PLPeter Lindahl

Peter Lindahl

*This is an algorithmically generated author record based on publicly available information.

Peter Lindahl has a total of 65 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Three-Phase Electrical Measurement Representations for Nonintrusive Load Diagnostics

    by Daisy H. Green, Peter A. Lindahl, Steven B. Leeb

    Electromechanical systems experience both gradual and sudden fault conditions. Power monitoring provides a valuable approach for detecting faults, essentially turning a machine into its own sensor for observing developing and abrupt failures. Machines can be monitored individually or nonintrusively (as a collection of loads) and signal processing can tease out relevant indicators of operational status and health. Load identification and diagnostics with aggregate electrical monitoring rely on the correct physical interpretation of measurements. Specifically, ties between the observed measurements and the actual physical task performed by a load ensure the relevance of a measurement, or a feature space derived from the measurement, for reliable identification and diagnostics. This article examines three-phase mathematical relationships for different load configurations, specifically with an eye toward selecting a feature space useful for automated diagnostics. The utility of these three-phase measurement representations is demonstrated with experimental data from several microgrid systems.


  • Nonintrusive Measurements for Detecting Progressive Equipment Faults

    by Daisy H. Green, Devin W. Quinn, Samuel Madden, Peter A. Lindahl, Steven B. Leeb

    The gradual environmental degradation of materials can lead to corrosion and mechanical failures of electrical loads. Vibration and corrosion both contribute to the failure of electrical connections and conductors, and electrical arcs destroy materials in ways that enhance the opportunities for further damage. These failures lead to loss of system capability and the possibility of electrical fires. The signatures of these impending electrical failures, which may occur over weeks or months, can be detected in many systems through nonintrusive electrical monitoring. This article demonstrates techniques for decoding the type of electrical signatures that lead to progressive failure. Example applications of these techniques are illustrated with observations of the degradation and failure of copper-sheathed jacket water (JW) heaters aboard a United States Coast Guard (USCG) vessel. Electrical, material, and vibration analysis are presented to demonstrate the basis for diagnostic electrical signatures.


  • Constant Power Load Modeling for a Programmable Impedance Control Strategy

    by Manuel Gutierrez, Peter A. Lindahl, Steven B. Leeb

    Expanded use of power electronics opens the possibility that input characteristics presented to the conventional utility as well as ac and dc microgrids could be controlled in ways that help support utility operation. Power factor correcting interfaces are one wide-spread example, used around the world to meet regulatory requirements for both power factor and also harmonic content injected to the utility. More support for ensuring healthy utility operation might be demanded from these power electronic interfaces. For example, the potentially destabilizing effects of constant power loads (CPLs) could be remediated on time scales useful for supporting utility operation. This article presents an equivalent circuit model for limited-bandwidth CPLs that quantifies the intrinsic damping properties of regulated converters. A control architecture based on this equivalent circuit model is then analyzed. The control scheme limits the impact of CPL operation by emulating the internal damping of CPLs through programmable input behavior. An intermediate, internal energy buffer is used to support CPL operation while enabling the programmable or selectable input impedance on designed time scales. The effectiveness of this strategy on system stability is shown using a stability analysis and experimental results.


  • Open Access

    Nonintrusive Load Monitoring of Variable Speed Drive Cooling Systems

    by Peter A. Lindahl, Muhammad Tauha Ali, Peter Armstrong, Andre Aboulian, John Donnal, Les Norford, Steven B. Leeb

    To improve the energy efficiencies of building cooling systems, manufacturers are increasingly utilizing variable speed drive (VSD) motors in system components, e.g. compressors and condensers. While these technologies can provide significant energy savings, these benefits are only realized if these components operate as intended and under proper control. Undetected faults can foil efficiency gains. As such, it’s imperative to monitor cooling system performance to both identify faulty conditions and to properly inform building or multi-building models used for predictive control and energy management. This paper presents nonintrusive load monitoring (NILM) based “mapping” techniques for tracking the performance of a building’s central air conditioning from smart electrical meter or energy monitor data. Using a multivariate linear model, a first mapping disaggregates the air conditioner’s power draw from that of the total building by exploiting the correlations between the building’s line-current harmonics and the power consumption of the air conditioner’s VSD motors. A second mapping then estimates the air conditioner’s heat rejection performance using as inputs the estimated power draw of the first mapping, the building’s zonal temperature, and the outside environmental temperature. The usefulness of these mapping techniques are demonstrated using data collected from a research facility building on the Masdar City Campus of Khalifa University. The mapping techniques combine to provide accurate estimates of the building’s air conditioning performance when operating under normal conditions. These estimates could thus be used as feedback in building energy management controllers and can provide a performance baseline for detection of air conditioner underperformance.


  • Know the Flow: Non-Contact Magnetic Flow Rate Sensing for Water Meters

    by Eric A. Ponce, Steven B. Leeb, Peter A. Lindahl

    Positive displacement water meters are found throughout the world’s water distribution networks to totalize water consumption. Containing internal permanent magnets, the water meters are underutilized sensors. Flow data from these meter locations can be used to non-intrusively identify the operation of individual water loads from an aggregate data stream at the meter. This paper models these meters as nonideal magnetic encoders and presents a methodology for inexpensively retrofitting these meters with digital flow rate measurement capabilities, effectively bringing them into the growing body of smart metering devices and non-intrusive load monitoring without any contact with the water passing through them. We present a model of the magnetic field produced by these meters, discuss associated magnetic sensing hardware, and describe compensation, flow rate estimation, and post-processing algorithms for flow rate extraction. Verification is provided with experimental results.


  • Autonomous Demand Smoothing for Efficiency Improvements on Military Forward Operating Bases

    by Spencer C. Shabshab, Peter A. Lindahl, Steven B. Leeb, John Kendall Nowocin

    This paper presents autonomous control algorithms for electrical loads like HVAC systems. These algorithms permit a load to become “aware” of the operation of neighboring loads using nonintrusive load monitoring (NILM) systems. Analogous to the way a good driver is aware of neighboring cars while driving, loads can use this information to become “self-driving”. For HVAC systems, this can mean maintaining occupant comfort while simultaneously reducing bulk peak electrical demand by consuming electric energy on a schedule interleaved with the operation of neighboring units. The algorithms are demonstrated here using models developed from NILM data collected from the microgrid of a US Army forward operating base (FOB). The general approach however could be applied in many other venues, e.g., to minimize peak load on distribution transformers in a section of the conventional utility.


  • Demand Smoothing in Military Microgrids Through Coordinated Direct Load Control

    by Spencer C. Shabshab, Peter A. Lindahl, J. Kendall Nowocin, John Donnal, David Blum, Les Norford, Steven B. Leeb

    In small microgrids and individual branches of a bulk electrical grid, the aggregate electrical load can contain significant and frequent peaks caused by large individual loads. These peaks can reduce overall system efficiencies if generation resources, e.g., diesel generators, are dispatched based on peak demand. This problem is particularly severe in military forward operating base (FOB) microgrids, in which the load profile is dominated by environmental control units (ECUs) that operate under thermostatic control. Leveraging the intrinsic energy storage capabilities associated with large loads such as these ECUs and coordinating their operations across neighboring facilities provides an opportunity to reduce peak demand while maintaining system performance. Using a military FOB microgrid as a use case, this paper presents two direct load control (DLC) algorithms for coordinating ECU operations and reducing peak demand. This coordinated control is demonstrated through simulations and field tests at the U.S. Army's Base Camp Integration Laboratory using novel controller hardware. Both simulation and field tests indicate that the DLC algorithms can reduce peak loads by 25% or more without sacrificing thermal comfort.


  • Open Access

    Voltage Waveform Transient Identification for Autonomous Load Coordination

    by Spencer C. Shabshab, Peter A. Lindahl, J. Kendall Nowocin, Steven B. Leeb

    Significant electrical loads such as HVAC systems can be made “aware” of the operation of other loads nearby in the electric grid. Local examination of the utility voltage waveform can provide this awareness without the need for a dedicated communication network. This is particularly true in low-inertia microgrids and “soft” sections of a utility network. This paper presents techniques for extracting frequency and voltage harmonic transients corresponding to individual load events. With data collected from a microgrid energized by diesel generators, we demonstrate the ability to identify the operation of HVAC units and generator dispatch events from their transient effects on the voltage using a cross-correlation based scoring algorithm. Ultimately, incorporating such awareness into load controllers allows loads to autonomously meet system-level objectives in addition to their individual requirements. For example, HVAC units could maintain occupant comfort while also reducing the utility’s peak aggregate electrical demand by consuming electricity on a schedule interleaved with the operation of other nearby HVAC units.


  • A MultiScale Framework for Nonintrusive Load Identification

    by Daisy H. Green, Steven R. Shaw, Peter Lindahl, Thomas J. Kane, John S. Donnal, Steven B. Leeb

    Nonintrusive load monitoring, i.e., the process of identifying individual load information from aggregate electrical measurements, is useful for a variety of smart grid applications including energy scorekeeping, condition monitoring, and activity tracking. Numerous load disaggregation algorithms have been used for nonintrusive monitoring. Many of these perform well only on certain datasets or load types, because transient electrical events can occur on vastly different time-scales and operating schedules with significantly different regularities. This paper presents a nonintrusive load monitoring framework that allows multiple algorithms to be used across multiple time-scales, with their outputs combined to enhance load recognition. Results are demonstrated with power system data from a United States Coast Guard Cutter (USCGC), demonstrating the utility of the framework for developing applications for condition-based maintenance, among other applications.