Antoine R. Miniussi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Antoine R. Miniussi has a total of 82 co-authors. Here are the top co-authors by number of shared publications:
James A. Chervenak
National Aeronautics and Space Administration, Greenbelt, MD, USA
8 shared publicationsJoseph S. Adams
National Aeronautics and Space Administration, Greenbelt, MD, USA
8 shared publicationsRichard L. Kelley
National Aeronautics and Space Administration, Greenbelt, MD, USA
8 shared publicationsSimon R. Bandler
National Aeronautics and Space Administration, Greenbelt, MD, USA
8 shared publicationsFrederick S. Porter
National Aeronautics and Space Administration, Greenbelt, MD, USA
7 shared publicationsJohn E. Sadleir
National Aeronautics and Space Administration, Goddard Space Flight Center, Greenbelt, MD, USA
7 shared publications
Latest Publications
- 11 March 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 31 (5) , 1-5
Mitigation of Finite Bandwidth Effects in Time-Division-Multiplexed SQUID Readout of TES Arrays
Time division multiplexing (TDM) is being developed as the readout technology of the X-ray integral field unit (X-IFU), a 3,168-pixel X-ray transition-edge sensor (TES) imaging spectrometer that is part of the European Space Agency's Athena satellite mission. Recent improvements in the low X-ray event count rate performance of TDM have been driven by increases in multiplexer bandwidth and the mitigation of settling transients. These methods and design changes have improved the 32-row multiplexed resolution of a NASA LPA 2.5a array from an initial (2.73 ± 0.03) eV to (1.97 ± 0.01) eV resolution at 5.9 keV. We discuss these recent advances in TDM readout, which have been implemented in an 8-column × 32-row spectrometer that will be deployed at the Lawrence Livermore National Laboratory electron beam ion trap (EBIT) facility, and present a model that will inform the design of future systems.
- 11 March 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 31 (5) , 1-5
Mitigation of Finite Bandwidth Effects in Time-Division-Multiplexed SQUID Readout of TES Arrays
Time division multiplexing (TDM) is being developed as the readout technology of the X-ray integral field unit (X-IFU), a 3,168-pixel X-ray transition-edge sensor (TES) imaging spectrometer that is part of the European Space Agency's Athena satellite mission. Recent improvements in the low X-ray event count rate performance of TDM have been driven by increases in multiplexer bandwidth and the mitigation of settling transients. These methods and design changes have improved the 32-row multiplexed resolution of a NASA LPA 2.5a array from an initial (2.73 ± 0.03) eV to (1.97 ± 0.01) eV resolution at 5.9 keV. We discuss these recent advances in TDM readout, which have been implemented in an 8-column × 32-row spectrometer that will be deployed at the Lawrence Livermore National Laboratory electron beam ion trap (EBIT) facility, and present a model that will inform the design of future systems.
- 24 February 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 31 (5) , 1-6
Performance of a Broad-Band, High-Resolution, Transition-Edge Sensor Spectrometer for X-ray Astrophysics
Future X-ray astrophysics experiments require multiplexed readout of high fill-factor, kilo-pixel arrays of transition-edge sensors (TESs), with very high spectral resolution over a broad range of energies. In this paper we report on a prototype kilo-pixel array of Mo/Au TESs readout with 8-column by 32-row time-division multiplexing (TDM). This system is being used to demonstrate the critical detector and readout technology for ESA's Athena X-IFU, and when complete will be used in laboratory astrophysics experiments. Our array and TDM readout have demonstrated a combined full-width-at-half-maximum energy resolution, including > 200 pixels, of: 1.95 eV for Ti-Kα (4.5 keV), 1.97 eV for Mn-Kα (5.9 keV), 2.16 eV for Co-Kα (6.9 keV), 2.33 eV for Cu-Kα (8 keV), 3.26 eV for Br-Kα (11.9 keV). The 1 sigma statistical errors are ≤0.01 eV for all spectra. These results meet the broad-band resolution requirements for X-IFU with margin.
- 24 February 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 31 (5) , 1-6
Performance of a Broad-Band, High-Resolution, Transition-Edge Sensor Spectrometer for X-ray Astrophysics
Future X-ray astrophysics experiments require multiplexed readout of high fill-factor, kilo-pixel arrays of transition-edge sensors (TESs), with very high spectral resolution over a broad range of energies. In this paper we report on a prototype kilo-pixel array of Mo/Au TESs readout with 8-column by 32-row time-division multiplexing (TDM). This system is being used to demonstrate the critical detector and readout technology for ESA's Athena X-IFU, and when complete will be used in laboratory astrophysics experiments. Our array and TDM readout have demonstrated a combined full-width-at-half-maximum energy resolution, including > 200 pixels, of: 1.95 eV for Ti-Kα (4.5 keV), 1.97 eV for Mn-Kα (5.9 keV), 2.16 eV for Co-Kα (6.9 keV), 2.33 eV for Cu-Kα (8 keV), 3.26 eV for Br-Kα (11.9 keV). The 1 sigma statistical errors are ≤0.01 eV for all spectra. These results meet the broad-band resolution requirements for X-IFU with margin.
- 13 February 2020
- Published by Springer Nature in Journal of Low Temperature Physics
- Vol. 199 (1-2) , 45-55
Thermal Impact of Cosmic Ray Interaction with an X-Ray Microcalorimeter Array
- 13 February 2020
- Published by Springer Nature in Journal of Low Temperature Physics
- Vol. 199 (1-2) , 45-55
Thermal Impact of Cosmic Ray Interaction with an X-Ray Microcalorimeter Array
- 18 January 2020
- Published by Springer Nature in Journal of Low Temperature Physics
- Vol. 199 (3-4) , 663-671
Thermal Crosstalk Measurements and Simulations for an X-ray Microcalorimeter Array
- 18 January 2020
- Published by Springer Nature in Journal of Low Temperature Physics
- Vol. 199 (3-4) , 663-671
Thermal Crosstalk Measurements and Simulations for an X-ray Microcalorimeter Array
- Open Access
- 23 April 2019
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 125 (16) , 164503
Thermal fluctuation noise in Mo/Au superconducting transition-edge sensor microcalorimeters
In many superconducting transition-edge sensor (TES) microcalorimeters, the measured electrical noise exceeds theoretical estimates based on a thermal model of a single body thermally connected to a heat bath. Here, we report on noise and complex impedance measurements of a range of designs of TESs made with a Mo/Au bilayer. We have fitted the measured data using a two-body model, where the x-ray absorber and the TES are connected by an internal thermal conductance Gae. We find that the so-called excess noise measured in these devices is consistent with the noise generated from the internal thermal fluctuations between the x-ray absorber and the TES. Our fitted parameters are consistent with the origin of Gae being from the finite thermal conductance of the TES itself. These results suggest that even in these relatively low resistance Mo/Au TESs, the internal thermal conductance of the TES may add significant additional noise and could account for all the measured excess noise. Furthermore, we find that around regions of the superconducting transition with rapidly changing derivative of resistance with respect to temperature, an additional noise mechanism may dominate. These observations may lead to a greater understanding of TES devices and allow the design of TES microcalorimeters with improved performance.
- 23 April 2019
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 125 (16) , 164503
Open AccessThermal fluctuation noise in Mo/Au superconducting transition-edge sensor microcalorimeters
In many superconducting transition-edge sensor (TES) microcalorimeters, the measured electrical noise exceeds theoretical estimates based on a thermal model of a single body thermally connected to a heat bath. Here, we report on noise and complex impedance measurements of a range of designs of TESs made with a Mo/Au bilayer. We have fitted the measured data using a two-body model, where the x-ray absorber and the TES are connected by an internal thermal conductance Gae. We find that the so-called excess noise measured in these devices is consistent with the noise generated from the internal thermal fluctuations between the x-ray absorber and the TES. Our fitted parameters are consistent with the origin of Gae being from the finite thermal conductance of the TES itself. These results suggest that even in these relatively low resistance Mo/Au TESs, the internal thermal conductance of the TES may add significant additional noise and could account for all the measured excess noise. Furthermore, we find that around regions of the superconducting transition with rapidly changing derivative of resistance with respect to temperature, an additional noise mechanism may dominate. These observations may lead to a greater understanding of TES devices and allow the design of TES microcalorimeters with improved performance.
- Open Access
- 8 April 2019
- Published by SPIE-Intl Soc Optical Eng in Journal of Astronomical Telescopes, Instruments, and Systems
- Vol. 5 (02) , 021008-11
Multiabsorber transition-edge sensors for x-ray astronomy
Transition-edge sensors (TESs) are sensitive microcalorimeters under the development for a variety of applications in photon and particle spectroscopy.1,2 These devices consist of a thin superconducting film that is electrically biased in the highly temperature sensitive superconducting-to-normal transition region. Absorption of photon or particle energy causes a change in resistance of the sensor, which is measured as a current change by a superconducting quantum interference device (SQUID) ammeter. We are currently pursuing large format TES arrays3,4 to meet the requirements of proposed future x-ray astronomy missions.5,6 These applications require high fill-factor, kilo-pixel arrays capable of achieving full-width-half maximum (FWHM) energy resolution, , of typically a few electron volts in the energy range 0.3 to 10 keV. The maximum number of pixels used in TES arrays is constrained by a number of practical challenges. Position-sensitive microcalorimeters are an alternative approach that provides a means to increase the number of pixels within an array, at some compromise in performance, without the commensurate increase in the number of readout components, wires, and electrical connections. Although position-sensitive microcalorimeters have been investigated in a variety of different forms,7 8. 9. 10. – 11 our recent focus has been on the use of multiabsorber TESs commonly referred to as “hydras.”12,13 These devices consist of a series of individual x-ray absorbers with a different thermal conductance or “link” to a single TES. Each of these links acts as a thermal low-pass filter that gives rise to a different characteristic pulse shape for an x-ray absorbed in each pixel of the hydra. Thus these detectors can be used to provide larger focal plane coverage, or improved angular resolution for the same coverage, at some expense of performance (energy resolution and counting-rate) when compared to arrays of independent pixels. This type of detector has been proposed for a variety of different x-ray mission concepts over the past decade such as the international x-ray observatory (IXO).11,12 For IXO, the hydras were proposed as a way to increase the size of the focal-plane array around a core main array of single-pixel TESs and thus provide a greatly expanded instrument field-of-view (FOV) with only a limited increase in complexity. Results from prototype 4-pixel hydras have demonstrated to 6 eV at an x-ray energy of 5.9 keV for devices with a 0.25-mm absorber pitch.12,13- 8 April 2019
- Published by SPIE-Intl Soc Optical Eng in Journal of Astronomical Telescopes, Instruments, and Systems
- Vol. 5 (02) , 021008-11
Open AccessMultiabsorber transition-edge sensors for x-ray astronomy
Transition-edge sensors (TESs) are sensitive microcalorimeters under the development for a variety of applications in photon and particle spectroscopy.1,2 These devices consist of a thin superconducting film that is electrically biased in the highly temperature sensitive superconducting-to-normal transition region. Absorption of photon or particle energy causes a change in resistance of the sensor, which is measured as a current change by a superconducting quantum interference device (SQUID) ammeter. We are currently pursuing large format TES arrays3,4 to meet the requirements of proposed future x-ray astronomy missions.5,6 These applications require high fill-factor, kilo-pixel arrays capable of achieving full-width-half maximum (FWHM) energy resolution, , of typically a few electron volts in the energy range 0.3 to 10 keV. The maximum number of pixels used in TES arrays is constrained by a number of practical challenges. Position-sensitive microcalorimeters are an alternative approach that provides a means to increase the number of pixels within an array, at some compromise in performance, without the commensurate increase in the number of readout components, wires, and electrical connections. Although position-sensitive microcalorimeters have been investigated in a variety of different forms,7 8. 9. 10. – 11 our recent focus has been on the use of multiabsorber TESs commonly referred to as “hydras.”12,13 These devices consist of a series of individual x-ray absorbers with a different thermal conductance or “link” to a single TES. Each of these links acts as a thermal low-pass filter that gives rise to a different characteristic pulse shape for an x-ray absorbed in each pixel of the hydra. Thus these detectors can be used to provide larger focal plane coverage, or improved angular resolution for the same coverage, at some expense of performance (energy resolution and counting-rate) when compared to arrays of independent pixels. This type of detector has been proposed for a variety of different x-ray mission concepts over the past decade such as the international x-ray observatory (IXO).11,12 For IXO, the hydras were proposed as a way to increase the size of the focal-plane array around a core main array of single-pixel TESs and thus provide a greatly expanded instrument field-of-view (FOV) with only a limited increase in complexity. Results from prototype 4-pixel hydras have demonstrated to 6 eV at an x-ray energy of 5.9 keV for devices with a 0.25-mm absorber pitch.12,13 - 6 March 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 29 (5) , 1-5
Extended Line Spread Function of TES Microcalorimeters With Au/Bi Absorbers
Microcalorimeters have the potential to provide line shapes well-described by a single Gaussian broadening term of few-eV width. This attribute makes the detectors especially well suited for x-ray astrophysics observations; however, lowlevel non-Gaussian broadening terms are expected and must be characterized. These terms depend on the composition of the xray absorber, the detailed x-ray absorption physics, the device thermalization processes, and the incident x-ray energy. Here we present the first measurements targeted at understanding the extended line-spread function (LSF) of x-ray microcalorimeter pixels under development for the X-ray Integral Field Unit (XIFU) on the Athena X-ray Observatory. These pixels are comprised of Mo/Au transition-edge sensors (TESs) with overhanging electroplated Au/Bi absorbers. We measured the line shapes using monochromatic x-ray sources with < 1 eV width at several xray energies (0.85, 0.93, 1.25, 1.5, 5.4, and 8.0 keV) across the instrument bandpass (0.3-12 keV) and modeled the line profiles. These results are compared to the extended LSF of the Hitomi microcalorimeter pixels that used HgTe absorbers.
- 6 March 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 29 (5) , 1-5
Extended Line Spread Function of TES Microcalorimeters With Au/Bi Absorbers
Microcalorimeters have the potential to provide line shapes well-described by a single Gaussian broadening term of few-eV width. This attribute makes the detectors especially well suited for x-ray astrophysics observations; however, lowlevel non-Gaussian broadening terms are expected and must be characterized. These terms depend on the composition of the xray absorber, the detailed x-ray absorption physics, the device thermalization processes, and the incident x-ray energy. Here we present the first measurements targeted at understanding the extended line-spread function (LSF) of x-ray microcalorimeter pixels under development for the X-ray Integral Field Unit (XIFU) on the Athena X-ray Observatory. These pixels are comprised of Mo/Au transition-edge sensors (TESs) with overhanging electroplated Au/Bi absorbers. We measured the line shapes using monochromatic x-ray sources with < 1 eV width at several xray energies (0.85, 0.93, 1.25, 1.5, 5.4, and 8.0 keV) across the instrument bandpass (0.3-12 keV) and modeled the line profiles. These results are compared to the extended LSF of the Hitomi microcalorimeter pixels that used HgTe absorbers.
- 13 February 2019
- Published by Springer Nature in Journal of Low Temperature Physics
- Vol. 194 (5-6) , 433-442
Design of Magnetic Shielding and Field Coils for a TES X-ray Microcalorimeter Test Platform
- 13 February 2019
- Published by Springer Nature in Journal of Low Temperature Physics
- Vol. 194 (5-6) , 433-442
Design of Magnetic Shielding and Field Coils for a TES X-ray Microcalorimeter Test Platform
- 10 July 2018
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10699, 106991L
Transition-edge sensor array development for the ATHENA x-ray itegral field unit (Conference Presentation)
The X-ray integral field unit (X-IFU) proposed for ESA’s Athena X-ray observatory will consist of 3840 transition edge sensor (TES) microcalorimeters optimized for the energy range of 0.2 to 12 keV. The instrument will provide unprecedented spectral resolution of ~ 2.5 eV at energies of up to 7 keV and will accommodate photon fluxes of 10’s mcrab (1000’s cps). Over the past two years the baseline configuration has evolved from the original proposal. The current baseline consists of a uniform large pixel array (LPA) of 5” pixels, AC-biased within their superconducting-to-normal transition and read out using frequency domain multiplexing (FDM). The baseline pixel design is approximately a factor of two times slower than in the original concept. High count-rate accommodation, needed for bright point source observations, is now achieved by defocusing the telescope optic to spread the photons over a larger number of pixels. In this paper we report on Mo/Au TES designs that are being optimized to meet the baseline pixel parameters and performance goals. This includes detailed studies on the optimization of the thermal heat sink and the impact of different TES geometries (including TES size and normal metal feature geometries) on the DC-biased transition shape. We discuss how these geometric effects ultimately impact important performance metrics such as energy resolution, decay time, slew-rate and array scale uniformity. Our Mo/Au TESs have historically been designed and optimized for DC-biased operation, however, the primary readout technology uses an AC drive to bias the TES. Depending upon the drive frequency, the AC bias affects the TES transition shape in two ways. Firstly, due to losses from the bias current coupling to metallic components in close proximity to the TES and secondly introducing fine structure in the transition due to Josephson effects. We present latest pixel design optimizations targeted at mitigating these frequency dependent effects in order to achieve commensurate performance with that obtained in the DC case.
- 10 July 2018
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10699, 106991L
Transition-edge sensor array development for the ATHENA x-ray itegral field unit (Conference Presentation)
The X-ray integral field unit (X-IFU) proposed for ESA’s Athena X-ray observatory will consist of 3840 transition edge sensor (TES) microcalorimeters optimized for the energy range of 0.2 to 12 keV. The instrument will provide unprecedented spectral resolution of ~ 2.5 eV at energies of up to 7 keV and will accommodate photon fluxes of 10’s mcrab (1000’s cps). Over the past two years the baseline configuration has evolved from the original proposal. The current baseline consists of a uniform large pixel array (LPA) of 5” pixels, AC-biased within their superconducting-to-normal transition and read out using frequency domain multiplexing (FDM). The baseline pixel design is approximately a factor of two times slower than in the original concept. High count-rate accommodation, needed for bright point source observations, is now achieved by defocusing the telescope optic to spread the photons over a larger number of pixels. In this paper we report on Mo/Au TES designs that are being optimized to meet the baseline pixel parameters and performance goals. This includes detailed studies on the optimization of the thermal heat sink and the impact of different TES geometries (including TES size and normal metal feature geometries) on the DC-biased transition shape. We discuss how these geometric effects ultimately impact important performance metrics such as energy resolution, decay time, slew-rate and array scale uniformity. Our Mo/Au TESs have historically been designed and optimized for DC-biased operation, however, the primary readout technology uses an AC drive to bias the TES. Depending upon the drive frequency, the AC bias affects the TES transition shape in two ways. Firstly, due to losses from the bias current coupling to metallic components in close proximity to the TES and secondly introducing fine structure in the transition due to Josephson effects. We present latest pixel design optimizations targeted at mitigating these frequency dependent effects in order to achieve commensurate performance with that obtained in the DC case.
- 29 May 2018
- Published by Springer Nature in Journal of Low Temperature Physics
- Vol. 193 (3-4) , 337-343
Performance of an X-ray Microcalorimeter with a 240 μm Absorber and a 50 μm TES Bilayer
- 29 May 2018
- Published by Springer Nature in Journal of Low Temperature Physics
- Vol. 193 (3-4) , 337-343
Performance of an X-ray Microcalorimeter with a 240 μm Absorber and a 50 μm TES Bilayer