Simon Viniol
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Simon Viniol has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Alexander Marc König
Clinic of Diagnostic and Interventional Radiology, University Hospital Marburg, Philipps-University Marburg, Baldingerstrasse, 35043 Marburg, Germany
3 shared publications A.H. Mahnken
Philipps-University of Marburg, Clinic of Diagnostic and Interventional Radiology, University hospital Marburg, Germany
2 shared publications- Robin Etzel
Affiliation Institute of Medical Physics and Radiation Protection, Mittelhessen University of Applied Sciences, Giessen, Germany
2 shared publications S. Betz
Department of Emergency Medicine, Marburg University Hospital, Philipps-University, Marburg, Germany
2 shared publicationsA. H. Mahnken
Department of Diagnostic and Interventional Radiology, Marburg University Hospital, Philipps-University, Marburg, Germany
1 shared publicationA. M. König
Department of Diagnostic and Interventional Radiology, Marburg University Hospital, Philipps-University, Marburg, Germany
1 shared publication
Latest Publications
- Open Access
- 16 April 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (8) , 1179
Injury Patterns in Resuscitated Non-Traumatic Cardiac Arrest Patients—A Comparative CT Analysis Between Automated Chest Compression Devices
Objectives: The aim of this study was to determine differences in injury types and frequencies between piston-based and band-based automated chest compression devices in patients with non-traumatic out-of-hospital cardiac arrest (OHCA) at a German cardiac arrest center. Methods: This retrospective single-center study assessed resuscitation-related injuries in OHCA patients using protocol-based early whole-body CT scans at hospital admission. CT scans were reviewed independently by two reviewers blinded to the compression device used. Between May 2015 and September 2021, all patients resuscitated from non-traumatic OHCA, treated with a mechanical chest compression device, and showing stable return of spontaneous circulation (ROSC) until CT examination according to the institutional standard operating procedure for all OHCA patients were included. Patients were categorized by compression device type, and group differences were analyzed using the Chi-square test and Mann–Whitney U test. In addition, patient-level incidences of rib fracture types were calculated, and risk ratios with corresponding 95% confidence intervals were used to compare rib fracture patterns between groups. A p-value of p = 0.01) and displaced rib fractures (117 vs. 87; p = 0.046; patient-level RR = 1.43, 95% CI 1.06–1.93). Conclusions: In this observational study of a CT-based cohort of OHCA patients with stable ROSC, the band-based device was associated with significantly higher frequencies of liver lacerations and displaced rib fractures than the piston-based device. These findings should be interpreted as hypothesis-generating and may support further evaluation of device-specific injury profiles in future studies.
- 16 April 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (8) , 1179
Open AccessInjury Patterns in Resuscitated Non-Traumatic Cardiac Arrest Patients—A Comparative CT Analysis Between Automated Chest Compression Devices
Objectives: The aim of this study was to determine differences in injury types and frequencies between piston-based and band-based automated chest compression devices in patients with non-traumatic out-of-hospital cardiac arrest (OHCA) at a German cardiac arrest center. Methods: This retrospective single-center study assessed resuscitation-related injuries in OHCA patients using protocol-based early whole-body CT scans at hospital admission. CT scans were reviewed independently by two reviewers blinded to the compression device used. Between May 2015 and September 2021, all patients resuscitated from non-traumatic OHCA, treated with a mechanical chest compression device, and showing stable return of spontaneous circulation (ROSC) until CT examination according to the institutional standard operating procedure for all OHCA patients were included. Patients were categorized by compression device type, and group differences were analyzed using the Chi-square test and Mann–Whitney U test. In addition, patient-level incidences of rib fracture types were calculated, and risk ratios with corresponding 95% confidence intervals were used to compare rib fracture patterns between groups. A p-value of p = 0.01) and displaced rib fractures (117 vs. 87; p = 0.046; patient-level RR = 1.43, 95% CI 1.06–1.93). Conclusions: In this observational study of a CT-based cohort of OHCA patients with stable ROSC, the band-based device was associated with significantly higher frequencies of liver lacerations and displaced rib fractures than the piston-based device. These findings should be interpreted as hypothesis-generating and may support further evaluation of device-specific injury profiles in future studies.
- Open Access
- 21 July 2022
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 17 (7) , e0271664
Physical strain while wearing personal radiation protection systems in interventional radiology
Objectives: Multiple studies show orthopedic health problems for medical staff due to wearing radiation protection aprons. The aim of this study was to evaluate the weight pressure on the shoulder as a marker of physical strain caused by different radiation-protection devices. Methods: For the weight pressure measurement, a pressure sensor (OMD-30-SE-100N, OptoForce, Budapest, Hungary) placed on the left and right shoulder was used. Wearing different radiation protection systems the force measurement system was used to quantify the weight pressure. Measurements were acquired in still standing position and during various movements. Results: A mean significant decreasing weight pressure on the shoulder between 74% and 84% (p<0.001) was measured, when the free-hanging radiation protection system was used in comparison to one-piece and two-piece radiation protection aprons and coats. Using two-piece radiation protection aprons, the weight pressure was significantly lower than that of one-piece radiation protection coats. If a belt was used for the one-piece radiation protection coat, the weight pressure on the shoulder was reduced by 32.5% (p = 0.003). For a two-piece radiation protection apron and a one-piece radiation protection coat (with and without belt) a significant different weight pressure distribution between the right and left shoulder could be measured. Conclusions: The free-hanging radiation protection system showed a significant lower weight pressure in comparison to the other radiation protection devices. Apart from this, use of a two-piece radiation protection apron or addition of a belt to a radiation protection coat proved to be further effective options to reduce weight pressure.
- 21 July 2022
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 17 (7) , e0271664
Open AccessPhysical strain while wearing personal radiation protection systems in interventional radiology
Objectives: Multiple studies show orthopedic health problems for medical staff due to wearing radiation protection aprons. The aim of this study was to evaluate the weight pressure on the shoulder as a marker of physical strain caused by different radiation-protection devices. Methods: For the weight pressure measurement, a pressure sensor (OMD-30-SE-100N, OptoForce, Budapest, Hungary) placed on the left and right shoulder was used. Wearing different radiation protection systems the force measurement system was used to quantify the weight pressure. Measurements were acquired in still standing position and during various movements. Results: A mean significant decreasing weight pressure on the shoulder between 74% and 84% (p<0.001) was measured, when the free-hanging radiation protection system was used in comparison to one-piece and two-piece radiation protection aprons and coats. Using two-piece radiation protection aprons, the weight pressure was significantly lower than that of one-piece radiation protection coats. If a belt was used for the one-piece radiation protection coat, the weight pressure on the shoulder was reduced by 32.5% (p = 0.003). For a two-piece radiation protection apron and a one-piece radiation protection coat (with and without belt) a significant different weight pressure distribution between the right and left shoulder could be measured. Conclusions: The free-hanging radiation protection system showed a significant lower weight pressure in comparison to the other radiation protection devices. Apart from this, use of a two-piece radiation protection apron or addition of a belt to a radiation protection coat proved to be further effective options to reduce weight pressure.
- 1 November 2020
- Published by Elsevier in European Journal of Radiology
- Vol. 132, 109245
Scatter radiation reduction with a radiation-absorbing pad in interventional radiology examinations
- 1 November 2020
- Published by Elsevier in European Journal of Radiology
- Vol. 132, 109245
Scatter radiation reduction with a radiation-absorbing pad in interventional radiology examinations
- 1 October 2020
- Published by Elsevier in European Journal of Radiology
- Vol. 131, 109244
Comparison of different resuscitation methods with regard to injury patterns in cardiac arrest survivors based on computer tomography
- 1 October 2020
- Published by Elsevier in European Journal of Radiology
- Vol. 131, 109244
Comparison of different resuscitation methods with regard to injury patterns in cardiac arrest survivors based on computer tomography
- Open Access
- 11 September 2019
- Published by Georg Thieme Verlag KG in RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
- Vol. 192 (02) , 171-182
Update Regarding Imaging of Neuroendocrine Neoplasms
Background Neuroendocrine neoplasms (NEN) are a heterogeneous group of tumors characterized by the expression of typical proteins. A wide range of morphological and functional imaging methods is required in order to adequately assess the course of the disease and to optimally treat the patient. The spectrum of indications ranges from the detection of small primary tumors to the documentation of the metastasis pattern and the assessment of the suitability for certain invasive or noninvasive therapy methods. The exact recording and quantification of findings is indispensable. Methods This article is based on a comprehensive literature search on the different aspects of neuroendocrine neoplasm imaging. Results This article is intended to provide an overview of the available imaging procedures with their respective advantages and disadvantages for diagnostics and their value for the follow-up of neuroendocrine neoplasms. Recommendations for examination protocols, typical image findings, and an outlook regarding future developments are presented. Key Points: Citation Format
- 11 September 2019
- Published by Georg Thieme Verlag KG in RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
- Vol. 192 (02) , 171-182
Open AccessUpdate Regarding Imaging of Neuroendocrine Neoplasms
Background Neuroendocrine neoplasms (NEN) are a heterogeneous group of tumors characterized by the expression of typical proteins. A wide range of morphological and functional imaging methods is required in order to adequately assess the course of the disease and to optimally treat the patient. The spectrum of indications ranges from the detection of small primary tumors to the documentation of the metastasis pattern and the assessment of the suitability for certain invasive or noninvasive therapy methods. The exact recording and quantification of findings is indispensable. Methods This article is based on a comprehensive literature search on the different aspects of neuroendocrine neoplasm imaging. Results This article is intended to provide an overview of the available imaging procedures with their respective advantages and disadvantages for diagnostics and their value for the follow-up of neuroendocrine neoplasms. Recommendations for examination protocols, typical image findings, and an outlook regarding future developments are presented. Key Points: Citation Format
- 29 August 2019
- Published by Springer Nature in Emergency Radiology
- Vol. 27 (1) , 23-29
Early whole-body CT for treatment guidance in patients with return of spontaneous circulation after cardiac arrest
Non-traumatic cardiac arrest (CA) and return of spontaneous circulation (ROSC) after cardiopulmonary resuscitation (CPR) are often associated with multiple pathologies. Expecting a high prevalence of important findings, a whole-body CT (WBCT) could be of relevance for therapy. The aim of this study is to investigate the feasibility and diagnostic yield of an early WBCT in this setting.
- 29 August 2019
- Published by Springer Nature in Emergency Radiology
- Vol. 27 (1) , 23-29
Early whole-body CT for treatment guidance in patients with return of spontaneous circulation after cardiac arrest
Non-traumatic cardiac arrest (CA) and return of spontaneous circulation (ROSC) after cardiopulmonary resuscitation (CPR) are often associated with multiple pathologies. Expecting a high prevalence of important findings, a whole-body CT (WBCT) could be of relevance for therapy. The aim of this study is to investigate the feasibility and diagnostic yield of an early WBCT in this setting.
- 1 July 2017
- Published by Dustri-Verlag Dr. Karl Feistle in Intensiv- und Notfallbehandlung
- Vol. 42 (07) , 86-102
Das Röntgenbild des Thorax in der Intensivmedizin
- 1 July 2017
- Published by Dustri-Verlag Dr. Karl Feistle in Intensiv- und Notfallbehandlung
- Vol. 42 (07) , 86-102
Das Röntgenbild des Thorax in der Intensivmedizin