Fan Yu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Fan Yu has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Hongjie Lei
Microsystem Research Center, College of Optoelectronic Engineering, Chongqing University, Chongqing 400044, China
4 shared publications - Quan Wen
Key Laboratory of Fundamental Science of Micro/Nano-Device and System Technology, Chongqing University, Chongqing 400044, China
4 shared publications - Zhiyu Wen
Key Laboratory of Fundamental Science of Micro/Nano-Device and System Technology, Chongqing University, Chongqing 400044, China
4 shared publications - Liangkun Huang
Key Laboratory of Fundamental Science of Micro/Nano-Device and System Technology, Chongqing University, Chongqing 400044, China
3 shared publications - Jian Huang
Key Laboratory of Fundamental Science of Micro/Nano-Device and System Technology, Chongqing University, Chongqing 400044, China
2 shared publications - Dongling Li
Key Laboratory of Optoelectronic Technology and System of the Education Ministry of China, Chongqing University, Chongqing 400030, China
1 shared publication
Latest Publications
- Open Access
- 10 April 2020
- Published by MDPI AG in Micromachines
- Vol. 11 (4) , 393
Miniature Broadband NIR Spectrometer Based on FR4 Electromagnetic Scanning Micro-Grating
This paper presents a miniaturized, broadband near-infrared (NIR) spectrometer with a flame-retardant 4 (FR4)-based scanning micrograte. A 90° off-axis parabolic mirror and a crossed Czerny–Turner structure were used for creating an astigmatism-free optical system design. The optical system of the spectrometer consists of a 90° off-axis parabolic mirror, an FR4-based scanning micrograte, and a two-color indium gallium arsenide (InGaAs) diode with a crossed Czerny–Turner structure optical design. We used a wide exit slit and an off-axis parabolic mirror with a short focal length to improve the signal-to-noise ratio (SNR) of the full spectrum. We enabled a miniaturized design for the spectrometer by utilizing a novel FR4 micrograte for spectral dispersion and spatial scanning. The spectrometer can detect the full near-infrared spectrum while only using a two-color InGaAs diode, and thus, the grating scanning angle of this spectrometer is small when compared to a dual-detector-based spectrometer. In addition, the angle signal can be obtained through an angle sensor, which is integrated into the scanning micrograte. The real-time angle signal is used to form a closed-loop control over the scanning micrograte and calibrate the spectral signal. Finally, a series of tests was performed. The experimental results showed that the spectrometer has a working wavelength range of 800–2500 nm. The resolution is 10 nm at a wavelength range of 800–1650 nm and 15 nm at a wavelength range of 1650–2500 nm. Similarly, the stability of these two wavelength ranges is better than ±1 nm and ±2 nm, respectively. The spectrometer’s volume is 80 × 75 × 65 mm3 and its weight is 0.5 kg. The maximum spectral fluctuation does not exceed 1.5% and the signal-to-noise ratio is 284 after only one instance of averaging.
- 10 April 2020
- Published by MDPI AG in Micromachines
- Vol. 11 (4) , 393
Open AccessMiniature Broadband NIR Spectrometer Based on FR4 Electromagnetic Scanning Micro-Grating
This paper presents a miniaturized, broadband near-infrared (NIR) spectrometer with a flame-retardant 4 (FR4)-based scanning micrograte. A 90° off-axis parabolic mirror and a crossed Czerny–Turner structure were used for creating an astigmatism-free optical system design. The optical system of the spectrometer consists of a 90° off-axis parabolic mirror, an FR4-based scanning micrograte, and a two-color indium gallium arsenide (InGaAs) diode with a crossed Czerny–Turner structure optical design. We used a wide exit slit and an off-axis parabolic mirror with a short focal length to improve the signal-to-noise ratio (SNR) of the full spectrum. We enabled a miniaturized design for the spectrometer by utilizing a novel FR4 micrograte for spectral dispersion and spatial scanning. The spectrometer can detect the full near-infrared spectrum while only using a two-color InGaAs diode, and thus, the grating scanning angle of this spectrometer is small when compared to a dual-detector-based spectrometer. In addition, the angle signal can be obtained through an angle sensor, which is integrated into the scanning micrograte. The real-time angle signal is used to form a closed-loop control over the scanning micrograte and calibrate the spectral signal. Finally, a series of tests was performed. The experimental results showed that the spectrometer has a working wavelength range of 800–2500 nm. The resolution is 10 nm at a wavelength range of 800–1650 nm and 15 nm at a wavelength range of 1650–2500 nm. Similarly, the stability of these two wavelength ranges is better than ±1 nm and ±2 nm, respectively. The spectrometer’s volume is 80 × 75 × 65 mm3 and its weight is 0.5 kg. The maximum spectral fluctuation does not exceed 1.5% and the signal-to-noise ratio is 284 after only one instance of averaging.
- Open Access
- 10 July 2019
- Published by MDPI AG in Electronics
- Vol. 8 (7) , 770
A Compound Control System for FR4-Based Electromagnetic Scanning Micrograting
This paper presents a compound control system for precise control of the flame-retardant 4 (FR4)-based electromagnetic scanning micrograting. It mainly consists of a frequency controller and an angle controller. A dual closed-loop structure consisting of a current loop and an angle loop was designed in the angle controller. In addition, the incremental proportional–integral–derivative (PID) control algorithm was designed in the current loop, and the fuzzy-PID control algorithm was employed in the angle loop. From the experimental results, the frequency controller can effectively track the real-time resonant frequency of the scanning micrograting with a tracking accuracy of 0.1 Hz. The overshoot of the scanning micrograting is eliminated. Compared to an open-loop control system, the control system presented in this work reduces the steady-state error of the scanning micrograting from 1.122% to 0.243%. The control accuracy of the compound control system is 0.02°. The anti-interference recovery time of the scanning micrograting was reduced from 550 ms to 181 ms, and the long-term stability was increased from 2.94% to 0.12%. In the compound control system presented in this paper, the crucial parameters of the FR4-based electromagnetic scanning micrograting, including motion accuracy, anti-interference ability, and long-term stability, were effectively improved.
- 10 July 2019
- Published by MDPI AG in Electronics
- Vol. 8 (7) , 770
Open AccessA Compound Control System for FR4-Based Electromagnetic Scanning Micrograting
This paper presents a compound control system for precise control of the flame-retardant 4 (FR4)-based electromagnetic scanning micrograting. It mainly consists of a frequency controller and an angle controller. A dual closed-loop structure consisting of a current loop and an angle loop was designed in the angle controller. In addition, the incremental proportional–integral–derivative (PID) control algorithm was designed in the current loop, and the fuzzy-PID control algorithm was employed in the angle loop. From the experimental results, the frequency controller can effectively track the real-time resonant frequency of the scanning micrograting with a tracking accuracy of 0.1 Hz. The overshoot of the scanning micrograting is eliminated. Compared to an open-loop control system, the control system presented in this work reduces the steady-state error of the scanning micrograting from 1.122% to 0.243%. The control accuracy of the compound control system is 0.02°. The anti-interference recovery time of the scanning micrograting was reduced from 550 ms to 181 ms, and the long-term stability was increased from 2.94% to 0.12%. In the compound control system presented in this paper, the crucial parameters of the FR4-based electromagnetic scanning micrograting, including motion accuracy, anti-interference ability, and long-term stability, were effectively improved.
- Open Access
- 28 November 2018
- Published by MDPI AG in Applied Sciences
- Vol. 8 (12) , 2412
Investigation of Electromagnetic Angle Sensor Integrated in FR4-Based Scanning Micromirror
This paper performs a detailed investigation on the electromagnetic angle sensor integrated in the flame retardant 4 (FR4)-based scanning micromirror. An accurate theoretical model is presented, especially considering the coupling effect between the driving and sensing coils. Experimental results agree well with the theoretical results, and show a sensitivity of 55.0 mVp/° and a high signal-to-noise ratio (SNR) of 71.9 dB. Moreover, the linearity of the angle sensor can still reach 0.9995, though it is affected slightly by the coupling effect. Finally, the sensor’s good feasibility for feedback control has been further verified through a simple closed-loop control circuit. The micromirror operated with closed-loop control possesses better long-term stability and temperature stability than that operated without closed-loop control.
- 28 November 2018
- Published by MDPI AG in Applied Sciences
- Vol. 8 (12) , 2412
Open AccessInvestigation of Electromagnetic Angle Sensor Integrated in FR4-Based Scanning Micromirror
This paper performs a detailed investigation on the electromagnetic angle sensor integrated in the flame retardant 4 (FR4)-based scanning micromirror. An accurate theoretical model is presented, especially considering the coupling effect between the driving and sensing coils. Experimental results agree well with the theoretical results, and show a sensitivity of 55.0 mVp/° and a high signal-to-noise ratio (SNR) of 71.9 dB. Moreover, the linearity of the angle sensor can still reach 0.9995, though it is affected slightly by the coupling effect. Finally, the sensor’s good feasibility for feedback control has been further verified through a simple closed-loop control circuit. The micromirror operated with closed-loop control possesses better long-term stability and temperature stability than that operated without closed-loop control.
- Open Access
- 2 May 2018
- Published by MDPI AG in Micromachines
- Vol. 9 (5) , 214
FR4-Based Electromagnetic Scanning Micromirror Integrated with Angle Sensor
This paper presents a flame retardant 4 (FR4)-based electromagnetic scanning micromirror, which aims to overcome the limitations of conventional microelectromechanical systems (MEMS) micromirrors for the large-aperture and low-frequency scanning applications. This micromirror is fabricated through a commercial printed circuit board (PCB) technology at a low cost and with a short process cycle, before an aluminum-coated silicon mirror plate with a large aperture is bonded on the FR4 platform to provide a high surface quality. In particular, an electromagnetic angle sensor is integrated to monitor the motion of the micromirror in real time. A prototype has been assembled and tested. The results show that the micromirror can reach the optical scan angle of 11.2 with a low driving voltage of only 425 mV at resonance (361.8 Hz). At the same time, the signal of the integrated angle sensor also shows good signal-to-noise ratio, linearity and sensitivity. Finally, the reliability of the FR4 based micro-mirror has been tested. The prototype successfully passes both shock and vibration tests. Furthermore, the results of the long-term mechanical cycling test (50 million cycles) suggest that the maximum variations of resonant frequency and scan angle are less than 0.3% and 6%, respectively. Therefore, this simple and robust micromirror has great potential in being useful in a number of optical microsystems, especially when large-aperture or low-frequency is required.- 2 May 2018
- Published by MDPI AG in Micromachines
- Vol. 9 (5) , 214
Open AccessFR4-Based Electromagnetic Scanning Micromirror Integrated with Angle Sensor
This paper presents a flame retardant 4 (FR4)-based electromagnetic scanning micromirror, which aims to overcome the limitations of conventional microelectromechanical systems (MEMS) micromirrors for the large-aperture and low-frequency scanning applications. This micromirror is fabricated through a commercial printed circuit board (PCB) technology at a low cost and with a short process cycle, before an aluminum-coated silicon mirror plate with a large aperture is bonded on the FR4 platform to provide a high surface quality. In particular, an electromagnetic angle sensor is integrated to monitor the motion of the micromirror in real time. A prototype has been assembled and tested. The results show that the micromirror can reach the optical scan angle of 11.2 with a low driving voltage of only 425 mV at resonance (361.8 Hz). At the same time, the signal of the integrated angle sensor also shows good signal-to-noise ratio, linearity and sensitivity. Finally, the reliability of the FR4 based micro-mirror has been tested. The prototype successfully passes both shock and vibration tests. Furthermore, the results of the long-term mechanical cycling test (50 million cycles) suggest that the maximum variations of resonant frequency and scan angle are less than 0.3% and 6%, respectively. Therefore, this simple and robust micromirror has great potential in being useful in a number of optical microsystems, especially when large-aperture or low-frequency is required.