Daren Gibson
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Daren Gibson has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Aanand N. Acharya
Fiona Stanley Fremantle Hospitals Group, Perth, WA 6150, Australia
1 shared publication - Alexander M. Bobinskas
Oral and Maxillofacial Surgery Department, The Canberra Hospital, Canberra, Australian Capital Territory, Australia
1 shared publication - Andy Whyte
University of Melbourne
1 shared publication - C.J. Wood
Fiona Stanley Hospital, 11 Robin Warren Dr, Murdoch, WA, 6160
1 shared publication - D.M. Girgis
Fiona Stanley Hospital, 11 Robin Warren Dr, Murdoch, WA, 6160
1 shared publication - Dayse Távora-Vieira
Fiona Stanley Fremantle Hospitals Group
1 shared publication
Latest Publications
- Open Access
- 20 August 2023
- Published by MDPI AG in Journal of Personalized Medicine
- Vol. 13 (8) , 1276
Evaluation of the Performance of OTOPLAN-Based Cochlear Implant Electrode Array Selection: A Retrospective Study
Otoplan is a surgical planning software designed to assist with cochlear implant surgery. One of its outputs is a recommendation of electrode array type based on imaging parameters. In this retrospective study, we evaluated the differences in auditory outcomes between patients who were implanted with arrays corresponding to those recommended by the Otoplan software versus those in which the array selection differed from the Otoplan recommendation. Pre-operative CT images from 114 patients were imported into the software, and array recommendations were generated. These were compared to the arrays which had actually been implanted during surgery, both in terms of array type and length. As recommended, 47% of patients received the same array, 34% received a shorter array, and 18% received a longer array. For reasons relating to structure and hearing preservation, 83% received the more flexible arrays. Those who received stiffer arrays had cochlear malformations or ossification. A negative, although non-statistically significant correlation was observed between the CNC scores at 12 months and the absolute value of the difference between recommended array and implanted array. In conclusion, clinicians may be slightly biased toward shorter electrode arrays due to their perceived greater ability to achieve full insertion. Using 3D imaging during the pre-operative planning may improve clinicians’ confidence to implant longer electrode arrays, where appropriate, to achieve optimum hearing outcomes.
- 20 August 2023
- Published by MDPI AG in Journal of Personalized Medicine
- Vol. 13 (8) , 1276
Open AccessEvaluation of the Performance of OTOPLAN-Based Cochlear Implant Electrode Array Selection: A Retrospective Study
Otoplan is a surgical planning software designed to assist with cochlear implant surgery. One of its outputs is a recommendation of electrode array type based on imaging parameters. In this retrospective study, we evaluated the differences in auditory outcomes between patients who were implanted with arrays corresponding to those recommended by the Otoplan software versus those in which the array selection differed from the Otoplan recommendation. Pre-operative CT images from 114 patients were imported into the software, and array recommendations were generated. These were compared to the arrays which had actually been implanted during surgery, both in terms of array type and length. As recommended, 47% of patients received the same array, 34% received a shorter array, and 18% received a longer array. For reasons relating to structure and hearing preservation, 83% received the more flexible arrays. Those who received stiffer arrays had cochlear malformations or ossification. A negative, although non-statistically significant correlation was observed between the CNC scores at 12 months and the absolute value of the difference between recommended array and implanted array. In conclusion, clinicians may be slightly biased toward shorter electrode arrays due to their perceived greater ability to achieve full insertion. Using 3D imaging during the pre-operative planning may improve clinicians’ confidence to implant longer electrode arrays, where appropriate, to achieve optimum hearing outcomes.
- 1 July 2018
- Published by Elsevier in British Journal of Oral and Maxillofacial Surgery
- Vol. 56 (6) , 531-535
Radiographic study to assess the reliability of the Gillies approach for biopsy of the superficial temporal artery
- 1 July 2018
- Published by Elsevier in British Journal of Oral and Maxillofacial Surgery
- Vol. 56 (6) , 531-535
Radiographic study to assess the reliability of the Gillies approach for biopsy of the superficial temporal artery
- 1 May 2018
- Published by Elsevier in European Journal of Radiology
- Vol. 102, 176-187
Imaging of adult obstructive sleep apnoea
- 1 May 2018
- Published by Elsevier in European Journal of Radiology
- Vol. 102, 176-187
Imaging of adult obstructive sleep apnoea