Mohammad Nizam
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Mohammad Nizam has a total of 85 co-authors. Here are the top co-authors by number of shared publications:
B. Satyanarayana
Tata Institute of Fundamental Research
3 shared publications- Hartmut F. -W. Sadrozinski
University of California Santa Cruz
2 shared publications - Jennifer Ott
University of Hawai'i Manoa
2 shared publications R. R. Shinde
Tata Institute of Fundamental Research
2 shared publications- Sankagiri Uma Sankar
Indian Institute of Technology Bombay
2 shared publications - Simone Michele Mazza
University of California Santa Cruz
2 shared publications
Latest Publications
- 1 September 2024
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 19 (09) , P09018
Real-time study of radiation damage in monocrystalline diamond sensors
Being an excellent radiation hard material, diamond is preferred as an ionizing radiation sensor in radiation harsh environments. In this study, radiation damage from a beam of 67.5 MeV protons at the Crocker Nuclear Laboratory on the campus of the University of California, Davis, was used to determine exposure lifetime in detectors made from a thinned (∼ 40 μm) monocrystalline CVD (chemical vapor deposition) diamond substrate. The sensor response was sampled in real time as the sensor was exposed to a total fluence of ∼ 4×1016 / cm2, yielding an overall damage constant of k = (3.3 ± 0.3) × 10-18 cm2 / p-μm. Damage levels were later confirmed using a non-destructive x-ray technique at the LINAC Coherent Light Source (LCLS) at the SLAC National Accelerator Laboratory. Results are presented on the real-time degradation of the charge collection efficiency as a function of proton fluence.
- 1 September 2024
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 19 (09) , P09018
Real-time study of radiation damage in monocrystalline diamond sensors
Being an excellent radiation hard material, diamond is preferred as an ionizing radiation sensor in radiation harsh environments. In this study, radiation damage from a beam of 67.5 MeV protons at the Crocker Nuclear Laboratory on the campus of the University of California, Davis, was used to determine exposure lifetime in detectors made from a thinned (∼ 40 μm) monocrystalline CVD (chemical vapor deposition) diamond substrate. The sensor response was sampled in real time as the sensor was exposed to a total fluence of ∼ 4×1016 / cm2, yielding an overall damage constant of k = (3.3 ± 0.3) × 10-18 cm2 / p-μm. Damage levels were later confirmed using a non-destructive x-ray technique at the LINAC Coherent Light Source (LCLS) at the SLAC National Accelerator Laboratory. Results are presented on the real-time degradation of the charge collection efficiency as a function of proton fluence.
- Open Access
- 25 April 2022
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 29 (3) , 595-601
Use of diamond sensors for a high-flux, high-rate X-ray pass-through diagnostic
X-ray free-electron lasers (XFELs) deliver pulses of coherent X-rays on the femtosecond time scale, with potentially high repetition rates. While XFELs provide high peak intensities, both the intensity and the centroid of the beam fluctuate strongly on a pulse-to-pulse basis, motivating high-rate beam diagnostics that operate over a large dynamic range. The fast drift velocity, low X-ray absorption and high radiation tolerance properties of chemical vapour deposition diamonds make these crystals a promising candidate material for developing a fast (multi-GHz) pass-through diagnostic for the next generation of XFELs. A new approach to the design of a diamond sensor signal path is presented, along with associated characterization studies performed in the XPP endstation of the LINAC Coherent Light Source (LCLS) at SLAC. Qualitative charge collection profiles (collected charge versus time) are presented and compared with those from a commercially available detector. Quantitative results on the charge collection efficiency and signal collection times are presented over a range of approximately four orders of magnitude in the generated electron–hole plasma density.
- 25 April 2022
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 29 (3) , 595-601
Open AccessUse of diamond sensors for a high-flux, high-rate X-ray pass-through diagnostic
X-ray free-electron lasers (XFELs) deliver pulses of coherent X-rays on the femtosecond time scale, with potentially high repetition rates. While XFELs provide high peak intensities, both the intensity and the centroid of the beam fluctuate strongly on a pulse-to-pulse basis, motivating high-rate beam diagnostics that operate over a large dynamic range. The fast drift velocity, low X-ray absorption and high radiation tolerance properties of chemical vapour deposition diamonds make these crystals a promising candidate material for developing a fast (multi-GHz) pass-through diagnostic for the next generation of XFELs. A new approach to the design of a diamond sensor signal path is presented, along with associated characterization studies performed in the XPP endstation of the LINAC Coherent Light Source (LCLS) at SLAC. Qualitative charge collection profiles (collected charge versus time) are presented and compared with those from a commercially available detector. Quantitative results on the charge collection efficiency and signal collection times are presented over a range of approximately four orders of magnitude in the generated electron–hole plasma density.
- 19 May 2021
- Published by Springer Nature
- p. 1125-1128
Study of Multi-gap Resistive Plate Chambers (MRPCs) as a Potential Candidate for Development of a PET Device
- 19 May 2021
- Published by Springer Nature
- p. 1125-1128
Study of Multi-gap Resistive Plate Chambers (MRPCs) as a Potential Candidate for Development of a PET Device
- Open Access
- 1 December 2020
- Published by Elsevier in Nuclear Physics B
- Vol. 961
Matter vs vacuum oscillations in atmospheric neutrinos
- 1 December 2020
- Published by Elsevier in Nuclear Physics B
- Vol. 961
Open AccessMatter vs vacuum oscillations in atmospheric neutrinos
- Open Access
Tensions between the appearance data of T2K and NOvA
The long baseline neutrino experiments, T2K and NOvA, have taken significant amount of data in each of the four channels: (a) $\nu_\mu$ disappearance, (b) $\bar\nu_\mu$ disappearance (c) $\nu_e$ appearance and (d) $\bar\nu_e$ appearance. There is a mild tension between the disappearance and the appearance data sets of T2K. A more serious tension exists between the $\nu_e$ appearance data of T2K and the $\nu_e / \bar\nu_e$ appearance data of NOvA. This tension is significant enough that T2K rules out the best-fit point of NOvA at $95\%$ confidence level whereas NOvA rules out T2K best-fit point at $90\%$ confidence level. We explain the reason why these tensions arise. We also do a combined fit of T2K and NOvA data and comment on the results of this fit.Open AccessTensions between the appearance data of T2K and NOvA
The long baseline neutrino experiments, T2K and NOvA, have taken significant amount of data in each of the four channels: (a) $\nu_\mu$ disappearance, (b) $\bar\nu_\mu$ disappearance (c) $\nu_e$ appearance and (d) $\bar\nu_e$ appearance. There is a mild tension between the disappearance and the appearance data sets of T2K. A more serious tension exists between the $\nu_e$ appearance data of T2K and the $\nu_e / \bar\nu_e$ appearance data of NOvA. This tension is significant enough that T2K rules out the best-fit point of NOvA at $95\%$ confidence level whereas NOvA rules out T2K best-fit point at $90\%$ confidence level. We explain the reason why these tensions arise. We also do a combined fit of T2K and NOvA data and comment on the results of this fit. - 1 September 2019
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 14 (09) , C09010
Feasibility study for Time Of Flight PET imaging based on six gap MRPC
The Multigap Resistive Plate Chambers (MRPCs) provide excellent timing as well as position resolutions at relatively low cost. Therefore, they can be used in medical imaging applications such as PET where precise timing is a crucial parameter of measurement. We have designed and fabricated several six-gap glass MRPCs and extensively studied their performance. In this paper, we describe the detector, the electronics and the data acquisition system of the setup. We present here the data analysis procedure and initial results of our studies to measure the absolute position of a radioactive source (22Na) using Time Of Flight (TOF) as well as the hit coordinate information and hence to demonstrate their potential applications in medical imaging. We also present the geant4 based simulation results on the efficiency of our detector as a function of the number of gaps and converter material thickness.
- 1 September 2019
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 14 (09) , C09010
Feasibility study for Time Of Flight PET imaging based on six gap MRPC
The Multigap Resistive Plate Chambers (MRPCs) provide excellent timing as well as position resolutions at relatively low cost. Therefore, they can be used in medical imaging applications such as PET where precise timing is a crucial parameter of measurement. We have designed and fabricated several six-gap glass MRPCs and extensively studied their performance. In this paper, we describe the detector, the electronics and the data acquisition system of the setup. We present here the data analysis procedure and initial results of our studies to measure the absolute position of a radioactive source (22Na) using Time Of Flight (TOF) as well as the hit coordinate information and hence to demonstrate their potential applications in medical imaging. We also present the geant4 based simulation results on the efficiency of our detector as a function of the number of gaps and converter material thickness.
- Open Access
Hadron energy estimation from Atmospheric neutrino events
The ICAL at INO is designed to mainly observe the muons produced in the charged current interactions of atmospheric muon neutrinos and anti-neutrinos. The track of the muon is reconstructed using the hits they produce in the detector. From this track, the charge, the energy and the direction of the muon are estimated, which are used to do oscillation physics analysis. In a large fraction of events, a number of hadrons are also produced in addition to the muons. The charged hadrons also leave hits in the detector which can be utilized to estimate the hadron energy. In this work, we study the relation between hadron hits, defined to be the difference between the total number of hits and the muon track hits, and the hadron energy. We find that a non-negligible number of baryons are produced in atmospheric neutrino interactions. For E(had) < 5 GeV, almost all the hadron energy is carried by these baryons. Finally, we formulate a procedure by which the hadron energy can be estimated from the number of hadron hits.
Open AccessHadron energy estimation from Atmospheric neutrino events
The ICAL at INO is designed to mainly observe the muons produced in the charged current interactions of atmospheric muon neutrinos and anti-neutrinos. The track of the muon is reconstructed using the hits they produce in the detector. From this track, the charge, the energy and the direction of the muon are estimated, which are used to do oscillation physics analysis. In a large fraction of events, a number of hadrons are also produced in addition to the muons. The charged hadrons also leave hits in the detector which can be utilized to estimate the hadron energy. In this work, we study the relation between hadron hits, defined to be the difference between the total number of hits and the muon track hits, and the hadron energy. We find that a non-negligible number of baryons are produced in atmospheric neutrino interactions. For E(had) < 5 GeV, almost all the hadron energy is carried by these baryons. Finally, we formulate a procedure by which the hadron energy can be estimated from the number of hadron hits.
- 24 May 2018
- Published by Springer Nature
- p. 567-569
Feasibility Study for Development of a PET Device Based on Multigap Resistive Plate Chambers
- 24 May 2018
- Published by Springer Nature
- p. 567-569
Feasibility Study for Development of a PET Device Based on Multigap Resistive Plate Chambers