Yun Jung Heo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Interests
Yun Jung Heo has a total of 80 co-authors. Here are the top co-authors by number of shared publications:
- Jumyung Um
Department of Artificial Intelligence, Kyung Hee University, Yongin-si, Gyeonggi-do, Republic of Korea
3 shared publications Yuna Han
Department of Mechanical Engineering, Kyung Hee University, Yongin-si, Republic of Korea
3 shared publications- Choongyeop Lee
Department of Mechanical Engineering (Integrated Engineering Program), Kyung Hee University 2 , Yongin 17104, South Korea
2 shared publications - Hidetoshi Takahashi
Keio University
2 shared publications - Inhee Choi
Department of Life Science, University of Seoul, Seoul, Republic of Korea
2 shared publications - Isao Shimoyama
The University of Tokyo, Tokyo, Japan
2 shared publications
Latest Publications
- 8 July 2025
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 288, 117766
Electrical grid-independent machine learning-assisted wearable gait analysis device with triboelectric-electromagnetic hybrid energy harvester
- 8 July 2025
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 288, 117766
Electrical grid-independent machine learning-assisted wearable gait analysis device with triboelectric-electromagnetic hybrid energy harvester
- 10 December 2024
- Published by Springer Nature in BioChip Journal
- Vol. 19 (1) , 62-78
Transdermal Drug Delivery System Using Light and Moisture Dual Responsive Hybrid Microneedles
- 10 December 2024
- Published by Springer Nature in BioChip Journal
- Vol. 19 (1) , 62-78
Transdermal Drug Delivery System Using Light and Moisture Dual Responsive Hybrid Microneedles
- Open Access
- 3 June 2024
- Published by Royal Society of Chemistry (RSC) in Soft Matter
- Vol. 20 (25) , 4988-4997
Highly porous hydrogels for efficient solar water evaporation
This study introduces a facile method for fabricating hydrophilic 3D-network hydrogels, integrating plasmonic gold nanoparticles to boost solar absorption, enhancing evaporation rates and solar efficiency to 1.6 kg m−2 h−1 and 77%, respectively.
- 3 June 2024
- Published by Royal Society of Chemistry (RSC) in Soft Matter
- Vol. 20 (25) , 4988-4997
Open AccessHighly porous hydrogels for efficient solar water evaporation
This study introduces a facile method for fabricating hydrophilic 3D-network hydrogels, integrating plasmonic gold nanoparticles to boost solar absorption, enhancing evaporation rates and solar efficiency to 1.6 kg m−2 h−1 and 77%, respectively.
- 1 October 2023
- Published by AIP Publishing in Physics of Fluids
- Vol. 35 (10)
Passive control of flow rate change due to the input pressure fluctuation based on microchannel deformation
Precise and controlled drug delivery is crucial in continuous infusion systems used for drug treatment, anesthesia, cancer chemotherapy, and pain management. Elastometric pumps are commonly utilized in continuous infusion systems for their ease of use and cost-effectiveness. However, the infusion accuracy is often compromised due to the fluctuating supply pressure of elastomeric pumps, requiring an additional flow regulator to stabilize the output flow rate. We, here, present a novel approach to passively control a flow rate even under the fluctuating pressure environment based on a channel deformation. The flow rate control is enabled by a flow regulator consisting of an open-end microchannel, a closed-end microchannel, and a flexible membrane in the middle. The pressure within an open-end microchannel decreases in the downstream direction, while the pressure within a closed-end microchannel remains equal to the input pressure, creating the pressure difference between the two channels. The membrane deforms in response to this pressure difference, allowing for adjustment of the output flow rate by decreasing the flow path area with the increase in the input pressure. It is found that this concept successfully works by maintaining a steady output flow rate over a target pressure range of 40–50 kPa. Fluid–structure interaction numerical simulations and theoretical analysis are used to explain the flow rate control mechanism of the device. The results show that the present approach offers a promising solution for achieving stable drug delivery in continuous drug infusion systems, addressing the limitations of conventional elastomeric pumps.
- 1 October 2023
- Published by AIP Publishing in Physics of Fluids
- Vol. 35 (10)
Passive control of flow rate change due to the input pressure fluctuation based on microchannel deformation
Precise and controlled drug delivery is crucial in continuous infusion systems used for drug treatment, anesthesia, cancer chemotherapy, and pain management. Elastometric pumps are commonly utilized in continuous infusion systems for their ease of use and cost-effectiveness. However, the infusion accuracy is often compromised due to the fluctuating supply pressure of elastomeric pumps, requiring an additional flow regulator to stabilize the output flow rate. We, here, present a novel approach to passively control a flow rate even under the fluctuating pressure environment based on a channel deformation. The flow rate control is enabled by a flow regulator consisting of an open-end microchannel, a closed-end microchannel, and a flexible membrane in the middle. The pressure within an open-end microchannel decreases in the downstream direction, while the pressure within a closed-end microchannel remains equal to the input pressure, creating the pressure difference between the two channels. The membrane deforms in response to this pressure difference, allowing for adjustment of the output flow rate by decreasing the flow path area with the increase in the input pressure. It is found that this concept successfully works by maintaining a steady output flow rate over a target pressure range of 40–50 kPa. Fluid–structure interaction numerical simulations and theoretical analysis are used to explain the flow rate control mechanism of the device. The results show that the present approach offers a promising solution for achieving stable drug delivery in continuous drug infusion systems, addressing the limitations of conventional elastomeric pumps.
- Top Cited PapersOpen Access
- 2 June 2023
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 9 (22) , eadh1765
Fluorescent-based biodegradable microneedle sensor array for tether-free continuous glucose monitoring with smartphone application
Continuous glucose monitoring (CGM) allows patients with diabetes to manage critical disease effectively and autonomously and prevent exacerbation. A painless, wireless, compact, and minimally invasive device that can provide CGM is essential for monitoring the health conditions of freely moving patients with diabetes. Here, we propose a glucose-responsive fluorescence-based highly sensitive biodegradable microneedle CGM system. These ultrathin and ultralight microneedle sensor arrays continuously and precisely monitored glucose concentration in the interstitial fluid with minimally invasive, pain-free, wound-free, and skin inflammation–free outcomes at various locations and thicknesses of the skin. Bioresorbability in the body without a need for device removal after use was a key characteristic of the microneedle glucose sensor. We demonstrated the potential long-term use of the bioresorbable device by applying the tether-free CGM system, thus confirming the successful detection of glucose levels based on changes in fluorescence intensity. In addition, this microneedle glucose sensor with a user-friendly designed home diagnosis system using mobile applications and portable accessories offers an advance in CGM and its applicability to other bioresorbable, wearable, and implantable monitoring device technology.
- 2 June 2023
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 9 (22) , eadh1765
Top Cited PapersOpen AccessFluorescent-based biodegradable microneedle sensor array for tether-free continuous glucose monitoring with smartphone application
Continuous glucose monitoring (CGM) allows patients with diabetes to manage critical disease effectively and autonomously and prevent exacerbation. A painless, wireless, compact, and minimally invasive device that can provide CGM is essential for monitoring the health conditions of freely moving patients with diabetes. Here, we propose a glucose-responsive fluorescence-based highly sensitive biodegradable microneedle CGM system. These ultrathin and ultralight microneedle sensor arrays continuously and precisely monitored glucose concentration in the interstitial fluid with minimally invasive, pain-free, wound-free, and skin inflammation–free outcomes at various locations and thicknesses of the skin. Bioresorbability in the body without a need for device removal after use was a key characteristic of the microneedle glucose sensor. We demonstrated the potential long-term use of the bioresorbable device by applying the tether-free CGM system, thus confirming the successful detection of glucose levels based on changes in fluorescence intensity. In addition, this microneedle glucose sensor with a user-friendly designed home diagnosis system using mobile applications and portable accessories offers an advance in CGM and its applicability to other bioresorbable, wearable, and implantable monitoring device technology.
- Open Access
- 20 January 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (3) , 1390
A Deep-Learning Approach for Identifying a Drunk Person Using Gait Recognition
Various accidents caused by alcohol consumption have recently increased in prevalence and have become a huge social problem. There have been efforts to identify drunk individuals using mobile devices; however, it is difficult to apply this method to a large number of people. A promising approach that does not involve wearing any sensors or subject cooperation is a markerless, vision-based method that only requires a camera to classify a drunk gait. Herein, we first propose a markerless, vision-based method to determine whether a human is drunk or not based on his or her gait pattern. We employed a convolutional neural network to analyze gait patterns with image augmentation depending on gait energy images. Gait images captured through a camera allow a complex neural network to detect the human body shape accurately. It is necessary for removing the background behind human shape in the gait image because it disrupts the detection algorithm. A process of conversion into gait energy images and augmenting image data is then applied to the dataset of the gait images. A total of 20 participants participated in the experiment. They were required to walk along a line both with and without wearing the Drunk Busters Goggles, which were intended to collect sober and drunk gait images. Validation accuracy for the recognition of a drunk state in 20 persons was approximately 74.94% under optimal conditions. If the present approach fulfills its promise, we can prevent safety accidents due to alcohol, thus decreasing its burden on industries and society.
- 20 January 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (3) , 1390
Open AccessA Deep-Learning Approach for Identifying a Drunk Person Using Gait Recognition
Various accidents caused by alcohol consumption have recently increased in prevalence and have become a huge social problem. There have been efforts to identify drunk individuals using mobile devices; however, it is difficult to apply this method to a large number of people. A promising approach that does not involve wearing any sensors or subject cooperation is a markerless, vision-based method that only requires a camera to classify a drunk gait. Herein, we first propose a markerless, vision-based method to determine whether a human is drunk or not based on his or her gait pattern. We employed a convolutional neural network to analyze gait patterns with image augmentation depending on gait energy images. Gait images captured through a camera allow a complex neural network to detect the human body shape accurately. It is necessary for removing the background behind human shape in the gait image because it disrupts the detection algorithm. A process of conversion into gait energy images and augmenting image data is then applied to the dataset of the gait images. A total of 20 participants participated in the experiment. They were required to walk along a line both with and without wearing the Drunk Busters Goggles, which were intended to collect sober and drunk gait images. Validation accuracy for the recognition of a drunk state in 20 persons was approximately 74.94% under optimal conditions. If the present approach fulfills its promise, we can prevent safety accidents due to alcohol, thus decreasing its burden on industries and society.
- Open Access
Batteryless, Miniaturized Implantable Glucose Sensor Using a Fluorescent Hydrogel
We propose a biomedical sensor system for continuous monitoring of glucose concentration. Despite recent advances in implantable biomedical devices, mm sized devices have yet to be developed due to the power limitation of the device in a tissue. We here present a mm sized wireless system with backscattered frequency-modulation communication that enables a low-power operation to read the glucose level from a fluorescent hydrogel sensor. The configuration of the reader structure is optimized for an efficient wireless power transfer and data communication, miniaturizing the entire implantable device to 3 × 6 mm size. The operation distance between the reader and the implantable device reaches 2 mm with a transmission power of 33 dBm. We demonstrate that the frequency of backscattered signals changes according to the light intensity of the fluorescent glucose sensor. We envision that the present wireless interface can be applied to other fluorescence-based biosensors to make them highly comfortable, biocompatible, and stable within a body.Open AccessBatteryless, Miniaturized Implantable Glucose Sensor Using a Fluorescent Hydrogel
We propose a biomedical sensor system for continuous monitoring of glucose concentration. Despite recent advances in implantable biomedical devices, mm sized devices have yet to be developed due to the power limitation of the device in a tissue. We here present a mm sized wireless system with backscattered frequency-modulation communication that enables a low-power operation to read the glucose level from a fluorescent hydrogel sensor. The configuration of the reader structure is optimized for an efficient wireless power transfer and data communication, miniaturizing the entire implantable device to 3 × 6 mm size. The operation distance between the reader and the implantable device reaches 2 mm with a transmission power of 33 dBm. We demonstrate that the frequency of backscattered signals changes according to the light intensity of the fluorescent glucose sensor. We envision that the present wireless interface can be applied to other fluorescence-based biosensors to make them highly comfortable, biocompatible, and stable within a body.