SJSamer Bou Jawde

Samer Bou Jawde

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Samer Bou Jawde has a total of 17 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Percolation of collagen stress in a random network model of the alveolar wall

    by Dylan T. Casey, Samer Bou Jawde, Jacob Herrmann, Vitor Mori, J. Matthew Mahoney, Béla Suki, Jason H. T. Bates

    Fibrotic diseases are characterized by progressive and often irreversible scarring of connective tissue in various organs, leading to substantial changes in tissue mechanics largely as a result of alterations in collagen structure. This is particularly important in the lung because its bulk modulus is so critical to the volume changes that take place during breathing. Nevertheless, it remains unclear how fibrotic abnormalities in the mechanical properties of pulmonary connective tissue can be linked to the stiffening of its individual collagen fibers. To address this question, we developed a network model of randomly oriented collagen and elastin fibers to represent pulmonary alveolar wall tissue. We show that the stress–strain behavior of this model arises via the interactions of collagen and elastin fiber networks and is critically dependent on the relative fiber stiffnesses of the individual collagen and elastin fibers themselves. We also show that the progression from linear to nonlinear stress–strain behavior of the model is associated with the percolation of stress across the collagen fiber network, but that the location of the percolation threshold is influenced by the waviness of collagen fibers.


  • Blood pressure-induced physiological strain variability modulates wall structure and function in aorta rings

    by Jasmin Imsirovic, Erzsébet Bartolák-Suki, Samer Bou Jawde, Harikrishnan Parameswaran, Béla Suki

    Vascular smooth muscle cells respond to mechanical stretch by reorganizing their cytoskeletal and contractile elements. Recently, we showed that contractile forces in rat aorta rings were maintained when the rings were exposed to 4 h of physiological variability in cycle-by-cycle strain, called variable stretch (VS), mimicking beat-to-beat blood pressure variability. Contractility, however, was reduced when the aorta was exposed to monotonous stretch (MS) with an amplitude equal to the mean peak strain of VS. Objective : Here we reanalyzed the data to obtain wall stiffness as well as added new histologic and inhibitor studies to test the effects of VS on the extracellular matrix. Main results : The results demonstrate that while the stiffness of the aorta did not change during 4 h MS or VS, nonlinearity in mechanical behavior was slightly stronger following MS. The inhibitor studies also showed that mitochondrial energy production and cytoskeletal organization were involved in this fluctuation-driven mechanotransduction. Reorganization of β -actin in the smooth muscle layer quantified from immunohistochemically labeled images correlated with contractile forces during contraction. Histologic analysis of wall structure provided evidence of reorganization of elastin and collagen fibers following MS but less so following VS. The results suggested that the loss of muscle contraction in MS was compensated by reorganization of fiber structure leading to similar wall stiffness as in VS. Significance : We conclude that muscle tone modulated by variability in stretch plays a role in maintaining aortic wall structural and mechanical homeostasis with implications for vascular conditions characterized by a loss or an increase in blood pressure variability.


  • Design and nonlinear modeling of a sensitive sensor for the measurement of flow in mice

    by Samer Bou Jawde, Bradford J Smith, Adam Sonnenberg, Jason H T Bates, Béla Suki

    Objective : While many studies rely on flow and pressure measurements in small animal models of respiratory disease, such measurements can however be inaccurate and difficult to obtain. Thus, the goal of this study was to design and implement an easy-to-manufacture and accurate sensor capable of monitoring flow. Approach : We designed and 3D printed a flowmeter and utilized parametric (resistance and inertance) and nonparametric (polynomial and Volterra series) system identification to characterize the device. The sensor was tested in a closed system for apparent flow using the common mode rejection ratio (CMRR). The sensor properly measured tidal volumes and respiratory rates in spontaneously breathing mice. The device was used to evaluate a ventilator’s ability to deliver a prescribed volume before and after lung injury. Main results : The parametric and polynomial models provided a reasonable prediction of the independently measured flow (Adjusted coefficient of determination = 0.9591 and 0.9147 respectively), but the Volterra series of the 1st, 2nd, and 3rd order with a memory of six time points provided better fits ( = 0.9775, 0.9787, and 0.9954, respectively). At and below the mouse breathing frequency (1–5 Hz), CMRR was higher than 40 dB. Following lung injury, the sensor revealed a significant drop in delivered tidal volume. Significance : We demonstrate that the application of nonparametric nonlinear Volterra series modeling in combination with 3D printing technology allows the inexpensive and rapid fabrication of an accurate flow sensor for continuously measuring small flows in various physiological conditions.


  • The effect of mechanical or electrical stimulation on apnea length in mice

    by Samer Bou Jawde, Alexandra Scheuermann, Erzsébet Bartolák-Suki, Béla Suki

    Premature birth is a leading cause of infant mortality which is often attributed to irregular breathing and apnea of prematurity. A common treatment for apnea is caffeine to stimulate the brain’s respiratory center. However, caffeine’s long term effect on infant development is not fully comprehended. We hypothesized that noninvasive localized body stimulation regularizes breathing pattern. We investigated the impact of electrical or mechanical stimulation on breathing in mice. After the mice were ventilated for 28 s to induce apnea, mice were taken off the ventilator while receiving mechanical, electrical, or no stimulation in a randomized order. Both stimuli targeted the diaphragm area through a custom-built belt with vibrating motors or adhesive electrodes. After each apnea cycle, the time to take the first breath (T) was recorded. The electrical stimulation given at 4.5, 8.3, 16.7 V (pulse rate = 3 Hz, pulse width = 120 μs) showed no reduction in T. Electrical stimulation at pulse rates of 10 or 20 Hz (16.7 V, pulse width 260 μs) showed a detrimental effect increasing T by ~ 7% compared to control values (p = 0.005, p = 0.038 respectively). High and medium intensity mechanical stimulations significantly reduced T by 11.74 (p < 10−13) and by 17.08% (p < 10−8), respectively. Further reducing the amplitude of vibrations did not affect T. When the probe was attached to the ankles, only the high intensity vibrations resulted in a decrease in T (p < 10−13). Mechanical vibrations, applied at various intensities and locations, could be used to treat irregular breathing and apnea in infants.


  • Eco-Brella: prototype development of the umbrella as harvester of solar and wind energies

    by Paul El Khoury, Yara Saadeh, Charbel Azzi, Samer Bu Jawdeh, Ramsey F. Hamade

    The familiar umbrella has been redesigned for power harvesting from renewable energy sources resulting in the Eco-Brella. Several engineering technologies are utilised: aerodynamics for fin design, mechatronics for power management, materials for thermoelectric and solar film, CAD for the layout, and heat transfer for human comfort. The result is a sustainable design capable of harvesting both solar and wind energies which are converted into electric power for the benefit of the individual carrying it. In windy climates, the Eco-Brella rotates by virtue of a light turbine which causes rotation of a dynamometer. Solar film is shaped into an umbrella-like configuration with efficient power conversion (10%-20% depending on conditions). Generated power is channeled through power management system capable of 1) charging a rechargeable battery from which other batteries of portable electronic devices are charged and/or 2) providing personal thermal comfort by blowing cool (hot) air on hot (cold) days.