Chikahiro Imashiro
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Chikahiro Imashiro has a total of 74 co-authors. Here are the top co-authors by number of shared publications:
- Kenjiro Takemura
Department of Mechanical Engineering Keio University Yokohama Kanagawa Japan
18 shared publications - Yuta Kurashina
Division of Advanced Mechanical Systems Engineering, Institute of Engineering, Tokyo University of Agriculture and Technology, Tokyo, Japan
8 shared publications Kiichiro Totani
Department of Materials and Life Science Faculty of Science and Technology, Seikei University Tokyo Musashino‐shi Japan
7 shared publicationsYuta Kurashina
Affiliation Department of Materials Science and Engineering, School of Materials and Chemical Technology, Tokyo institute of Technology, Yokohama, Kanagawa, Japan
6 shared publicationsTaiki Kuribara
Department of Materials and Life Science Faculty of Science and Technology, Seikei University Tokyo Musashino‐shi Japan
5 shared publicationsJun Komotori
Department of Mechanical Engineering, Faculty of Science and Technology, Keio University
4 shared publications
Latest Publications
- Open Access
- 26 June 2026
- Published by Elsevier in SSRN Electronic Journal
High-Performance Acoustofluidic Blood Plasma Separation Devices Driven by an Algorithm-Optimized ElLIPtical Reflector Focusing Ultrasonic TranSducer (ELIPS)
Blood plasma separation is a fundamental step in point-of-care diagnostics and testing. However, conventional centrifugation relies on bulky equipment and multiple manual handling, while most microfluidic methods struggle to achieve high purity, high throughput, and high plasma yield simultaneously. In this study, we demonstrate a high-performance acoustofluidic plasma separation device satisfying three requirements driven by an algorithm-optimized ElLIPtical reflector focusing ultrasonic tranSducer (ELIPS). The genetic algorithm was used as a design tool to preserve strong acoustic performance while reducing the device footprint. Simulations show that the device size was reduced by a factor of 2.3, suitable for lab-on-chip integration, while achieving a 1.7-fold improvement in simulated device efficiency compared with previous reflector-based designs. Experiments validate approximately a 58.3% improvement in practical device efficiency, evidenced by perfect focusing of 5-µm-diameter polystyrene particles at a flow rate of 3 mL/min using only 500 mW. Continuous plasma separation from whole blood was further achieved using a double-stage microfluidic chip driven by two ELIPSs, with a plasma collection rate of 40 μL/min and a plasma yield of 26.7%, while maintaining the chip temperature below 37 °C. The collected plasma exhibits nearly 100% blood cell removal rate and an average platelet separation efficiency of 95%, meeting clinical standards. To the best of our knowledge, this represents the highest throughput on blood plasma separation among acoustofluidic systems that meet clinical requirements, offering a good combination of high throughput, high purity, and high plasma yield. These results highlight the potential of reflector-based acoustofluidic systems for point-of-care applications.
- 26 June 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessHigh-Performance Acoustofluidic Blood Plasma Separation Devices Driven by an Algorithm-Optimized ElLIPtical Reflector Focusing Ultrasonic TranSducer (ELIPS)
Blood plasma separation is a fundamental step in point-of-care diagnostics and testing. However, conventional centrifugation relies on bulky equipment and multiple manual handling, while most microfluidic methods struggle to achieve high purity, high throughput, and high plasma yield simultaneously. In this study, we demonstrate a high-performance acoustofluidic plasma separation device satisfying three requirements driven by an algorithm-optimized ElLIPtical reflector focusing ultrasonic tranSducer (ELIPS). The genetic algorithm was used as a design tool to preserve strong acoustic performance while reducing the device footprint. Simulations show that the device size was reduced by a factor of 2.3, suitable for lab-on-chip integration, while achieving a 1.7-fold improvement in simulated device efficiency compared with previous reflector-based designs. Experiments validate approximately a 58.3% improvement in practical device efficiency, evidenced by perfect focusing of 5-µm-diameter polystyrene particles at a flow rate of 3 mL/min using only 500 mW. Continuous plasma separation from whole blood was further achieved using a double-stage microfluidic chip driven by two ELIPSs, with a plasma collection rate of 40 μL/min and a plasma yield of 26.7%, while maintaining the chip temperature below 37 °C. The collected plasma exhibits nearly 100% blood cell removal rate and an average platelet separation efficiency of 95%, meeting clinical standards. To the best of our knowledge, this represents the highest throughput on blood plasma separation among acoustofluidic systems that meet clinical requirements, offering a good combination of high throughput, high purity, and high plasma yield. These results highlight the potential of reflector-based acoustofluidic systems for point-of-care applications.
- Open Access
- 3 November 2025
- Published by Elsevier in Ultrasonics
- Vol. 159, 107883
Bidirectional excitation and detection of Rayleigh waves via two facing elliptical reflectors
- 3 November 2025
- Published by Elsevier in Ultrasonics
- Vol. 159, 107883
Open AccessBidirectional excitation and detection of Rayleigh waves via two facing elliptical reflectors
- Open Access
- 4 August 2025
- Published by Wiley in Advanced Biology
- Vol. 9 (8) , e00092
Spheroid Cell Aggregation Enhanced by Enzyme‐Free Ultrasound‐Detached Cells
Spheroids are being widely studied as potential building blocks for complex organ engineering, tools for drug screening and cancer study. However, formation time has become the bottleneck of applications due to the need for large‐scale high‐quality spheroids production. Formation time is often dominated by ECM construction and not cell aggregation. Therefore, this study focuses on the influence of ultrasound detachment replacing conventional enzyme detachment on spheroid formation processes. Thanks to cell surface protein preservation in ultrasound detachment, cell aggregation time is reduced while decreasing the formation variabilities. Moreover, it is confirmed that cells are intrinsically more capable of aggregating through enzyme‐free detachment. On top of that, transplantations into rats showed equally successful engraftment properties for enzyme‐free detached cells. Finally, the impact on the real co‐cultured spheroid application was shown to be beneficial through more localized cell groups inside of the spheroids, possibly improving therapeutic effects and vascularization. Through this study, it is proved that ultrasound detachment can replace enzyme detachment without degrading the final spheroid properties but reducing the formation time, and variability and improving robustness and cell distribution. This opens up a new range of applications for better and faster spheroid formation in numerous bioengineering applications.
- 4 August 2025
- Published by Wiley in Advanced Biology
- Vol. 9 (8) , e00092
Open AccessSpheroid Cell Aggregation Enhanced by Enzyme‐Free Ultrasound‐Detached Cells
Spheroids are being widely studied as potential building blocks for complex organ engineering, tools for drug screening and cancer study. However, formation time has become the bottleneck of applications due to the need for large‐scale high‐quality spheroids production. Formation time is often dominated by ECM construction and not cell aggregation. Therefore, this study focuses on the influence of ultrasound detachment replacing conventional enzyme detachment on spheroid formation processes. Thanks to cell surface protein preservation in ultrasound detachment, cell aggregation time is reduced while decreasing the formation variabilities. Moreover, it is confirmed that cells are intrinsically more capable of aggregating through enzyme‐free detachment. On top of that, transplantations into rats showed equally successful engraftment properties for enzyme‐free detached cells. Finally, the impact on the real co‐cultured spheroid application was shown to be beneficial through more localized cell groups inside of the spheroids, possibly improving therapeutic effects and vascularization. Through this study, it is proved that ultrasound detachment can replace enzyme detachment without degrading the final spheroid properties but reducing the formation time, and variability and improving robustness and cell distribution. This opens up a new range of applications for better and faster spheroid formation in numerous bioengineering applications.
- 30 June 2025
- Published by AIP Publishing in Applied Physics Letters
- Vol. 126 (26)
Resonant excitation of a thin waveguide with an elliptical reflector for high-power ultrasound (ELIPS)
High-power ultrasound plays a critical role in various applications, yet generating multi-frequency ultrasound in a localized area with a single transducer remains a significant challenge. We propose a transducer with an elliptical reflector to excite a thin waveguide at multiple frequencies within the megahertz range. The elliptical reflector transforms a plane dilatational wave from the piezoelectric elements into a transverse wave, focused on the thin waveguide using mode conversion. The use of transverse waves reduces energy loss during the reflection process and achieves a smaller focal diameter. Finite element analysis verified wave focusing with the elliptical reflector and the thin waveguide excitation. The fabricated prototype achieved high vibration velocities at the central tip of the waveguide, including 6.7 m/s at 1.767 MHz and 12.8 m/s at 0.411 MHz. At 1.767 MHz, the vibration velocity increased linearly with increasing applied voltage, suggesting the potential for achieving even higher velocities with greater energy input. At 0.411 MHz, the stress within the thin waveguide was expected to exceed the material's tensile strength, indicating that the design maximized the material's performance limits.
- 30 June 2025
- Published by AIP Publishing in Applied Physics Letters
- Vol. 126 (26)
Resonant excitation of a thin waveguide with an elliptical reflector for high-power ultrasound (ELIPS)
High-power ultrasound plays a critical role in various applications, yet generating multi-frequency ultrasound in a localized area with a single transducer remains a significant challenge. We propose a transducer with an elliptical reflector to excite a thin waveguide at multiple frequencies within the megahertz range. The elliptical reflector transforms a plane dilatational wave from the piezoelectric elements into a transverse wave, focused on the thin waveguide using mode conversion. The use of transverse waves reduces energy loss during the reflection process and achieves a smaller focal diameter. Finite element analysis verified wave focusing with the elliptical reflector and the thin waveguide excitation. The fabricated prototype achieved high vibration velocities at the central tip of the waveguide, including 6.7 m/s at 1.767 MHz and 12.8 m/s at 0.411 MHz. At 1.767 MHz, the vibration velocity increased linearly with increasing applied voltage, suggesting the potential for achieving even higher velocities with greater energy input. At 0.411 MHz, the stress within the thin waveguide was expected to exceed the material's tensile strength, indicating that the design maximized the material's performance limits.
- Open Access
- 16 May 2025
- Published by Wiley in FEBS Open Bio
- Vol. 15 (8) , 1365-1375
Profiling the effect of low frequency mechanical vibration on the metabolic and oxidative stress responses of A431 carcinoma
Mechanomedicine represents a potential biocompatible method in cancer therapy. In particular, the use of low‐frequency mechanical vibration previously proved to trigger apoptosis of the human epidermoid carcinoma A431 cell line. In this study, we further characterized the metabolic and oxidative stress responses triggered by 1 h of 20 Hz mechanical vibration stimulus to A431 prior to cell death. Our results indicate that cell death may be related to the decrease of glucose consumption rate and the higher expression of reactive oxygen species right after mechanical stimulation (0 h). The overexpression of HMGB1 and HSP70 coding genes signified the increase of A431 cell stress. However, HMGB1 and HSP70 expression decreased at 24 h after mechanical vibration, along with the progression of cell death. We also observed cell morphology changes on A431 cells following vibration which might be indicative of A431 death by apoptosis. The emergence of these stress responses suggests that several pathways are connected to promote cancer cell death. The discovery of A431 cellular stress symptoms which lead to apoptotic death may clarify the usefulness of mechanical vibration in cancer treatment as a novel application of biomechanical manipulation.
- 16 May 2025
- Published by Wiley in FEBS Open Bio
- Vol. 15 (8) , 1365-1375
Open AccessProfiling the effect of low frequency mechanical vibration on the metabolic and oxidative stress responses of A431 carcinoma
Mechanomedicine represents a potential biocompatible method in cancer therapy. In particular, the use of low‐frequency mechanical vibration previously proved to trigger apoptosis of the human epidermoid carcinoma A431 cell line. In this study, we further characterized the metabolic and oxidative stress responses triggered by 1 h of 20 Hz mechanical vibration stimulus to A431 prior to cell death. Our results indicate that cell death may be related to the decrease of glucose consumption rate and the higher expression of reactive oxygen species right after mechanical stimulation (0 h). The overexpression of HMGB1 and HSP70 coding genes signified the increase of A431 cell stress. However, HMGB1 and HSP70 expression decreased at 24 h after mechanical vibration, along with the progression of cell death. We also observed cell morphology changes on A431 cells following vibration which might be indicative of A431 death by apoptosis. The emergence of these stress responses suggests that several pathways are connected to promote cancer cell death. The discovery of A431 cellular stress symptoms which lead to apoptotic death may clarify the usefulness of mechanical vibration in cancer treatment as a novel application of biomechanical manipulation.
- Open Access
- 2 April 2025
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 436
High-throughput acoustofluidic device driven by an ElLIPtical Reflector Focusing Ultrasonic TranSducer (ELIPS)
- 2 April 2025
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 436
Open AccessHigh-throughput acoustofluidic device driven by an ElLIPtical Reflector Focusing Ultrasonic TranSducer (ELIPS)
- Open Access
- 1 January 2025
- Published by Japanese Society for Medical and Biological Engineering in Advanced Biomedical Engineering
- Vol. 14, 126-133
Regulating Cell Orientation Using a Femtosecond Laser-Induced Macro Stripe Design on Metallic Culture Surfaces with Laser-Treated and Mirrored Areas
Controlling cell orientation is of paramount importance in bioengineering processes. While several surface modification techniques have emerged to guide cell orientation, they often involve complex, repetitive procedures for each experiment. Thus, a streamlined approach for cell orientation is necessary. In this study, we present a potentially reusable metallic culture surface that induces an anisotropic cell orientation due to its unique geometric morphology. Using a femtosecond laser, periodic nanostructures were produced on the metallic culture surface, resulting in a distinctive macro stripe design composed of both laser-treated and mirrored areas. Myoblast cells cultured on this surface showed a pronounced orientation. The macro stripe design provided stronger control of cell orientation compared to the simple laser-treated surface with periodic nanostructures. Initial random cell adherence was followed by migration toward the mirror surface, culminating in the desired orientation. This shift can be attributed to the mirrored areas providing superior cell adhesion and reduced wettability compared to the laser-treated areas. This innovative culture surface has significant potential for advancing bioengineering endeavors, especially in the field of tissue engineering.
- 1 January 2025
- Published by Japanese Society for Medical and Biological Engineering in Advanced Biomedical Engineering
- Vol. 14, 126-133
Open AccessRegulating Cell Orientation Using a Femtosecond Laser-Induced Macro Stripe Design on Metallic Culture Surfaces with Laser-Treated and Mirrored Areas
Controlling cell orientation is of paramount importance in bioengineering processes. While several surface modification techniques have emerged to guide cell orientation, they often involve complex, repetitive procedures for each experiment. Thus, a streamlined approach for cell orientation is necessary. In this study, we present a potentially reusable metallic culture surface that induces an anisotropic cell orientation due to its unique geometric morphology. Using a femtosecond laser, periodic nanostructures were produced on the metallic culture surface, resulting in a distinctive macro stripe design composed of both laser-treated and mirrored areas. Myoblast cells cultured on this surface showed a pronounced orientation. The macro stripe design provided stronger control of cell orientation compared to the simple laser-treated surface with periodic nanostructures. Initial random cell adherence was followed by migration toward the mirror surface, culminating in the desired orientation. This shift can be attributed to the mirrored areas providing superior cell adhesion and reduced wettability compared to the laser-treated areas. This innovative culture surface has significant potential for advancing bioengineering endeavors, especially in the field of tissue engineering.
- Open Access
- 19 November 2024
- Published by Elsevier in Ultrasonics Sonochemistry
- Vol. 112, 107166
Effect of driving frequency and power on droplet size atomized by a multimodal transducer
- 19 November 2024
- Published by Elsevier in Ultrasonics Sonochemistry
- Vol. 112, 107166
Open AccessEffect of driving frequency and power on droplet size atomized by a multimodal transducer
- Open Access
Regulating Cell Orientation with a Femtosecond Laser-Induced Macro Stripe Design on Metallic Culture Surfaces
Controlling cell orientation is paramount in bioengineering processes. While several surface modification techniques have emerged to guide cell alignment, they often involve complex, repetitive procedures for each experiment. A streamlined approach for cell orientation is thus necessary. In this study, we present a reusable metallic culture surface that induces an anisotropic cell orientation, attributed to its unique geometric morphology. By employing a femtosecond laser, periodic nanostructures were produced on the metallic culture surface, leading to a distinctive macro-stripe design composed of both laser-treated and mirrored areas. Myoblast cells cultured on this surface displayed a pronounced orientation. Initial random cell adherence was followed by migration towards the mirror surface, culminating in the desired orientation. This shift can be credited to the mirrored sections offering superior cell adhesion and reduced wettability compared to the laser-treated sections. This innovative culture surface holds significant potential for advancing bioengineering endeavors, especially in the realm of tissue engineering.
Open AccessRegulating Cell Orientation with a Femtosecond Laser-Induced Macro Stripe Design on Metallic Culture Surfaces
Controlling cell orientation is paramount in bioengineering processes. While several surface modification techniques have emerged to guide cell alignment, they often involve complex, repetitive procedures for each experiment. A streamlined approach for cell orientation is thus necessary. In this study, we present a reusable metallic culture surface that induces an anisotropic cell orientation, attributed to its unique geometric morphology. By employing a femtosecond laser, periodic nanostructures were produced on the metallic culture surface, leading to a distinctive macro-stripe design composed of both laser-treated and mirrored areas. Myoblast cells cultured on this surface displayed a pronounced orientation. Initial random cell adherence was followed by migration towards the mirror surface, culminating in the desired orientation. This shift can be credited to the mirrored sections offering superior cell adhesion and reduced wettability compared to the laser-treated sections. This innovative culture surface holds significant potential for advancing bioengineering endeavors, especially in the realm of tissue engineering.
- Open Access
- 1 January 2023
- Published by American Association for the Advancement of Science (AAAS) in Cyborg and Bionic Systems
- Vol. 4, 0049
Titanium Culture Vessel Presenting Temperature Gradation for the Thermotolerance Estimation of Cells
Hyperthermia can be induced to exploit the thermal intolerance of cancer cells, which is worse than that of normal cells, as a potential noninvasive cancer treatment. To develop an effective hyperthermia treatment, thermal cytotoxicity of cells should be comprehensively investigated. However, to conduct such investigations, the culture temperature must be accurately regulated. We previously reported a culture system in which the culture temperature could be accurately regulated by employing metallic culture vessels. However, appropriate temperature conditions for hyperthermia depend on the cell species. Consequently, several experiments need to be conducted, which is a bottleneck of inducing hyperthermia. Hence, we developed a cell culture system with temperature gradation on a metallic culture surface. Michigan Cancer Foundation-7 cells and normal human dermal fibroblasts were used as cancer and normal cell models, respectively. Normal cells showed stronger thermal tolerance; this was because the novel system immediately exhibited a temperature gradation. Thus, the developed culture system can be used to investigate the optimum thermal conditions for effective hyperthermia treatment. Furthermore, as the reactions of cultured cells can be effectively assessed with the present results, further research involving the thermal stimulation of cells is possible.
- 1 January 2023
- Published by American Association for the Advancement of Science (AAAS) in Cyborg and Bionic Systems
- Vol. 4, 0049
Open AccessTitanium Culture Vessel Presenting Temperature Gradation for the Thermotolerance Estimation of Cells
Hyperthermia can be induced to exploit the thermal intolerance of cancer cells, which is worse than that of normal cells, as a potential noninvasive cancer treatment. To develop an effective hyperthermia treatment, thermal cytotoxicity of cells should be comprehensively investigated. However, to conduct such investigations, the culture temperature must be accurately regulated. We previously reported a culture system in which the culture temperature could be accurately regulated by employing metallic culture vessels. However, appropriate temperature conditions for hyperthermia depend on the cell species. Consequently, several experiments need to be conducted, which is a bottleneck of inducing hyperthermia. Hence, we developed a cell culture system with temperature gradation on a metallic culture surface. Michigan Cancer Foundation-7 cells and normal human dermal fibroblasts were used as cancer and normal cell models, respectively. Normal cells showed stronger thermal tolerance; this was because the novel system immediately exhibited a temperature gradation. Thus, the developed culture system can be used to investigate the optimum thermal conditions for effective hyperthermia treatment. Furthermore, as the reactions of cultured cells can be effectively assessed with the present results, further research involving the thermal stimulation of cells is possible.