Michael A. Mont
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Michael A. Mont has a total of 35 co-authors. Here are the top co-authors by number of shared publications:
Nipun Sodhi
Department of Orthopaedic Surgery, Long Island Jewish Medical Center, New Hyde Park, New York
6 shared publicationsAnton Khlopas
Department of Orthopaedic Surgery, Cleveland Clinic, Cleveland, Ohio
3 shared publications- Hiba K. Anis
Department of Orthopaedic Surgery, Cleveland Clinic Foundation, Cleveland, Ohio
2 shared publications Jaiben George
Department of Orthopaedic Surgery, Cleveland Clinic, Cleveland, Ohio
2 shared publicationsJoseph T. Moskal
Department of Orthopaedic Surgery, Carilion Clinic, Roanoke, Virginia
2 shared publicationsAli Guermazi
Quantitative Imaging Center, Boston University School of Medicine, Boston, Massachusetts
1 shared publication
Latest Publications
- 22 September 2020
- Published by Georg Thieme Verlag KG in The Journal of Hip Surgery
- Vol. 4 (03) , 117-123
Comparison of Precision for Manual versus Robotic-Assisted Total Hip Arthroplasty Performed by Fellows
Although various studies have shown that robotic-assisted total hip arthroplasty (RATHA) is associated with improved component positioning to plan and reduced intraoperative complications, there is still a learning curve for implementation even for experienced surgeons. This study assessed this learning curve for fellows during their training year, by comparing the accuracy and precision of acetabular component positioning, leg length, component offset, and center of rotation between manual THA (MTHA) and RATHA. Six fresh-frozen lower extremity specimens were utilized for surgical procedures performed by two adult reconstruction fellows who were halfway through their training year. The specimens were randomized to undergo one side with manual instrumentation and the contralateral side with RATHA. The final intraoperative surgical plan for rotation, cup orientation, leg length, and offset values were recorded and compared with the actual values measured by computed tomography (CT) scan. Using pre- and postoperative CT scans, the RATHA group was then compared with the MTHA group for accuracy and precision to plan. To assess differences in standard deviations of each measurement, 2-variances testing was performed using α = 0.05. To assess differences in central tendencies of each measurement for each group, Mann–Whitney U tests were performed using α = 0.05. RATHA exhibited significantly (p < 0.05) greater accuracy and precision to plan compared with MTHA in shell version (2.3 ± 1.2° vs. 7.8 ± 4.6°), shell inclination (2.1 ± 1.2° vs. 7.2 ± 3.2), and leg length discrepancy (0.8 ± 0.8 mm vs. 6.4 ± 3.7 mm). Center of head rotation was reported for each anatomical plane. There was no statistical difference in distance from original center of head rotation when considering the superoinferior, mediolateral, and anteroposterior planes as well as when combined as a total deviation in all three planes. The use of CT-guided preoperative planning and intraoperative robotic technology can help surgeons achieve desired implant placement. Results from this study indicate that with limited RATHA experience, surgeons in fellowship training were able to place THA components more accurately and precisely to plan for several important parameters compared with MTHA, namely shell inclination, shell anteversion, and leg length discrepancy.
- 22 September 2020
- Published by Georg Thieme Verlag KG in The Journal of Hip Surgery
- Vol. 4 (03) , 117-123
Comparison of Precision for Manual versus Robotic-Assisted Total Hip Arthroplasty Performed by Fellows
Although various studies have shown that robotic-assisted total hip arthroplasty (RATHA) is associated with improved component positioning to plan and reduced intraoperative complications, there is still a learning curve for implementation even for experienced surgeons. This study assessed this learning curve for fellows during their training year, by comparing the accuracy and precision of acetabular component positioning, leg length, component offset, and center of rotation between manual THA (MTHA) and RATHA. Six fresh-frozen lower extremity specimens were utilized for surgical procedures performed by two adult reconstruction fellows who were halfway through their training year. The specimens were randomized to undergo one side with manual instrumentation and the contralateral side with RATHA. The final intraoperative surgical plan for rotation, cup orientation, leg length, and offset values were recorded and compared with the actual values measured by computed tomography (CT) scan. Using pre- and postoperative CT scans, the RATHA group was then compared with the MTHA group for accuracy and precision to plan. To assess differences in standard deviations of each measurement, 2-variances testing was performed using α = 0.05. To assess differences in central tendencies of each measurement for each group, Mann–Whitney U tests were performed using α = 0.05. RATHA exhibited significantly (p < 0.05) greater accuracy and precision to plan compared with MTHA in shell version (2.3 ± 1.2° vs. 7.8 ± 4.6°), shell inclination (2.1 ± 1.2° vs. 7.2 ± 3.2), and leg length discrepancy (0.8 ± 0.8 mm vs. 6.4 ± 3.7 mm). Center of head rotation was reported for each anatomical plane. There was no statistical difference in distance from original center of head rotation when considering the superoinferior, mediolateral, and anteroposterior planes as well as when combined as a total deviation in all three planes. The use of CT-guided preoperative planning and intraoperative robotic technology can help surgeons achieve desired implant placement. Results from this study indicate that with limited RATHA experience, surgeons in fellowship training were able to place THA components more accurately and precisely to plan for several important parameters compared with MTHA, namely shell inclination, shell anteversion, and leg length discrepancy.
- 4 January 2019
- Published by Georg Thieme Verlag KG in The Journal of Knee Surgery
- Vol. 33 (02) , 167-172
Results of a Phase II Study to Determine the Efficacy and Safety of Genetically Engineered Allogeneic Human Chondrocytes Expressing TGF-β1
Genetically engineered chondrocytes virally transduced with a transforming growth factor (TGF)-β1 (TG-C [TissueGene-C]) expression vector have been shown to have potential benefits in the nonoperative management of knee osteoarthritis. Previous literature has reported on safe dosages of TG-C. Therefore, the purpose of this study was to evaluate the Phase II results and a 24-month efficacy of this injectable mixture compared with placebo in patients with Kellgren–Lawrence (K–L) grade III knee osteoarthritis. Specifically, we assessed (1) functional outcomes, (2) pain scores, (3) adverse events (AEs), and (4) magnetic resonance imaging (MRIs) findings. We performed a multicenter, double-blinded, placebo-controlled, and randomized study of adults who had K–L grade III knee osteoarthritis. A total of 102 patients were 2:1 randomized to TG-C at a dose of 3.0 × 107 cells, or placebo injections between May 1, 2011 and October 31, 2012. Outcomes analyzed were knee joint function, pain, quality of life, adverse events, and MRI findings using the whole-organ magnetic resonance imaging score (WORMS) system. There were significant improvements in the International Knee Documentation Committee (IKDC) and visual analogue scale (VAS) scores in the TG-C cohort, when compared with the placebo cohort at weeks 12, 52, 72, and 104 (p < 0.05). No severe AEs were observed. Common AEs were arthralgia, joint inflammation, and joint effusion which were similar between both cohorts. Whole-knee MRIs at 12 months showed less progression of cartilage damage, infrapatellar fat pad-synovitis, and effusion-synovitis in the TG-C cohort. Patients who received TG-C had significant improvements in IKDC and VAS scores. These patients also reported less severe and frequent pain. Additionally, fewer patients treated with TG-C showed progression of cartilage damage, as well as less progression of infrapatellar fat pad synovitis and effusion-synovitis. Furthermore, treatment with TG-C was generally well tolerated with minor AEs. Therefore, based on these results, TG-C appears to be a safe and effective modality for the management of K–L grade III osteoarthritis.
- 4 January 2019
- Published by Georg Thieme Verlag KG in The Journal of Knee Surgery
- Vol. 33 (02) , 167-172
Results of a Phase II Study to Determine the Efficacy and Safety of Genetically Engineered Allogeneic Human Chondrocytes Expressing TGF-β1
Genetically engineered chondrocytes virally transduced with a transforming growth factor (TGF)-β1 (TG-C [TissueGene-C]) expression vector have been shown to have potential benefits in the nonoperative management of knee osteoarthritis. Previous literature has reported on safe dosages of TG-C. Therefore, the purpose of this study was to evaluate the Phase II results and a 24-month efficacy of this injectable mixture compared with placebo in patients with Kellgren–Lawrence (K–L) grade III knee osteoarthritis. Specifically, we assessed (1) functional outcomes, (2) pain scores, (3) adverse events (AEs), and (4) magnetic resonance imaging (MRIs) findings. We performed a multicenter, double-blinded, placebo-controlled, and randomized study of adults who had K–L grade III knee osteoarthritis. A total of 102 patients were 2:1 randomized to TG-C at a dose of 3.0 × 107 cells, or placebo injections between May 1, 2011 and October 31, 2012. Outcomes analyzed were knee joint function, pain, quality of life, adverse events, and MRI findings using the whole-organ magnetic resonance imaging score (WORMS) system. There were significant improvements in the International Knee Documentation Committee (IKDC) and visual analogue scale (VAS) scores in the TG-C cohort, when compared with the placebo cohort at weeks 12, 52, 72, and 104 (p < 0.05). No severe AEs were observed. Common AEs were arthralgia, joint inflammation, and joint effusion which were similar between both cohorts. Whole-knee MRIs at 12 months showed less progression of cartilage damage, infrapatellar fat pad-synovitis, and effusion-synovitis in the TG-C cohort. Patients who received TG-C had significant improvements in IKDC and VAS scores. These patients also reported less severe and frequent pain. Additionally, fewer patients treated with TG-C showed progression of cartilage damage, as well as less progression of infrapatellar fat pad synovitis and effusion-synovitis. Furthermore, treatment with TG-C was generally well tolerated with minor AEs. Therefore, based on these results, TG-C appears to be a safe and effective modality for the management of K–L grade III osteoarthritis.
- 7 September 2018
- Published by Georg Thieme Verlag KG in The Journal of Knee Surgery
- Vol. 31 (10) , 928-933
Incidence of Drug Abuse in Revision Total Knee Arthroplasty Population
Substance abuse can have strong negative impacts on surgical outcomes. Therefore, this study assessed the effects of drug abuse in total knee arthroplasty (TKA) patients. Specifically, we identified revision TKA (RTKA): (1) incidence, (2) causes, (3) time to revision, and (4) patient demographics in patients with a history of drug abuse. The Medicare database within the PearlDiver Supercomputer (Warsaw, IN) was queried to identify 2,159,221 TKAs performed between 2005 and 2012. Drug abuse was subdivided into cocaine, cannabis, opioids, sedatives/hypnotics/anxiolytics (SHA), amphetamines, and alcohol abusers. The effect of drug use on the incidence and cause for RTKA, time to revision, as well as patient demographics were correlated using multivariate, analysis of variance, and regression analyses. There was a significant increase in the number of primary TKAs in cocaine (p = 0.011), cannabis (p < 0.001), opioid (p < 0.001), SHA (p < 0.001), amphetamine (p < 0.001), and alcohol (p < 0.001) users. Amphetamine users had the fastest mean time to revision (691 days, standard deviation: 679 days). At 30-, 90-day, and 6-month postoperative, cocaine had the highest proportion of patients requiring RTKA (7, 12, and 20%, respectively), and at 1-year alcohol abusers (38%, p < 0.001). Infection was the most common cause of revision in all drug abuse/dependent cohorts. Age distributions varied significantly by group for primary TKA (p < 0.001). Comorbidity status was similar in all RTKA patients as determined by comparison of the mean Charlson comorbidity index scores (p = 0.091). Based on these results, drug abuse patients are at increased risk for RTKA. These high-risk patients should, therefore, be appropriately risk stratified and receive comprehensive postoperative pain management.
- 7 September 2018
- Published by Georg Thieme Verlag KG in The Journal of Knee Surgery
- Vol. 31 (10) , 928-933
Incidence of Drug Abuse in Revision Total Knee Arthroplasty Population
Substance abuse can have strong negative impacts on surgical outcomes. Therefore, this study assessed the effects of drug abuse in total knee arthroplasty (TKA) patients. Specifically, we identified revision TKA (RTKA): (1) incidence, (2) causes, (3) time to revision, and (4) patient demographics in patients with a history of drug abuse. The Medicare database within the PearlDiver Supercomputer (Warsaw, IN) was queried to identify 2,159,221 TKAs performed between 2005 and 2012. Drug abuse was subdivided into cocaine, cannabis, opioids, sedatives/hypnotics/anxiolytics (SHA), amphetamines, and alcohol abusers. The effect of drug use on the incidence and cause for RTKA, time to revision, as well as patient demographics were correlated using multivariate, analysis of variance, and regression analyses. There was a significant increase in the number of primary TKAs in cocaine (p = 0.011), cannabis (p < 0.001), opioid (p < 0.001), SHA (p < 0.001), amphetamine (p < 0.001), and alcohol (p < 0.001) users. Amphetamine users had the fastest mean time to revision (691 days, standard deviation: 679 days). At 30-, 90-day, and 6-month postoperative, cocaine had the highest proportion of patients requiring RTKA (7, 12, and 20%, respectively), and at 1-year alcohol abusers (38%, p < 0.001). Infection was the most common cause of revision in all drug abuse/dependent cohorts. Age distributions varied significantly by group for primary TKA (p < 0.001). Comorbidity status was similar in all RTKA patients as determined by comparison of the mean Charlson comorbidity index scores (p = 0.091). Based on these results, drug abuse patients are at increased risk for RTKA. These high-risk patients should, therefore, be appropriately risk stratified and receive comprehensive postoperative pain management.
- 29 August 2018
- Published by Georg Thieme Verlag KG in The Journal of Knee Surgery
- Vol. 31 (10) , 940-945
Operative Time, Length of Stay, Short-Term Readmission, and Complications after Hinged Primary Total Knee Arthroplasty: A Propensity Score Matched Analysis
Despite the wide utilization of total knee arthroplasty (TKA), it can be technically challenging to perform in patients who have concomitant bone loss, ligamentous laxity, or high-grade deformity, whether in a revision situation or due to a primary pathology. Therefore, hinged knee prostheses have been developed to provide more stable fixation in these situations. The purpose of this study was to compare the short-term peri- and postoperative outcomes of patients undergoing primary TKA with and without hinged prosthesis. Specifically, we compared (1) mean operative times, (2) lengths of stay (LOS), (3) 30-day readmissions, and (4) complications. The American College of Surgeons National Surgical Quality Improvement Program database was queried to identify hinged TKAs and 99 procedures were included. They were matched in a 1:3 ratio to primary TKAs without a hinged prosthesis using propensity score matching. Operative time, LOS, discharge disposition, 30-day readmissions, and complications were compared. Adjusted odds ratios (OR) were also calculated. The operative time was significantly higher in hinged cohort compared with the nonhinged cohort (mean difference [MD] = 22 minutes; range, 10–34 minutes, p < 0.001). There were no significant differences between hinged and nonhinged TKAs with respect to LOS (MD= 0.61 days, range, –0.07–1.30 days, p = 0.080), discharge disposition (OR = 1.09, 95% confidence interval [CI], 0.66–1.84), readmissions (OR = 2.67, 95% CI, 0.84–8.24), and any complications (OR = 1.13, 95% CI, 0.55–2.19). Not surprisingly, primary TKAs with hinged prostheses had increased operative times, but had similar LOS, discharge dispositions, and 30-day rates of readmission and complications when compared with TKAs without a hinged prosthesis. One potential contributing factor to the increased operating time is that patients who receive a hinged implant tend to present with more severe deformities. It is reassuring to know that early outcomes were similar between both cohorts (although we await longer follow-up studies), and that hinged implants can be considered in these difficult to treat patients.
- 29 August 2018
- Published by Georg Thieme Verlag KG in The Journal of Knee Surgery
- Vol. 31 (10) , 940-945
Operative Time, Length of Stay, Short-Term Readmission, and Complications after Hinged Primary Total Knee Arthroplasty: A Propensity Score Matched Analysis
Despite the wide utilization of total knee arthroplasty (TKA), it can be technically challenging to perform in patients who have concomitant bone loss, ligamentous laxity, or high-grade deformity, whether in a revision situation or due to a primary pathology. Therefore, hinged knee prostheses have been developed to provide more stable fixation in these situations. The purpose of this study was to compare the short-term peri- and postoperative outcomes of patients undergoing primary TKA with and without hinged prosthesis. Specifically, we compared (1) mean operative times, (2) lengths of stay (LOS), (3) 30-day readmissions, and (4) complications. The American College of Surgeons National Surgical Quality Improvement Program database was queried to identify hinged TKAs and 99 procedures were included. They were matched in a 1:3 ratio to primary TKAs without a hinged prosthesis using propensity score matching. Operative time, LOS, discharge disposition, 30-day readmissions, and complications were compared. Adjusted odds ratios (OR) were also calculated. The operative time was significantly higher in hinged cohort compared with the nonhinged cohort (mean difference [MD] = 22 minutes; range, 10–34 minutes, p < 0.001). There were no significant differences between hinged and nonhinged TKAs with respect to LOS (MD= 0.61 days, range, –0.07–1.30 days, p = 0.080), discharge disposition (OR = 1.09, 95% confidence interval [CI], 0.66–1.84), readmissions (OR = 2.67, 95% CI, 0.84–8.24), and any complications (OR = 1.13, 95% CI, 0.55–2.19). Not surprisingly, primary TKAs with hinged prostheses had increased operative times, but had similar LOS, discharge dispositions, and 30-day rates of readmission and complications when compared with TKAs without a hinged prosthesis. One potential contributing factor to the increased operating time is that patients who receive a hinged implant tend to present with more severe deformities. It is reassuring to know that early outcomes were similar between both cohorts (although we await longer follow-up studies), and that hinged implants can be considered in these difficult to treat patients.
- 29 August 2018
- Published by Georg Thieme Verlag KG in The Journal of Knee Surgery
- Vol. 31 (10) , 934-939
Is ICD-9 Coding of Morbid Obesity Reliable in Patients Undergoing Total Knee Arthroplasty?
Morbid obesity is considered to have a stronger association with complications after total knee arthroplasty (TKA). Although the impact of obesity coding errors has been previously reported, the extent of coding inaccuracies with respect to morbid obesity is unclear. Therefore, the purpose of this study was to assess (1) the utility of coding in identifying morbid obesity and (2) the effects of morbid obesity on 90-day complications after TKA when morbid obesity was defined by both body mass index (BMI) and International Classification of Diseases 9th edition (ICD-9) coding. A total of 18,030 primary TKAs performed at a single institution from 2004 to 2014 were identified. Patients were defined as morbidly obese based on ICD-9 codes or by BMI recorded in the electronic medical record (EMR). Patients were defined as obese (ICD-9 codes 278.0, 278.00, 278.01, 278.03, 649.10–14, 793.91, V85.30–39, V85.41–45, V85.54) or morbidly obese (278.01, V85.41–45) by ICD-9 codes. Patient EMRs were also reviewed to identify obese and morbidly obese patients (BMI cutoffs of 30 and 40 kg/m2, respectively). Complications between the cohorts were compared. Sensitivity and specificity were also calculated. Among the 2,880 surgeries performed in morbidly obese patients, a code for obesity was present in 1,618 (56.2%) surgeries, but only 57.9% (937) of these patients had a code specific for morbid obesity, with the rest having a code not specifying morbid obesity. The sensitivity and specificity of obesity coding were 34.5 and 96.0%, while that of morbid obesity were 32.5 and 96.7%, respectively (area under curve: 0.65 vs. 0.65, p = 0.214). A higher rate of complications was noted when patients were defined as morbidly obese by ICD-9 as when defined by EMR-reported BMI. Although morbidly obese patients are more likely to have a code for obesity compared with obese patients, these patients may not be correctly identified as morbidly obese due to a lack of specificity in the codes. These errors may lead to inadequate reimbursements, and may also overestimate the effect of morbid obesity on complications.
- 29 August 2018
- Published by Georg Thieme Verlag KG in The Journal of Knee Surgery
- Vol. 31 (10) , 934-939
Is ICD-9 Coding of Morbid Obesity Reliable in Patients Undergoing Total Knee Arthroplasty?
Morbid obesity is considered to have a stronger association with complications after total knee arthroplasty (TKA). Although the impact of obesity coding errors has been previously reported, the extent of coding inaccuracies with respect to morbid obesity is unclear. Therefore, the purpose of this study was to assess (1) the utility of coding in identifying morbid obesity and (2) the effects of morbid obesity on 90-day complications after TKA when morbid obesity was defined by both body mass index (BMI) and International Classification of Diseases 9th edition (ICD-9) coding. A total of 18,030 primary TKAs performed at a single institution from 2004 to 2014 were identified. Patients were defined as morbidly obese based on ICD-9 codes or by BMI recorded in the electronic medical record (EMR). Patients were defined as obese (ICD-9 codes 278.0, 278.00, 278.01, 278.03, 649.10–14, 793.91, V85.30–39, V85.41–45, V85.54) or morbidly obese (278.01, V85.41–45) by ICD-9 codes. Patient EMRs were also reviewed to identify obese and morbidly obese patients (BMI cutoffs of 30 and 40 kg/m2, respectively). Complications between the cohorts were compared. Sensitivity and specificity were also calculated. Among the 2,880 surgeries performed in morbidly obese patients, a code for obesity was present in 1,618 (56.2%) surgeries, but only 57.9% (937) of these patients had a code specific for morbid obesity, with the rest having a code not specifying morbid obesity. The sensitivity and specificity of obesity coding were 34.5 and 96.0%, while that of morbid obesity were 32.5 and 96.7%, respectively (area under curve: 0.65 vs. 0.65, p = 0.214). A higher rate of complications was noted when patients were defined as morbidly obese by ICD-9 as when defined by EMR-reported BMI. Although morbidly obese patients are more likely to have a code for obesity compared with obese patients, these patients may not be correctly identified as morbidly obese due to a lack of specificity in the codes. These errors may lead to inadequate reimbursements, and may also overestimate the effect of morbid obesity on complications.
- Top Cited Papers
- 1 May 2018
- Published by Georg Thieme Verlag KG in The Journal of Knee Surgery
- Vol. 32 (03) , 239-250
Robotic-Arm Assisted Total Knee Arthroplasty Demonstrated Greater Accuracy and Precision to Plan Compared with Manual Techniques
This study determined if robotic-arm assisted total knee arthroplasty (RATKA) allows for more accurate and precise bone cuts and component position to plan compared with manual total knee arthroplasty (MTKA). Specifically, we assessed the following: (1) final bone cuts, (2) final component position, and (3) a potential learning curve for RATKA. On six cadaver specimens (12 knees), a MTKA and RATKA were performed on the left and right knees, respectively. Bone-cut and final-component positioning errors relative to preoperative plans were compared. Median errors and standard deviations (SDs) in the sagittal, coronal, and axial planes were compared. Median values of the absolute deviation from plan defined the accuracy to plan. SDs described the precision to plan. RATKA bone cuts were as or more accurate to plan based on nominal median values in 11 out of 12 measurements. RATKA bone cuts were more precise to plan in 8 out of 12 measurements (p ≤ 0.05). RATKA final component positions were as or more accurate to plan based on median values in five out of five measurements. RATKA final component positions were more precise to plan in four out of five measurements (p ≤ 0.05). Stacked error results from all cuts and implant positions for each specimen in procedural order showed that RATKA error was less than MTKA error. Although this study analyzed a small number of cadaver specimens, there were clear differences that separated these two groups. When compared with MTKA, RATKA demonstrated more accurate and precise bone cuts and implant positioning to plan.
- 1 May 2018
- Published by Georg Thieme Verlag KG in The Journal of Knee Surgery
- Vol. 32 (03) , 239-250
Top Cited PapersRobotic-Arm Assisted Total Knee Arthroplasty Demonstrated Greater Accuracy and Precision to Plan Compared with Manual Techniques
This study determined if robotic-arm assisted total knee arthroplasty (RATKA) allows for more accurate and precise bone cuts and component position to plan compared with manual total knee arthroplasty (MTKA). Specifically, we assessed the following: (1) final bone cuts, (2) final component position, and (3) a potential learning curve for RATKA. On six cadaver specimens (12 knees), a MTKA and RATKA were performed on the left and right knees, respectively. Bone-cut and final-component positioning errors relative to preoperative plans were compared. Median errors and standard deviations (SDs) in the sagittal, coronal, and axial planes were compared. Median values of the absolute deviation from plan defined the accuracy to plan. SDs described the precision to plan. RATKA bone cuts were as or more accurate to plan based on nominal median values in 11 out of 12 measurements. RATKA bone cuts were more precise to plan in 8 out of 12 measurements (p ≤ 0.05). RATKA final component positions were as or more accurate to plan based on median values in five out of five measurements. RATKA final component positions were more precise to plan in four out of five measurements (p ≤ 0.05). Stacked error results from all cuts and implant positions for each specimen in procedural order showed that RATKA error was less than MTKA error. Although this study analyzed a small number of cadaver specimens, there were clear differences that separated these two groups. When compared with MTKA, RATKA demonstrated more accurate and precise bone cuts and implant positioning to plan.