Laiqing Li
Research Subjects
Laiqing Li has a total of 52 co-authors. Here are the top co-authors by number of shared publications:
Cuicui Chen
Guangzhou Youdi Bio‐technology Co., Ltd Guangzhou China
9 shared publicationsHuankun Liang
Guangzhou Youdi Bio-Technology Co., Ltd., Guangzhou 510663, China
9 shared publicationsGuiling Guo
Guangzhou Youdi Bio-Technology Co., Ltd., Guangzhou 510663, China
5 shared publicationsHongrui Lai
Guangzhou Youdi Bio-Technology Co., Ltd., Guangzhou 510663, China
4 shared publicationsQian Mao
Department of Cardiology Beihua University Affiliated Hospital Jilin China
4 shared publicationsShuhai Zhong
Guangzhou Youdi Bio-Technology Co., Ltd., Guangzhou 510663, China
4 shared publications
Latest Publications
- 20 November 2025
- Published by Elsevier in Journal of Virological Methods
- Vol. 340, 115302
Development of a dual-label time-resolved fluorescence immunoassay platform for simultaneous detection of canine distemper virus and parvovirus
- 20 November 2025
- Published by Elsevier in Journal of Virological Methods
- Vol. 340, 115302
Development of a dual-label time-resolved fluorescence immunoassay platform for simultaneous detection of canine distemper virus and parvovirus
- 30 April 2024
- Published by Wiley in Biotechnology and Applied Biochemistry
- Vol. 71 (5) , 1025-1031
Quantitative detection of mpox antigen using time‐resolved fluorescence immunochromatography
Recently, concern has been raised about the spread of human mpox virus, and the demand for rapid detection reagents for mpox virus has increased. This study aims to establish a time‐resolved fluorescence immunochromatography (TRFICO) method for qualitative/quantitative detection of mpox virus. A double‐antibody sandwich TRFICO method was optimized and established using mpox recombinant fusion antigen and its paired monoclonal antibody. The test performance of the method was evaluated using mpox fusion antigen and control serum, including sensitivity, linearity range, specificity, precision, and reference interval. We successfully established a TRFICO method for qualitative/quantitative detection of mpox antigen, its linearity range 0–100 ng/mL, analytical sensitivity 0.017 ng/mL, and reference intervals greater than 0.045 ng/mL. No cross‐reaction was detected with various poxvirus and clinical negative controls, with good specificity. All average recoveries of the intra‐ and inter‐batch ranged from 81.33% to 97.83%, and all CVs were below 10%. Additionally, the TRFICO strips can be stably stored at 37°C for 7 days without significant changes in the fluorescence intensity. This TRFICO method, with high sensitivity, linearity range, specificity, precision, and stability with 16‐min detection time, provides a new option for qualitative/quantitative and convenient testing of mpox virus.
- 30 April 2024
- Published by Wiley in Biotechnology and Applied Biochemistry
- Vol. 71 (5) , 1025-1031
Quantitative detection of mpox antigen using time‐resolved fluorescence immunochromatography
Recently, concern has been raised about the spread of human mpox virus, and the demand for rapid detection reagents for mpox virus has increased. This study aims to establish a time‐resolved fluorescence immunochromatography (TRFICO) method for qualitative/quantitative detection of mpox virus. A double‐antibody sandwich TRFICO method was optimized and established using mpox recombinant fusion antigen and its paired monoclonal antibody. The test performance of the method was evaluated using mpox fusion antigen and control serum, including sensitivity, linearity range, specificity, precision, and reference interval. We successfully established a TRFICO method for qualitative/quantitative detection of mpox antigen, its linearity range 0–100 ng/mL, analytical sensitivity 0.017 ng/mL, and reference intervals greater than 0.045 ng/mL. No cross‐reaction was detected with various poxvirus and clinical negative controls, with good specificity. All average recoveries of the intra‐ and inter‐batch ranged from 81.33% to 97.83%, and all CVs were below 10%. Additionally, the TRFICO strips can be stably stored at 37°C for 7 days without significant changes in the fluorescence intensity. This TRFICO method, with high sensitivity, linearity range, specificity, precision, and stability with 16‐min detection time, provides a new option for qualitative/quantitative and convenient testing of mpox virus.
- Open Access
- 14 January 2024
- Published by Elsevier in Practical Laboratory Medicine
- Vol. 38, e00356
Development of a fluorescence immunochromatography method for quantitative measurement of matrix metalloproteinase-9
- 14 January 2024
- Published by Elsevier in Practical Laboratory Medicine
- Vol. 38, e00356
Open AccessDevelopment of a fluorescence immunochromatography method for quantitative measurement of matrix metalloproteinase-9
- 10 June 2023
- Published by Elsevier in Journal of Immunological Methods
- Vol. 520, 113513
Determination of echinococcosis IgG antibodies using magnetic bead-based chemiluminescence immunoassay
- 10 June 2023
- Published by Elsevier in Journal of Immunological Methods
- Vol. 520, 113513
Determination of echinococcosis IgG antibodies using magnetic bead-based chemiluminescence immunoassay
- 4 January 2022
- Published by Wiley in Biotechnology and Applied Biochemistry
- Vol. 69 (6) , 2617-2623
Time‐resolved fluorescence immunoassay (TRFIA) for the simultaneous detection of hs‐CRP and lipoprotein(a) in serum
Elevated serum high‐sensitivity C‐reactive protein (hs‐CRP) and lipoprotein(a) (Lp(a)) levels are associated with the development of native coronary atherosclerosis. We aimed to establish a new method for the simultaneous detection of hs‐CRP and Lp(a) to predict the development of atherosclerosis. A one‐step time‐resolved fluorescence immunoassay (TRFIA) with europium(III) (Eu3+) or samarium(III) (Sm3+) labels was established, and the performance of this TRFIA (in terms of sensitivity, specificity, accuracy, and cutoff values) was evaluated using clinical serum samples and compared with those of registered kits. The sensitivity was 0.052 μg/ml for hs‐CRP and 0.64 μg/ml for Lp(a). The intra‐assay and inter‐assay cross‐reactivities (CVs) were very low, ranging from 2.05% to 4.67% for hs‐CRP and from 2.42% to 6.43% for Lp(a). The CVs were very low (Pearson coefficient between the present TRFIA method and the registered kits (R2 = 0.9967 and 0.9906, respectively). These data indicate that this study developed a TRFIA method that can be used for the quantitative detection of hs‐CRP and Lp(a) in serum with high sensitivity, specificity, and accuracy. This TRFIA provides a new method for predicting the development of atherosclerosis.
- 4 January 2022
- Published by Wiley in Biotechnology and Applied Biochemistry
- Vol. 69 (6) , 2617-2623
Time‐resolved fluorescence immunoassay (TRFIA) for the simultaneous detection of hs‐CRP and lipoprotein(a) in serum
Elevated serum high‐sensitivity C‐reactive protein (hs‐CRP) and lipoprotein(a) (Lp(a)) levels are associated with the development of native coronary atherosclerosis. We aimed to establish a new method for the simultaneous detection of hs‐CRP and Lp(a) to predict the development of atherosclerosis. A one‐step time‐resolved fluorescence immunoassay (TRFIA) with europium(III) (Eu3+) or samarium(III) (Sm3+) labels was established, and the performance of this TRFIA (in terms of sensitivity, specificity, accuracy, and cutoff values) was evaluated using clinical serum samples and compared with those of registered kits. The sensitivity was 0.052 μg/ml for hs‐CRP and 0.64 μg/ml for Lp(a). The intra‐assay and inter‐assay cross‐reactivities (CVs) were very low, ranging from 2.05% to 4.67% for hs‐CRP and from 2.42% to 6.43% for Lp(a). The CVs were very low (Pearson coefficient between the present TRFIA method and the registered kits (R2 = 0.9967 and 0.9906, respectively). These data indicate that this study developed a TRFIA method that can be used for the quantitative detection of hs‐CRP and Lp(a) in serum with high sensitivity, specificity, and accuracy. This TRFIA provides a new method for predicting the development of atherosclerosis.
- 8 September 2021
- Published by Springer Nature in Journal of Fluorescence
- Vol. 31 (6) , 1771-1777
Time-resolved Fluorescence Immunoassay (TRFIA) for the Simultaneous Detection of MMP-9 and Lp-PLA2 in Serum
Currently, atherosclerosis accounts for the majority of cardiovascular morbidity and mortality worldwide, and predicting the stability of atherosclerotic plaque is the main method to prevent atherosclerotic death. This study aims to establish a dual-label time-resolved fluorescence immunoassay (TRFIA) of matrix metalloprotein-9 (MMP-9) and lipoprotein-associated phospholipaseA2 (Lp-PLA2) to predict atherosclerotic plaque stability. A dual-label TRFIA was introduced for the simultaneous quantification of MMP-9 and Lp-PLA2 using fluorescent lanthanide (Eu3+ and Sm3+) chelates. The performance (sensitivity, specificity, accuracy, precision and reference intervals in different subjects) of this TRFIA was evaluated and compared with commercial kit. The sensitivity of the TRFIA for MMP-9 was 0.85 ng/mL and for Lp-PLA2 was 0.68 ng/mL with high affinity and specificity. The average recoveries were 94.58% to 109.82%, and 104.32% to 109.26%, respectively. All intra- and inter-assay CVs ranged from 3.10% to 5.46%. For the normal subjects, the cutoff value was 160.70 ng/mL for MMP-9 and 183.73 ng/mL for LP-PLA2; for the subjects with stable plaque, the cutoff value was 181.98~309.22 ng/mL for MMP-9 and 194.73~337.89 ng/mL for LP-PLA2; for the subjects with unstable plaque, the cutoff value was 330.43 ng/mL for MMP-9 and 343.23 ng/mL for LP-PLA2. This TRFIA detection results agreed well with the results of commercial kit (R2=0.9567 and R2=0.9771, respectively) in clinical serum samples. The TRFIA developed has a wide detection range and good sensitivity for the high-throughput simultaneous detection of MMP-9 and Lp-PLA2 in serum, which provides a new method for predicting the stability of atherosclerotic plaque.
- 8 September 2021
- Published by Springer Nature in Journal of Fluorescence
- Vol. 31 (6) , 1771-1777
Time-resolved Fluorescence Immunoassay (TRFIA) for the Simultaneous Detection of MMP-9 and Lp-PLA2 in Serum
Currently, atherosclerosis accounts for the majority of cardiovascular morbidity and mortality worldwide, and predicting the stability of atherosclerotic plaque is the main method to prevent atherosclerotic death. This study aims to establish a dual-label time-resolved fluorescence immunoassay (TRFIA) of matrix metalloprotein-9 (MMP-9) and lipoprotein-associated phospholipaseA2 (Lp-PLA2) to predict atherosclerotic plaque stability. A dual-label TRFIA was introduced for the simultaneous quantification of MMP-9 and Lp-PLA2 using fluorescent lanthanide (Eu3+ and Sm3+) chelates. The performance (sensitivity, specificity, accuracy, precision and reference intervals in different subjects) of this TRFIA was evaluated and compared with commercial kit. The sensitivity of the TRFIA for MMP-9 was 0.85 ng/mL and for Lp-PLA2 was 0.68 ng/mL with high affinity and specificity. The average recoveries were 94.58% to 109.82%, and 104.32% to 109.26%, respectively. All intra- and inter-assay CVs ranged from 3.10% to 5.46%. For the normal subjects, the cutoff value was 160.70 ng/mL for MMP-9 and 183.73 ng/mL for LP-PLA2; for the subjects with stable plaque, the cutoff value was 181.98~309.22 ng/mL for MMP-9 and 194.73~337.89 ng/mL for LP-PLA2; for the subjects with unstable plaque, the cutoff value was 330.43 ng/mL for MMP-9 and 343.23 ng/mL for LP-PLA2. This TRFIA detection results agreed well with the results of commercial kit (R2=0.9567 and R2=0.9771, respectively) in clinical serum samples. The TRFIA developed has a wide detection range and good sensitivity for the high-throughput simultaneous detection of MMP-9 and Lp-PLA2 in serum, which provides a new method for predicting the stability of atherosclerotic plaque.
- Open Access
- 1 August 2021
- Published by Wiley in Biotechnology and Applied Biochemistry
- Vol. 69 (4) , 1474-1481
Determination of human COVID‐19 total antibodies in serum using a time‐resolved fluorescence immunoassay
Coronavirus disease 2019 (COVID-19) caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is spreading rapidly around the world. Antibody detection plays an important role in the diagnosis of COVID-19. Here, we established a new time-resolved fluorescence immunoassay (TRFIA) to determine COVID-19 total antibodies. A double antigen sandwich TRFIA was optimized and established: recombinant nucleocapsid phosphoprotein (N protein) and spike protein (S protein) of COVID-19 immobilized on 96-well plates captured human COVID-19 antibodies and then banded together with the N/S proteins labeled with europium(III) (Eu3+) chelates, and finally, time-resolved fluorometry was used to measure the fluorescence values. We successfully established a TRFIA method for the detection of human COVID-19 total antibodies, and the cutoff value was 2.02. There was no cross-reactivity with the negative reference of the National Reference Panel for IgM and IgG antibodies to COVID-19. The CV of the precision assay was 3.19%, and the assay could be stored stably for 15 days at 37°C. Compared with that of the colloidal gold method and chemiluminescence method, the sensitivity of the TRFIA method was higher, and the false positive/negative rate was lower. This established TRFIA has high sensitivity, accuracy and specificity, which indicates that this method provides a new detection method for the high-throughput routine diagnosis of COVID-19. This article is protected by copyright. All rights reserved
- 1 August 2021
- Published by Wiley in Biotechnology and Applied Biochemistry
- Vol. 69 (4) , 1474-1481
Open AccessDetermination of human COVID‐19 total antibodies in serum using a time‐resolved fluorescence immunoassay
Coronavirus disease 2019 (COVID-19) caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is spreading rapidly around the world. Antibody detection plays an important role in the diagnosis of COVID-19. Here, we established a new time-resolved fluorescence immunoassay (TRFIA) to determine COVID-19 total antibodies. A double antigen sandwich TRFIA was optimized and established: recombinant nucleocapsid phosphoprotein (N protein) and spike protein (S protein) of COVID-19 immobilized on 96-well plates captured human COVID-19 antibodies and then banded together with the N/S proteins labeled with europium(III) (Eu3+) chelates, and finally, time-resolved fluorometry was used to measure the fluorescence values. We successfully established a TRFIA method for the detection of human COVID-19 total antibodies, and the cutoff value was 2.02. There was no cross-reactivity with the negative reference of the National Reference Panel for IgM and IgG antibodies to COVID-19. The CV of the precision assay was 3.19%, and the assay could be stored stably for 15 days at 37°C. Compared with that of the colloidal gold method and chemiluminescence method, the sensitivity of the TRFIA method was higher, and the false positive/negative rate was lower. This established TRFIA has high sensitivity, accuracy and specificity, which indicates that this method provides a new detection method for the high-throughput routine diagnosis of COVID-19. This article is protected by copyright. All rights reserved
- 1 June 2021
- Published by Springer Nature in Journal of Fluorescence
- Vol. 31 (5) , 1291-1296
A New Method for Detection African Swine Fever Virus: Time-resolved Fluorescence Immunoassay
African swine fever (ASF) has severely influenced the swine industry of the whole world. Fast and accurate African swine fever virus (ASFV) antigen detection is very important for ASF prevention. This study aims to establish a new detection method for detection ASFV antigen using time-resolved fluorescence immunoassay (TRFIA) in the nose and mouth discharge. A double antibody sandwich TRFIA method was optimized and established. Recombinant P30 recombinant antigen was captured by its antibodies immobilized on 96-well plate, and then banded together with another detection antibodies labeled with Europium(III) (Eu3+) chelates, finally time-resolved analyzer measured the fluorescence intensity. The performance of this TRFIA (sensitivity, specificity and accuracy) was evaluated using the clinical samples and compared with the nucleic acid testing method. The sensitivity of this TRFIA was 0.015 ng/mL (dynamic range 0.24–500 ng/mL) with high specificity. The recovery ranged from 92.00 to 103.62 %, the inter-assay CVs ranged from 5.50 to 11.96 %, and the intra-assay CVs was between 5.20 and 10.53 %. Additionally, the cutoff value was 0.016. TRFIA took only 45 min to generate results, and its detection capability comparable to the nucleic acid detection. This study developed a TRFIA method that could be used for qualitative/quantitative detection of ASFV antigen in pigs nasal discharge, which has high sensitivity, specificity and accuracy. This TRFIA provides a new method for rapidly screening ASFV infection in pigs industry.
- 1 June 2021
- Published by Springer Nature in Journal of Fluorescence
- Vol. 31 (5) , 1291-1296
A New Method for Detection African Swine Fever Virus: Time-resolved Fluorescence Immunoassay
African swine fever (ASF) has severely influenced the swine industry of the whole world. Fast and accurate African swine fever virus (ASFV) antigen detection is very important for ASF prevention. This study aims to establish a new detection method for detection ASFV antigen using time-resolved fluorescence immunoassay (TRFIA) in the nose and mouth discharge. A double antibody sandwich TRFIA method was optimized and established. Recombinant P30 recombinant antigen was captured by its antibodies immobilized on 96-well plate, and then banded together with another detection antibodies labeled with Europium(III) (Eu3+) chelates, finally time-resolved analyzer measured the fluorescence intensity. The performance of this TRFIA (sensitivity, specificity and accuracy) was evaluated using the clinical samples and compared with the nucleic acid testing method. The sensitivity of this TRFIA was 0.015 ng/mL (dynamic range 0.24–500 ng/mL) with high specificity. The recovery ranged from 92.00 to 103.62 %, the inter-assay CVs ranged from 5.50 to 11.96 %, and the intra-assay CVs was between 5.20 and 10.53 %. Additionally, the cutoff value was 0.016. TRFIA took only 45 min to generate results, and its detection capability comparable to the nucleic acid detection. This study developed a TRFIA method that could be used for qualitative/quantitative detection of ASFV antigen in pigs nasal discharge, which has high sensitivity, specificity and accuracy. This TRFIA provides a new method for rapidly screening ASFV infection in pigs industry.
- 21 September 2020
- Published by Bentham Science Publishers Ltd. in Current Pharmaceutical Biotechnology
- Vol. 21 (11) , 1099-1106
Effects and Mechanism of Chlorogenic Acid on Weight Loss
Background: Chlorogenic Acid (CA) has diverse, recognized health effects. Objective: This study aimed to explore the effects of CA on fat reduction and the underlying mechanism of these effects. Materials and Methods: First, we established a Monosodium Glutamate (MSG)-induced obesity mouse model and subjected the mice to 4 weeks of CA gavage. Then, we established an oleic acidinduced model of human fatty liver in HepG2 cells, and administered a CA intervention to the cells for 48 h. Finally, we used Oil red O staining, biochemical detection kits, RT-PCR and Western blot analysis to evaluate the effects of CA on fat reduction and on related pathways. Results: The CA treatment could reduce fat accumulation in the liver and reduce blood lipid levels. In addition, CA decreased the mRNA and protein levels of peroxisome proliferator-activated receptor gamma, coactivator 1 α (PGC-1α) and Uncoupling Protein 1 (UCP1) in the MSG-induced obesity mouse model and the oleic acid-induced HepG2 cells. Conclusion: Based on the above results, we deduced that CA could reduce body weight and fat deposition in vitro and in vivo and that the mechanism may be related to the PGC-1α/UCP-1 pathway. CA can be developed as a drug to lower blood lipids and to treat obesity.
- 21 September 2020
- Published by Bentham Science Publishers Ltd. in Current Pharmaceutical Biotechnology
- Vol. 21 (11) , 1099-1106
Effects and Mechanism of Chlorogenic Acid on Weight Loss
Background: Chlorogenic Acid (CA) has diverse, recognized health effects. Objective: This study aimed to explore the effects of CA on fat reduction and the underlying mechanism of these effects. Materials and Methods: First, we established a Monosodium Glutamate (MSG)-induced obesity mouse model and subjected the mice to 4 weeks of CA gavage. Then, we established an oleic acidinduced model of human fatty liver in HepG2 cells, and administered a CA intervention to the cells for 48 h. Finally, we used Oil red O staining, biochemical detection kits, RT-PCR and Western blot analysis to evaluate the effects of CA on fat reduction and on related pathways. Results: The CA treatment could reduce fat accumulation in the liver and reduce blood lipid levels. In addition, CA decreased the mRNA and protein levels of peroxisome proliferator-activated receptor gamma, coactivator 1 α (PGC-1α) and Uncoupling Protein 1 (UCP1) in the MSG-induced obesity mouse model and the oleic acid-induced HepG2 cells. Conclusion: Based on the above results, we deduced that CA could reduce body weight and fat deposition in vitro and in vivo and that the mechanism may be related to the PGC-1α/UCP-1 pathway. CA can be developed as a drug to lower blood lipids and to treat obesity.
- 13 June 2020
- Published by Wiley in Biotechnology and Applied Biochemistry
- Vol. 68 (3) , 597-602
Determination of parvovirus antigen in the vaccine using time‐resolved fluorescence immunoassay
As a highly contagious and potentially fatal disease of dogs, canine parvovirus type 2 (CPV‐2) usually causes severe myocarditis and gastroenteritis, while vaccine injection has greatly reduced the incidence of CPV‐2 diseases. However, there is currently a lack of simple and effective method for quantitative detection of CPV‐2 in vaccine. Therefore, this study aims to prepare an accurate method to determine the CPV‐2 antigen (CPV‐2‐Ag) in vaccine. Here, a sandwich time‐resolved fluorescence immunoassay (TRFIA) was established and optimized. Anti‐CPV‐2 antibodies were immobilized on 96‐well plates to capture CPV‐2‐Ag, and then bound together with the detection antibodies labeled with Europium(III) (Eu3+) chelates; finally, time‐resolved fluorometry was employed to measure the fluorescence intensity. Vaccination was performed to evaluate the relationship between CPV‐2‐Ag concentration and antibody titer. The sensitivity is 1.15 mEU/mL (LogY = 1.524 + 0.8667 × LogX , R 2 = 0.9933), and the average recovery is among 91.00% to 106.39% without cross‐reactions with the other canine viral antigen. The correlation between ELISA assay and this method is up to 0.9861. And, there is high correlation between the CPV‐2‐Ag concentration and antibody titers (R 2 = 0.9234). This immunoassay established has high sensitivity, accuracy, and specificity, which indicate that this method could be suitable for quantitative detection of CPV‐2‐Ag in vaccine evaluation.
- 13 June 2020
- Published by Wiley in Biotechnology and Applied Biochemistry
- Vol. 68 (3) , 597-602
Determination of parvovirus antigen in the vaccine using time‐resolved fluorescence immunoassay
As a highly contagious and potentially fatal disease of dogs, canine parvovirus type 2 (CPV‐2) usually causes severe myocarditis and gastroenteritis, while vaccine injection has greatly reduced the incidence of CPV‐2 diseases. However, there is currently a lack of simple and effective method for quantitative detection of CPV‐2 in vaccine. Therefore, this study aims to prepare an accurate method to determine the CPV‐2 antigen (CPV‐2‐Ag) in vaccine. Here, a sandwich time‐resolved fluorescence immunoassay (TRFIA) was established and optimized. Anti‐CPV‐2 antibodies were immobilized on 96‐well plates to capture CPV‐2‐Ag, and then bound together with the detection antibodies labeled with Europium(III) (Eu3+) chelates; finally, time‐resolved fluorometry was employed to measure the fluorescence intensity. Vaccination was performed to evaluate the relationship between CPV‐2‐Ag concentration and antibody titer. The sensitivity is 1.15 mEU/mL (LogY = 1.524 + 0.8667 × LogX , R 2 = 0.9933), and the average recovery is among 91.00% to 106.39% without cross‐reactions with the other canine viral antigen. The correlation between ELISA assay and this method is up to 0.9861. And, there is high correlation between the CPV‐2‐Ag concentration and antibody titers (R 2 = 0.9234). This immunoassay established has high sensitivity, accuracy, and specificity, which indicate that this method could be suitable for quantitative detection of CPV‐2‐Ag in vaccine evaluation.