CRChristopher Rogers

Christopher Rogers

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Christopher Rogers has a total of 20 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Coherent feedback control of two-dimensional excitons

    by Christopher Rogers, Dodd Gray, Nathan Bogdanowicz, Takashi Taniguchi, Kenji Watanabe, Hideo Mabuchi

    Electric dipole radiation can be controlled by engineering of the photonic environment. A coherent interaction between forward and backward emission depends interferometrically on the position of a nearby mirror. The transverse coherence of exciton emission in a single layer of MoSe2 and the highly radiatively broadened nature of our samples removes fundamental physical limitations of previous experiments employing pointlike dipoles. This enables full control over the exciton radiative coupling rate and total linewidth at cryogenic temperatures from near zero to 1.8±0.4meV and from 0.9 to 2.3±0.1meV, respectively.


  • Open Access

    Coherent Control of Two-Dimensional Excitons

    by Christopher Rogers, Dodd Gray Jr., Nathan Bogdanowicz, Takashi Taniguchi, Kenji Watanabe, Hideo Mabuchi

    Electric dipole radiation can be controlled by coherent optical feedback, as has previously been studied by modulating the photonic environment for point dipoles placed both in optical cavities and near metal mirrors. In experiments involving fluorescent molecules, trapped ions and quantum dots the point nature of the dipole, its sub-unity quantum efficiency, and decoherence rate conspire to severely limit any change in total linewidth. Here we show that the transverse coherence of exciton emission in the monolayer two-dimensional (2D) material MoSe${}_2$ removes many of the fundamental physical limitations present in previous experiments. The coherent interaction between excitons and a photonic mode localized between the MoSe${}_2$ and a nearby planar mirror depends interferometrically on mirror position, enabling full control over the radiative coupling rate from near-zero to 1.8 meV and a corresponding change in exciton total linewidth from 0.9 to 2.3 meV. The highly radiatively broadened exciton resonance (a ratio of up to $3:1$ in our samples) necessary to observe this modulation is made possible by recent advances in 2D materials sample fabrication. Our method of mirror translation is free of any coupling to strain or DC electric field in the monolayer, which allows a fundamental study of this photonic effect. The weak coherent driving field in our experiments yields a mean excitation occupation number of ${\sim} 10^{-3}$ such that our experiments correspond to probing radiative reaction in the regime of perturbative quantum electrodynamics. This system will serve as a testbed for exploring new excitonic physics and quantum nonlinear optical effects.

  • Open Access

    Laser annealing for radiatively broadened MoSe2 grown by chemical vapor deposition

    by Christopher Rogers, Dodd Gray, Nate Bogdanowicz, Hideo Mabuchi

    We report on a laser annealing procedure which greatly improves the quality of suspended monolayers of chemical vapor deposition grown MoSe2. Annealing with a green laser locally heats the suspended flake to approximately 600 K, which both removes contaminants and reduces strain gradients. At 4 K, we observe linewidths as narrow as 3.5 meV (1.6 nm) full width at half maximum for both photoluminescence and reflection. Large peak reflectances up to 47% are also observed. These values are comparable to those of the highest quality hexagonal boron nitride encapsulated samples. We demonstrate that this laser annealing process can yield highly spatially homogeneous samples, with the length scale of the homogeneity limited primarily by the size of the suspended area. Annealed regions are very stable, exhibiting negligible deterioration over 24 h at cryogenic temperatures. The annealing method is also very repeatable, with substantial improvements of sample quality on every spot (>40) tested.


  • Conditions for Parametric and Free-Carrier Oscillation in Silicon Ring Cavities

    by Ryan Hamerly, Dodd Gray, Christopher Rogers, Kambiz Jamshidi

    We model optical parametric oscillation in ring cavities with two-photon absorption, focusing on silicon at 1.55μm. Oscillation is possible if free-carrier absorption can be mitigated; this can be achieved using carrier sweep-out in a reverse-biased p-i-n junction to reduce the carrier lifetime. By varying the pump power, detuning, and reverse-bias voltage, it is possible to generate frequency combs in cavities with both normal and anomalous dispersion at a wide range of wavelengths including 1.55μm. Furthermore, a free-carrier self-pulsing instability leads to rich dynamics when the carrier lifetime is sufficiently long.


  • Open Access

    Laser Annealing for Radiatively Broadened MoSe2 grown by Chemical Vapor Deposition

    by Christopher Rogers, Dodd Gray, Nate Bogdanowicz, Hideo Mabuchi

    We report on a laser annealing procedure which greatly improves the quality of suspended monolayers of chemical vapor deposition (CVD) grown MoSe2. Annealing with a green laser locally heats the suspended flake to approximately 600 K, which both removes contaminants and reduces strain gradients. At 4 K, we observe linewidths as narrow as 3.5 meV (1.6nm) full-width at half-max (FWHM) for both photoluminescence (PL) and reflection. Large peak reflectances up to 47% are also observed. These values are comparable to those of the highest quality hexagonal boron nitride (hBN) encapsulated samples. We demonstrate that this laser annealing process can yield highly spatially homogeneous samples, with the length scale of the homogeneity limited primarily by the size of the suspended area. Annealed regions are very stable, exhibiting negligible deterioration over 24 hours at cryogenic temperatures. The annealing method is also very repeatable, with substantial improvements of sample quality on every spot (> 40) tested.

  • Open Access

    Optical nonlinearities of excitons in monolayer MoS2

    by Daniel B. S. Soh, Christopher Rogers, Dodd J. Gray, Eric Chatterjee, Hideo Mabuchi

    We calculate linear and nonlinear optical susceptibilities arising from the excitonic states of monolayer MoS2 for in-plane light polarizations, using second-quantized bound and unbound exciton operators. Optical selection rules are critical for obtaining the susceptibilities. We derive the valley-chirality rule for the second-order harmonic generation in monolayer MoS2 and find that the third-order harmonic process is efficient only for linearly polarized input light while the third-order two-photon process (optical Kerr effect) is efficient for circularly polarized light using a higher order exciton state. The absence of linear absorption due to the band gap and the unusually strong two-photon third-order nonlinearity make the monolayer MoS2 excitonic structure a promising resource for coherent nonlinear photonics.


  • Open Access

    Conditions for Parametric and Free-Carrier Oscillation in Silicon Ring Cavities

    by Ryan Hamerly, Dodd Gray, Christopher Rogers, Kambiz Jamshidi

    We model optical parametric oscillation in ring cavities with two-photon absorption, focusing on silicon at 1.55$\mu$m. Oscillation is possible if free-carrier absorption can be mitigated; this can be achieved using carrier sweep-out in a reverse-biased p-i-n junction to reduce the carrier lifetime. By varying the pump power, detuning, and reverse-bias voltage, it is possible to generate frequency combs in cavities with both normal and anomalous dispersion at a wide range of wavelengths including 1.55$\mu$m. Furthermore, a free-carrier self-pulsing instability leads to rich dynamics when the carrier lifetime is sufficiently long.

  • Feasibility study of optical parametric amplification using CMOS compatible ring resonators

    by Mahmoud Jazayerifar, Meysam Namdari, Ryan Hamerly, Dodd Gray, Christopher Rogers, Kambiz Jamshidi

  • Paradoxical response to photorefractive treatment for postkeratoplasty astigmatism

    by Graham Fraenkel, Gerard Sutton, Christopher Rogers, Michael Lawless

    A 42-year-old woman with functionally disabling postkeratoplasty astigmatism in her right eye 3 years after corneal transplantation for keratoconus received photorefractive keratectomy for high astigmatism in that eye. This did not reduce her astigmatism. The procedure was repeated and corneal astigmatism paradoxically increased. The forces within the pseudo-optical ring that cause and maintain astigmatism in corneal transplants may be a significant factor in the unpredictable response of some corneal transplants to excimer photorefractive astigmatism correction.


  • Treatment of myopic astigmatism with the Summit Apex Plus excimer laser

    by Jean-Pierre Danjoux, Graham Fraenkel, Michael A. Lawless, Christopher Rogers

    To assess the results of surface sequential toric photorefractive keratectomy (PRK) with the Summit Apex Plus excimer laser using an erodible mask. A prospective study was performed on consecutive eyes having surface sequential toric PRK over a 4 month treatment period. Attempted astigmatism correction varied from 70 to 100%, depending on the power and axis of the cylinder. The myopic correction was adjusted so the combined treatment aim was emmetropia. Refraction, manual keratometry, corneal haze, and visual acuity data from preoperative and follow-up visits over 12 months were divided into various groups based on the preoperative refraction and analyzed. Fifty-nine eyes from 48 patients had sequential toric PRK. Preoperatively, the mean spherical equivalent at glasses plane (SEGP) was -4.88 diopters (D) +/- 3.20 (SD) and the mean refractive cylinder, 2.02 +/- 1.04 D. The mean attempted cylinder correction was 1.87 D. At 12 months the mean SEGP was -0.02 +/- 0.67 D, which was not statistically significant from plano. The mean refractive cylinder was 0.84 +/- 0.84 D, which was statistically significantly different from zero cylinder power. There was a statistically significant correlation between the preoperative and the 12 month postoperative refractive cylinder powers. At 12 months, 34 of 43 eyes (79.1%) had an uncorrected visual acuity of 6/12 or better. While 2 eyes in one patient (4.7%) lost two lines of best corrected visual acuity, with a final acuity of 6/12 in each, no patient lost more than two lines. The manifest refraction cylinder power is not fully corrected with the current treatment algorithms; however, surface sequential toric PRK using an erodible mask is capable of treating compound myopic astigmatism with moderate success.