Rajeswara Reddy Resapu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Rajeswara Reddy Resapu has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
Daniel B. Jones
Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, USA
2 shared publications- Ganesh Sankaranarayanan
Department of Surgery, University of Texas Southwestern Medical Center, Dallas, USA
2 shared publications - Roger D. Bradshaw
University of Louisville
2 shared publications Steven Schwaitzberg
Cambridge Health Alliance, Cambridge, USA
2 shared publications- Suvranu De
Mechanical Engineering, FAMU-FSU College of Engineering, Tallahassee, Florida, USA
2 shared publications - Ashok Kumar Barik
National Institute of Technology
1 shared publication
Latest Publications
- 20 November 2025
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 196
Effects of gaseous ammonia enriched third generation biodiesel on the evaluation of diesel engine operating parameters
- 20 November 2025
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 196
Effects of gaseous ammonia enriched third generation biodiesel on the evaluation of diesel engine operating parameters
- 1 December 2022
- Published by AIP Publishing in Physics of Fluids
- Vol. 34 (12) , 123609
The propulsion of tandem flapping foil following fishtailed flapping trajectory
It has always been a challenge to implement the natural flyer and swimmer kinematics into human-made aero/hydro vehicles for the enhancement of their performance. The propulsive performance of underwater vehicles can be enhanced by following the fishtailed kinematics. In the present study, a two-dimensional simulation has been performed on a tandem flapping foil by altering the simple flapping trajectory motion to a fishtailed trajectory by varying the Strouhal number (St) in the range of 0.1–0.5. The effect of the inter-foil spacing and phasing between the foils on wake interaction is also investigated. The results show that fishtailed trajectory motion and inter-foil spacing of 2cm–3cm (where cm is the mean chord length) between the foils would enhance the propulsive efficiency of the downstream foil by up to 41%. The unfavorable spacing between the foils results in adverse wake interaction, which reduces the propulsive efficiency compared to solo flapping foil.
- 1 December 2022
- Published by AIP Publishing in Physics of Fluids
- Vol. 34 (12) , 123609
The propulsion of tandem flapping foil following fishtailed flapping trajectory
It has always been a challenge to implement the natural flyer and swimmer kinematics into human-made aero/hydro vehicles for the enhancement of their performance. The propulsive performance of underwater vehicles can be enhanced by following the fishtailed kinematics. In the present study, a two-dimensional simulation has been performed on a tandem flapping foil by altering the simple flapping trajectory motion to a fishtailed trajectory by varying the Strouhal number (St) in the range of 0.1–0.5. The effect of the inter-foil spacing and phasing between the foils on wake interaction is also investigated. The results show that fishtailed trajectory motion and inter-foil spacing of 2cm–3cm (where cm is the mean chord length) between the foils would enhance the propulsive efficiency of the downstream foil by up to 41%. The unfavorable spacing between the foils results in adverse wake interaction, which reduces the propulsive efficiency compared to solo flapping foil.
- Open Access
- 21 April 2021
- Published by Springer Nature in SN Applied Sciences
- Vol. 3 (5) , 1-9
Application of micro-computer tomography and inverse finite element analysis for characterizing the visco-hyperelastic response of bulk liver tissue using indentation
In-vitro mechanical indentation experimentation is performed on bulk liver tissue of lamb to characterize its nonlinear material behaviour. The material response is characterized by a visco-hyperelastic material model by the use of 2-dimensional inverse finite element (FE) analysis. The time-dependent behaviour is characterized by the viscoelastic model represented by a 4-parameter Prony series, whereas the large deformations are modelled using the hyperelastic Neo-Hookean model. The shear response described by the initial and final shear moduli and the corresponding Prony series parameters are optimized using ANSYS with the Root Mean Square (RMS) error being the objective function. Optimized material properties are validated using experimental results obtained under different loading histories. To study the efficacy of a 2D model, a three dimensional (3D) model of the specimen is developed using Micro-CT of the specimen. The initial elastic modulus of the lamb liver obtained was found to 13.5 kPa for 5% indentation depth at a loading rate of 1 mm/sec for 1-cycle. These properties are able to predict the response at 8.33% depth and a loading rate of 5 mm/sec at multiple cycles with reasonable accuracy. Article highlights: The visco-hyperelastic model accurately models the large displacement as well as the time-dependent behaviour of the bulk liver tissue. Mapped meshing of the 3D FE model saves computational time and captures localized displacement in an accurate manner. The 2D axisymmetric model while predicting the force response of the bulk tissue, cannot predict the localized deformations.
- 21 April 2021
- Published by Springer Nature in SN Applied Sciences
- Vol. 3 (5) , 1-9
Open AccessApplication of micro-computer tomography and inverse finite element analysis for characterizing the visco-hyperelastic response of bulk liver tissue using indentation
In-vitro mechanical indentation experimentation is performed on bulk liver tissue of lamb to characterize its nonlinear material behaviour. The material response is characterized by a visco-hyperelastic material model by the use of 2-dimensional inverse finite element (FE) analysis. The time-dependent behaviour is characterized by the viscoelastic model represented by a 4-parameter Prony series, whereas the large deformations are modelled using the hyperelastic Neo-Hookean model. The shear response described by the initial and final shear moduli and the corresponding Prony series parameters are optimized using ANSYS with the Root Mean Square (RMS) error being the objective function. Optimized material properties are validated using experimental results obtained under different loading histories. To study the efficacy of a 2D model, a three dimensional (3D) model of the specimen is developed using Micro-CT of the specimen. The initial elastic modulus of the lamb liver obtained was found to 13.5 kPa for 5% indentation depth at a loading rate of 1 mm/sec for 1-cycle. These properties are able to predict the response at 8.33% depth and a loading rate of 5 mm/sec at multiple cycles with reasonable accuracy. Article highlights: The visco-hyperelastic model accurately models the large displacement as well as the time-dependent behaviour of the bulk liver tissue. Mapped meshing of the 3D FE model saves computational time and captures localized displacement in an accurate manner. The 2D axisymmetric model while predicting the force response of the bulk tissue, cannot predict the localized deformations.
- 1 March 2018
- Published by Walter de Gruyter GmbH
Transesterification of Degummed Jatropha curcas Oil Using Tri-potassium Phosphate as Base Catalyst
Jatropha curcas oil and methanol are transesterified using potassium triphosphate as base catalyst. The effects of methanol to oil molar ratio, reaction temperature, stirring speed, catalyst concentration, solubility and its reusability on the yield of biodiesel are investigated. The base catalyst tri-potassium phosphate (K3PO4) is found to be highly suitable for oils having less than 1.5% free fatty acids (FFA). Highest biodiesel yield (approximately 92%) is acquired under optimum conditions of 9:1 methanol to oil molar ratio, 2% catalyst at 70°C reaction temperature at a stirring speed of 650 rpm. The chemical activity of K3PO4 is found to be similar to that of base catalyst potassium hydroxide (KOH) and the catalyst solubility in biodiesel as determined by atomic absorption spectra is only 4.81 ppm. It has been found that K3PO4 is highly hygroscopic and its reusability drastically decreases upon further usage and it can be reused only in wetted condition for three continuous usages with drastic reduction in catalytic strength. The biodiesel samples prepared were tested for several physicochemical properties and compared with the values of European biodiesel standards. The fatty acid methyl esters (FAME), also referred to as jatropha methyl esters (JME) in this paper, have been analyzed by gas chromatography and thermogravimetric analysis.
- 1 March 2018
- Published by Walter de Gruyter GmbH
Transesterification of Degummed Jatropha curcas Oil Using Tri-potassium Phosphate as Base Catalyst
Jatropha curcas oil and methanol are transesterified using potassium triphosphate as base catalyst. The effects of methanol to oil molar ratio, reaction temperature, stirring speed, catalyst concentration, solubility and its reusability on the yield of biodiesel are investigated. The base catalyst tri-potassium phosphate (K3PO4) is found to be highly suitable for oils having less than 1.5% free fatty acids (FFA). Highest biodiesel yield (approximately 92%) is acquired under optimum conditions of 9:1 methanol to oil molar ratio, 2% catalyst at 70°C reaction temperature at a stirring speed of 650 rpm. The chemical activity of K3PO4 is found to be similar to that of base catalyst potassium hydroxide (KOH) and the catalyst solubility in biodiesel as determined by atomic absorption spectra is only 4.81 ppm. It has been found that K3PO4 is highly hygroscopic and its reusability drastically decreases upon further usage and it can be reused only in wetted condition for three continuous usages with drastic reduction in catalytic strength. The biodiesel samples prepared were tested for several physicochemical properties and compared with the values of European biodiesel standards. The fatty acid methyl esters (FAME), also referred to as jatropha methyl esters (JME) in this paper, have been analyzed by gas chromatography and thermogravimetric analysis.
- 1 November 2016
- Published by Elsevier in Journal of Cleaner Production
- Vol. 137, 490-506
Effect of a zinc oxide nanoparticle fuel additive on the emission reduction of a hydrogen dual-fuelled engine with jatropha methyl ester biodiesel blends
- 1 November 2016
- Published by Elsevier in Journal of Cleaner Production
- Vol. 137, 490-506
Effect of a zinc oxide nanoparticle fuel additive on the emission reduction of a hydrogen dual-fuelled engine with jatropha methyl ester biodiesel blends
- 8 October 2013
- Published by Springer Nature in Surgical Endoscopy
- Vol. 27 (12) , 4758
Erratum to: Common uses and cited complications of energy in surgery
- 8 October 2013
- Published by Springer Nature in Surgical Endoscopy
- Vol. 27 (12) , 4758
Erratum to: Common uses and cited complications of energy in surgery
- 23 April 2013
- Published by Springer Nature in Surgical Endoscopy
- Vol. 27 (9) , 3056-3072
Common uses and cited complications of energy in surgery
Background Instruments that apply energy to cut, coagulate, and dissect tissue with minimal bleeding facilitate surgery. The improper use of energy devices may increase patient morbidity and mortality. The current article reviews various energy sources in terms of their common uses and safe practices. Methods For the purpose of this review, a general search was conducted through NCBI, SpringerLink, and Google. Articles describing laparoscopic or minimally invasive surgeries using single or multiple energy sources are considered, as are articles comparing various commercial energy devices in laboratory settings. Keywords, such as laparoscopy, energy, laser, electrosurgery, monopolar, bipolar, harmonic, ultrasonic, cryosurgery, argon beam, laser, complications, and death were used in the search. Results A review of the literature shows that the performance of the energy devices depends upon the type of procedure. There is no consensus as to which device is optimal for a given procedure. The technical skill level of the surgeon and the knowledge about the devices are both important factors in deciding safe outcomes. Conclusions As new energy devices enter the market increases, surgeons should be aware of their indicated use in laparoscopic, endoscopic, and open surgery.
- 23 April 2013
- Published by Springer Nature in Surgical Endoscopy
- Vol. 27 (9) , 3056-3072
Common uses and cited complications of energy in surgery
Background Instruments that apply energy to cut, coagulate, and dissect tissue with minimal bleeding facilitate surgery. The improper use of energy devices may increase patient morbidity and mortality. The current article reviews various energy sources in terms of their common uses and safe practices. Methods For the purpose of this review, a general search was conducted through NCBI, SpringerLink, and Google. Articles describing laparoscopic or minimally invasive surgeries using single or multiple energy sources are considered, as are articles comparing various commercial energy devices in laboratory settings. Keywords, such as laparoscopy, energy, laser, electrosurgery, monopolar, bipolar, harmonic, ultrasonic, cryosurgery, argon beam, laser, complications, and death were used in the search. Results A review of the literature shows that the performance of the energy devices depends upon the type of procedure. There is no consensus as to which device is optimal for a given procedure. The technical skill level of the surgeon and the knowledge about the devices are both important factors in deciding safe outcomes. Conclusions As new energy devices enter the market increases, surgeons should be aware of their indicated use in laparoscopic, endoscopic, and open surgery.
- 4 December 2007
- Published by Springer Nature in Experimental Mechanics
- Vol. 48 (6) , 713-729
A Finite Element Method for the Determination of Optimal Viscoelastic Material Properties from Indentation Tests of Polymer Film and Wire with Polymer Insulation
- 4 December 2007
- Published by Springer Nature in Experimental Mechanics
- Vol. 48 (6) , 713-729
A Finite Element Method for the Determination of Optimal Viscoelastic Material Properties from Indentation Tests of Polymer Film and Wire with Polymer Insulation