Chao Wang
Research Subjects
Chao Wang has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Zi Qiang Zhu
Department of Electrical and Electronic Engineering, The Hong Kong Polytechnic University, Hong Kong, China
6 shared publications - Jean-Claude Mipo
Valeo Powertrain Electric Systems, VALEO, CRETEIL, France, 94000
2 shared publications - Philippe Farah
Valeo, 2, rue Andre Boulle 94000 CRETEIL France
2 shared publications - Sophie Personnaz
Valeo Powertrain Electric Systems, VALEO, Paris Creteil Cedex France
2 shared publications Z. Z. Wu
Dept. of Electronic and Electrical Engineering, University of Sheffield, Sheffield United Kingdom of Great Britain and Northern Ireland S1 4DE
2 shared publicationsChanghong Meng
State Grid Shanxi Economic Research Institute,Taiyuan,China
1 shared publication
Latest Publications
- 30 October 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1413-1416
Analysis on the Influence of Multi Source Load Connection on Distribution Network Operation
Since the 21st century, with the increasing shortage of global primary energy reserves and the popularity of environmental problems, the global wave of renewable energy has been set off. As the cleanest secondary energy, electric energy is one of the most important measures to solve the global energy shortage and unbalanced energy distribution by using renewable energy distributed access and transforming it into power grid. The multi-source load access to the power grid is bound to have a certain impact on the distribution network. In this paper, in order to study the impact of distributed generation access on distribution network, the hybrid output model of distributed generation is established. The accuracy of the model is proved by an example, which lays a foundation for the future research on active distribution network structure adapting to multiple source load access.
- 30 October 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1413-1416
Analysis on the Influence of Multi Source Load Connection on Distribution Network Operation
Since the 21st century, with the increasing shortage of global primary energy reserves and the popularity of environmental problems, the global wave of renewable energy has been set off. As the cleanest secondary energy, electric energy is one of the most important measures to solve the global energy shortage and unbalanced energy distribution by using renewable energy distributed access and transforming it into power grid. The multi-source load access to the power grid is bound to have a certain impact on the distribution network. In this paper, in order to study the impact of distributed generation access on distribution network, the hybrid output model of distributed generation is established. The accuracy of the model is proved by an example, which lays a foundation for the future research on active distribution network structure adapting to multiple source load access.
- 1 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 35 (3) , 1628-1637
A Novel Fractional Slot Non-Overlapping Winding Hybrid Excited Machine With Consequent-Pole PM Rotor
- 1 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 35 (3) , 1628-1637
A Novel Fractional Slot Non-Overlapping Winding Hybrid Excited Machine With Consequent-Pole PM Rotor
- 20 January 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 56 (2) , 1505-1517
Fuzzy Logic Speed Control of Permanent Magnet Synchronous Machine and Feedback Voltage Ripple Reduction in Flux-Weakening Operation Region
Voltage feedback flux-weakening control has the advantages of simplicity and robustness against parameter variation. However, due to less voltage control margin in the flux-weakening region, the increased feedback voltage ripple could deteriorate the system performance in the flux-weakening region and may even cause oscillation. In this paper, based on a non-salient permanent magnet synchronous machine (PMSM), the steady-state feedback voltage ripple in the flux-weakening region are analyzed first. It shows that the feedback voltage ripple caused by the current command ripple could dominate in some flux-weakening regions. Consequently, the speed bandwidth based on the conventional speed proportional-integral (PI) controller in the flux-weakening region can be hardly increased, which leads to poor dynamic performance. In order to obtain both fast speed dynamics and less steady-state ripple, especially in the flux-weakening region, an adaptive fuzzy logic (FLC) speed controller is designed and compared with the conventional speed PI controller. With the adaptive FLC, the DC-link voltage utilization can be increased and better flux-weakening capability can be obtained. Finally, the improved performances are verified by the experimental results.
- 20 January 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 56 (2) , 1505-1517
Fuzzy Logic Speed Control of Permanent Magnet Synchronous Machine and Feedback Voltage Ripple Reduction in Flux-Weakening Operation Region
Voltage feedback flux-weakening control has the advantages of simplicity and robustness against parameter variation. However, due to less voltage control margin in the flux-weakening region, the increased feedback voltage ripple could deteriorate the system performance in the flux-weakening region and may even cause oscillation. In this paper, based on a non-salient permanent magnet synchronous machine (PMSM), the steady-state feedback voltage ripple in the flux-weakening region are analyzed first. It shows that the feedback voltage ripple caused by the current command ripple could dominate in some flux-weakening regions. Consequently, the speed bandwidth based on the conventional speed proportional-integral (PI) controller in the flux-weakening region can be hardly increased, which leads to poor dynamic performance. In order to obtain both fast speed dynamics and less steady-state ripple, especially in the flux-weakening region, an adaptive fuzzy logic (FLC) speed controller is designed and compared with the conventional speed PI controller. With the adaptive FLC, the DC-link voltage utilization can be increased and better flux-weakening capability can be obtained. Finally, the improved performances are verified by the experimental results.
- 6 December 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 56 (2) , 1529-1542
Adaptive Voltage Feedback Controllers on Nonsalient Permanent Magnet Synchronous Machine
This article investigates the nonlinear behavior of the conventional voltage feedback flux-weakening control, i.e., the voltage magnitude feedback control on the nonsalient permanent magnet synchronous machine, and proposes an adaptive control parameter tuning method for the voltage feedback controller. Due to less voltage margin in the flux-weakening region, the current dynamic performance is degraded. This issue is more serious when the system operates in the overmodulation region and could affect the system's stability. Based on the designed voltage feedback controller, the system performance in the flux-weakening and overmodulation regions is further improved by utilizing the current and voltage reference modifiers. Consequently, the system can operate well in both linear and overmodulation regions with the specified scaling factor, which is beneficial to general-purpose applications. The viability of the proposed method is demonstrated by the experimental results.
- 6 December 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 56 (2) , 1529-1542
Adaptive Voltage Feedback Controllers on Nonsalient Permanent Magnet Synchronous Machine
This article investigates the nonlinear behavior of the conventional voltage feedback flux-weakening control, i.e., the voltage magnitude feedback control on the nonsalient permanent magnet synchronous machine, and proposes an adaptive control parameter tuning method for the voltage feedback controller. Due to less voltage margin in the flux-weakening region, the current dynamic performance is degraded. This issue is more serious when the system operates in the overmodulation region and could affect the system's stability. Based on the designed voltage feedback controller, the system performance in the flux-weakening and overmodulation regions is further improved by utilizing the current and voltage reference modifiers. Consequently, the system can operate well in both linear and overmodulation regions with the specified scaling factor, which is beneficial to general-purpose applications. The viability of the proposed method is demonstrated by the experimental results.
- 29 April 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 67 (4) , 2655-2666
Analysis and Reduction of On-Load DC Winding Induced Voltage in Wound Field Switched Flux Machines
DC winding induced voltage pulsation in wound field switched flux (WFSF) machines causes DC winding current ripple and field excitation fluctuation, challenges the DC power source and deteriorates the control performance. Hence, reducing this pulsation is important in the design of a WFSF machine. In this paper, based on the analytical models, rotor skewing and rotor iron piece pairing are proposed and comparatively investigated by the finite element (FE) method to reduce the on-load DC winding induced voltage in WFSF machines having partitioned stators and concentrated AC windings. FE results show that peak to peak value of the on-load DC winding induced voltage in the analysed 12/10-pole partitioned stator WFSF (PS-WFSF) machines can be reduced by 78.42% or 77.16% by using rotor skewing or rotor pairing, respectively, whilst the torque density can be maintained by >90%. As for the 12/11-, 12/13- and 12/14-pole PS-WFSF machines, by using rotor iron piece inner arc pairing, the on-load DC winding induced voltage can be reduced by 64.11%, 52.12% and 76.49%, respectively, whilst the torque density can also be maintained by more than 90%. Prototypes are built and tested to verify the analytical and FE results.
- 29 April 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 67 (4) , 2655-2666
Analysis and Reduction of On-Load DC Winding Induced Voltage in Wound Field Switched Flux Machines
DC winding induced voltage pulsation in wound field switched flux (WFSF) machines causes DC winding current ripple and field excitation fluctuation, challenges the DC power source and deteriorates the control performance. Hence, reducing this pulsation is important in the design of a WFSF machine. In this paper, based on the analytical models, rotor skewing and rotor iron piece pairing are proposed and comparatively investigated by the finite element (FE) method to reduce the on-load DC winding induced voltage in WFSF machines having partitioned stators and concentrated AC windings. FE results show that peak to peak value of the on-load DC winding induced voltage in the analysed 12/10-pole partitioned stator WFSF (PS-WFSF) machines can be reduced by 78.42% or 77.16% by using rotor skewing or rotor pairing, respectively, whilst the torque density can be maintained by >90%. As for the 12/11-, 12/13- and 12/14-pole PS-WFSF machines, by using rotor iron piece inner arc pairing, the on-load DC winding induced voltage can be reduced by 64.11%, 52.12% and 76.49%, respectively, whilst the torque density can also be maintained by more than 90%. Prototypes are built and tested to verify the analytical and FE results.
- 1 July 2018
- Published by KSI Research Inc.
- Vol. 2018, 125-721
On the Problem-Oriented Validation of Cyber-Physical Systems Using System-Level Test Sequences (S)
- 1 July 2018
- Published by KSI Research Inc.
- Vol. 2018, 125-721
On the Problem-Oriented Validation of Cyber-Physical Systems Using System-Level Test Sequences (S)
- 12 June 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 33 (4) , 1825-1836
Influence of DC Winding Configuration on Its Induced Voltage in Wound Field Machines
DC winding induced voltage pulsation in the wound field synchronous machines (WFSMs) will cause DC winding current ripple, challenge the DC power supply and deteriorate the control performance, especially at a high speed. In this paper, the influence of DC winding configuration including the DC coil number and the parallel branch number on its induced voltage pulsation is investigated for WFSMs. Based on the modelling of both open-circuit and on-load DC winding induced voltages, the preferred DC winding configurations for WFSMs having various stator / rotor pole number combinations with double layer or single layer AC windings are obtained and validated by finite element (FE) analysis on four typical partitioned stator WFSMs (PS-WFSMs). A PS-WFSM prototype is built and tested to validate both analytical and FE analyses.
- 12 June 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 33 (4) , 1825-1836
Influence of DC Winding Configuration on Its Induced Voltage in Wound Field Machines
DC winding induced voltage pulsation in the wound field synchronous machines (WFSMs) will cause DC winding current ripple, challenge the DC power supply and deteriorate the control performance, especially at a high speed. In this paper, the influence of DC winding configuration including the DC coil number and the parallel branch number on its induced voltage pulsation is investigated for WFSMs. Based on the modelling of both open-circuit and on-load DC winding induced voltages, the preferred DC winding configurations for WFSMs having various stator / rotor pole number combinations with double layer or single layer AC windings are obtained and validated by finite element (FE) analysis on four typical partitioned stator WFSMs (PS-WFSMs). A PS-WFSM prototype is built and tested to validate both analytical and FE analyses.
- 24 May 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 66 (3) , 1715-1726
Reduction of Open-Circuit DC-Winding-Induced Voltage in Wound Field Switched Flux Machines by Skewing
In this paper, the open-circuit dc-winding-induced voltage in a wound field switched flux (WFSFs) machines is analyzed. The phenomenon of open-circuit dc-winding-induced voltage is illustrated and the mechanism is explained. Rotor skewing is proposed to reduce the open-circuit dc-winding-induced voltage, and the optimal skewing angle is analytically derived based on the analytically deduced harmonic orders of the open-circuit dc-winding-induced voltage. Finite-element (FE) analyses show that the open-circuit dc-winding-induced voltages in the analyzed 12-stator-pole partitioned stator WFSF machines having 10-, 11-, 13-, and 14-rotor-pole rotors can be effectively reduced by >94%, while the ac-winding phase-fundamental back-EMFs can be maintained by >95%. Twelve/ten-stator/rotor-pole prototypes with skewed and nonskewed rotors are built and tested to verify the analytical and FE results.
- 24 May 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 66 (3) , 1715-1726
Reduction of Open-Circuit DC-Winding-Induced Voltage in Wound Field Switched Flux Machines by Skewing
In this paper, the open-circuit dc-winding-induced voltage in a wound field switched flux (WFSFs) machines is analyzed. The phenomenon of open-circuit dc-winding-induced voltage is illustrated and the mechanism is explained. Rotor skewing is proposed to reduce the open-circuit dc-winding-induced voltage, and the optimal skewing angle is analytically derived based on the analytically deduced harmonic orders of the open-circuit dc-winding-induced voltage. Finite-element (FE) analyses show that the open-circuit dc-winding-induced voltages in the analyzed 12-stator-pole partitioned stator WFSF machines having 10-, 11-, 13-, and 14-rotor-pole rotors can be effectively reduced by >94%, while the ac-winding phase-fundamental back-EMFs can be maintained by >95%. Twelve/ten-stator/rotor-pole prototypes with skewed and nonskewed rotors are built and tested to verify the analytical and FE results.