BWBao-Zhen Wang

Bao-Zhen Wang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Bao-Zhen Wang has a total of 27 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

    • 15 February 2009
      • Vol. 30  (2) , 421-6

    [Comparison of biological phosphorus removal between different systems using O2, NO3(-) and NO2(-) as electron acceptors].

    by Yi-Feng Jiang, Jian-Jun Zheng, Bao-Zhen Wang, Lin Wang, Jian-Meng Chen

    By parallel operation of three phosphorus removal systems (SBR) using different electron acceptors of O2, NO3(-) and NO2(-), process characteristics and inherent competition mechanism of microorganisms were discussed. Although NO2(-) had no direct inhibition on anoxic phosphorus uptake after the DPAO cultivation, system performance was still much lower than that with NO3(-) as electron acceptor. And it ultimately resulted from the washout of the group of DPAO (DPAO5) that lacked the ability to denitrify NO2(-) and the enhanced GAO growth in the system. Being the efficient electron acceptor, NO3(-) or O2 supplying SBRs removed phosphorus smoothly and comparatively, in viewpoint of stiochoimetry and constitution of functional bacteria. In all three test systems, mass of GAO was present to exhaust limited organics with PAO population. Moreover, total PAO could be divided into 6 distinct groups, i.e., PO, PN, Pn, PNn, PON and PONn, based on the abilities of utilizing different electron acceptors. And facultative PAO of PON and PONn were found as the main contributors for the phosphorus removal. The higher ratio they accounted in sludge, the more capacity the system possessed to remove phosphorus, i.e., SBR0 > SBRn5 > SBRn3.

  • Suspended particle effects on ultraviolet light disinfection of effluent and the improvement

    by J. L. Wang, L. Wang, B. Z. Wang, J. S. Zhang, W. Z. Huang

    The concentration of suspended solids of effluent from secondary clarifiers often varies in a wide range, therefore the dose of ultraviolet light (UV) disinfection process need to be adjusted to meet the disinfection criterion at high frequency, and the desired disinfection effect is difficult to be ensured. The particles size and particle-associated Fecal Coliform (F.C.) contribution, and their influence on UV disinfection effects were investigated, and chlorination/UV combined disinfection process (chlorination/UV disinfection process) was used. The results showed that suspended solids content has a major impact on UV disinfection efficiency, especially the large particle size fraction. D>10µm particles associated F.C. is difficult to be disinfected and is the main part of the tailings of F.C. inactivation curve. Pre-chlorination could reduce the number of particles in effluent, and make large particles decrease to small ones. Therefore, the influence of particles on UV disinfection could be reduced after pre-chlorination, and the resistance ability to particle loadings of combined process was enhanced. Furthermore, the combined process has the advantage of low toxicity, low operational/maintenance costs, and is easy to be established not only in wastewater plants constructed already but ones to be about to be constructed.

    • 1 January 2006
      • Vol. 18  (4) , 634-8

    Suspended particle effects on ClO2/ultraviolet light combined disinfection of effluent.

    by Jian-Ling Wang, Bao-Zhen Wang, Lin Wang, Jin-Song Zhang, Wen-Zhang Huang

    The concentration of suspended solids of effluent often varies in a wide range, therefore the dose of ultraviolet light (UV) in disinfection process needs to be adjusted to meet the disinfection criterion at a high frequency, and the desired disinfection effect is difficult to be ensured. The particles size and particle-associated fecal coliform (F.C.) contribution, and their influence on UV disinfection were investigated when ClO2 and UV combined disinfection process was used. The results showed that suspended solids content had a major impact on UV disinfection efficiency, especially the large particle size fraction. Particles (D>10 microm) associated F. C. were difficult to be disinfected and were the main part of the tailings of F.C. inactivation curve. Pre-ClO2 oxidation could reduce the number of particles in effluent, and make large particles decrease to small ones. Therefore, the influence of particles on UV disinfection could be reduced after pre-ClO2 oxidation, and the resistance ability to particle loadings of combined process was enhanced. Moreover, the combined process has a lot of advantages, such as low toxicity, low operational/maintenance costs; it is also convenient to be established in the existing wastewater plant or the new planned one.


  • Performance of an intensive pond system treating municipal wastewater in a cold region

    by B. Wang, P. Qi, L. Wang, W. Lu, S. Liu, F. Zhao

    A full-scale intensive pond system (IPS) with shorter HRT was designed, constructed and operated in Jining, Inner-Mongolia for the treatment of municipal wastewater, which is a mixed domestic and industrial wastewater characterized by quite high SS and lower BOD5/COD ratio values or lower biodegradability. Therefore, the pond system was designed as an integrated intensive pond system (IIPS) consisting of settling/anaerobic pond (SAP), intensified anaerobic pond (IAP), facultative pond (FP), and polishing ponds (PPs). In order to improve the performance of the IPS, some intensified measures were made, including inlet and outlet even-distribution systems of each unit pond, package of biofilm carrier in IAP for the increase and even distribution of biomass; overflow waterfalls on the dikes between unit ponds for the increase of DO in pond water, gravel filtration dike (or dam) for removing suspended solids including algae, which have improved the performance of the IPS remarkably in terms of removal of main pollutants, such as SS, COD, BOD5, TN, NH3-N, TP and total bacteria. The final effluent from the IPS in warm seasons from May to October were SS 7.2–10.8 mg/L, BOD5 8.5–19.6 mg/L, COD 44.1–76.5 mg/L, and NH3-N 1.5–10.2 mg/L, which well meet Chinese national discharge standard (2nd class) of secondary municipal wastewater treatment plants, i.e. BOD5 and SS 30 mg/L respectively, COD 100 mg/L, and NH3-N 25 mg/L.


  • Municipal wastewater treatment with pond–constructed wetland system: a case study

    by X. Wang, X. Bai, J. Qiu, B. Wang

    The performance of a pond–constructed wetland system in the treatment of municipal wastewater in Kiaochow city was studied; and comparison with oxidation ponds system was conducted. In the post-constructed wetland, the removal of COD, TN and TP is 24%, 58.5% and 24.8% respectively. The treated effluent from the constructed wetland can meet the Chinese National Agricultural and Irrigation Standard. The comparison between pond–constructed wetland system and oxidation pond system shows that total nitrogen removal in a constructed wetland is better than that in an oxidation pond and the TP removal is inferior. A possible reason is the low dissolved oxygen concentration in the wetland. Constructed wetlands can restrain the growth of algae effectively, and can produce obvious ecological and economical benefits.


    • 1 January 2004
      • Vol. 16  (1) , 67-72

    Determination of operational parameters of anaerobic phase for enhanced phosphorus removal in MBR.

    by Sheng-Bing He, Bao-Zhen Wang, Lin Wang, Yi-Feng Jiang

    Two runs of experiments were carried out to obtain an understanding of phosphorus release and uptake under the anaerobic condition and then the aerobic condition respectively. Under anaerobic condition, it was found that the extent of phosphorus release appeared to increase with the increase of the initial organic loading rate when the initial organic loading rate was up to 0.1 gSCOD/gMLSS. When the initial organic loading rate was higher than 0.1 gSCOD/gMLSS, the amount of phosphorus release per unit mass of MLSS reached nearly a same stationary value, and it seemed this is not affected by organic loading rate when there is external available substrate remained. In addition, the effect of NOx-N on the phosphorus release and uptake was also investigated, it was proved that the denitrifiers has an advantage over polyphosphate accumulating bacteria in competition for organic substrate under anoxic condition. Therefore, the existence of NOx-N is disadvantageous to the phosphorus release. Based upon the above investigations, the process configuration of membrane bioreactor(MBR) in combination with anaerobic phase was proposed to enhance the removal of phosphorus in treating domestic wastewater. During the experimental period of four months, average removals of 92.50%, 84.25%, 100%, 94.09% and 85.33% were achieved for COD, TP, SS, NH3-N and TN respectively.

    • 1 November 2003
      • Vol. 15  (6) , 749-56

    Treating both wastewater and excess sludge with an innovative process.

    by Sheng-Bing He, Bao-Zhen Wang, Lin Wang, Yi-Feng Jiang

    The innovative process consists of biological unit for wastewater treatment and ozonation unit for excess sludge treatment. An aerobic membrane bioreactor (MBR) was used to remove organics and nitrogen, and an anaerobic reactor was added to the biological unit for the release of phosphorus contained at aerobic sludge to enhance the removal of phosphorus. For the excess sludge produced in the MBR, which was fed to ozone contact column and reacted with ozone, then the ozonated sludge was returned to the MBR for further biological treatment. Experimental results showed that this process could remove organics, nitrogen and phosphorus efficiently, and the removals for COD, NH3-N, TN and TP were 93.17%, 97.57%, 82.77% and 79.5%, respectively. Batch test indicated that the specific nitrification rate and specific denitrification rate of the MBR were 1.03 mg NH3-N/(gMLSS x h) and 0.56 mg NOx-N/(gMLSS x h), and denitrification seems to be the rate-limiting step. Under the test conditions, the sludge concentration in the MBR was kept at 5000-6000 mg/L, and the wasted sludge was ozonated at an ozone dosage of 0.10 kgO3/kgSS. During the experimental period of two months, no excess sludge was wasted, and a zero withdrawal of excess sludge was implemented. Through economic analysis, it was found that an additional ozonation operating cost for treatment of both wastewater and excess sludge was only 0.045 RMB Yuan (USD 0.0054)/m3 wastewater.

    • 1 September 2003
      • Vol. 15  (5) , 674-9

    A novel approach to treat combined domestic wastewater and excess sludge in MBR.

    by Sheng-Bing He, Bao-Zhen Wang, Lin Wang, Yi-Feng Jiang, Li-Qiu Zhang

    Domestic wastewater was treated by combined anaerobic biofilm-aerobic membrane bioreactor(MBR) process, and part biomass MBR was withdrawn to treat with ozone, then the ozonated sludge was returned to anaerobic inlet. In aerobic MBR, MISS and DO were controlled at 3000-3500 mg/L and 0.8 mg/L respectively. Comparing the experimental results of two stages, it was noticed that ozonation did not affect the removal efficiency for organics but had a significant influence on the removals of NH3-N and TN. During the ozonation period of two months, no excess sludge was wasted, and a zero sludge yield was obtained.

  • Performance of advanced water treatment plant for removing Fe, Mn and organic pollutants from raw water

    by Lin Wang, Baozhen Wang, Dai Wang, Weijia Zhang, Yunan Yang, Yianwu Du, Qinjin Kong

    In the case of treating a source water containing higher concentrations of Fe2+, Mn2+ and organic pollutants, the Fe2+ was partially removed by pretreatment steps of aeration-sand filtration, while Mn2+ and organics were removed mainly by an ozonation-BAC process. The performance of the advanced treatment plant and removal mechanisms are studied in this paper. The optimal O3 dosage and residual O3 were found to be 4 mg l−1 and 0.4 mg l−1, respectively, for which the Fe2+, Mn2+ and CODMn removals reached 98%, 95% and 85.5% respectively. GC/MS analytical results showed that the advanced water treatment plant was very efficient in micro-organic pollutant removal. The total species decreased from 59 in the raw water to 50, 40 and 26 in the effluents of the sand filter, ozonation column and BAC filter, respectively. The priority and potentially hazardous pollutant species decreased from 16 in the raw water to 10, 8 and 5 in the corresponding effluents, respectively.