Martin Pfeifer
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Martin Pfeifer has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Sören Hohmann
Institute of Control Systems (IRS), Karlsruhe Institute of Technology (KIT), Karlsruhe, Germany
7 shared publications - Charles Muller
Institute of Control Systems (IRS), Karlsruhe Institute of Technology (KIT), Kaiserstr. 12, 76131 Karlsruhe, Germany
2 shared publications - Christoph Michael Hackl
Laboratory for Mechatronic and Renewable Energy Systems (LMRES), Hochschule Mnchen (HM) University of Applied Sciences, Munich, Germany
2 shared publications - Lukas Kölsch
Department of Electrical Engineering and Information Technology, Karlsruhe Institute of Technology, Karlsruhe, Germany
2 shared publications - Silja Pfeiffer
Institute of Control Systems (IRS), Karlsruhe Institute of Technology (KIT), Kaiserstr. 12, 76131 Karlsruhe, Germany
2 shared publications - Stefan Krebs
Institute of Control Systems (IRS), Karlsruhe Institute of Technology (KIT), Kaiserstr. 12, 76131 Karlsruhe, Germany
2 shared publications
Latest Publications
- 15 June 2022
- Published by Elsevier in European Journal of Control
- Vol. 68
Distributed coordination of physically-interconnected multi-agent systems with actuated and unactuated agents
- 15 June 2022
- Published by Elsevier in European Journal of Control
- Vol. 68
Distributed coordination of physically-interconnected multi-agent systems with actuated and unactuated agents
- 25 March 2022
- Published by Walter de Gruyter GmbH in at - Automatisierungstechnik
- Vol. 70 (4) , 400-401
Automatisierte Erzeugung von Modellen und Beobachtern für physikalisch vernetzte Systeme
Zusammenfassung Diese Arbeit befasst sich mit der Automatisierung der physikorientierten Modellbildung und des darauf basierenden Beobachterentwurfs. Hierzu werden Port-Hamiltonsche Methoden entwickelt, die erstmals eine durchgängige Automatisierung der Modellbildung und des Beobachterentwurfs für eine große Klasse physikalisch vernetzter Systeme ermöglichen.
- 25 March 2022
- Published by Walter de Gruyter GmbH in at - Automatisierungstechnik
- Vol. 70 (4) , 400-401
Automatisierte Erzeugung von Modellen und Beobachtern für physikalisch vernetzte Systeme
Zusammenfassung Diese Arbeit befasst sich mit der Automatisierung der physikorientierten Modellbildung und des darauf basierenden Beobachterentwurfs. Hierzu werden Port-Hamiltonsche Methoden entwickelt, die erstmals eine durchgängige Automatisierung der Modellbildung und des Beobachterentwurfs für eine große Klasse physikalisch vernetzter Systeme ermöglichen.
- 27 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 37 (4) , 2666-2678
Optimal Distributed Frequency and Voltage Control for Zonal Electricity Markets
Zonal pricing is a well-suited mechanism to incentivize grid-supporting behavior of profit-maximizing producers and consumers operating on a large-scale power system. In zonal electricity markets, local system operators create individual price zones, which provide appropriate price signals depending on local grid conditions such as an excess or shortage of electrical energy in certain regions. In this paper, a real-time zonal pricing controller for AC power networks is presented that ensures frequency and voltage stability as well as Pareto efficiency of the resulting closed-loop equilibria. Based on a dynamic network model that takes line losses and power exchange with adjacent price zones into account, distributed continuous-time control laws are derived which require only neighbor-to-neighbor communication. Application to a real-time congestion management strategy illustrates how spatially and temporally differentiated prices enable grid-supportive operation of the participants without interventions by a superordinate control authority. Effectiveness of different zonal pricing concepts compared to an isolated grid operation is demonstrated through simulations on the IEEE-57 bus system.
- 27 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 37 (4) , 2666-2678
Optimal Distributed Frequency and Voltage Control for Zonal Electricity Markets
Zonal pricing is a well-suited mechanism to incentivize grid-supporting behavior of profit-maximizing producers and consumers operating on a large-scale power system. In zonal electricity markets, local system operators create individual price zones, which provide appropriate price signals depending on local grid conditions such as an excess or shortage of electrical energy in certain regions. In this paper, a real-time zonal pricing controller for AC power networks is presented that ensures frequency and voltage stability as well as Pareto efficiency of the resulting closed-loop equilibria. Based on a dynamic network model that takes line losses and power exchange with adjacent price zones into account, distributed continuous-time control laws are derived which require only neighbor-to-neighbor communication. Application to a real-time congestion management strategy illustrates how spatially and temporally differentiated prices enable grid-supportive operation of the participants without interventions by a superordinate control authority. Effectiveness of different zonal pricing concepts compared to an isolated grid operation is demonstrated through simulations on the IEEE-57 bus system.
- Open Access
- 8 July 2021
- Published by MDPI AG in Mathematics
- Vol. 9 (14) , 1607
Parameter and Order Identification of Fractional Systems with Application to a Lithium-Ion Battery
This paper deals with a method for the parameter and order identification of a fractional model. In contrast to existing approaches that can either handle noisy observations of the output signal or systems that are not at rest, the proposed method does not have to compromise between these two characteristics. To handle systems that are not at rest, the parameter, as well as the order identification, are based on the modulating function method. The novelty of the proposed method is that an optimization-based approach is used for the order identification. Thus, even if only noisy observations of the output signal are available, an approximate identification can be performed. The proposed identification method is, then, applied to identify the parameters and orders of a lithium-ion battery model. The experimental results illustrate the practical usefulness and verify the validity of our approach.
- 8 July 2021
- Published by MDPI AG in Mathematics
- Vol. 9 (14) , 1607
Open AccessParameter and Order Identification of Fractional Systems with Application to a Lithium-Ion Battery
This paper deals with a method for the parameter and order identification of a fractional model. In contrast to existing approaches that can either handle noisy observations of the output signal or systems that are not at rest, the proposed method does not have to compromise between these two characteristics. To handle systems that are not at rest, the parameter, as well as the order identification, are based on the modulating function method. The novelty of the proposed method is that an optimization-based approach is used for the order identification. Thus, even if only noisy observations of the output signal are available, an approximate identification can be performed. The proposed identification method is, then, applied to identify the parameters and orders of a lithium-ion battery model. The experimental results illustrate the practical usefulness and verify the validity of our approach.
- 8 July 2020
- Published by Elsevier in Automatica
- Vol. 120, 109121
Explicit port-Hamiltonian formulation of multi-bond graphs for an automated model generation
- 8 July 2020
- Published by Elsevier in Automatica
- Vol. 120, 109121
Explicit port-Hamiltonian formulation of multi-bond graphs for an automated model generation
- Open Access
- 1 January 2020
- Published by Elsevier in IFAC-PapersOnLine
- Vol. 53 (2) , 5579-5585
Explicit Port-Hamiltonian Formulation of Bond Graphs with Dependent Storages
- 1 January 2020
- Published by Elsevier in IFAC-PapersOnLine
- Vol. 53 (2) , 5579-5585
Open AccessExplicit Port-Hamiltonian Formulation of Bond Graphs with Dependent Storages
- Open Access
Full- and Reduced-Order State-Space Modeling of Wind Turbine Systems with Permanent Magnet Synchronous Generator
Full-order state-space models represent the starting point for the development of advanced control methods for wind turbine systems (WTSs). Regarding existing control-oriented WTS models, two research gaps must be noted: (i) There exists no full-order WTS model in form of one overall ordinary differential equation that considers all dynamical effects which significantly influence the electrical power output; (ii) all existing reduced-order WTS models are subject to rather arbitrary simplifications and are not validated against a full-order model. Therefore, in this paper, two full-order nonlinear state-space models (of 11th and 9th-order in the ()- and ()-reference frame, resp.) for variable-speed variable-pitch permanent magnet synchronous generator WTSs are derived. The full-order models cover all relevant dynamical effects with significant impact on the system’s power output, including the switching behavior of the power electronic devices. Based on the full-order models, by a step-by-step model reduction procedure, two reduced-order WTS models are deduced: A non-switching (averaging) 7th-order WTS model and a non-switching 3rd-order WTS model. Comparative simulation results reveal that all models capture the dominant system dynamics properly. The full-order models allow for a detailed analysis covering the high frequency oscillations in the instantaneous power output due to the switching in the power converters. The reduced-order models provide a time-averaged instantaneous power output (which still correctly reflects the energy produced by the WTS) and come with a drastically reduced complexity making those models appropriate for large-scale power grid controller design.Open AccessFull- and Reduced-Order State-Space Modeling of Wind Turbine Systems with Permanent Magnet Synchronous Generator
Full-order state-space models represent the starting point for the development of advanced control methods for wind turbine systems (WTSs). Regarding existing control-oriented WTS models, two research gaps must be noted: (i) There exists no full-order WTS model in form of one overall ordinary differential equation that considers all dynamical effects which significantly influence the electrical power output; (ii) all existing reduced-order WTS models are subject to rather arbitrary simplifications and are not validated against a full-order model. Therefore, in this paper, two full-order nonlinear state-space models (of 11th and 9th-order in the ()- and ()-reference frame, resp.) for variable-speed variable-pitch permanent magnet synchronous generator WTSs are derived. The full-order models cover all relevant dynamical effects with significant impact on the system’s power output, including the switching behavior of the power electronic devices. Based on the full-order models, by a step-by-step model reduction procedure, two reduced-order WTS models are deduced: A non-switching (averaging) 7th-order WTS model and a non-switching 3rd-order WTS model. Comparative simulation results reveal that all models capture the dominant system dynamics properly. The full-order models allow for a detailed analysis covering the high frequency oscillations in the instantaneous power output due to the switching in the power converters. The reduced-order models provide a time-averaged instantaneous power output (which still correctly reflects the energy produced by the WTS) and come with a drastically reduced complexity making those models appropriate for large-scale power grid controller design. - Open Access
Full- & Reduced-Order State-Space Modeling of Wind Turbine Systems with Permanent-Magnet Synchronous Generator
Wind energy is an integral part of nowadays energy supply and one of the fastest growing sources of electricity in the world today. Accurate models for wind energy conversion systems (WECSs) are of key interest for the analysis and control design of present and future energy systems. Existing control-oriented WECSs models are subject to unstructured simplifications, which have not been discussed in literature so far. Thus, this technical note presents are thorough derivation of a physical state-space model for permanent magnet synchronous generator WECSs. The physical model considers all dynamic effects that significantly influence the system's power output, including the switching of the power electronics. Alternatively, the model is formulated in the $(a,b,c)$- and $(d,q)$-reference frame. Secondly, a complete control and operation management system for the wind regimes II and III and the transition between the regimes is presented. The control takes practical effects such as input saturation and integral windup into account. Thirdly, by a structured model reduction procedure, two state-space models of WECS with reduced complexity are derived: a non-switching model and a non-switching reduced-order model. The validity of the models is illustrated and compared through a numerical simulation study.
Open AccessFull- & Reduced-Order State-Space Modeling of Wind Turbine Systems with Permanent-Magnet Synchronous Generator
Wind energy is an integral part of nowadays energy supply and one of the fastest growing sources of electricity in the world today. Accurate models for wind energy conversion systems (WECSs) are of key interest for the analysis and control design of present and future energy systems. Existing control-oriented WECSs models are subject to unstructured simplifications, which have not been discussed in literature so far. Thus, this technical note presents are thorough derivation of a physical state-space model for permanent magnet synchronous generator WECSs. The physical model considers all dynamic effects that significantly influence the system's power output, including the switching of the power electronics. Alternatively, the model is formulated in the $(a,b,c)$- and $(d,q)$-reference frame. Secondly, a complete control and operation management system for the wind regimes II and III and the transition between the regimes is presented. The control takes practical effects such as input saturation and integral windup into account. Thirdly, by a structured model reduction procedure, two state-space models of WECS with reduced complexity are derived: a non-switching model and a non-switching reduced-order model. The validity of the models is illustrated and compared through a numerical simulation study.
- 1 January 2018
- Published by Elsevier in IFAC-PapersOnLine
- Vol. 51 (2) , 463-468
Towards Port-Hamiltonian Modeling of Multi-Carrier Energy Systems: A Case Study for a Coupled Electricity and Gas Distribution System
- 1 January 2018
- Published by Elsevier in IFAC-PapersOnLine
- Vol. 51 (2) , 463-468
Towards Port-Hamiltonian Modeling of Multi-Carrier Energy Systems: A Case Study for a Coupled Electricity and Gas Distribution System
- 1 September 2017
- Published by Springer Nature in Computer Science - Research and Development
- Vol. 33 (1-2) , 237-239
Poster abstract: graph-theoretic model for observability in multi-carrier energy distribution networks
- 1 September 2017
- Published by Springer Nature in Computer Science - Research and Development
- Vol. 33 (1-2) , 237-239
Poster abstract: graph-theoretic model for observability in multi-carrier energy distribution networks