Christopher Rogers
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Christopher Rogers has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Dodd Gray
Stanford Univ. (United States)
5 shared publications - Hideo Mabuchi
Ginzton Laboratory, Stanford University, 348 Via Pueblo, Stanford, California 94305, USA
4 shared publications - Ryan Hamerly
Research Laboratory of Electronics, MIT, Cambridge, USA
3 shared publications Dodd Gray
Ginzton Laboratory Stanford University 348 Via Pueblo 94305 Stanford California USA
2 shared publicationsGraham Fraenkel
Sydney Refractive Surgery Center, Chatswood, Australia
2 shared publications- Kambiz Jamshidi
Integrated Photonic Devices Group, Chair of RF and Photonics, Faculty of Electrical and Computer Engineering, Technische Universitat Dresden, Dresden, Germany
2 shared publications
Latest Publications
- Open Access
- 31 January 2020
- Published by American Physical Society (APS) in Physical Review Research
- Vol. 2 (1) , 012029
Coherent feedback control of two-dimensional excitons
Electric dipole radiation can be controlled by engineering of the photonic environment. A coherent interaction between forward and backward emission depends interferometrically on the position of a nearby mirror. The transverse coherence of exciton emission in a single layer of and the highly radiatively broadened nature of our samples removes fundamental physical limitations of previous experiments employing pointlike dipoles. This enables full control over the exciton radiative coupling rate and total linewidth at cryogenic temperatures from near zero to and from 0.9 to , respectively.- 31 January 2020
- Published by American Physical Society (APS) in Physical Review Research
- Vol. 2 (1) , 012029
Open AccessCoherent feedback control of two-dimensional excitons
Electric dipole radiation can be controlled by engineering of the photonic environment. A coherent interaction between forward and backward emission depends interferometrically on the position of a nearby mirror. The transverse coherence of exciton emission in a single layer of and the highly radiatively broadened nature of our samples removes fundamental physical limitations of previous experiments employing pointlike dipoles. This enables full control over the exciton radiative coupling rate and total linewidth at cryogenic temperatures from near zero to and from 0.9 to , respectively. - Open Access
Coherent Control of Two-Dimensional Excitons
Electric dipole radiation can be controlled by coherent optical feedback, as has previously been studied by modulating the photonic environment for point dipoles placed both in optical cavities and near metal mirrors. In experiments involving fluorescent molecules, trapped ions and quantum dots the point nature of the dipole, its sub-unity quantum efficiency, and decoherence rate conspire to severely limit any change in total linewidth. Here we show that the transverse coherence of exciton emission in the monolayer two-dimensional (2D) material MoSe${}_2$ removes many of the fundamental physical limitations present in previous experiments. The coherent interaction between excitons and a photonic mode localized between the MoSe${}_2$ and a nearby planar mirror depends interferometrically on mirror position, enabling full control over the radiative coupling rate from near-zero to 1.8 meV and a corresponding change in exciton total linewidth from 0.9 to 2.3 meV. The highly radiatively broadened exciton resonance (a ratio of up to $3:1$ in our samples) necessary to observe this modulation is made possible by recent advances in 2D materials sample fabrication. Our method of mirror translation is free of any coupling to strain or DC electric field in the monolayer, which allows a fundamental study of this photonic effect. The weak coherent driving field in our experiments yields a mean excitation occupation number of ${\sim} 10^{-3}$ such that our experiments correspond to probing radiative reaction in the regime of perturbative quantum electrodynamics. This system will serve as a testbed for exploring new excitonic physics and quantum nonlinear optical effects.Open AccessCoherent Control of Two-Dimensional Excitons
Electric dipole radiation can be controlled by coherent optical feedback, as has previously been studied by modulating the photonic environment for point dipoles placed both in optical cavities and near metal mirrors. In experiments involving fluorescent molecules, trapped ions and quantum dots the point nature of the dipole, its sub-unity quantum efficiency, and decoherence rate conspire to severely limit any change in total linewidth. Here we show that the transverse coherence of exciton emission in the monolayer two-dimensional (2D) material MoSe${}_2$ removes many of the fundamental physical limitations present in previous experiments. The coherent interaction between excitons and a photonic mode localized between the MoSe${}_2$ and a nearby planar mirror depends interferometrically on mirror position, enabling full control over the radiative coupling rate from near-zero to 1.8 meV and a corresponding change in exciton total linewidth from 0.9 to 2.3 meV. The highly radiatively broadened exciton resonance (a ratio of up to $3:1$ in our samples) necessary to observe this modulation is made possible by recent advances in 2D materials sample fabrication. Our method of mirror translation is free of any coupling to strain or DC electric field in the monolayer, which allows a fundamental study of this photonic effect. The weak coherent driving field in our experiments yields a mean excitation occupation number of ${\sim} 10^{-3}$ such that our experiments correspond to probing radiative reaction in the regime of perturbative quantum electrodynamics. This system will serve as a testbed for exploring new excitonic physics and quantum nonlinear optical effects. - Open Access
- 17 September 2018
- Published by American Physical Society (APS) in Physical Review Materials
- Vol. 2 (9) , 094003
Laser annealing for radiatively broadened grown by chemical vapor depositionWe report on a laser annealing procedure which greatly improves the quality of suspended monolayers of chemical vapor deposition grown . Annealing with a green laser locally heats the suspended flake to approximately 600 K, which both removes contaminants and reduces strain gradients. At 4 K, we observe linewidths as narrow as 3.5 meV (1.6 nm) full width at half maximum for both photoluminescence and reflection. Large peak reflectances up to 47% are also observed. These values are comparable to those of the highest quality hexagonal boron nitride encapsulated samples. We demonstrate that this laser annealing process can yield highly spatially homogeneous samples, with the length scale of the homogeneity limited primarily by the size of the suspended area. Annealed regions are very stable, exhibiting negligible deterioration over 24 h at cryogenic temperatures. The annealing method is also very repeatable, with substantial improvements of sample quality on every spot () tested.- 17 September 2018
- Published by American Physical Society (APS) in Physical Review Materials
- Vol. 2 (9) , 094003
Open AccessLaser annealing for radiatively broadened grown by chemical vapor depositionWe report on a laser annealing procedure which greatly improves the quality of suspended monolayers of chemical vapor deposition grown . Annealing with a green laser locally heats the suspended flake to approximately 600 K, which both removes contaminants and reduces strain gradients. At 4 K, we observe linewidths as narrow as 3.5 meV (1.6 nm) full width at half maximum for both photoluminescence and reflection. Large peak reflectances up to 47% are also observed. These values are comparable to those of the highest quality hexagonal boron nitride encapsulated samples. We demonstrate that this laser annealing process can yield highly spatially homogeneous samples, with the length scale of the homogeneity limited primarily by the size of the suspended area. Annealed regions are very stable, exhibiting negligible deterioration over 24 h at cryogenic temperatures. The annealing method is also very repeatable, with substantial improvements of sample quality on every spot () tested. - 3 May 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Lightwave Technology
- Vol. 36 (19) , 4671-4677
Conditions for Parametric and Free-Carrier Oscillation in Silicon Ring Cavities
We model optical parametric oscillation in ring cavities with two-photon absorption, focusing on silicon at 1.55μm. Oscillation is possible if free-carrier absorption can be mitigated; this can be achieved using carrier sweep-out in a reverse-biased p-i-n junction to reduce the carrier lifetime. By varying the pump power, detuning, and reverse-bias voltage, it is possible to generate frequency combs in cavities with both normal and anomalous dispersion at a wide range of wavelengths including 1.55μm. Furthermore, a free-carrier self-pulsing instability leads to rich dynamics when the carrier lifetime is sufficiently long.
- 3 May 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Lightwave Technology
- Vol. 36 (19) , 4671-4677
Conditions for Parametric and Free-Carrier Oscillation in Silicon Ring Cavities
We model optical parametric oscillation in ring cavities with two-photon absorption, focusing on silicon at 1.55μm. Oscillation is possible if free-carrier absorption can be mitigated; this can be achieved using carrier sweep-out in a reverse-biased p-i-n junction to reduce the carrier lifetime. By varying the pump power, detuning, and reverse-bias voltage, it is possible to generate frequency combs in cavities with both normal and anomalous dispersion at a wide range of wavelengths including 1.55μm. Furthermore, a free-carrier self-pulsing instability leads to rich dynamics when the carrier lifetime is sufficiently long.
- Open Access
Laser Annealing for Radiatively Broadened MoSe2 grown by Chemical Vapor Deposition
We report on a laser annealing procedure which greatly improves the quality of suspended monolayers of chemical vapor deposition (CVD) grown MoSe2. Annealing with a green laser locally heats the suspended flake to approximately 600 K, which both removes contaminants and reduces strain gradients. At 4 K, we observe linewidths as narrow as 3.5 meV (1.6nm) full-width at half-max (FWHM) for both photoluminescence (PL) and reflection. Large peak reflectances up to 47% are also observed. These values are comparable to those of the highest quality hexagonal boron nitride (hBN) encapsulated samples. We demonstrate that this laser annealing process can yield highly spatially homogeneous samples, with the length scale of the homogeneity limited primarily by the size of the suspended area. Annealed regions are very stable, exhibiting negligible deterioration over 24 hours at cryogenic temperatures. The annealing method is also very repeatable, with substantial improvements of sample quality on every spot (> 40) tested.
Open AccessLaser Annealing for Radiatively Broadened MoSe2 grown by Chemical Vapor Deposition
We report on a laser annealing procedure which greatly improves the quality of suspended monolayers of chemical vapor deposition (CVD) grown MoSe2. Annealing with a green laser locally heats the suspended flake to approximately 600 K, which both removes contaminants and reduces strain gradients. At 4 K, we observe linewidths as narrow as 3.5 meV (1.6nm) full-width at half-max (FWHM) for both photoluminescence (PL) and reflection. Large peak reflectances up to 47% are also observed. These values are comparable to those of the highest quality hexagonal boron nitride (hBN) encapsulated samples. We demonstrate that this laser annealing process can yield highly spatially homogeneous samples, with the length scale of the homogeneity limited primarily by the size of the suspended area. Annealed regions are very stable, exhibiting negligible deterioration over 24 hours at cryogenic temperatures. The annealing method is also very repeatable, with substantial improvements of sample quality on every spot (> 40) tested.
- Open Access
- 6 April 2018
- Published by American Physical Society (APS) in Physical Review B
- Vol. 97 (16) , 165111
Optical nonlinearities of excitons in monolayerWe calculate linear and nonlinear optical susceptibilities arising from the excitonic states of monolayer for in-plane light polarizations, using second-quantized bound and unbound exciton operators. Optical selection rules are critical for obtaining the susceptibilities. We derive the valley-chirality rule for the second-order harmonic generation in monolayer and find that the third-order harmonic process is efficient only for linearly polarized input light while the third-order two-photon process (optical Kerr effect) is efficient for circularly polarized light using a higher order exciton state. The absence of linear absorption due to the band gap and the unusually strong two-photon third-order nonlinearity make the monolayer excitonic structure a promising resource for coherent nonlinear photonics.- 6 April 2018
- Published by American Physical Society (APS) in Physical Review B
- Vol. 97 (16) , 165111
Open AccessOptical nonlinearities of excitons in monolayerWe calculate linear and nonlinear optical susceptibilities arising from the excitonic states of monolayer for in-plane light polarizations, using second-quantized bound and unbound exciton operators. Optical selection rules are critical for obtaining the susceptibilities. We derive the valley-chirality rule for the second-order harmonic generation in monolayer and find that the third-order harmonic process is efficient only for linearly polarized input light while the third-order two-photon process (optical Kerr effect) is efficient for circularly polarized light using a higher order exciton state. The absence of linear absorption due to the band gap and the unusually strong two-photon third-order nonlinearity make the monolayer excitonic structure a promising resource for coherent nonlinear photonics. - Open Access
Conditions for Parametric and Free-Carrier Oscillation in Silicon Ring Cavities
We model optical parametric oscillation in ring cavities with two-photon absorption, focusing on silicon at 1.55$\mu$m. Oscillation is possible if free-carrier absorption can be mitigated; this can be achieved using carrier sweep-out in a reverse-biased p-i-n junction to reduce the carrier lifetime. By varying the pump power, detuning, and reverse-bias voltage, it is possible to generate frequency combs in cavities with both normal and anomalous dispersion at a wide range of wavelengths including 1.55$\mu$m. Furthermore, a free-carrier self-pulsing instability leads to rich dynamics when the carrier lifetime is sufficiently long.
Open AccessConditions for Parametric and Free-Carrier Oscillation in Silicon Ring Cavities
We model optical parametric oscillation in ring cavities with two-photon absorption, focusing on silicon at 1.55$\mu$m. Oscillation is possible if free-carrier absorption can be mitigated; this can be achieved using carrier sweep-out in a reverse-biased p-i-n junction to reduce the carrier lifetime. By varying the pump power, detuning, and reverse-bias voltage, it is possible to generate frequency combs in cavities with both normal and anomalous dispersion at a wide range of wavelengths including 1.55$\mu$m. Furthermore, a free-carrier self-pulsing instability leads to rich dynamics when the carrier lifetime is sufficiently long.
- 16 February 2017
- Published by SPIE-Intl Soc Optical Eng
- p. 101060A-101060A-9
Feasibility study of optical parametric amplification using CMOS compatible ring resonators
- 16 February 2017
- Published by SPIE-Intl Soc Optical Eng
- p. 101060A-101060A-9
Feasibility study of optical parametric amplification using CMOS compatible ring resonators
- 1 June 1998
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 24 (6) , 861-865
Paradoxical response to photorefractive treatment for postkeratoplasty astigmatism
A 42-year-old woman with functionally disabling postkeratoplasty astigmatism in her right eye 3 years after corneal transplantation for keratoconus received photorefractive keratectomy for high astigmatism in that eye. This did not reduce her astigmatism. The procedure was repeated and corneal astigmatism paradoxically increased. The forces within the pseudo-optical ring that cause and maintain astigmatism in corneal transplants may be a significant factor in the unpredictable response of some corneal transplants to excimer photorefractive astigmatism correction.
- 1 June 1998
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 24 (6) , 861-865
Paradoxical response to photorefractive treatment for postkeratoplasty astigmatism
A 42-year-old woman with functionally disabling postkeratoplasty astigmatism in her right eye 3 years after corneal transplantation for keratoconus received photorefractive keratectomy for high astigmatism in that eye. This did not reduce her astigmatism. The procedure was repeated and corneal astigmatism paradoxically increased. The forces within the pseudo-optical ring that cause and maintain astigmatism in corneal transplants may be a significant factor in the unpredictable response of some corneal transplants to excimer photorefractive astigmatism correction.
- 1 December 1997
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 23 (10) , 1472-1479
Treatment of myopic astigmatism with the Summit Apex Plus excimer laser
To assess the results of surface sequential toric photorefractive keratectomy (PRK) with the Summit Apex Plus excimer laser using an erodible mask. A prospective study was performed on consecutive eyes having surface sequential toric PRK over a 4 month treatment period. Attempted astigmatism correction varied from 70 to 100%, depending on the power and axis of the cylinder. The myopic correction was adjusted so the combined treatment aim was emmetropia. Refraction, manual keratometry, corneal haze, and visual acuity data from preoperative and follow-up visits over 12 months were divided into various groups based on the preoperative refraction and analyzed. Fifty-nine eyes from 48 patients had sequential toric PRK. Preoperatively, the mean spherical equivalent at glasses plane (SEGP) was -4.88 diopters (D) +/- 3.20 (SD) and the mean refractive cylinder, 2.02 +/- 1.04 D. The mean attempted cylinder correction was 1.87 D. At 12 months the mean SEGP was -0.02 +/- 0.67 D, which was not statistically significant from plano. The mean refractive cylinder was 0.84 +/- 0.84 D, which was statistically significantly different from zero cylinder power. There was a statistically significant correlation between the preoperative and the 12 month postoperative refractive cylinder powers. At 12 months, 34 of 43 eyes (79.1%) had an uncorrected visual acuity of 6/12 or better. While 2 eyes in one patient (4.7%) lost two lines of best corrected visual acuity, with a final acuity of 6/12 in each, no patient lost more than two lines. The manifest refraction cylinder power is not fully corrected with the current treatment algorithms; however, surface sequential toric PRK using an erodible mask is capable of treating compound myopic astigmatism with moderate success.
- 1 December 1997
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 23 (10) , 1472-1479
Treatment of myopic astigmatism with the Summit Apex Plus excimer laser
To assess the results of surface sequential toric photorefractive keratectomy (PRK) with the Summit Apex Plus excimer laser using an erodible mask. A prospective study was performed on consecutive eyes having surface sequential toric PRK over a 4 month treatment period. Attempted astigmatism correction varied from 70 to 100%, depending on the power and axis of the cylinder. The myopic correction was adjusted so the combined treatment aim was emmetropia. Refraction, manual keratometry, corneal haze, and visual acuity data from preoperative and follow-up visits over 12 months were divided into various groups based on the preoperative refraction and analyzed. Fifty-nine eyes from 48 patients had sequential toric PRK. Preoperatively, the mean spherical equivalent at glasses plane (SEGP) was -4.88 diopters (D) +/- 3.20 (SD) and the mean refractive cylinder, 2.02 +/- 1.04 D. The mean attempted cylinder correction was 1.87 D. At 12 months the mean SEGP was -0.02 +/- 0.67 D, which was not statistically significant from plano. The mean refractive cylinder was 0.84 +/- 0.84 D, which was statistically significantly different from zero cylinder power. There was a statistically significant correlation between the preoperative and the 12 month postoperative refractive cylinder powers. At 12 months, 34 of 43 eyes (79.1%) had an uncorrected visual acuity of 6/12 or better. While 2 eyes in one patient (4.7%) lost two lines of best corrected visual acuity, with a final acuity of 6/12 in each, no patient lost more than two lines. The manifest refraction cylinder power is not fully corrected with the current treatment algorithms; however, surface sequential toric PRK using an erodible mask is capable of treating compound myopic astigmatism with moderate success.