JKJoshua C. Kline

Joshua C. Kline

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Joshua C. Kline has a total of 35 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Validation of a Python-Based Graphical User Interface for Calculation of Relative Fundamental Frequency

    by Mara R. Kapsner-Smith, Aideen Gill, Abigail Muzila, Tamara Polyakova, Austeja Rubeski, Joshua Kline, Cara E. Stepp, Jenny Vojtech

  • Open Access

    Platform Design for Optical Screening and Conditioning for Injury Resilience

    by Bhawna Shiwani, Amy Silder, Alaina Tulskie, Dalya Al-Mfarej, Brian Green, Serge H Roy, Gianluca De Luca, Pinata H Sessoms, Joshua Kline

    Musculoskeletal injuries (MSKIs) among active duty soldiers result in more than 10 million limited duty days each year and account for more than 70% of the medically nondeployable population. Overuse injuries in lower limbs from running, foot marching long distances with heavy loads, and lifting heavy objects are the most common types of injuries in the military. Physical training and rehabilitation exercises for greater resiliency through aerobic, muscle strength, endurance, and agility conditioning programs can prevent or reduce the effects of MSKIs if Soldiers adhere to proper biomechanics and training techniques. We are introducing a three-dimensional (3D) camera-based platform for Optical Screening and Conditioning for Injury Resilience (OSCIR) that is designed to identify and correct high-risk movement patterns based on quantifiable biomechanical measurements in clinical or field settings. Our goal is to improve resilience to MSKI by offering greater access to quality of movement skills in warfighters through an autonomous device that can be used in Sports Medicine and Reconditioning Team (SMART) clinics and High-Intensity Tactical Training (HITT) sites. OSCIR fuses four pairs of Kinect Azure cameras into a concise footprint to achieve suitable sampling rates and an unobstructed field of view for accurate dynamic movement tracking using a custom point cloud solution. We designed a unique multistage 3D joint tracking algorithm architecture to methodically isolate the human body point cloud from the background, identify individual limb segments, and perform iterative joint optimization at the global and local joint levels. We evaluated the feasibility of our prototype system among N = 12 control participants (6 M/6 F; 21-37 years) in compliance with the Western Institutional Review Board (Tracking #20225920, approved on November 4, 2022). Five task-specific MSKI outcome metrics identified by end-user physical therapists and athletic trainers as indicators for movement quality were assessed across 7 lower-extremity exercises derived from standardized MSK assessment/conditioning batteries used in the military. Data were recorded concurrently by OSCIR and a reference standard Vicon motion capture system for validating system accuracy. Task-specific MSKI indicators for knee flexion and hip flexion range of motion achieved an average error of 4.05 ± 2.34°, while 3D position-based postural outcomes of left-right foot distance, left-right hand distance, and step length obtained mean absolute errors of 2.58 ± 2.30 cm. Results support the feasibility of our system in achieving outcomes that are comparable to currently accepted laboratory standards. Our study describes the integration process for a 3D camera-based clinical system for MSKI conditioning and rehabilitation. The impact of our system will enable key stakeholders in the military to manage MSKIs in warfighters by automating key assessment and rehabilitation test batteries; making tests more readily accessible, and interpretations more accurate by providing objective biomechanical measures. OSCIR is undergoing turn-key design features to serve as a screening tool for warfighters to readily assess susceptibility to MSKI or as a training platform to help guide exercise techniques to achieve resiliency against future injuries.


  • Open Access

    Prediction of Voice Fundamental Frequency and Intensity from Surface Electromyographic Signals of the Face and Neck

    by Jennifer M. Vojtech, Claire L. Mitchell, Laura Raiff, Joshua C. Kline, Gianluca De Luca

    Silent speech interfaces (SSIs) enable speech recognition and synthesis in the absence of an acoustic signal. Yet, the archetypal SSI fails to convey the expressive attributes of prosody such as pitch and loudness, leading to lexical ambiguities. The aim of this study was to determine the efficacy of using surface electromyography (sEMG) as an approach for predicting continuous acoustic estimates of prosody. Ten participants performed a series of vocal tasks including sustained vowels, phrases, and monologues while acoustic data was recorded simultaneously with sEMG activity from muscles of the face and neck. A battery of time-, frequency-, and cepstral-domain features extracted from the sEMG signals were used to train deep regression neural networks to predict fundamental frequency and intensity contours from the acoustic signals. We achieved an average accuracy of 0.01 ST and precision of 0.56 ST for the estimation of fundamental frequency, and an average accuracy of 0.21 dB SPL and precision of 3.25 dB SPL for the estimation of intensity. This work highlights the importance of using sEMG as an alternative means of detecting prosody and shows promise for improving SSIs in future development.


  • Open Access

    Ability-Based Methods for Personalized Keyboard Generation

    by Claire L. Mitchell, Gabriel J. Cler, Susan K. Fager, Paola Contessa, Serge H. Roy, Gianluca De Luca, Joshua C. Kline, Jennifer M. Vojtech

    This study introduces an ability-based method for personalized keyboard generation, wherein an individual’s own movement and human–computer interaction data are used to automatically compute a personalized virtual keyboard layout. Our approach integrates a multidirectional point-select task to characterize cursor control over time, distance, and direction. The characterization is automatically employed to develop a computationally efficient keyboard layout that prioritizes each user’s movement abilities through capturing directional constraints and preferences. We evaluated our approach in a study involving 16 participants using inertial sensing and facial electromyography as an access method, resulting in significantly increased communication rates using the personalized keyboard (52.0 bits/min) when compared to a generically optimized keyboard (47.9 bits/min). Our results demonstrate the ability to effectively characterize an individual’s movement abilities to design a personalized keyboard for improved communication. This work underscores the importance of integrating a user’s motor abilities when designing virtual interfaces.


  • Surface Electromyography–Based Recognition, Synthesis, and Perception of Prosodic Subvocal Speech

    by Jennifer M. Vojtech, Michael D. Chan, Bhawna Shiwani, Serge H. Roy, James T. Heaton, Geoffrey S. Meltzner, Paola Contessa, Gianluca De Luca, Rupal Patel, Joshua C. Kline

    Purpose: This study aimed to evaluate a novel communication system designed to translate surface electromyographic (sEMG) signals from articulatory muscles into speech using a personalized, digital voice. The system was evaluated for word recognition, prosodic classification, and listener perception of synthesized speech.Method: sEMG signals were recorded from the face and neck as speakers with (n = 4) and without (n = 4) laryngectomy subvocally recited (silently mouthed) a speech corpus comprising 750 phrases (150 phrases with variable phrase-level stress). Corpus tokens were then translated into speech via personalized voice synthesis (n = 8 synthetic voices) and compared against phrases produced by each speaker when using their typical mode of communication (n = 4 natural voices,n = 4 electrolaryngeal [EL] voices). Naïve listeners (n = 12) evaluated synthetic, natural, and EL speech for acceptability and intelligibility in a visual sort-and-rate task, as well as phrasal stress discriminability via a classification mechanism.Results: Recorded sEMG signals were processed to translate sEMG muscle activity into lexical content and categorize variations in phrase-level stress, achieving a mean accuracy of 96.3% (SD = 3.10%) and 91.2% (SD = 4.46%), respectively. Synthetic speech was significantly higher in acceptability and intelligibility than EL speech, also leading to greater phrasal stress classification accuracy, whereas natural speech was rated as the most acceptable and intelligible, with the greatest phrasal stress classification accuracy.Conclusion: This proof-of-concept study establishes the feasibility of using subvocal sEMG-based alternative communication not only for lexical recognition but also for prosodic communication in healthy individuals, as well as those living with vocal impairments and residual articulatory function.Supplemental Material: https://doi.org/10.23641/asha.14558481


  • Motor unit drive: a neural interface for real-time upper limb prosthetic control

    by Michael D Twardowski, Serge H. Roy, Zhi Li, Paola Contessa, Gianluca De Luca, Joshua C. Kline

    Objective . Modern prosthetic limbs have made strident gains in recent years, incorporating terminal electromechanical devices that are capable of mimicking the human hand. However, access to these advanced control capabilities has been prevented by fundamental limitations of amplitude-based myoelectric neural interfaces, which have remained virtually unchanged for over four decades. Consequently, nearly 23% of adults and 32% of children with major traumatic or congenital upper-limb loss abandon regular use of their myoelectric prosthesis. To address this healthcare need, we have developed a noninvasive neural interface technology that maps natural motor unit increments of neural control and force into biomechanically informed signals for improved prosthetic control. Approach . Our technology, referred to as motor unit drive (MU Drive), utilizes real-time machine learning algorithms for directly measuring motor unit firings from surface electromyographic signals recorded from residual muscles of an amputated or congenitally missing limb. The extracted firings are transformed into biomechanically informed signals based on the force generating properties of individual motor units to provide a control source that represents the intended movement. Main results . We evaluated the characteristics of the MU Drive control signals and compared them to conventional amplitude-based myoelectric signals in healthy subjects as well as subjects with congenital or traumatic trans-radial limb-loss. Our analysis established a vital proof-of-concept: MU Drive provides a more responsive real-time signal with improved smoothness and more faithful replication of intended limb movement that overcomes the trade-off between performance and latency inherent to amplitude-based myoelectric methods. Significance . MU Drive is the first neural interface for prosthetic control that provides noninvasive real-time access to the natural motor control mechanisms of the human nervous system. This new neural interface holds promise for improving prosthetic function by achieving advanced control that better reflects the user intent. Beyond the immediate advantages in the field of prosthetics, MU Drive provides an innovative alternative for advancing the control of exoskeletons, assistive devices, and other robotic rehabilitation applications.


  • Top Cited Papers

    Development of sEMG sensors and algorithms for silent speech recognition

    by Geoffrey S. Meltzner, James T. Heaton, Yunbin Deng, Gianluca De Luca, Serge H. Roy, Joshua C. Kline

    Objective . Speech is among the most natural forms of human communication, thereby offering an attractive modality for human–machine interaction through automatic speech recognition (ASR). However, the limitations of ASR—including degradation in the presence of ambient noise, limited privacy and poor accessibility for those with significant speech disorders—have motivated the need for alternative non-acoustic modalities of subvocal or silent speech recognition (SSR). Approach . We have developed a new system of face- and neck-worn sensors and signal processing algorithms that are capable of recognizing silently mouthed words and phrases entirely from the surface electromyographic (sEMG) signals recorded from muscles of the face and neck that are involved in the production of speech. The algorithms were strategically developed by evolving speech recognition models: first for recognizing isolated words by extracting speech-related features from sEMG signals, then for recognizing sequences of words from patterns of sEMG signals using grammar models, and finally for recognizing a vocabulary of previously untrained words using phoneme-based models. The final recognition algorithms were integrated with specially designed multi-point, miniaturized sensors that can be arranged in flexible geometries to record high-fidelity sEMG signal measurements from small articulator muscles of the face and neck. Main results . We tested the system of sensors and algorithms during a series of subvocal speech experiments involving more than 1200 phrases generated from a 2200-word vocabulary and achieved an 8.9%-word error rate (91.1% recognition rate), far surpassing previous attempts in the field. Significance . These results demonstrate the viability of our system as an alternative modality of communication for a multitude of applications including: persons with speech impairments following a laryngectomy; military personnel requiring hands-free covert communication; or the consumer in need of privacy while speaking on a mobile phone in public.


  • Top Cited Papers

    Silent Speech Recognition as an Alternative Communication Device for Persons With Laryngectomy

    by Geoffrey S. Meltzner, James T. Heaton, Yunbin Deng, Gianluca De Luca, Serge H. Roy, Joshua C. Kline

    Each year thousands of individuals require surgical removal of the larynx (voice box) due to trauma or disease, and thereby require an alternative voice source or assistive device to verbally communicate. Although natural voice is lost after laryngectomy, most muscles controlling speech articulation remain intact. Surface electromyographic (sEMG) activity of speech musculature can be recorded from the neck and face, and used for automatic speech recognition to provide speech-to-text or synthesized speech as an alternative means of communication. This is true even when speech is mouthed or spoken in a silent (subvocal) manner, making it an appropriate communication platform after laryngectomy. In this study, eight individuals at least 6 months after total laryngectomy were recorded using eight sEMG sensors on their face (4) and neck (4) while reading phrases constructed from a 2500-word vocabulary. A unique set of phrases were used for training phoneme-based recognition models for each of the 39 commonly used phonemes in English, and the remaining phrases were used for testing word recognition of the models based on phoneme identification from running speech. Word error rates were on average 10.3% for the full eight-sensor set (averaging 9.5% for the top four participants), and 13.6% when reducing the sensor set to four locations per individual (n = 7). This study provides a compelling proof-of-concept for sEMG-based alaryngeal speech recognition, with the strong potential to further improve recognition performance.