GLGuangyuan Liu

Guangyuan Liu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Guangyuan Liu has a total of 26 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Standing-Wave Notch Filters With Improved Signal-Processing Response Considering Misalignment-Induced Harmonics in PMSM

    by Yilin Ma, Rujing Zhang, Huan Yang, Guangyuan Liu, Jie Shen

    Owing to the assembly tolerances in practical mechanical systems, the permanent-magnet synchronous machines (PMSMs) may inevitably encounter misalignment with the load shafts. As a result, harmonics at mechanical frequencies may be introduced into the signals of PMSMs, thus degrading the overall signal quality. To filter out these harmonics, notch filters (NFs) are traditionally utilized. However, existing NFs often suffer from noticeable response delays when trying to remove these mechanical harmonics at low-speed conditions. Accordingly, this article develops a standing-wave NF to reduce the response delay. It utilizes the mechanism of standing waves to linearize the temporal variations of the signals being processed. In this way, it becomes feasible to acquire the necessary linearly independent equations to calculate each component within the signals individually. As a result, the harmonics can be directly identified and eliminated, thereby accelerating the signal-processing procedure. Moreover, the Vandermonde matrix is utilized to rearrange these calculation equations, providing feasible analytical solutions even for high-order matrices and ensuring robust scalability. The accelerated dynamic performance and harmonic-removal performance of the proposed filters have been validated experimentally.


  • Online Controller Tuning for DC Microgrid Power Converters With the Ability to Track Maximum Allowable Bandwidth

    by Aram Khodamoradi, Guangyuan Liu, Paolo Mattavelli

    Possible dynamic interactions among multiple dc microgrid power converters that are connected to a common dc bus can lead to performance degradation or even stability issues in some control loops. Thus, in order to maintain a desired dynamic behavior when operating conditions or system parameters are changing, an interesting approach is to adopt autotuning for the controller parameters. In general, existing autotuning methods are based on the evaluation of the stability specifications (e.g., the crossover frequency and the phase margin) and the adaptation of the controller to ensure the specified dynamic properties. However, the desired bandwidth and phase margin may not be achievable due to parameter changes, unexpected additional delays, or unmodeled dynamics in the feedback loop. This article addresses the infeasibility issue by adding an external control loop on top of the autotuning unit. This external loop adjusts the reference crossover frequency until the phase margin specification is fulfilled. As a result, the proposed scheme is capable of tracking the highest bandwidth at which the reference phase margin is achievable, i.e., the maximum allowable bandwidth. The proposed method is applied to a dc microgrid prototype, and the simulation and experimental results are discussed.


  • Simultaneous Identification of Multiple Control Loops in DC Microgrid Power Converters

    by Aram Khodamoradi, Guangyuan Liu, Paolo Mattavelli, Tuomas Messo

    Power electronic converters used in a dc microgrid environment are usually equipped with several control loops. When many converters are connected to a common dc bus, the performance of some loops can be different from the behavior designed for the stand-alone converter, depending on the number, topology, and control of the interconnected converters. In order to establish the performance of each loop in real-time, it is important to continuously monitor the loop gains. This article presents the application of an online identification technique in rapid and simultaneous measurement of several control loops in dc microgrid power converters. To this end, multiple orthogonal pseudorandom binary sequences (PRBSs) are simultaneously injected into different loops of power converters. Since the frequency components excited by each PRBS are unique and different from any other, multiple PRBSs can be injected at the same time. This will allow to measure all the loop gains in only one measurement cycle. Hence, the operating condition of the system is kept unchanged during the measurement, which is an important factor to achieve accurate monitoring. The online identification method is applied to an experimental dc microgrid prototype, composed of three droop-controlled converters. After identifying different control loops, an adaptive tuning algorithm is implemented to adjust the digital compensator of each loop, in order to reach the desired dynamic performance. The reported experimental results confirm the accuracy and the applicability of this technique.


  • Resistive–Capacitive Output Impedance Shaping for Droop-Controlled Converters in DC Microgrids With Reduced Output Capacitance

    by Guangyuan Liu, Paolo Mattavelli, Stefano Saggini

    In dc microgrids, droop control is widely employed in power converters interfacing distributed energy resources and common dc bus for automatic power sharing. In order to limit the dc bus voltage variations even during the load transient conditions, it is necessary to shape the output impedance of droop-controlled converters to be always lower than the dc resistive value. A commonly used way is to install bulky output capacitance, which not only increases the system cost, size and weight, but also generates higher short-circuit fault currents. In order to avoid large output capacitance, this paper proposes a design approach for droop-controlled converters, including the selection criterion of the output capacitance and the design of the droop coefficient. Herein, the required output capacitance is calculated based on the dc droop coefficient and the voltage control bandwidth. The droop coefficient is designed as a frequency-dependent term instead of a constant value. As a result, the desired output impedance can be obtained with a much smaller output capacitance. The proposed design strategy is applied to buck and boost converters and validated by experimental results performed on a buck-based and a boost-based dc microgrid prototype, respectively.


  • Suppression of Second-Order Harmonic Current for Droop-Controlled Distributed Energy Resource Converters in DC Microgrids

    by Guangyuan Liu, Tommaso Caldognetto, Paolo Mattavelli, Paolo Magnone

    Droop-controlled distributed energy resource converters in dc microgrids usually show low output impedances. When coupled with ac systems, second-order harmonics typically appear on the dc-bus voltage, causing significant harmonic currents at the converters resource side. In this paper, we show how to reduce such undesired currents by means of notch filters and resonant regulators included in the converters control loops. The main characteristics of these techniques in terms of harmonic attenuation and stability are systematically investigated. In particular, it is shown that the voltage control-loop bandwidth is limited to be below twice the line frequency to avoid instability. Then, a modified notch filter and a modified resonant regulator are proposed, allowing to remove the constraint on the voltage loop bandwidth. The resulting methods (i.e., the notch filter, the resonant regulator, and their corresponding modified versions) are evaluated in terms of output impedance and stability. Experimental results from a dc microgrid prototype composed of three dc-dc converters and one dc-ac converter, all with a rated power of 5 kW, are reported.


  • Open Access

    Experimental Research on the Conveyance Capacity of a Sluice Project

    by Minzhe Zhou, Tongchun Li, Yuan Ding, Guangyuan Liu, Jinlei Jiang

    This paper focuses on the diversion and drainage capacity of a sluice project. In order to study its performance in all operating conditions, we produced a scaled physical model for testing according to related specifications. This test mainly studied the flow, flow pattern and other issues of the sluice under different water level conditions. Through observations and measurements, we obtained a relationship table of water level and flow and found out conditions that should be avoided in actual project. Furthermore, we calculated and analyzed the measured data, and then plotted the relationship figures between the flow coefficient and submergence. These results provide an effective reference for the safe and rational operation of this project.

  • Open Access

    Test Study on Influence of a Sluice on Navigation of Ships

    by Minzhe Zhou, Tongchun Li, Jinlei Jiang, Yuan Ding, Guangyuan Liu

    The navigation influenced by extension project of a sluice was researched in this paper. This sluice connected the inland river and outer river, and the hydraulic characteristics beside it were significant for ships' passages. The test in this paper was conducted for simulating the flow patterns and hydraulic characteristics around this sluice. According to the test results, the flow velocities and flow patterns around approach channels of the inland river and the outer river in various conditions are given in this paper, including the maximum lateral flow velocity and the maximum reserved flow velocity. These data provided scientific bases for safe operation of the sluice and navigation channels. In addition, a guide wall was proposed to effectively reduce the lateral flow velocity.

  • Analysis of an Online Stability Monitoring Approach for DC Microgrid Power Converters

    by Aram Khodamoradi, Guangyuan Liu, Paolo Mattavelli, Tommaso Caldognetto, Paolo Magnone

    An on-line approach to evaluate and monitor the stability margins of dc microgrid power converters is presented in this paper. The discussed online stability monitoring technique (MT) is based on the Middlebrook's loop-gain measurement technique, adapted to the digitally controlled power converters. In this approach, a perturbation is injected into a specific digital control loop of the converter and after measuring the loop gain, its crossover frequency and phase margin are continuously evaluated and monitored. The complete analytical derivation of the model, as well as detailed design aspects, are reported. In addition, the presence of multiple power converters connected to the same dc bus, all having the stability monitoring unit, is also investigated. An experimental microgrid prototype is implemented and considered to validate the theoretical analysis and simulation results, and to evaluate the effectiveness of the digital implementation of the technique for different control loops. The obtained results confirm the expected performance of the stability monitoring tool in steady-state and transient operating conditions. The proposed method can be extended to generic control loops in power converters operating in dc microgrids.