NKNarelle Kennedy

Narelle Kennedy

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Narelle Kennedy has a total of 40 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Patient experience when self‐introducing gel into the vagina for assessment of deep endometriosis: A pilot study

    by Tracy Truong, Narelle Kennedy, Vasundhara Kaushik, Jennifer Alphonse, Ann Quinton

    Introduction: When scanning for deep endometriosis a 20 mL syringe is used to insert gel into the vagina for a gel sonovaginography (SVG) examination. This is invasive and can cause discomfort. The aim of this study is to compare participant experience with the self‐administration of 20 mL of gel total using a 10 mL syringe versus 20 mL syringe for participants undergoing a gel SVG ultrasound to assess for any participant discomfort.Methodology: This study was a quantitative pilot study with 31 participants. Consenting participants were instructed to insert a total of 20 mL of gel divided equally into one 20 mL and one 10 mL syringe, into their own vagina prior to SVG. After the SVG, a questionnaire was provided to determine the level of discomfort experienced.Results: Overall participants found the instructions clear and the insertion of either syringe tolerable. The results demonstrated that 22/31 (71%) of participants had no discomfort inserting the 10 mL syringe. In comparison, 17/31 (55%) reported slight or mild discomfort inserting the 20 mL syringe. The majority of participants preferred inserting one 20 mL syringe rather than two 10 mL syringes.Conclusion: Participants found the gel insertion using either syringe tolerable with most participants finding the 10 mL syringe more comfortable but would overall prefer inserting one 20 mL syringe instead of two 10 mL syringes. Future studies on larger numbers of multicultural participants using variable syringe sizes with varying amounts of gel should be considered.


  • Improving Automatic Fetal Biometry Measurement with Swoosh Activation Function

    by Shijia Zhou, Euijoon Ahn, Hao Wang, Ann Quinton, Narelle Kennedy, Pradeeba Sridar, Ralph Nanan, Jinman Kim


  • Open Access

    Atrioventricular septal defect: An extended approach to prenatal sonographic imaging of the atrioventricular valves

    by Ann E. Quinton, Narelle Kennedy, Alex Gooi

    An atrioventricular septal defect (AVSD) is diagnosed with prenatal sonography using the 4‐chamber view (4CV) of the fetal heart. Prenatal 2D sonographic imaging of normal and AVSD short axis (SAX) atrioventricular (AV) valve views have not been well described. The aim is to describe the 2D sonographic 4‐chamber and SAX view of the AV valves when an AVSD is present compared to normal AV valves. The 4CV AVSD heart demonstrates no offset of AV valves due to the abnormal valve structure. Complete and intermediate AVSD has a septum primum defect and inlet ventricular septal defect (VSD). The partial AVSDs have either a septum primum defect or just an inlet VSD with an intact primum septum. The SAX view of AVSD demonstrates the common AV junction and the bridging leaflets. In ventricular diastole valves have a “figure 8” and “dumbbell” shape in partial and complete AVSD, respectively. These appearances are not seen in the normal heart in SAX as both tricuspid and mitral valve are separate valves. The SAX view can be obtained by locating a sagittal aortic arch view and then scanning slightly towards the left side of the fetus, near the base of the heart and the AV valves. An in‐depth interrogation of the abnormal fetal heart is obtained without specialised 4D capable ultrasound machines providing information to assist in counselling during the pregnancy and for postnatal surgical planning. Future research to assess the feasibility of incorporating the SAX view into routine practice and by general sonographers is suggested.


  • Exploring the use of knobology for image optimisation in final year sonography students

    by Samantha Mallard, Narelle Kennedy, Afrooz Najafzadeh Abriz, Ann Quinton

    Introduction: Image optimisation is essential for acquisition of quality images in ultrasound and critical to the diagnostic ability of the examination. These skills are taught to sonography students early in their education, but research has found that retention of non-rehearsed knowledge decreases significantly after a year. The aim of this study was to determine which optimisation tools (knobology) final year sonography students use, how often and why they chose to adjust parameters and assess barriers to optimisation of knobology tools. Methods: A prospective study using data from an anonymous online survey of 34 final year sonography students. Results: Survey results showed that 19/34 (55%) of students “frequently” optimise all Doppler settings and 23/34 (67%) of students “frequently” optimise basic parameter settings (depth, focus, time gain compensation). Time constraints (24/34 (70%)) and loss of gained knowledge of sonography principles and instrumentation (17/34 (50%)) were the major barriers to the use of knobology. The majority 28/34 (82%) believed they would benefit from further training. Conclusion: This study demonstrates that although most students are optimising settings to improve image quality, sonography principles and instrumentation knowledge loss and time constraints prevent students from maximising machine capabilities. This study supports the need for further training prior to final year clinical placement.


  • Musculoskeletal pain amongst Australian sonography students and recent graduates and an evaluation of the use of ergonomic education for prevention

    by Natalie Bonutto, Narelle Kennedy, Ann Quinton

    Introduction/Purpose: Sonographers develop pain whilst scanning and may not consistently adhere to ergonomic recommendations. The aim was to quantify this within Australian sonography students and recent graduates and to determine whether a relationship exists between: (i) pain and failure to adhere to ergonomic recommendations; and (ii) theoretical and practical ergonomic education during university and clinical placement, and the adherence to recommendations.Methods: Online questionnaire distributed to Australian student sonographers and sonographers until two years post‐graduation.Results: During scanning, 33/39(84.62%) experienced musculoskeletal pain, and 21/33 (63.64%) experienced pain less than 1.76 full‐time equivalent (FTE) days during the two FTE week period. The majority, 37/39 (94.87%), were not consistently adhering to recommendations, with 25/37 (67.57%) only doing so for less than 2.1 FTE days during two FTE weeks. Failure to adhere to ergonomic recommendations and development of musculoskeletal scanning pain was positively correlated (r = 0.7 (P = 0.01)).All participants had received some form of ergonomic education. This education was theoretical and practical during university and clinical placement for 24/39 (61.54%); however, receiving this resulted in no difference for adherence to ergonomic recommendations. Qualitative data demonstrated high workloads, scanning patients with increased body habitus or limited mobility were potential barriers to adherence to ergonomic recommendations.Discussion: Ergonomic education occurs, yet a lack of knowledge and adherence to recommendations continues. Considerations for other potential barriers are required.Conclusion: Ensuring students adhere to ergonomic recommendations post‐graduation and identifying relevant barriers within the clinical environment are important. Future research to investigate potential barriers around ergonomic adherence is suggested.


  • Diagnostic performance of ultrasound to differentiate perforated from non‐perforated paediatric appendicitis: A narrative review

    by Nancy K. Conwell, Narelle J. Kennedy, Ann E. Quinton

    Appendicitis is the most common reason for urgent paediatric surgery, with significantly higher rates of appendiceal perforation in young children. Distinct management plans are required for perforated and non‐perforated appendicitis and thus accurate differentiation is crucial. Ultrasound is a safe imaging modality that avoids ionising radiation exposure to children and is useful for diagnosis of appendicitis. The aim of this review is to explore the diagnostic performance of ultrasound for detecting perforated paediatric appendicitis and to determine the sonographic findings useful for distinguishing perforated from non‐perforated appendicitis in the paediatric population. Ultrasound demonstrates high specificity ranging from 90% to 100%, but low sensitivity ranging from 23% to 44% for differentiating perforated from non‐perforated appendicitis in children. Sonographic findings significantly associated with perforated paediatric appendicitis include an abscess, loculated or complex intraperitoneal fluid, an appendicolith, dilated bowel and thickening of the terminal ileum, all of which demonstrate high specificity but low sensitivity. The high specificity of ultrasound indicates that it is a useful diagnostic tool to rule out perforated appendicitis and differentiate it from non‐perforated appendicitis in children.


  • Normative ultrasound data of the fetal transverse thalamic diameter derived from 18 to 22 weeks of gestation in routine second‐trimester morphology examinations

    by Pradeeba Sridar, Narelle J. Kennedy, Ann E. Quinton, Kristy Robledo, Jinman Kim, Ralph Nanan

    Introduction: The thalamus is important for a wide range of sensorimotor and neuropsychiatric functions. Departure from normal reference values of the thalamus may be a biomarker for differences in neurodevelopment outcomes and brain anomalies perinatally. Antenatal measurement of thalamus is not currently included in routine fetal ultrasound as differentiation of thalamic borders is difficult. The aim of this work was to present a method to standardise the thalamus measure and provide normative data of the fetal transverse thalamic diameter between 18 and 22 weeks of gestational age.Methods: Transverse thalamic diameter was measured by two sonographers on 1,111 stored ultrasound images at the standard transcerebellar plane. A ‘guitar’ shape representative structure is presented to demarcate the thalamic diameter. The relationship of the transverse thalamic diameter with gestational age, head circumference and transcerebellar diameter using linear regression modelling was assessed, and the mean of the thalamic diameter was calculated and plotted as a reference chart.Results: Transverse thalamic diameter increased significantly with increasing gestational age, head circumference, and transcerebellar diameter linearly, and normal range thalamic charts are presented. The guitar shape provided good reproducibility of thalamic diameter measures.Conclusion: Measuring thalamus size in antenatal ultrasound examinations with reference to normative charts could be used to assess midline brain structures and predict neurodevelopment disorders and potentially brain anomalies.


  • Open Access

    An Automated Framework for Large Scale Retrospective Analysis of Ultrasound Images

    by Pradeeba Sridar, Ashnil Kumar, Ann Quinton, Narelle June Kennedy, Ralph Nanan, Jinman Kim

    Objective: Large scale retrospective analysis of fetal ultrasound (US) data is important in the understanding of the cumulative impact of antenatal factors on offspring's health outcomes. Although the benefits are evident, there is a paucity of research into such large scale studies as it requires tedious and expensive effort in manual processing of large scale data repositories. This study presents an automated framework to facilitate retrospective analysis of large scale US data repositories. Method: Our framework consists of four modules: (1) an image classifier to distinguish the Brightness (B) -mode images; (2) a fetal image structure identifier to select US images containing user-defined fetal structures of interest (fSOI); (3) a biometry measurement algorithm to measure the fSOIs in the images and, (4) a visual evaluation module to allow clinicians to validate the outcomes. Results: We demonstrated our framework using thalamus as the fSOI from a hospital repository of more than 80,000 patients, consisting of 3,816,967 antenatal US files (DICOM objects). Our framework classified 1,869,105 B-mode images and from which 38,786 thalamus images were identified. We selected a random subset of 1290 US files with 558 B-mode (containing 19 thalamus images and the rest being other US data) and evaluated our framework performance. With the evaluation set, B-mode image classification resulted in accuracy, precision, and recall (APR) of 98.67%, 99.75% and 98.57% respectively. For fSOI identification, APR was 93.12%, 97.76% and 80.78% respectively. Conclusion: We introduced a completely automated approach designed to analyze a large scale data repository to enable retrospective clinical research.


  • The limitations of access to continuing professional development amongst Australia's rural sonographers and its effect on job satisfaction: A pilot study

    by Anouck Van Binst, Narelle Kennedy, Sonya Harland, Aamer Aziz, Ann Quinton

    Introduction: Sonographers in Australia form an important component of health care within rural and remote communities. Being remotely located brings its own set of difficulties in accessing continuing professional development (CPD). There is little research investigating the rural sonographers' experience with access to CPD and how this affects job satisfaction.Method: The purpose of this research was to investigate if limited access to CPD is experienced in the rural setting, what barriers to participation exist, and if reduced access has a negative effect on job satisfaction. Data were collected via the Australasian Sonographers Association (ASA) members' forum, inviting rural and remote sonographers to participate in an anonymous online questionnaire.Results: This study showed that various barriers to CPD participation exist, with in‐person CPD participation seen as highly valuable.Conclusion: This study opens an opportunity for further conversations on how to improve CPD access amongst rural sonographers with the possible underlying solution being increased employer support.