Hadi Asady
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Hadi Asady has a total of 46 co-authors. Here are the top co-authors by number of shared publications:
- Mahmoud Yousefifard
Physiology Research Center, Iran University of Medical Sciences, Tehran, Iran
9 shared publications - Mostafa Hosseini
Tehran University of Medical Sciences
9 shared publications Masoud Baikpour
Department of Medicine, School of Medicine, Tehran University of Medical Sciences, Tehran, Iran
6 shared publicationsParisa Ghelichkhani
Department of Intensive Care Nursing, School of Nursing and Midwifery, Tehran University of Medical Sciences, Tehran, Iran
5 shared publications- Saeed Safari
Proteomics Research Center Shahid Beheshti University of Medical Sciences Tehran Iran
5 shared publications Ali Moghadas Jafari
Department of Emergency Medicine, Bushehr University of Medical Sciences, Bushehr, Iran
3 shared publications
Latest Publications
- Open Access
- 20 October 2024
- Published by Academic World Research in Medical Journal of the Islamic Republic Of Iran
- Vol. 38 (1) , 1166-1172
Effort-Reward Imbalance and Low Back Pain Among Industrial Workers: A Cross-sectional Study
Background: Low back pain (LBP) in workers is a leading cause of disability and loss of work time, adversely affecting job performance and overall well-being. The primary objective of this study was to evaluate the potential role of effort-reward imbalance (ERI) as a risk factor for the development of LBP among workers. ...
- 20 October 2024
- Published by Academic World Research in Medical Journal of the Islamic Republic Of Iran
- Vol. 38 (1) , 1166-1172
Open AccessEffort-Reward Imbalance and Low Back Pain Among Industrial Workers: A Cross-sectional Study
Background: Low back pain (LBP) in workers is a leading cause of disability and loss of work time, adversely affecting job performance and overall well-being. The primary objective of this study was to evaluate the potential role of effort-reward imbalance (ERI) as a risk factor for the development of LBP among workers. ...
- Open Access
- 31 December 2022
- Published by DoNotEdit
- Vol. 10 (2) , 139-144
Determining the Level of Hospital Risk in Mashhad by the Method of Safety and Occupational Health Assessment in the Hospital
Background and Objective: Hospitals are one of the most important organizations in the healthcare system. Risk assessment is a tool to control risks, and risk management in hospitals is of great help in the reduction of the risk of hazards and hospital accidents. The present study aimed to evaluate the safety ...
- 31 December 2022
- Published by DoNotEdit
- Vol. 10 (2) , 139-144
Open AccessDetermining the Level of Hospital Risk in Mashhad by the Method of Safety and Occupational Health Assessment in the Hospital
Background and Objective: Hospitals are one of the most important organizations in the healthcare system. Risk assessment is a tool to control risks, and risk management in hospitals is of great help in the reduction of the risk of hazards and hospital accidents. The present study aimed to evaluate the safety ...
- Open Access
- 2 May 2018
- Published by Korean Society of Occupational & Environmental Medicine in Annals of Occupational and Environmental Medicine
- Vol. 30 (1) , 29
Risk factors of fatal occupational accidents in Iran
Asady H, et al. Ann Occup Environ Med. 2018 Dec;30(1):29. https://doi.org/10.1186/s40557-018-0241-0
- 2 May 2018
- Published by Korean Society of Occupational & Environmental Medicine in Annals of Occupational and Environmental Medicine
- Vol. 30 (1) , 29
Open AccessRisk factors of fatal occupational accidents in Iran
Asady H, et al. Ann Occup Environ Med. 2018 Dec;30(1):29. https://doi.org/10.1186/s40557-018-0241-0
- Open Access
- 1 December 2016
- Vol. 4 (1) , 1-10
Screening Performance Characteristic of Ultrasonography and Radiography in Detection of Pleural Effusion; a Meta-Analysis
Introduction: The role of ultrasonography in detection of pleural effusion has long been a subject of interest but controversial results have been reported. Accordingly, this study aims to conduct a systematic review of the available literature on diagnostic value of ultrasonography and radiography in detection of pleural effusion through a meta-analytic approach. Methods: An extended search was done in databases of Medline, EMBASE, ISI Web of Knowledge, Scopus, Cochrane Library, and ProQuest. Two reviewers independently extracted the data and assessed the quality of the articles. Meta-analysis was performed using a mixed-effects binary regression model. Finally, subgroup analysis was carried out in order to find the sources of heterogeneity between the included studies. Results: 12 studies were included in this meta-analysis (1554 subjects, 58.6% male). Pooled sensitivity of ultrasonography in detection of pleural effusion was 0.94 (95% CI: 0.88-0.97; I2= 84.23, p<0.001) and its pooled specificity was calculated to be 0.98 (95% CI: 0.92-1.0; I2= 88.65, p<0.001), while sensitivity and specificity of chest radiography were 0.51 (95% CI: 0.33-0.68; I2=91.76, p<0.001) and 0.91 (95% CI: 0.68-0.98; I2= 92.86, p<0.001), respectively. Sensitivity of ultrasonography was found to be higher when the procedure was carried out by an intensivist or a radiologist using 5-10 MHz transducers. Conclusion: Chest ultrasonography, as a screening tool, has a higher diagnostic accuracy in identification of plural effusion compared to radiography. The sensitivity of this imaging modality was found to be higher when performed by a radiologist or an intensivist and using 5-10MHz probes.
- 1 December 2016
- Vol. 4 (1) , 1-10
Open AccessScreening Performance Characteristic of Ultrasonography and Radiography in Detection of Pleural Effusion; a Meta-Analysis
Introduction: The role of ultrasonography in detection of pleural effusion has long been a subject of interest but controversial results have been reported. Accordingly, this study aims to conduct a systematic review of the available literature on diagnostic value of ultrasonography and radiography in detection of pleural effusion through a meta-analytic approach. Methods: An extended search was done in databases of Medline, EMBASE, ISI Web of Knowledge, Scopus, Cochrane Library, and ProQuest. Two reviewers independently extracted the data and assessed the quality of the articles. Meta-analysis was performed using a mixed-effects binary regression model. Finally, subgroup analysis was carried out in order to find the sources of heterogeneity between the included studies. Results: 12 studies were included in this meta-analysis (1554 subjects, 58.6% male). Pooled sensitivity of ultrasonography in detection of pleural effusion was 0.94 (95% CI: 0.88-0.97; I2= 84.23, p<0.001) and its pooled specificity was calculated to be 0.98 (95% CI: 0.92-1.0; I2= 88.65, p<0.001), while sensitivity and specificity of chest radiography were 0.51 (95% CI: 0.33-0.68; I2=91.76, p<0.001) and 0.91 (95% CI: 0.68-0.98; I2= 92.86, p<0.001), respectively. Sensitivity of ultrasonography was found to be higher when the procedure was carried out by an intensivist or a radiologist using 5-10 MHz transducers. Conclusion: Chest ultrasonography, as a screening tool, has a higher diagnostic accuracy in identification of plural effusion compared to radiography. The sensitivity of this imaging modality was found to be higher when performed by a radiologist or an intensivist and using 5-10MHz probes.
- Open Access
- 1 June 2016
- Vol. 4 (3) , 116-126
Application of Ultrasonography and Radiography in Detection of Hemothorax; a Systematic Review and Meta-Analysis
Introduction: Hemothorax is one of the most prevalent injuries caused by thoracic traumas. Early detection and treatment of this injury is of utmost importance in prognosis of the patient, but there are still controversial debates on the diagnostic value of imaging techniques in detection of hemothorax. Therefore, the present study aimed to evaluate the diagnostic value of chest ultrasonography and radiography in detection of hemothorax through a systematic review and meta-analysis. Methods: Two independent reviewers performed an extended systematic search in databases of Medline, EMBASE, ISI Web of Knowledge, Scopus, Cochrane Library, and ProQuest. Data were extract and quality of the relevant studies were assessed. The number of true positive, false positive, true negative and false negative cases were extracted and screening performance characteristics of two imaging techniques were calculated using a mixed-effects binary regression model. Results: Data from 12 studies were extracted and included in the meta-analysis (7361 patients, 77.1% male). Pooled sensitivity and specificity of ultrasonography in detection of hemothorax were 0.67 (95% CI: 0.41-0.86; I2=68.38, p<0.001) and 0.99 (95% CI: 0.95-1.0; I2=88.16, p<0.001), respectively. These measures for radiography were 0.54 (95% CI: 0.33-0.75; I2=92.85, p<0.001) and 0.99 (95% CI: 0.94-1.0; I2=99.22, p<0.001), respectively. Subgroup analysis found operator of the ultrasonography device, frequency of the transducer and sample size to be important sources of heterogeneity of included studies. Conclusion: The results of this study showed that although the sensitivity of ultrasonography in detection of hemothorax is relatively higher than radiography, but it is still at a moderate level (0.67%). The specificity of both imaging modalities were found to be at an excellent level in this regard. The screening characteristics of ultrasonography was found to be influenced of the operator and frequency of transducer.
- 1 June 2016
- Vol. 4 (3) , 116-126
Open AccessApplication of Ultrasonography and Radiography in Detection of Hemothorax; a Systematic Review and Meta-Analysis
Introduction: Hemothorax is one of the most prevalent injuries caused by thoracic traumas. Early detection and treatment of this injury is of utmost importance in prognosis of the patient, but there are still controversial debates on the diagnostic value of imaging techniques in detection of hemothorax. Therefore, the present study aimed to evaluate the diagnostic value of chest ultrasonography and radiography in detection of hemothorax through a systematic review and meta-analysis. Methods: Two independent reviewers performed an extended systematic search in databases of Medline, EMBASE, ISI Web of Knowledge, Scopus, Cochrane Library, and ProQuest. Data were extract and quality of the relevant studies were assessed. The number of true positive, false positive, true negative and false negative cases were extracted and screening performance characteristics of two imaging techniques were calculated using a mixed-effects binary regression model. Results: Data from 12 studies were extracted and included in the meta-analysis (7361 patients, 77.1% male). Pooled sensitivity and specificity of ultrasonography in detection of hemothorax were 0.67 (95% CI: 0.41-0.86; I2=68.38, p<0.001) and 0.99 (95% CI: 0.95-1.0; I2=88.16, p<0.001), respectively. These measures for radiography were 0.54 (95% CI: 0.33-0.75; I2=92.85, p<0.001) and 0.99 (95% CI: 0.94-1.0; I2=99.22, p<0.001), respectively. Subgroup analysis found operator of the ultrasonography device, frequency of the transducer and sample size to be important sources of heterogeneity of included studies. Conclusion: The results of this study showed that although the sensitivity of ultrasonography in detection of hemothorax is relatively higher than radiography, but it is still at a moderate level (0.67%). The specificity of both imaging modalities were found to be at an excellent level in this regard. The screening characteristics of ultrasonography was found to be influenced of the operator and frequency of transducer.
- 1 May 2016
- Published by Elsevier in Neuroscience
- Vol. 322, 377-397
Neural stem/progenitor cell transplantation for spinal cord injury treatment; A systematic review and meta-analysis
- 1 May 2016
- Published by Elsevier in Neuroscience
- Vol. 322, 377-397
Neural stem/progenitor cell transplantation for spinal cord injury treatment; A systematic review and meta-analysis
- 28 April 2016
- Published by Wiley in Journal of Gastroenterology and Hepatology
- Vol. 31 (5) , 929-935
The value of 18F‐fluorodeoxyglucose positron emission tomography for prediction of treatment response in gastrointestinal stromal tumors: a systematic review and meta‐analysis
BackgroundEarly detection of response to treatment is critically important in gastrointestinal stromal tumors (GIST). Therefore, the present systematic review and meta-analysis assessed the value of (18)f-fluorodeoxyglucose positron emission tomography ((18)FDG-PET) on prediction of therapeutic response of GIST patients to systemic treatments. MethodsThe literature search was conducted using PubMed, SCOPUS, Cochrane, and Google Scholar databases, and review article references. Eligible articles were defined as studies included confirmed GIST patients who underwent (18)FDG-PET as well as assessing the screening role of it. ResultsFinally, 21 relevant articles were included. The analysis showed the pooled sensitivity and specificity of 18FDG-PET in evaluation of response to treatment of GIST patient were 0.90 (95% CI: 0.85-0.94; I-2=52.59, P=0.001) and 0.62 (95% CI: 0.49-0.75; I-2=69.7, P=0.001), respectively. In addition, the pooled prognostic odds ratio of (18)FDG-PET for was 14.99 (95% CI, 6.42-34.99; I-2=100.0, P<0.001). The Meta regression showed that sensitivity of (18)FDG-PET was higher if the sample size of study was equal or more than 30 cases (sensitivity=0.93; 95% CI: 0.89-0.97), when using PET/CT (sensitivity=0.92; 95% CI: 0.89-0.97), and self-design criteria (sensitivity=0.93; 95% CI: 0.87-1.0). ConclusionThe present meta-analysis showed (18)FDG-PET has a significant value in predicting treatment response in GIST patients.
- 28 April 2016
- Published by Wiley in Journal of Gastroenterology and Hepatology
- Vol. 31 (5) , 929-935
The value of 18F‐fluorodeoxyglucose positron emission tomography for prediction of treatment response in gastrointestinal stromal tumors: a systematic review and meta‐analysis
BackgroundEarly detection of response to treatment is critically important in gastrointestinal stromal tumors (GIST). Therefore, the present systematic review and meta-analysis assessed the value of (18)f-fluorodeoxyglucose positron emission tomography ((18)FDG-PET) on prediction of therapeutic response of GIST patients to systemic treatments. MethodsThe literature search was conducted using PubMed, SCOPUS, Cochrane, and Google Scholar databases, and review article references. Eligible articles were defined as studies included confirmed GIST patients who underwent (18)FDG-PET as well as assessing the screening role of it. ResultsFinally, 21 relevant articles were included. The analysis showed the pooled sensitivity and specificity of 18FDG-PET in evaluation of response to treatment of GIST patient were 0.90 (95% CI: 0.85-0.94; I-2=52.59, P=0.001) and 0.62 (95% CI: 0.49-0.75; I-2=69.7, P=0.001), respectively. In addition, the pooled prognostic odds ratio of (18)FDG-PET for was 14.99 (95% CI, 6.42-34.99; I-2=100.0, P<0.001). The Meta regression showed that sensitivity of (18)FDG-PET was higher if the sample size of study was equal or more than 30 cases (sensitivity=0.93; 95% CI: 0.89-0.97), when using PET/CT (sensitivity=0.92; 95% CI: 0.89-0.97), and self-design criteria (sensitivity=0.93; 95% CI: 0.87-1.0). ConclusionThe present meta-analysis showed (18)FDG-PET has a significant value in predicting treatment response in GIST patients.
- Open Access
- 1 March 2016
- Vol. 4 (2) , 55-64
Comparison of Ultrasonography and Radiography in Detection of Thoracic Bone Fractures; a Systematic Review and Meta-Analysis
Introduction: The potential benefit of ultrasonography for detection of thoracic bone fractures has been proven in various surveys but no comprehensive conclusion has been drawn yet; therefore, the present study aimed to conduct a thorough meta-analytic systematic review on this subject. Methods: Two reviewers independently carried out a comprehensive systematic search in Medline, EMBASE, ISI Web of Knowledge, Scopus, Cochrane Library, and ProQuest databases. Data were summarized as true positive, false positive, true negative and false negative and were analyzed via STATA 11.0 software using a mixed-effects binary regression model. Sources of heterogeneity were further assessed through subgroup analysis. Results: Data on 1667 patients (807 subjects with and 860 cases without thoracic fractures), whose age ranged from 0 to 92 years, were extracted from 17 surveys. Pooled sensitivity and specificity of ultrasonography in detection of thoracic bone fractures were 0.97 (95% CI: 0.90-0.99; I2=88.88, p< 0.001) and 0.94 (95% CI: 0.86-0.97; I2=71.97, p< 0.001), respectively. The same measures for chest radiography were found to be 0.77 (95% CI: 0.56-0.90; I2=97.76, p< 0.001) and 1.0 (95% CI: 0.91-1.00; I2=97.24, p< 0.001), respectively. The sensitivity of ultrasonography was higher in detection of rib fractures, compared to fractures of sternum or clavicle (97% vs. 91%). Moreover, the sensitivity was found to be higher when the procedure was carried out by a radiologist in comparison to an emergency medicine specialist (96% vs. 90%). Conclusion: Base on the findings of the present meta-analysis, screening performance characteristic of ultrasonography in detection of thoracic bone fractures was found to be higher than radiography. However, these characteristics were more prominent in detection of rib fractures and in cases where was performed by a radiologist.
- 1 March 2016
- Vol. 4 (2) , 55-64
Open AccessComparison of Ultrasonography and Radiography in Detection of Thoracic Bone Fractures; a Systematic Review and Meta-Analysis
Introduction: The potential benefit of ultrasonography for detection of thoracic bone fractures has been proven in various surveys but no comprehensive conclusion has been drawn yet; therefore, the present study aimed to conduct a thorough meta-analytic systematic review on this subject. Methods: Two reviewers independently carried out a comprehensive systematic search in Medline, EMBASE, ISI Web of Knowledge, Scopus, Cochrane Library, and ProQuest databases. Data were summarized as true positive, false positive, true negative and false negative and were analyzed via STATA 11.0 software using a mixed-effects binary regression model. Sources of heterogeneity were further assessed through subgroup analysis. Results: Data on 1667 patients (807 subjects with and 860 cases without thoracic fractures), whose age ranged from 0 to 92 years, were extracted from 17 surveys. Pooled sensitivity and specificity of ultrasonography in detection of thoracic bone fractures were 0.97 (95% CI: 0.90-0.99; I2=88.88, p< 0.001) and 0.94 (95% CI: 0.86-0.97; I2=71.97, p< 0.001), respectively. The same measures for chest radiography were found to be 0.77 (95% CI: 0.56-0.90; I2=97.76, p< 0.001) and 1.0 (95% CI: 0.91-1.00; I2=97.24, p< 0.001), respectively. The sensitivity of ultrasonography was higher in detection of rib fractures, compared to fractures of sternum or clavicle (97% vs. 91%). Moreover, the sensitivity was found to be higher when the procedure was carried out by a radiologist in comparison to an emergency medicine specialist (96% vs. 90%). Conclusion: Base on the findings of the present meta-analysis, screening performance characteristic of ultrasonography in detection of thoracic bone fractures was found to be higher than radiography. However, these characteristics were more prominent in detection of rib fractures and in cases where was performed by a radiologist.
- Open Access
- 1 September 2015
- Vol. 3 (4) , 127-136
Diagnostic Accuracy of Ultrasonography and Radiography in Detection of Pulmonary Contusion; a Systematic Review and Meta-Analysis
Introduction: Ultrasonography is currently being used as one of the diagnostic modalities in various medical emergencies for screening of trauma patients. The diagnostic value of this modality in detection of traumatic chest injuries has been evaluated by several studies but its diagnostic accuracy in diagnosis of pulmonary contusion is a matter of discussion. Therefore, the present study aimed to determine the diagnostic accuracy of ultrasonography and radiography in detection of pulmonary contusion through a systematic review and meta-analysis. Methods: An extended systematic search was performed by two reviewers in databases of Medline, EMBASE, ISI Web of Knowledge, Scopus, Cochrane Library, and ProQuest. They extracted the data and assessed the quality of the studies. After summarization of data into true positive, false positive, true negative, and false negative meta-analysis was carried out via a mixed-effects binary regression model. Further subgroup analysis was performed due to a significant heterogeneity between the studies. Results: 12 studies were included in this meta-analysis (1681 chest trauma patients, 76% male). Pooled sensitivity of ultrasonography in detection of pulmonary contusion was 0.92 (95% CI: 0.81-0.96; I2= 95.81, p<0.001) and its pooled specificity was calculated to be 0.89 (95% CI: 0.85-0.93; I2 = 67.29, p<0.001) while these figures for chest radiography were 0.44 (95% CI: 0.32-0.58; I2= 87.52, p<0.001) and 0.98 (95% CI: 0.88-1.0; I2= 95.22, p<0.001), respectively. Subgroup analysis showed that the sources of heterogeneity between the studies were sampling method, operator, frequency of the transducer, and sample size. Conclusion: Ultrasonography was found to be a better screening tool in detection of pulmonary contusion. Moreover, an ultrasonography performed by a radiologist / intensivist with 1-5MHz probe has a higher diagnostic value in identifying pulmonary contusions.
- 1 September 2015
- Vol. 3 (4) , 127-136
Open AccessDiagnostic Accuracy of Ultrasonography and Radiography in Detection of Pulmonary Contusion; a Systematic Review and Meta-Analysis
Introduction: Ultrasonography is currently being used as one of the diagnostic modalities in various medical emergencies for screening of trauma patients. The diagnostic value of this modality in detection of traumatic chest injuries has been evaluated by several studies but its diagnostic accuracy in diagnosis of pulmonary contusion is a matter of discussion. Therefore, the present study aimed to determine the diagnostic accuracy of ultrasonography and radiography in detection of pulmonary contusion through a systematic review and meta-analysis. Methods: An extended systematic search was performed by two reviewers in databases of Medline, EMBASE, ISI Web of Knowledge, Scopus, Cochrane Library, and ProQuest. They extracted the data and assessed the quality of the studies. After summarization of data into true positive, false positive, true negative, and false negative meta-analysis was carried out via a mixed-effects binary regression model. Further subgroup analysis was performed due to a significant heterogeneity between the studies. Results: 12 studies were included in this meta-analysis (1681 chest trauma patients, 76% male). Pooled sensitivity of ultrasonography in detection of pulmonary contusion was 0.92 (95% CI: 0.81-0.96; I2= 95.81, p<0.001) and its pooled specificity was calculated to be 0.89 (95% CI: 0.85-0.93; I2 = 67.29, p<0.001) while these figures for chest radiography were 0.44 (95% CI: 0.32-0.58; I2= 87.52, p<0.001) and 0.98 (95% CI: 0.88-1.0; I2= 95.22, p<0.001), respectively. Subgroup analysis showed that the sources of heterogeneity between the studies were sampling method, operator, frequency of the transducer, and sample size. Conclusion: Ultrasonography was found to be a better screening tool in detection of pulmonary contusion. Moreover, an ultrasonography performed by a radiologist / intensivist with 1-5MHz probe has a higher diagnostic value in identifying pulmonary contusions.
- Open Access
- 24 March 2015
- Published by Forschungsgesellschaft für Arbeitsphysiologie und Arbeitsschutz e.V. in EXCLI Journal
- Vol. 14, 465-477
Blood pressure percentiles by age and body mass index for adults
Since no comprehensive study has been conducted on blood pressure (BP) percentiles established upon nationally representative sample population of adults, the present study aimed to construct the blood pressure percentiles by age, sex and body mass index (BMI) of the subjects. Analyses were based on data collected in 2011 from 8,425 adults aged 25 to 69 years old. Data on demographic characteristics, anthropometric measurements, and blood pressure was recorded for each subject. Linear Regression analysis was used to assess the adjusted relationship of age-sex-specific standard deviation scores of BMI, height, and weight with blood pressure. Four separate models for systolic blood pressure (SBP) and diastolic blood pressure (DBP) of men and women were constructed for BP percentiles according to age and BMI. Blood pressure increased with the rise in BMI and weight, but showed a negative correlation with height. SBP and DBP rose steadily with increasing age, but the rise in SBP was greater than DBP. Overweight and obese population, seem to fall into the category of hypertensive. The findings of present study show that BP percentiles are steadily increased by age and BMI. In addition, most obese or overweight adults are hypertensive.
- 24 March 2015
- Published by Forschungsgesellschaft für Arbeitsphysiologie und Arbeitsschutz e.V. in EXCLI Journal
- Vol. 14, 465-477
Open AccessBlood pressure percentiles by age and body mass index for adults
Since no comprehensive study has been conducted on blood pressure (BP) percentiles established upon nationally representative sample population of adults, the present study aimed to construct the blood pressure percentiles by age, sex and body mass index (BMI) of the subjects. Analyses were based on data collected in 2011 from 8,425 adults aged 25 to 69 years old. Data on demographic characteristics, anthropometric measurements, and blood pressure was recorded for each subject. Linear Regression analysis was used to assess the adjusted relationship of age-sex-specific standard deviation scores of BMI, height, and weight with blood pressure. Four separate models for systolic blood pressure (SBP) and diastolic blood pressure (DBP) of men and women were constructed for BP percentiles according to age and BMI. Blood pressure increased with the rise in BMI and weight, but showed a negative correlation with height. SBP and DBP rose steadily with increasing age, but the rise in SBP was greater than DBP. Overweight and obese population, seem to fall into the category of hypertensive. The findings of present study show that BP percentiles are steadily increased by age and BMI. In addition, most obese or overweight adults are hypertensive.