Yuichiro Sagawa
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yuichiro Sagawa has a total of 191 co-authors. Here are the top co-authors by number of shared publications:
- Yasuteru Yamauchi
Department of Cardiology Yokohama City Minato Red Cross Hospital Yokohama Japan
22 shared publications - Tetsuo Sasano
Department of Cardiovascular Medicine, Institute of Science Tokyo , 1-5-45 Yushima, Bunkyo-ku, Tokyo 113-8519
13 shared publications Atsuhito Oda
10 shared publications- Hirofumi Arai
Heart Center Japan Red Cross Yokohama City Bay Hospital Yokohama City Japan
10 shared publications Kazuya Murata
10 shared publicationsTetsuo Sasano
10 shared publications
Latest Publications
- Open Access
- 14 November 2026
- Published by Wiley in Journal of Arrhythmia
- Vol. 42 (6)
Successful Non‐Coronary Cusp Ablation in Type B Wolff–Parkinson–White Syndrome With an rS Pattern in Lead V1
- 14 November 2026
- Published by Wiley in Journal of Arrhythmia
- Vol. 42 (6)
Open AccessSuccessful Non‐Coronary Cusp Ablation in Type B Wolff–Parkinson–White Syndrome With an rS Pattern in Lead V1
- Open Access
- 1 November 2026
- Published by Wolters Kluwer Health in Circulation: Arrhythmia and Electrophysiology
- Vol. 19 (11)
Value of Left Ventricular Low Voltage Area and Ejection Fraction in Predicting End-Stage Heart Failure Outcomes After Ventricular Tachycardia Ablation in Patients With Non-Ischemic Cardiomyopathy
BACKGROUND: Patients with nonischemic cardiomyopathy (NICM) and ventricular tachycardia are at increased risk for adverse HF outcomes, and abnormal left ventricular (LV) substrate identified by endocardial unipolar and bipolar low-voltage areas (LVAs) may aid in risk stratification. This study assessed the association of LV unipolar and bipolar LVAs with end-stage HF outcomes in patients with NICM undergoing ventricular tachycardia ablation. METHODS: Patients with NICM and LV ejection fraction (LVEF) 2 cm 2 ) unipolar LVAs as ≤8.27 mV and bipolar LVAs as P =0.002) and LVEF (hazard ratio, 1.04 per 1% decrease [95% CI, 1.00–1.09]; P =0.03) were independently associated with higher end-stage HF risk, while bipolar LVA was not (hazard ratio, 0.98 1% increase [95% CI, 0.96–1.01]; P =0.25). A 3-point risk score based on the Youden index, unipolar LVA ≥70% (2 points), 35% to 70% (1 point), and LVEF ≤25% (1 point), had 82.1% sensitivity and 77.1% specificity for predicting end-stage HF in scores ≥2. CONCLUSIONS: In patients with NICM undergoing ventricular tachycardia ablation, unipolar LVA and LVEF are independent predictors of end-stage HF outcomes. Integrating these predictors yields a prognostic score to identify patients at the highest risk of end-stage HF outcomes.
- 1 November 2026
- Published by Wolters Kluwer Health in Circulation: Arrhythmia and Electrophysiology
- Vol. 19 (11)
Open AccessValue of Left Ventricular Low Voltage Area and Ejection Fraction in Predicting End-Stage Heart Failure Outcomes After Ventricular Tachycardia Ablation in Patients With Non-Ischemic Cardiomyopathy
BACKGROUND: Patients with nonischemic cardiomyopathy (NICM) and ventricular tachycardia are at increased risk for adverse HF outcomes, and abnormal left ventricular (LV) substrate identified by endocardial unipolar and bipolar low-voltage areas (LVAs) may aid in risk stratification. This study assessed the association of LV unipolar and bipolar LVAs with end-stage HF outcomes in patients with NICM undergoing ventricular tachycardia ablation. METHODS: Patients with NICM and LV ejection fraction (LVEF) 2 cm 2 ) unipolar LVAs as ≤8.27 mV and bipolar LVAs as P =0.002) and LVEF (hazard ratio, 1.04 per 1% decrease [95% CI, 1.00–1.09]; P =0.03) were independently associated with higher end-stage HF risk, while bipolar LVA was not (hazard ratio, 0.98 1% increase [95% CI, 0.96–1.01]; P =0.25). A 3-point risk score based on the Youden index, unipolar LVA ≥70% (2 points), 35% to 70% (1 point), and LVEF ≤25% (1 point), had 82.1% sensitivity and 77.1% specificity for predicting end-stage HF in scores ≥2. CONCLUSIONS: In patients with NICM undergoing ventricular tachycardia ablation, unipolar LVA and LVEF are independent predictors of end-stage HF outcomes. Integrating these predictors yields a prognostic score to identify patients at the highest risk of end-stage HF outcomes.
- Open Access
- 22 May 2026
- Published by Elsevier in JACC: Case Reports
- Vol. 31 (26) , 108372
Self-Reference and Atrial Pace Mapping With iPASO Identify Multiple Non-Pulmonary vein Triggers in Atrial Fibrillation
- 22 May 2026
- Published by Elsevier in JACC: Case Reports
- Vol. 31 (26) , 108372
Open AccessSelf-Reference and Atrial Pace Mapping With iPASO Identify Multiple Non-Pulmonary vein Triggers in Atrial Fibrillation
- Open Access
- 21 May 2026
- Published by Elsevier in JACC: Case Reports
- Vol. 31 (26) , 108386
Severe Hemoptysis Caused by Right Inferior Pulmonary Vein Perforation During Circular-Array Pulsed-Field Ablation
- 21 May 2026
- Published by Elsevier in JACC: Case Reports
- Vol. 31 (26) , 108386
Open AccessSevere Hemoptysis Caused by Right Inferior Pulmonary Vein Perforation During Circular-Array Pulsed-Field Ablation
- Open Access
- 3 December 2025
- Published by Elsevier in JACC: Case Reports
- Vol. 30 (39) , 106153
Pulsed-Field Ablation–Induced Coronary Vasospasm for Atrial Tachycardia Originating From the Lateral Tricuspid Annulus
- 3 December 2025
- Published by Elsevier in JACC: Case Reports
- Vol. 30 (39) , 106153
Open AccessPulsed-Field Ablation–Induced Coronary Vasospasm for Atrial Tachycardia Originating From the Lateral Tricuspid Annulus
- Open Access
- 17 October 2025
- Published by Wiley in Journal of Arrhythmia
- Vol. 41 (5) , e70208
Cryoballoon Ablation of the Left Common Pulmonary Vein Using a Size‐Adjustable Cryoballoon: A Comparative Study
Background: The efficacy of cryoballoon ablation (CBA) using a 28‐mm or 31‐mm cryoballoon for isolating the left common pulmonary vein (LCPV) remains poorly established. We aimed to evaluate procedural outcomes and long‐term follow‐up data of CBA for the LCPV using either POLARx with a fixed 28‐mm cryoballoon or POLARx FIT with a size‐adjustable 28‐mm or 31‐mm cryoballoon. Methods: Patients with LCPV who underwent CBA for atrial fibrillation using POLARx or POLARx FIT between January 2022 and April 2024 were retrospectively analyzed. Procedural outcomes and long‐term follow‐up data were compared between the POLARx and POLARx FIT groups. Results: Fifty‐one patients (32 males [62.7%]; mean age, 66 ± 11.6 years) were analyzed. The POLARx group included 23 patients, and the POLARx FIT group included 28 patients. First‐freeze pulmonary vein isolation (PVI) success was 1 (4.3%) versus 8 (28.6%) ( p = 0.03), and radiofrequency touch‐up ablation was required in 2 (8.7%) versus 0 patients ( p = 0.2) in the POLARx and POLARx FIT groups, respectively. Nadir temperature was −53.6° ± 4.7°C versus −54.7° ± 5.6°C ( p = 0.45); the number of applications was 3.2 ± 1 versus 2.3 ± 0.9 ( p < 0.01); and total freezing time was 520.9 ± 164 s versus 377.7 ± 129.9 s ( p < 0.01) for the POLARx and POLARx FIT groups, respectively. A single gastric hypomotility case was observed in the POLARx FIT group. The 1‐year arrhythmia‐free survival rates were 81.8% and 78.7% for the POLARx and POLARx FIT groups, respectively ( p = 0.96). Conclusions: POLARx FIT was useful for LCPV isolation, with a higher first‐freeze PVI success rate, fewer applications, and shorter total freezing time compared to POLARx.
- 17 October 2025
- Published by Wiley in Journal of Arrhythmia
- Vol. 41 (5) , e70208
Open AccessCryoballoon Ablation of the Left Common Pulmonary Vein Using a Size‐Adjustable Cryoballoon: A Comparative Study
Background: The efficacy of cryoballoon ablation (CBA) using a 28‐mm or 31‐mm cryoballoon for isolating the left common pulmonary vein (LCPV) remains poorly established. We aimed to evaluate procedural outcomes and long‐term follow‐up data of CBA for the LCPV using either POLARx with a fixed 28‐mm cryoballoon or POLARx FIT with a size‐adjustable 28‐mm or 31‐mm cryoballoon. Methods: Patients with LCPV who underwent CBA for atrial fibrillation using POLARx or POLARx FIT between January 2022 and April 2024 were retrospectively analyzed. Procedural outcomes and long‐term follow‐up data were compared between the POLARx and POLARx FIT groups. Results: Fifty‐one patients (32 males [62.7%]; mean age, 66 ± 11.6 years) were analyzed. The POLARx group included 23 patients, and the POLARx FIT group included 28 patients. First‐freeze pulmonary vein isolation (PVI) success was 1 (4.3%) versus 8 (28.6%) ( p = 0.03), and radiofrequency touch‐up ablation was required in 2 (8.7%) versus 0 patients ( p = 0.2) in the POLARx and POLARx FIT groups, respectively. Nadir temperature was −53.6° ± 4.7°C versus −54.7° ± 5.6°C ( p = 0.45); the number of applications was 3.2 ± 1 versus 2.3 ± 0.9 ( p < 0.01); and total freezing time was 520.9 ± 164 s versus 377.7 ± 129.9 s ( p < 0.01) for the POLARx and POLARx FIT groups, respectively. A single gastric hypomotility case was observed in the POLARx FIT group. The 1‐year arrhythmia‐free survival rates were 81.8% and 78.7% for the POLARx and POLARx FIT groups, respectively ( p = 0.96). Conclusions: POLARx FIT was useful for LCPV isolation, with a higher first‐freeze PVI success rate, fewer applications, and shorter total freezing time compared to POLARx.
- Open Access
- 9 September 2025
- Published by Wiley in Journal of Arrhythmia
- Vol. 41 (5) , e70186
Right Atrial Ablation for Premature Ventricular Contractions Originating From the Posterior‐Superior Process of the Left Ventricle: A Novel Therapeutic Approach
We experienced a case of premature ventricular contractions originating from the posterior‐superior process of the left ventricle that was successfully ablated from the right atrium where the A/V ratio was 5:1.
- 9 September 2025
- Published by Wiley in Journal of Arrhythmia
- Vol. 41 (5) , e70186
Open AccessRight Atrial Ablation for Premature Ventricular Contractions Originating From the Posterior‐Superior Process of the Left Ventricle: A Novel Therapeutic Approach
We experienced a case of premature ventricular contractions originating from the posterior‐superior process of the left ventricle that was successfully ablated from the right atrium where the A/V ratio was 5:1.
- Open Access
- 1 September 2025
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 27 (9)
Impact of cryoballoon size adjustability on procedural and clinical outcomes
- 1 September 2025
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 27 (9)
Open AccessImpact of cryoballoon size adjustability on procedural and clinical outcomes