ALAlamsyah

Alamsyah

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Alamsyah has a total of 5 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Web-Based Wireless Monitoring System on Patient’s Vital Sign

    by Mery Subito, Alamsyah, Ardi Amir

    Examination of vital signs such as blood pressure, heart rate, and body temperature is the most basic essential function of the body in determining the health status of the patient. In general, examining vital signs performed by a doctor or nurse uses an electrocardiogram, thermometer, and sphygmomanometer. However, this tool has a weakness in terms of time efficiency and accuracy of reading vital sign data. The process of taking vital sign data for a long time, the limited number of medical personnel in handling patients, and increasing administrative costs certainly become a concern for management in improving health services. To overcome this problem, we proposed a design that can monitor the health condition of patients' vital signs efficiently and in real time. The system used in this study consisted of an HRM-2511E type heartbeat sensor in pulse units per minute (bpm), DS18b20 body type temperature sensor in degrees Celsius (0C), and MPX5700AP sensor in mmHg units. This research is fundamental and is useful in helping medical personnel in monitoring patients' vital sign health conditions. The results of the proposed design showed that the heart rate, temperature, and blood pressure devices worked well with respective accuracy of 97.64%, 99.51%, and 97.53%.


  • Open Access

    Patients’ Heart Monitoring System Based on Wireless Sensor Network

    by T S Sollu, Alamsyah, M Bachtiar, A G Sooai

    Wireless sensor network (WSN) has been utilized to support the health field such as monitoring the patient's heartbeat. Heart health monitoring is essential in maintaining health, especially in the elderly. Such an arrangement is needed to understand the patient's heart characteristics. The increasing number of patients certainly will enhance the burdens of doctors or nurses in dealing with the condition of the patients. Therefore, required a solution that could help doctors or nurses in monitoring the progress of patients' health at a real time. This research proposes a design and application of a patient heart monitoring system based on WSN. This system with using electrocardiograph (ECG) mounted on the patients' body and sent to the server through the ZigBee. The results indicated that the retrieval of data for 15 seconds in male patients, with the age of 25 years was 17 times rate or equal to 68 bpm. For 884 data packets sent for 15 minutes using ZigBee produce a data as much as 4488 bytes, throughput of 2.39 Kbps, and 0.24486 seconds of average delay. The measurement of the communication coverage based on the open space conditions within 15 seconds through ZigBee resulting throughput value of 4.19 Kbps, packet loss of 0 %, and 6.667 seconds of average delay. While, the measurement of communication range based on closed space condition through ZigBee resulting throughput of 4.27 Kbps, packet loss of 0 %, and 6.55 seconds of average delay.