Dario Masucci
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Dario Masucci has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Chiara Foglietta
Department of Promotion of Human Sciences and Quality of Life, San Raffaele Roma Open University, Rome, Italy
2 shared publications - Cosimo Palazzo
University “Roma Tre
2 shared publications - Stefano Panzieri
Department of Civil, Computer Science and Aeronautical Technologies Engineering, University of Roma Tre, Rome, Italy
2 shared publications Chiara Foglietta
Engineering Department, Roma TRE University, Rome, Italy
1 shared publication- Leonid Lev
Israel Electric Corporation, Haifa 31000, Israel
1 shared publication - Luis Rosa
OneSource, Coimbra, Portugal
1 shared publication
Latest Publications
- 10 May 2021
- Published by Taylor & Francis in Intelligent Buildings International
- Vol. 14 (5) , 564-580
Enhancing the smart building supervisory system effectiveness
Modern buildings are managed by the BMS (Building Management System), a supervisory system that controls its mechanical and electrical devices. The automatic detection of faults and malfunctions plays a crucial role in the monitoring and control processes of electrical devices located in a smart building. The integration of this functionality within a BMS allows to improve the consistency and the effectiveness of the control network and to recognize and report in real-time the system’s malfunctioning. The research focuses on the definition of Fault Detection procedures to verify the successful implementation of sequential commands given by control and supervisory system. The authors realize a tool to control and manage in real-time the data coming from the sensors to verify the effective implementation of a command. The procedure is based on the following important assumption – we must be able to associate the trend of a given reference magnitude with each command. By monitoring the magnitude’s status and comparing them with default threshold values, the algorithms determine the command execution. Authors apply the proposed strategies on the F40 building, located in the ENEA R.C. ‘La Casaccia’, to detect faults and anomalies that can be traced to probable cyber intrusion or devices malfunctioning.
- 10 May 2021
- Published by Taylor & Francis in Intelligent Buildings International
- Vol. 14 (5) , 564-580
Enhancing the smart building supervisory system effectiveness
Modern buildings are managed by the BMS (Building Management System), a supervisory system that controls its mechanical and electrical devices. The automatic detection of faults and malfunctions plays a crucial role in the monitoring and control processes of electrical devices located in a smart building. The integration of this functionality within a BMS allows to improve the consistency and the effectiveness of the control network and to recognize and report in real-time the system’s malfunctioning. The research focuses on the definition of Fault Detection procedures to verify the successful implementation of sequential commands given by control and supervisory system. The authors realize a tool to control and manage in real-time the data coming from the sensors to verify the effective implementation of a command. The procedure is based on the following important assumption – we must be able to associate the trend of a given reference magnitude with each command. By monitoring the magnitude’s status and comparing them with default threshold values, the algorithms determine the command execution. Authors apply the proposed strategies on the F40 building, located in the ENEA R.C. ‘La Casaccia’, to detect faults and anomalies that can be traced to probable cyber intrusion or devices malfunctioning.
- Open Access
- 27 April 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Systems Journal
- Vol. 13 (1) , 424-435
From Detecting Cyber-Attacks to Mitigating Risk Within a Hybrid Environment
Telecommunication networks based on commonplace technologies (such as Ethernet) often constitute a vulnerable attack vector against modern critical infrastructures (CIs), particularly for supervisory control and data acquisition (SCADA) systems, which rely on them for monitoring and controlling physical components. This paper presents a unique platform that encompasses a range of capabilities, from cyber-attack detection to mitigation strategies, through interdependency and risk evaluation. The platform is made of two main components: a cyber-attack detection subsystem and a risk assessment framework. Both blocks are innovative from research point of view and they have been developed and customized to fit the CIs’ features, that are completely different from telecommunication networks. This platform has been tested on a hybrid environment testbed, made of virtual and real components, within the scope of the EU FP7 CockpitCI and EU H2020 ATENA projects. The case study corresponds to a medium voltage power grid controlled by a SCADA control center, where the platform has been validated with optimal results in terms of detection capabilities and time response.
- 27 April 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Systems Journal
- Vol. 13 (1) , 424-435
Open AccessFrom Detecting Cyber-Attacks to Mitigating Risk Within a Hybrid Environment
Telecommunication networks based on commonplace technologies (such as Ethernet) often constitute a vulnerable attack vector against modern critical infrastructures (CIs), particularly for supervisory control and data acquisition (SCADA) systems, which rely on them for monitoring and controlling physical components. This paper presents a unique platform that encompasses a range of capabilities, from cyber-attack detection to mitigation strategies, through interdependency and risk evaluation. The platform is made of two main components: a cyber-attack detection subsystem and a risk assessment framework. Both blocks are innovative from research point of view and they have been developed and customized to fit the CIs’ features, that are completely different from telecommunication networks. This platform has been tested on a hybrid environment testbed, made of virtual and real components, within the scope of the EU FP7 CockpitCI and EU H2020 ATENA projects. The case study corresponds to a medium voltage power grid controlled by a SCADA control center, where the platform has been validated with optimal results in terms of detection capabilities and time response.