Christine Klauser
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Christine Klauser has a total of 102 co-authors. Here are the top co-authors by number of shared publications:
- Bastian Märkisch
Physik-Department ENE Technische Universität München James-Franck Straße 1 85748 Garching Germany
3 shared publications - Hartmut Abele
Technische Universität Wien
3 shared publications Nataliya Rebrova
Physikalisches Institut, Universität Heidelberg, Im Neuenheimer Feld 226, 69120 Heidelberg, Germany
3 shared publicationsTorsten Soldner
Institut Laue-Langevin, 71 Avenue des Martyrs, CS 20156, 38042 Grenoble Cedex 9, France
3 shared publications- Torsten Soldner
Institut Laue-Langevin, CS 20156, 38042 Grenoble Cedex 9, France
3 shared publications - Anastasio Fratangelo
Albert Einstein Center for Fundamental Physics Laboratory for High Energy Physics University of Bern CH-3012 Bern Switzerland
2 shared publications
Latest Publications
- Open Access
Depolarization studies on low-depolarizing Cu/Ti and Ni(Mo)/Ti neutron supermirrors
Neutron supermirrors (SMs) are a crucial part of many scattering and particle physics experiments. So far, Ni(Mo)/Ti SMs have been used in experiments that require to transport a polarized neutron beam due to their lower saturation magnetization compared to Ni/Ti SMs. However, next generation $β$ decay experiments require SMs that depolarize below $10^{-4}$ per reflection to reach their targeted precision. The depolarization of a polarized neutron beam due to reflection from Ni(Mo)/Ti SMs has not yet been measured to that precision. Recently developed Cu/Ti SMs with a very low saturation magnetization compared to Ni(Mo)/Ti may serve as an alternative. In this paper, we test the performance of both mirrors. At a first stage, we present four-states polarized neutron reflectivity (PNR) curves of Ni(Mo) and Cu monolayers measured at the neutron reflectometer SuperADAM and perform a full polarization analysis, showing a difference between the magnetic scattering length density (mSLD) of both materials, with Cu having a lower mSLD than Ni(Mo). These results are corroborated with the full polarization analysis of four-states PNR curves of $m=2$ Ni(Mo)/Ti and Cu/Ti SMs. In a second stage, we measured the depolarization ($D$) that a polarized neutron beam suffers after reflection from the same Ni(Mo)/Ti and Cu/Ti SMs by using the Opaque Test Bench setup. We find upper limits for the depolarization of $D_\text{Cu/Ti(4N5)}<7.6\times 10^{-5}$, $D_\text{Ni(Mo)/Ti}<8.5\times 10^{-5}$, and $D_\text{Cu/Ti(2N6)}<6.0\times 10^{-5}$ at the $1σ$ confidence level, where (4N5) corresponds to a Ti purity of $99.995\%$ and (2N6) to $99.6\%$. The uncertainties are statistical. These results show that all three SMs are suitable for being used in next generation $β$ decay experiments. We found no noticeable dependence of $D$ on the $q$ value or the magnetizing field, in which the samples were placed.Open AccessDepolarization studies on low-depolarizing Cu/Ti and Ni(Mo)/Ti neutron supermirrors
Neutron supermirrors (SMs) are a crucial part of many scattering and particle physics experiments. So far, Ni(Mo)/Ti SMs have been used in experiments that require to transport a polarized neutron beam due to their lower saturation magnetization compared to Ni/Ti SMs. However, next generation $β$ decay experiments require SMs that depolarize below $10^{-4}$ per reflection to reach their targeted precision. The depolarization of a polarized neutron beam due to reflection from Ni(Mo)/Ti SMs has not yet been measured to that precision. Recently developed Cu/Ti SMs with a very low saturation magnetization compared to Ni(Mo)/Ti may serve as an alternative. In this paper, we test the performance of both mirrors. At a first stage, we present four-states polarized neutron reflectivity (PNR) curves of Ni(Mo) and Cu monolayers measured at the neutron reflectometer SuperADAM and perform a full polarization analysis, showing a difference between the magnetic scattering length density (mSLD) of both materials, with Cu having a lower mSLD than Ni(Mo). These results are corroborated with the full polarization analysis of four-states PNR curves of $m=2$ Ni(Mo)/Ti and Cu/Ti SMs. In a second stage, we measured the depolarization ($D$) that a polarized neutron beam suffers after reflection from the same Ni(Mo)/Ti and Cu/Ti SMs by using the Opaque Test Bench setup. We find upper limits for the depolarization of $D_\text{Cu/Ti(4N5)}<7.6\times 10^{-5}$, $D_\text{Ni(Mo)/Ti}<8.5\times 10^{-5}$, and $D_\text{Cu/Ti(2N6)}<6.0\times 10^{-5}$ at the $1σ$ confidence level, where (4N5) corresponds to a Ti purity of $99.995\%$ and (2N6) to $99.6\%$. The uncertainties are statistical. These results show that all three SMs are suitable for being used in next generation $β$ decay experiments. We found no noticeable dependence of $D$ on the $q$ value or the magnetizing field, in which the samples were placed. - 27 June 2024
- Published by American Physical Society (APS) in Physical Review C
- Vol. 109 (6) , 065503
Frequency-offset separated oscillatory fields technique applied to neutrons
The novel technique of frequency-offset separated oscillatory fields (FOSOF) was originally proposed as a modification to Ramsey's method of separated oscillatory fields. It has recently been employed in precision measurements with atomic beams since it allows for an alternative approach to determine absolute resonance frequencies. We present results from a systematic investigation of the FOSOF technique adapted to a beam of cold neutrons.
- 27 June 2024
- Published by American Physical Society (APS) in Physical Review C
- Vol. 109 (6) , 065503
Frequency-offset separated oscillatory fields technique applied to neutrons
The novel technique of frequency-offset separated oscillatory fields (FOSOF) was originally proposed as a modification to Ramsey's method of separated oscillatory fields. It has recently been employed in precision measurements with atomic beams since it allows for an alternative approach to determine absolute resonance frequencies. We present results from a systematic investigation of the FOSOF technique adapted to a beam of cold neutrons.
- Open Access
- 13 February 2024
- Published by MDPI AG in Quantum Beam Science
- Vol. 8 (1) , 8
New Ballistic Neutron Guide for the Time-of-Flight Spectrometer FOCUS at PSI
FOCUS is a direct-geometry cold neutron time-of-flight spectrometer at SINQ (PSI, CH). Its neutron guide was exchanged in 2019/2020 within the SINQ Upgrade project, while the rest of the instrument remained unchanged. The new guide provided a significant intensity increase across the whole spectrum, especially at short wavelengths, due to the more efficient transport and extended phase space of the transported neutrons. The practically available energy transfer range (at the neutron energy loss side) was increased to about 40 meV. The main reason for the intensity benefit at short incident wavelengths was the improved guide coating, whereas at long wavelengths it was the new ballistic shape. The interesting part of the guide is the “peanut shape” of the curved part in the horizontal plane. For this, we derived the analytical restriction on the geometry to avoid a direct line of sight from the source. The guide geometry and the supermirror coating were optimized using Mcoptimize, a particle swarm optimization routine employing Mcstas. Future ballistic neutron guides may profit from the presented approaches, optimization strategy, and results.
- 13 February 2024
- Published by MDPI AG in Quantum Beam Science
- Vol. 8 (1) , 8
Open AccessNew Ballistic Neutron Guide for the Time-of-Flight Spectrometer FOCUS at PSI
FOCUS is a direct-geometry cold neutron time-of-flight spectrometer at SINQ (PSI, CH). Its neutron guide was exchanged in 2019/2020 within the SINQ Upgrade project, while the rest of the instrument remained unchanged. The new guide provided a significant intensity increase across the whole spectrum, especially at short wavelengths, due to the more efficient transport and extended phase space of the transported neutrons. The practically available energy transfer range (at the neutron energy loss side) was increased to about 40 meV. The main reason for the intensity benefit at short incident wavelengths was the improved guide coating, whereas at long wavelengths it was the new ballistic shape. The interesting part of the guide is the “peanut shape” of the curved part in the horizontal plane. For this, we derived the analytical restriction on the geometry to avoid a direct line of sight from the source. The guide geometry and the supermirror coating were optimized using Mcoptimize, a particle swarm optimization routine employing Mcstas. Future ballistic neutron guides may profit from the presented approaches, optimization strategy, and results.
- Open Access
- 22 December 2023
- Published by American Physical Society (APS) in Physical Review C
- Vol. 108 (6) , 065501
Resonant cancellation effect in Ramsey-type nuclear magnetic resonance experiments
We investigate the response of a Ramsey-type experiment on an additional oscillating magnetic field. This superimposed field is oriented in the same direction as the static main magnetic field and causes a modulation of the original Larmor spin precession frequency. The observable magnitude of this modulation decreases at higher frequencies of the oscillating field. It disappears completely if the interaction time of the particles matches the oscillation period, which we call resonant cancellation. We present an analytical approach that describes the effect and compare it to a measurement using a monochromatic cold neutron beam.
- 22 December 2023
- Published by American Physical Society (APS) in Physical Review C
- Vol. 108 (6) , 065501
Open AccessResonant cancellation effect in Ramsey-type nuclear magnetic resonance experiments
We investigate the response of a Ramsey-type experiment on an additional oscillating magnetic field. This superimposed field is oriented in the same direction as the static main magnetic field and causes a modulation of the original Larmor spin precession frequency. The observable magnitude of this modulation decreases at higher frequencies of the oscillating field. It disappears completely if the interaction time of the particles matches the oscillation period, which we call resonant cancellation. We present an analytical approach that describes the effect and compare it to a measurement using a monochromatic cold neutron beam.
- Open Access
A non-depolarizing CuTi neutron supermirror guide for PERC
Neutron guides are used to transport slow neutrons from sources to experiments. Conventional neutron supermirror guides use alternating thin layers based on nickel and titanium. Due to the magnetic properties of nickel, their neutron reflection properties are spin-dependent, in particular when exposed to high magnetic fields. Motivated by the requirements of precision experiments on neutron beta decay, we present novel supermirrors based on copper and titanium, which preserve the neutron beam polarization. These show excellent reflectivity and prove to be very stable even when exposed to high temperatures.
Open AccessA non-depolarizing CuTi neutron supermirror guide for PERC
Neutron guides are used to transport slow neutrons from sources to experiments. Conventional neutron supermirror guides use alternating thin layers based on nickel and titanium. Due to the magnetic properties of nickel, their neutron reflection properties are spin-dependent, in particular when exposed to high magnetic fields. Motivated by the requirements of precision experiments on neutron beta decay, we present novel supermirrors based on copper and titanium, which preserve the neutron beam polarization. These show excellent reflectivity and prove to be very stable even when exposed to high temperatures.
- Open Access
- 27 January 2020
- Published by MDPI AG in Instruments
- Vol. 4 (1) , 4
The Logarithmic Spiral Neutron Guide
We present a neutron guide which is curved in the shape of a logarithmic spiral. Simulations and calculations for such a spiral guide are presented and the potential use of the guide for a reflectometer is investigated and compared to the conventional circularly curved guide geometry. We concentrate on the specific case of a beamport at the SINQ source. For this application, the spiral guide shows a 30% increased flux on the region of interest while at the same time reducing background scattering due to beam converging.
- 27 January 2020
- Published by MDPI AG in Instruments
- Vol. 4 (1) , 4
Open AccessThe Logarithmic Spiral Neutron Guide
We present a neutron guide which is curved in the shape of a logarithmic spiral. Simulations and calculations for such a spiral guide are presented and the potential use of the guide for a reflectometer is investigated and compared to the conventional circularly curved guide geometry. We concentrate on the specific case of a beamport at the SINQ source. For this application, the spiral guide shows a 30% increased flux on the region of interest while at the same time reducing background scattering due to beam converging.
- Open Access
- 12 December 2019
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 219, 04007
Design of the magnet system of the neutron decay facility PERC
The PERC (Proton and Electron Radiation Channel) facility is currently under construction at the research reactor FRM II, Garching. It will serve as an intense and clean source of electrons and protons from neutron beta decay for precision studies. It aims to contribute to the determination of the Cabibbo-Kobayashi-Maskawa quark-mixing element Vud from neutron decay data and to search for new physics via new effective couplings. PERC's central component is a 12 m long superconducting magnet system. It hosts an 8 m long decay region in a uniform field. An additional high-field region selects the phase space of electrons and protons which can reach the detectors and largely improves systematic uncertainties. We discuss the design of the magnet system and the resulting properties of the magnetic field.
- 12 December 2019
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 219, 04007
Open AccessDesign of the magnet system of the neutron decay facility PERC
The PERC (Proton and Electron Radiation Channel) facility is currently under construction at the research reactor FRM II, Garching. It will serve as an intense and clean source of electrons and protons from neutron beta decay for precision studies. It aims to contribute to the determination of the Cabibbo-Kobayashi-Maskawa quark-mixing element Vud from neutron decay data and to search for new physics via new effective couplings. PERC's central component is a 12 m long superconducting magnet system. It hosts an 8 m long decay region in a uniform field. An additional high-field region selects the phase space of electrons and protons which can reach the detectors and largely improves systematic uncertainties. We discuss the design of the magnet system and the resulting properties of the magnetic field.
- Open Access
- 1 May 2018
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1021 (1) , 012081
Simulation Methods and Results of the SINQ Cold Neutron Source Upgrade Study
Changing the configuration of the cold neutron source during a planned extended shutdown of the Swiss Spallation Neutron Source (SINQ) is being considered for improving performance of instruments at SINQ that use cold neutrons. The cold neutron source consists of a 20 L volume of liquid D2 at approximately 25 K. This study includes making the re-entrant hole external, redesigning the re-entrant hole geometry, adding a Pb-208 reflector, replacing the zirconium safety hulls, adding cryogenic beryllium reflector/filters, and incorporating an active ortho-D2 conversion loop. The optimization methods and the effects of the best-case modifications at all six neutron guides are presented. The best case design is predicted to yield a maximum gain factor of 1.5 in cold neutron intensity.
- 1 May 2018
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1021 (1) , 012081
Open AccessSimulation Methods and Results of the SINQ Cold Neutron Source Upgrade Study
Changing the configuration of the cold neutron source during a planned extended shutdown of the Swiss Spallation Neutron Source (SINQ) is being considered for improving performance of instruments at SINQ that use cold neutrons. The cold neutron source consists of a 20 L volume of liquid D2 at approximately 25 K. This study includes making the re-entrant hole external, redesigning the re-entrant hole geometry, adding a Pb-208 reflector, replacing the zirconium safety hulls, adding cryogenic beryllium reflector/filters, and incorporating an active ortho-D2 conversion loop. The optimization methods and the effects of the best-case modifications at all six neutron guides are presented. The best case design is predicted to yield a maximum gain factor of 1.5 in cold neutron intensity.