Fumihito Kato
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Fumihito Kato has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
Hirotsugu Ogi
Graduate School of Engineering Osaka University, Yamadaoka 2‐1, Suita Osaka 565‐0871 Japan
4 shared publicationsNoriyasu Masumoto
Department of Mechanical Engineering, Nippon Institute of Technology, Gakuendai 4-1, Miyashiro-machi, Minamisaitama, Saitama, 345-8501, Japan
3 shared publicationsHiroki Ato
Department of Mechanical Engineering, Nippon Institute of Technology, Gakuendai 4-1, Miyashiro-machi, Minamisaitama, Saitama, 345-8501, Japan
2 shared publicationsHiroyuki Noguchi
Nippon Institute of Technology, Minamisaitama-gun, Saitama, Japan
2 shared publicationsManabu Suzuki
Research Center for Advanced Materials and Technology Nippon Institute of Technology, Gakuendai 4‐1, Miyashiro‐machi, Minamisaitama Saitama 345‐8501 Japan
2 shared publicationsNaoya Oshida
Nippon Inst Technol, Fac Fundamental Engn, Dept Mech Engn, 4-1 Gakuendai,Miyashiro Machi, Minami Saitama, Saitama 3458501, Japan
2 shared publications
Latest Publications
- 9 January 2024
- Published by Wiley in IEEJ Transactions on Electrical and Electronic Engineering
- Vol. 19 (5) , 791-795
MEMS‐Based Ultra‐High Frequency Wireless 10 × 10 QCM Sensor Array for Biochemical Sensing Applications
- 9 January 2024
- Published by Wiley in IEEJ Transactions on Electrical and Electronic Engineering
- Vol. 19 (5) , 791-795
MEMS‐Based Ultra‐High Frequency Wireless 10 × 10 QCM Sensor Array for Biochemical Sensing Applications
- 17 November 2022
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 61 (12) , 126501
Improvement of hydrogen detection sensitivity of palladium film by in-plane compressive plastic deformation and application to hydrogen gas sensor
The hydrogen energy, which is environmentally friendly and does not emit carbon dioxide, has been attracting attention as an alternative fuel to the fossil fuel. In the shift to a hydrogen energy society, the highly sensitive hydrogen gas sensor has been required for the storage and management of hydrogen gas. In this study, we propose a film deposition method to induce the in-plane plastic deformation in the thin film and apply it to a hydrogen gas sensor, where the palladium film formed by this method is deposited on a thin quartz resonator. It is found that the sensor chip with the plastically deformed palladium film is about 1.5 times more sensitive than the conventional sensor chip and has high-speed response. The developed sensor is a novel device that can be used in an oxygen-free environment without any temperature compensation and constant heating.
- 17 November 2022
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 61 (12) , 126501
Improvement of hydrogen detection sensitivity of palladium film by in-plane compressive plastic deformation and application to hydrogen gas sensor
The hydrogen energy, which is environmentally friendly and does not emit carbon dioxide, has been attracting attention as an alternative fuel to the fossil fuel. In the shift to a hydrogen energy society, the highly sensitive hydrogen gas sensor has been required for the storage and management of hydrogen gas. In this study, we propose a film deposition method to induce the in-plane plastic deformation in the thin film and apply it to a hydrogen gas sensor, where the palladium film formed by this method is deposited on a thin quartz resonator. It is found that the sensor chip with the plastically deformed palladium film is about 1.5 times more sensitive than the conventional sensor chip and has high-speed response. The developed sensor is a novel device that can be used in an oxygen-free environment without any temperature compensation and constant heating.
- 8 March 2021
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 60 (SD) , SDDC01
Study on micropillar arrangement optimization of wireless-electrodeless quartz crystal microbalance sensor and application to a gas sensor
This paper studies the structural design of the wireless-electrodeless quartz crystal microbalance (QCM) sensor, which has a rectangular AT-cut quartz oscillator installed in the microchannel fabricated by nanoimprint lithography. The quartz oscillator was supported by the micropillars in the microchannel, and by optimizing the micropillar arrangement, it was found that the structural damping could be significantly reduced by performing the finite elemental piezoelectric analysis. This behavior was then confirmed by the experiments using the evaluation chips. By supporting the four corners of the quartz oscillator with the micropillars, the structural damping could be reduced, achieving a high-quality factor ( Q -factor) of about 24700. This high Q -factor was also realized in the experiments, and we investigated its application to a hydrogen-gas sensor. We succeeded in detecting hydrogen gas with an extremely low concentration of 10 ppm.
- 8 March 2021
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 60 (SD) , SDDC01
Study on micropillar arrangement optimization of wireless-electrodeless quartz crystal microbalance sensor and application to a gas sensor
This paper studies the structural design of the wireless-electrodeless quartz crystal microbalance (QCM) sensor, which has a rectangular AT-cut quartz oscillator installed in the microchannel fabricated by nanoimprint lithography. The quartz oscillator was supported by the micropillars in the microchannel, and by optimizing the micropillar arrangement, it was found that the structural damping could be significantly reduced by performing the finite elemental piezoelectric analysis. This behavior was then confirmed by the experiments using the evaluation chips. By supporting the four corners of the quartz oscillator with the micropillars, the structural damping could be reduced, achieving a high-quality factor ( Q -factor) of about 24700. This high Q -factor was also realized in the experiments, and we investigated its application to a hydrogen-gas sensor. We succeeded in detecting hydrogen gas with an extremely low concentration of 10 ppm.
- 25 October 2019
- Published by MYU K.K. in Sensors and Materials
- Vol. 31 (10) , 3173-3188
Electromagnetically Driven Micropump with Magnetic-fluid-sealed Thrust Bearing Contributing to Miniaturization of Medical Analytical Sensor Systems
- 25 October 2019
- Published by MYU K.K. in Sensors and Materials
- Vol. 31 (10) , 3173-3188
Electromagnetically Driven Micropump with Magnetic-fluid-sealed Thrust Bearing Contributing to Miniaturization of Medical Analytical Sensor Systems
- 8 June 2018
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 57 (7S1) , 07LD14
Wireless poly(dimethylsiloxane) quartz-crystal-microbalance biosensor chip fabricated by nanoimprint lithography for micropump integration aiming at application in lab-on-a-chip
We developed a quartz-crystal-microbalance (QCM) biosensor chip that operates wirelessly via electromagnetic waves, using poly(dimethylsiloxane) (PDMS). An AT-cut quartz oscillator (22–30 µm) is packaged in a microchannel, where it is supported by micropillars without mechanical fixing. As a result, the quartz oscillator is little affected by the thermal stress caused by the difference in the thermal expansion coefficients of the components, and the leakage of the vibration energy of the quartz oscillator is reduced. Consequently, high-frequency (∼56 MHz) measurement with a stable baseline (±∼2 ppm) is realized. We succeeded in repeatedly monitoring the binding reaction between immunoglobulin G (IgG) and Staphylococcus aureus protein A (SPA) with the quartz oscillator on which SPA molecules were immobilized nonspecifically. In addition, the affinity between SPA and IgG was calculated from the association and dissociation curves, and the usefulness of our wireless PDMS QCM biosensor was demonstrated.
- 8 June 2018
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 57 (7S1) , 07LD14
Wireless poly(dimethylsiloxane) quartz-crystal-microbalance biosensor chip fabricated by nanoimprint lithography for micropump integration aiming at application in lab-on-a-chip
We developed a quartz-crystal-microbalance (QCM) biosensor chip that operates wirelessly via electromagnetic waves, using poly(dimethylsiloxane) (PDMS). An AT-cut quartz oscillator (22–30 µm) is packaged in a microchannel, where it is supported by micropillars without mechanical fixing. As a result, the quartz oscillator is little affected by the thermal stress caused by the difference in the thermal expansion coefficients of the components, and the leakage of the vibration energy of the quartz oscillator is reduced. Consequently, high-frequency (∼56 MHz) measurement with a stable baseline (±∼2 ppm) is realized. We succeeded in repeatedly monitoring the binding reaction between immunoglobulin G (IgG) and Staphylococcus aureus protein A (SPA) with the quartz oscillator on which SPA molecules were immobilized nonspecifically. In addition, the affinity between SPA and IgG was calculated from the association and dissociation curves, and the usefulness of our wireless PDMS QCM biosensor was demonstrated.
- 1 July 2011
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 50 (7) , 07HD03
High-Frequency Electrodeless Quartz Crystal Microbalance Chip with a Bare Quartz Resonator Encapsulated in a Silicon Microchannel
- 1 July 2011
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 50 (7) , 07HD03
High-Frequency Electrodeless Quartz Crystal Microbalance Chip with a Bare Quartz Resonator Encapsulated in a Silicon Microchannel