçekleştirilmiştir. Düşük ve yüksek gama enerji seviyesine sahip 152Eu radyoaktif kaynak kullanılarak farklı K-parametreleri için gerçekleştirilen ölçüm ve analiz sonuçları iki EXOGAM2 dedektörü için gerçekleştirilmiştir. Herhangi bir K-parametresi uygulamadan 1.EXOGAM2 dedektörü için FWHM ile ifade edilen çözünürlük değerleri sırası ile (344. 2785 keV) için 2.360% FWHM, (1408.006 keV) için 2.820% FWHM olarak ölçülürken 2.EXOGAM2 dedektörü için ise sırasıyla 2.451% FWHM ve 2.975% FWHM olarak ölçülmüştür. Farklı K-parametreleri (K=2µs, K=5µs ve K=10µs) için ise sonuçlar detayları ile aşağıda gösterilmiştir.
- 1 December 2018
- Published by Sakarya University Journal of Science in Sakarya University Journal of Science
- Vol. 22 (6) , 1623-1627
The First Indoor Radon Gas Measurement at Historical Places in Cappadocia, Nigde, Turkey
The aim of this study is to determine the concentration of Radon and its annual effective dose at the Nigde Museum and in a number of historical places namely the Sungur Bey, the Alaeddin, the Disari mosque and the Ak Medrese Culture House in Cappadocia, Nigde, Turkey by using a nuclear track detector CR-39 to ascertain how much Radon concentration affects the people who are working in or visiting such places. Nuclear track detectors CR-39 were used for measurement for 132 days at the Nigde Museum, and for 63 days in the historical places. The exposed nuclear track detectors were then sent to the Sarayköy Nuclear Research and Training Center (SANAEM) to determine of Radon-222. The average Radon concentration results obtained for the Nigde Museum, the Sungur Bey, the Alaeddin, the Disari mosques and the Ak Medrese Culture House were 13.0±2.94 Bq/m3, 31.67±3.86 Bq/m3, 52.0±5.72 Bq/m3, 42.67±19.34 Bq/m3 and 31.0±4.55 Bq/m3 respectively. The average effective dose of Radon was calculated for the Nigde Museum, the Sungur Bey, the Alaeddin, the Disari mosques and the Ak Medrese Culture House in Nigde and was found to be approximately 0.137 mSv/y, 0.062 mSv/y, 0.103 mSv/y, 0.084 mSv/y and 0.327 mSv/y respectively
- 1 December 2018
- Published by Sakarya University Journal of Science in Sakarya University Journal of Science
- Vol. 22 (6) , 1623-1627
The First Indoor Radon Gas Measurement at Historical Places in Cappadocia, Nigde, Turkey
The aim of this study is to determine the concentration of Radon and its annual effective dose at the Nigde Museum and in a number of historical places namely the Sungur Bey, the Alaeddin, the Disari mosque and the Ak Medrese Culture House in Cappadocia, Nigde, Turkey by using a nuclear track detector CR-39 to ascertain how much Radon concentration affects the people who are working in or visiting such places. Nuclear track detectors CR-39 were used for measurement for 132 days at the Nigde Museum, and for 63 days in the historical places. The exposed nuclear track detectors were then sent to the Sarayköy Nuclear Research and Training Center (SANAEM) to determine of Radon-222. The average Radon concentration results obtained for the Nigde Museum, the Sungur Bey, the Alaeddin, the Disari mosques and the Ak Medrese Culture House were 13.0±2.94 Bq/m3, 31.67±3.86 Bq/m3, 52.0±5.72 Bq/m3, 42.67±19.34 Bq/m3 and 31.0±4.55 Bq/m3 respectively. The average effective dose of Radon was calculated for the Nigde Museum, the Sungur Bey, the Alaeddin, the Disari mosques and the Ak Medrese Culture House in Nigde and was found to be approximately 0.137 mSv/y, 0.062 mSv/y, 0.103 mSv/y, 0.084 mSv/y and 0.327 mSv/y respectively