Florian Geiger
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Florian Geiger has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Manfred Bischoff
Institute for Structural Mechanics University of Stuttgart Stuttgart Germany
3 shared publications - Oliver Sawodny
Institute for System Dynamics, University of Stuttgart, Stuttgart, Germany
2 shared publications - Christian Kelleter
Institute for Lightweight Structures and Conceptual Design—ILEK, University of Stuttgart, Stuttgart, Germany
1 shared publication - Clemens Honold
Institute for Engineering Design and Industrial Design (IKTD), University of Stuttgart, Pfaffenwaldring 9, 70563 Stuttgart, Germany
1 shared publication - Hansgeorg Binz
Institute for Engineering Design and Industrial Design (IKTD), University of Stuttgart, Pfaffenwaldring 9, 70569 Stuttgart, Germany
1 shared publication Jan Gade
Institute for Structural Mechanics, University of Stuttgart, Stuttgart, Germany
1 shared publication
Latest Publications
- 5 January 2024
- Published by Springer Nature
- p. 62-74
Derivation of Geometrically Parameterized Shell Elements in the Context of Shape Optimization
- 5 January 2024
- Published by Springer Nature
- p. 62-74
Derivation of Geometrically Parameterized Shell Elements in the Context of Shape Optimization
- Open Access
- 30 July 2020
- Published by Frontiers Media SA in Frontiers in Built Environment
- Vol. 6
A Case Study on Design and Optimization of Adaptive Civil Structures
Taking advantage of adaptivity in the field of civil engineering is subject to ongoing research. Integration of adaptive elements in the load bearing structure is already well established in many other engineering fields, albeit mostly for different purposes than withstanding predominantly static loads. First investigations promise substantial material and energy saving potentials also in the field of civil engineering, especially considering high-rise buildings or wide span structures, like roofs or bridges. Adaptive civil structures offer new potentials to tackle current challenges emanating from emission problems and shortage of materials. Therefore, we compare the possible minimum weight designs for different actuator placement approaches and for different structural topologies, fulfilling different constraints for high-rise buildings. We focus on case studies of illustrative examples to show, which advantages and disadvantages can be expected from a specific design. The overarching aim is to learn how truss and beam structures should be designed to exhibit good performance as an adaptive structure.
- 30 July 2020
- Published by Frontiers Media SA in Frontiers in Built Environment
- Vol. 6
Open AccessA Case Study on Design and Optimization of Adaptive Civil Structures
Taking advantage of adaptivity in the field of civil engineering is subject to ongoing research. Integration of adaptive elements in the load bearing structure is already well established in many other engineering fields, albeit mostly for different purposes than withstanding predominantly static loads. First investigations promise substantial material and energy saving potentials also in the field of civil engineering, especially considering high-rise buildings or wide span structures, like roofs or bridges. Adaptive civil structures offer new potentials to tackle current challenges emanating from emission problems and shortage of materials. Therefore, we compare the possible minimum weight designs for different actuator placement approaches and for different structural topologies, fulfilling different constraints for high-rise buildings. We focus on case studies of illustrative examples to show, which advantages and disadvantages can be expected from a specific design. The overarching aim is to learn how truss and beam structures should be designed to exhibit good performance as an adaptive structure.
- 1 August 2018
- Published by Walter de Gruyter GmbH in at - Automatisierungstechnik
- Vol. 66 (8) , 591-603
On steady-state disturbance compensability for actuator placement in adaptive structures
Adaptive structures in civil engineering are mechanical structures with the ability to modify their response to external loads. Actuators strongly affect a structure’s adaptivity and have to be placed thoughtfully in the design process to effectively compensate external loads. For constant loads, this property is introduced as steady-state disturbance compensability. This property can be linked to concepts from structural engineering such as redundancy or statical indeterminacy, thus representing an interdisciplinary approach. Based on the disturbance compensability matrix, a scalar performance metric is derived as quantitative measure of a structure’s ability to compensate the output error for arbitrary constant disturbances with a given set of actuators. By minimizing this metric, an actuator configuration is determined. The concept is applied to an example of a truss structure.
- 1 August 2018
- Published by Walter de Gruyter GmbH in at - Automatisierungstechnik
- Vol. 66 (8) , 591-603
On steady-state disturbance compensability for actuator placement in adaptive structures
Adaptive structures in civil engineering are mechanical structures with the ability to modify their response to external loads. Actuators strongly affect a structure’s adaptivity and have to be placed thoughtfully in the design process to effectively compensate external loads. For constant loads, this property is introduced as steady-state disturbance compensability. This property can be linked to concepts from structural engineering such as redundancy or statical indeterminacy, thus representing an interdisciplinary approach. Based on the disturbance compensability matrix, a scalar performance metric is derived as quantitative measure of a structure’s ability to compensate the output error for arbitrary constant disturbances with a given set of actuators. By minimizing this metric, an actuator configuration is determined. The concept is applied to an example of a truss structure.
- 16 May 2018
- Published by Wiley in Steel Construction
- Vol. 11 (2) , 109-117
The implementation of adaptive elements into an experimental high‐rise building
Dedicated to our speaker, Prof. Werner Sobek, in honour of his 65th birthdayIn 2017, the University of Stuttgart started a Collaborative Research Centre with the title Adaptive Skins and Structures for the Built Environment of Tomorrow. The goal of this research project is to find an answer to today's most urgent social and ecological questions as the global population continuously increases and the available resources remain limited. As the central approach to the solution of this problem, adaptive elements will be included in the structure, the interior and the façade of an experimental 37 m tall building. This paper introduces the topic of adaptivity in building structures and provides an overview of the research topics applied in this globally unique adaptive high‐rise building. Due to the complexity of research topics of this Collaborative Research Centre, this paper only covers the research concerning the experimental high‐rise building.
- 16 May 2018
- Published by Wiley in Steel Construction
- Vol. 11 (2) , 109-117
The implementation of adaptive elements into an experimental high‐rise building
Dedicated to our speaker, Prof. Werner Sobek, in honour of his 65th birthdayIn 2017, the University of Stuttgart started a Collaborative Research Centre with the title Adaptive Skins and Structures for the Built Environment of Tomorrow. The goal of this research project is to find an answer to today's most urgent social and ecological questions as the global population continuously increases and the available resources remain limited. As the central approach to the solution of this problem, adaptive elements will be included in the structure, the interior and the façade of an experimental 37 m tall building. This paper introduces the topic of adaptivity in building structures and provides an overview of the research topics applied in this globally unique adaptive high‐rise building. Due to the complexity of research topics of this Collaborative Research Centre, this paper only covers the research concerning the experimental high‐rise building.