Krishnan Parthasarathi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Krishnan Parthasarathi has a total of 43 co-authors. Here are the top co-authors by number of shared publications:
- Jonathan Robert Clark
Department of Head and Neck Surgery Chris O'Brien Lifehouse Sydney New South Wales Australia
4 shared publications - D. S. Abdullah Al Maruf
Sydney Medical School, Faculty of Medicine and Health The University of Sydney Camperdown New South Wales Australia
3 shared publications - David Leinkram
Department of Head and Neck Surgery, Chris O'Brien Lifehouse, Sydney, NSW, Australia
3 shared publications - Innes Wise
University of Sydney
3 shared publications - Jeremy Micah Crook
Chris O'Brien Lifehouse
3 shared publications - Kai Cheng
Department of Head and Neck Surgery, Chris O'Brien Lifehouse, 119-143 Missenden Road, Camperdown, NSW 2050, Australia; Royal Prince Alfred Institute of Academic Surgery, Sydney Local Health District, 145 Missenden Road, Camperdown, NSW 2050, Australia
3 shared publications
Latest Publications
- Open Access
- 6 March 2025
- Published by Springer Nature in Research Square
Mechanobiologically-optimized non-resorbable artificial bone – a new paradigm in patient-matched scaffold-guided bone regeneration
Patient-matched scaffold guided bone regeneration (SGBR) has been poised to revolutionize the management of critical-sized bone defects due to trauma, tumors, infection, and congenital deformities. However, translation has been hampered by the focus on bioresorbable scaffolds where the rate of scaffold degradation needs to be precisely and predictably matched to the rate of new bone formation. Furthermore, resorbable ceramics and polymers require augmentation by metal plates to overcome their mechanical limitations under load. Consequently, there are no published studies using SGBR for segmental defects without metal plates, which cause stress shielding and X-ray perturbation. Even with augmentation, very few studies use animal models where the loads are comparable to humans. Segmental defects of the mandible represent one of the most challenging examples of critical-sized bone defects due to the high tensile and shear stresses encountered during mastication. The ovine mandible is an excellent model because the high and repetitive loads exceed those encountered in humans. Here, we describe the first successful long-term reconstruction of ovine segmental mandibulectomy defects using permanent, patient-matched, numerically optimized, 3D-printed, thermally toughened, plasma-treated, and selectively-laser-sintered polyetherketone gyroid scaffolds. The scaffolds house a resorbable ceramic lattice infused with a stem cell laden hydrogel and serve as an osteoinductive reservoir of calcium. Durable clinical performance and osseointegration was established in vivo and ex vivo, indicating for the first time that there is a reliable and translatable patient-matched SGBR alternative to traditional bone grafts and metal plate fixation.
- 6 March 2025
- Published by Springer Nature in Research Square
Open AccessMechanobiologically-optimized non-resorbable artificial bone – a new paradigm in patient-matched scaffold-guided bone regeneration
Patient-matched scaffold guided bone regeneration (SGBR) has been poised to revolutionize the management of critical-sized bone defects due to trauma, tumors, infection, and congenital deformities. However, translation has been hampered by the focus on bioresorbable scaffolds where the rate of scaffold degradation needs to be precisely and predictably matched to the rate of new bone formation. Furthermore, resorbable ceramics and polymers require augmentation by metal plates to overcome their mechanical limitations under load. Consequently, there are no published studies using SGBR for segmental defects without metal plates, which cause stress shielding and X-ray perturbation. Even with augmentation, very few studies use animal models where the loads are comparable to humans. Segmental defects of the mandible represent one of the most challenging examples of critical-sized bone defects due to the high tensile and shear stresses encountered during mastication. The ovine mandible is an excellent model because the high and repetitive loads exceed those encountered in humans. Here, we describe the first successful long-term reconstruction of ovine segmental mandibulectomy defects using permanent, patient-matched, numerically optimized, 3D-printed, thermally toughened, plasma-treated, and selectively-laser-sintered polyetherketone gyroid scaffolds. The scaffolds house a resorbable ceramic lattice infused with a stem cell laden hydrogel and serve as an osteoinductive reservoir of calcium. Durable clinical performance and osseointegration was established in vivo and ex vivo, indicating for the first time that there is a reliable and translatable patient-matched SGBR alternative to traditional bone grafts and metal plate fixation.
- Open Access
- 21 October 2023
- Published by MDPI AG in Bioengineering
- Vol. 10 (10) , 1233
A Comparison of In Vivo Bone Tissue Generation Using Calcium Phosphate Bone Substitutes in a Novel 3D Printed Four-Chamber Periosteal Bioreactor
Autologous bone replacement remains the preferred treatment for segmental defects of the mandible; however, it cannot replicate complex facial geometry and causes donor site morbidity. Bone tissue engineering has the potential to overcome these limitations. Various commercially available calcium phosphate-based bone substitutes (Novabone®, BioOss®, and Zengro®) are commonly used in dentistry for small bone defects around teeth and implants. However, their role in ectopic bone formation, which can later be applied as vascularized graft in a bone defect, is yet to be explored. Here, we compare the above-mentioned bone substitutes with autologous bone with the aim of selecting one for future studies of segmental mandibular repair. Six female sheep, aged 7–8 years, were implanted with 40 mm long four-chambered polyether ether ketone (PEEK) bioreactors prepared using additive manufacturing followed by plasma immersion ion implantation (PIII) to improve hydrophilicity and bioactivity. Each bioreactor was wrapped with vascularized scapular periosteum and the chambers were filled with autologous bone graft, Novabone®, BioOss®, and Zengro®, respectively. The bioreactors were implanted within a subscapular muscle pocket for either 8 weeks (two sheep), 10 weeks (two sheep), or 12 weeks (two sheep), after which they were removed and assessed by microCT and routine histology. Moderate bone formation was observed in autologous bone grafts, while low bone formation was observed in the BioOss® and Zengro® chambers. No bone formation was observed in the Novabone® chambers. Although the BioOss® and Zengro® chambers contained relatively small amounts of bone, endochondral ossification and retained hydroxyapatite suggest their potential in new bone formation in an ectopic site if a consistent supply of progenitor cells and/or growth factors can be ensured over a longer duration.
- 21 October 2023
- Published by MDPI AG in Bioengineering
- Vol. 10 (10) , 1233
Open AccessA Comparison of In Vivo Bone Tissue Generation Using Calcium Phosphate Bone Substitutes in a Novel 3D Printed Four-Chamber Periosteal Bioreactor
Autologous bone replacement remains the preferred treatment for segmental defects of the mandible; however, it cannot replicate complex facial geometry and causes donor site morbidity. Bone tissue engineering has the potential to overcome these limitations. Various commercially available calcium phosphate-based bone substitutes (Novabone®, BioOss®, and Zengro®) are commonly used in dentistry for small bone defects around teeth and implants. However, their role in ectopic bone formation, which can later be applied as vascularized graft in a bone defect, is yet to be explored. Here, we compare the above-mentioned bone substitutes with autologous bone with the aim of selecting one for future studies of segmental mandibular repair. Six female sheep, aged 7–8 years, were implanted with 40 mm long four-chambered polyether ether ketone (PEEK) bioreactors prepared using additive manufacturing followed by plasma immersion ion implantation (PIII) to improve hydrophilicity and bioactivity. Each bioreactor was wrapped with vascularized scapular periosteum and the chambers were filled with autologous bone graft, Novabone®, BioOss®, and Zengro®, respectively. The bioreactors were implanted within a subscapular muscle pocket for either 8 weeks (two sheep), 10 weeks (two sheep), or 12 weeks (two sheep), after which they were removed and assessed by microCT and routine histology. Moderate bone formation was observed in autologous bone grafts, while low bone formation was observed in the BioOss® and Zengro® chambers. No bone formation was observed in the Novabone® chambers. Although the BioOss® and Zengro® chambers contained relatively small amounts of bone, endochondral ossification and retained hydroxyapatite suggest their potential in new bone formation in an ectopic site if a consistent supply of progenitor cells and/or growth factors can be ensured over a longer duration.
- Open Access
Ex Vivo Preservation of Ovine Periosteum Using a Perfusion Bioreactor System
Periosteum is a highly vascularized membrane lining the surface of bones. It plays essential roles in bone repair following injury and reconstruction following invasive surgeries. To broaden the use of periosteum, including for augmenting in vitro bone engineering and/or in vivo bone repair, we have developed an ex vivo perfusion bioreactor system to maintain the cellular viability and metabolism of surgically resected periosteal flaps. Each specimen was placed in a 3D printed bioreactor connected to a peristaltic pump designed for the optimal flow rates of tissue perfusate. Nutrients and oxygen were perfused via the periosteal arteries to mimic physiological conditions. Biochemical assays and histological staining indicate component cell viability after perfusion for almost 4 weeks. Our work provides the proof-of-concept of ex vivo periosteum perfusion for long-term tissue preservation, paving the way for innovative bone engineering approaches that use autotransplanted periosteum to enhance in vivo bone repair.
Open AccessEx Vivo Preservation of Ovine Periosteum Using a Perfusion Bioreactor System
Periosteum is a highly vascularized membrane lining the surface of bones. It plays essential roles in bone repair following injury and reconstruction following invasive surgeries. To broaden the use of periosteum, including for augmenting in vitro bone engineering and/or in vivo bone repair, we have developed an ex vivo perfusion bioreactor system to maintain the cellular viability and metabolism of surgically resected periosteal flaps. Each specimen was placed in a 3D printed bioreactor connected to a peristaltic pump designed for the optimal flow rates of tissue perfusate. Nutrients and oxygen were perfused via the periosteal arteries to mimic physiological conditions. Biochemical assays and histological staining indicate component cell viability after perfusion for almost 4 weeks. Our work provides the proof-of-concept of ex vivo periosteum perfusion for long-term tissue preservation, paving the way for innovative bone engineering approaches that use autotransplanted periosteum to enhance in vivo bone repair.
- 31 January 2022
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 130 (1) , 133-137
Expanding the digital workflow for a prefabricated prelaminated fibula flap: A dental technique
- 31 January 2022
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 130 (1) , 133-137
Expanding the digital workflow for a prefabricated prelaminated fibula flap: A dental technique
- 1 November 2020
- Published by Elsevier in British Journal of Oral and Maxillofacial Surgery
- Vol. 58 (9) , 1208-1209
‘Yorkshireman’ temporomandibular joint discopexy: a technical note
- 1 November 2020
- Published by Elsevier in British Journal of Oral and Maxillofacial Surgery
- Vol. 58 (9) , 1208-1209
‘Yorkshireman’ temporomandibular joint discopexy: a technical note
- 1 November 2018
- Published by Elsevier in Journal of Oral and Maxillofacial Surgery
- Vol. 76 (11) , 2370-2375
Primary Assessment of the Patient With Orbital Fractures Should Include Pupillary Response and Visual Acuity Changes to Detect Occult Major Ocular Injuries
- 1 November 2018
- Published by Elsevier in Journal of Oral and Maxillofacial Surgery
- Vol. 76 (11) , 2370-2375
Primary Assessment of the Patient With Orbital Fractures Should Include Pupillary Response and Visual Acuity Changes to Detect Occult Major Ocular Injuries