Lingyun Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Lingyun Li has a total of 60 co-authors. Here are the top co-authors by number of shared publications:
- Donghui Xu
State Key Laboratory of Vegetable Biobreeding, Institute of Vegetables and Flowers, Key Laboratory of Vegetables Quality and Safety Control, Ministry of Agriculture and Rural Affairs of China, Ministry of Agriculture Vegetable Product Quality Safety Risk Assessment Laboratory, Ministry of Agriculture and Rural Affairs of China, Chinese Academy of Agricultural Sciences, Beijing, P. R. China
13 shared publications - Guangyang Liu
State Key Laboratory of Vegetable Biobreeding, Institute of Vegetables and Flowers, Chinese Academy of Agricultural Sciences, Key Laboratory of Vegetables Quality and Safety Control, Ministry of Agriculture and Rural Affairs of China, Beijing, China
11 shared publications - Xiaodong Huang
Institute of Vegetables and Flowers, Chinese Academy of Agricultural Sciences, Key Laboratory of Vegetables Quality and Safety Control, Laboratory of Quality & Safety Risk Assessment for vegetable Products, Ministry of Agriculture and Rural Affairs of China, Beijing 100081, China
10 shared publications - Ge Chen
State Key Laboratory of Vegetable Biobreeding, Institute of Vegetables and Flowers, Chinese Academy of Agricultural Sciences, Key Laboratory of Vegetables Quality and Safety Control, Ministry of Agriculture and Rural Affairs of China, Beijing 100081, China
4 shared publications - Jing Wang
National Nanfan Research Institute (Sanya), Chinese Academy of Agricultural Sciences, Sanya 572024, China
4 shared publications - Jun Lv
State Key Laboratory of Vegetable Biobreeding, Institute of Vegetables and Flowers, Chinese Academy of Agricultural Sciences, Key Laboratory of Vegetables Quality and Safety Control, Ministry of Agriculture and Rural Affairs of China, Beijing 100081, China
4 shared publications
Latest Publications
- Open Access
Matrix Interference of Vegetable on Enzyme-Linked Immunosorbent Assay for Parathion Residue Detection
Complex matrix of vegetable severely interferes with enzyme-linked immunosorbent assay (ELISA) accuracy, limiting its application in parathion residue detection. This study investigated the interference mechanism of vegetable matrix, including chlorophyll, perilla protein, glucose, fructose, and sucrose, on ELISA. Furthermore, we validated the vegetable matrix interference on parathion residue ELISA by comparing the matrix interference index (Im) and recovery rate of vegetable samples before and after acetic acid-treatment. The results demonstrate that the addition of vegetable matrix significantly interferes with ELISA, with the antibody–IgG-HRP binding being subject to the most pronounced interference. Compared to the Im (16–26%) of non-acetic acid treatment, the Im (10–13%) was significantly reduced after the acetic acid treatment. Concomitantly, spiked recovery experiments of acid-treated samples yielded satisfactory average recovery rate (80–113%) as the matrix interference was minimized. The findings of this study provide valuable insights into the mechanism of vegetable matrix interference on ELISA.
Open AccessMatrix Interference of Vegetable on Enzyme-Linked Immunosorbent Assay for Parathion Residue Detection
Complex matrix of vegetable severely interferes with enzyme-linked immunosorbent assay (ELISA) accuracy, limiting its application in parathion residue detection. This study investigated the interference mechanism of vegetable matrix, including chlorophyll, perilla protein, glucose, fructose, and sucrose, on ELISA. Furthermore, we validated the vegetable matrix interference on parathion residue ELISA by comparing the matrix interference index (Im) and recovery rate of vegetable samples before and after acetic acid-treatment. The results demonstrate that the addition of vegetable matrix significantly interferes with ELISA, with the antibody–IgG-HRP binding being subject to the most pronounced interference. Compared to the Im (16–26%) of non-acetic acid treatment, the Im (10–13%) was significantly reduced after the acetic acid treatment. Concomitantly, spiked recovery experiments of acid-treated samples yielded satisfactory average recovery rate (80–113%) as the matrix interference was minimized. The findings of this study provide valuable insights into the mechanism of vegetable matrix interference on ELISA.
- Open Access
Facile Preparation of Magnetic COF-on-COF for Rapid Adsorption and Determination of Sulforaphane from Cruciferous Vegetables
Sulforaphane (SFN) is a natural isothiocyanate compound widely abundant in cruciferous vegetables with multiple bioactive functions. However, traditional analytical methods for the extraction and determination of SFN are cumbersome, time-consuming, and low sensitivity with large amounts of organic solvents. Herein, novel magnetic COF-on-COFs (MB-COFs) were fabricated using Fe3O4 as a magnetic core and COFs-1 grown with COFs-2 as a shell, and they were used as efficient adsorbents of magnetic dispersive solid-phase extraction for rapid quantification of SFN in cruciferous vegetables by combining with HPLC-MS/MS. At the optimal ratio of COFs-1 to COFs-2, MB-COFs had a spherical cluster-like structure and a rough surface, with a sufficient magnetic response for rapid magnetic separation (1 min). Due to the introduction of Fe3O4 and COFs-2, MB-COFs exhibited outstanding extraction efficiencies for SFN (92.5–97.3%), which was about 18–72% higher than that of the bare COFs. Moreover, MB-COFs showed good adsorption capacity (Qm of 18.0 mg/g), rapid adsorption (5 min) and desorption (30 s) to SFN, and favorable reusability (≥7 cycles) by virtue of their unique hierarchical porous structure. The adsorption kinetic data were well fitted by the pseudo-second-order, Ritchie-second-order, intra-particle diffusion, and Elovich models, while the adsorption isotherm data were highly consistent with the Langmuir, Temkin, and Redlich–Peterson models. Finally, under the optimized conditions, the developed method showed a wide linear range (0.001–0.5 mg/L), high sensitivity (limits of quantification of 0.18–0.31 μg/L), satisfactory recoveries (82.2–96.2%) and precisions (1.8–7.9%), and a negligible matrix effect (0.82–0.97). Compared to previous methods, the proposed method is faster and more sensitive and significantly reduces the use of organic solvents, which can achieve the efficient detection of large-scale samples in practical scenarios. This work reveals the high practical potential of MB-COFs as adsorbents for efficient extraction and sensitive analysis of SFN in cruciferous vegetables.
Open AccessFacile Preparation of Magnetic COF-on-COF for Rapid Adsorption and Determination of Sulforaphane from Cruciferous Vegetables
Sulforaphane (SFN) is a natural isothiocyanate compound widely abundant in cruciferous vegetables with multiple bioactive functions. However, traditional analytical methods for the extraction and determination of SFN are cumbersome, time-consuming, and low sensitivity with large amounts of organic solvents. Herein, novel magnetic COF-on-COFs (MB-COFs) were fabricated using Fe3O4 as a magnetic core and COFs-1 grown with COFs-2 as a shell, and they were used as efficient adsorbents of magnetic dispersive solid-phase extraction for rapid quantification of SFN in cruciferous vegetables by combining with HPLC-MS/MS. At the optimal ratio of COFs-1 to COFs-2, MB-COFs had a spherical cluster-like structure and a rough surface, with a sufficient magnetic response for rapid magnetic separation (1 min). Due to the introduction of Fe3O4 and COFs-2, MB-COFs exhibited outstanding extraction efficiencies for SFN (92.5–97.3%), which was about 18–72% higher than that of the bare COFs. Moreover, MB-COFs showed good adsorption capacity (Qm of 18.0 mg/g), rapid adsorption (5 min) and desorption (30 s) to SFN, and favorable reusability (≥7 cycles) by virtue of their unique hierarchical porous structure. The adsorption kinetic data were well fitted by the pseudo-second-order, Ritchie-second-order, intra-particle diffusion, and Elovich models, while the adsorption isotherm data were highly consistent with the Langmuir, Temkin, and Redlich–Peterson models. Finally, under the optimized conditions, the developed method showed a wide linear range (0.001–0.5 mg/L), high sensitivity (limits of quantification of 0.18–0.31 μg/L), satisfactory recoveries (82.2–96.2%) and precisions (1.8–7.9%), and a negligible matrix effect (0.82–0.97). Compared to previous methods, the proposed method is faster and more sensitive and significantly reduces the use of organic solvents, which can achieve the efficient detection of large-scale samples in practical scenarios. This work reveals the high practical potential of MB-COFs as adsorbents for efficient extraction and sensitive analysis of SFN in cruciferous vegetables.
- 15 September 2023
- Published by Elsevier in Food Chemistry
- Vol. 434, 137482
Facile preparation of biomimetic mineralized COFs based on magnetic silk fibroin and its effective extraction of sulforaphane from cruciferous vegetables
- 15 September 2023
- Published by Elsevier in Food Chemistry
- Vol. 434, 137482
Facile preparation of biomimetic mineralized COFs based on magnetic silk fibroin and its effective extraction of sulforaphane from cruciferous vegetables
- Open Access
Comparison of Chemiluminescence Enzyme Immunoassay (Cl-ELISA) with Colorimetric Enzyme Immunoassay (Co-ELISA) for Imidacloprid Detection in Vegetables
Imidacloprid is one of the most commonly used insecticides for managing pests, thus, improving the quality and yield of vegetables. The abuse/misuse of imidacloprid contaminates the environment and threatens human health. To reduce the risk, a colorimetric enzyme-linked immunoassay assay (Co-ELISA) and chemiluminescence enzyme-linked immunoassay assay (Cl-ELISA) were established to detect imidacloprid residues in vegetables. The linear range of Co-ELISA ranged between 1.56 μg/L and 200 μg/L with a limit of detection (LOD) of 1.56 μg/L. The values for Cl-ELISA were 0.19 μg/L to 25 μg/L with an LOD of 0.19 μg/L, which are lower than those of Co-ELISA. Fortifying Chinese cabbage, cucumber, and zucchini with imidacloprid at 10, 50, and 100 μg/L yielded recoveries between 81.7 and 117.6% for Co-ELISA and at 5, 10, and 20 µg/L yielded recoveries range from 69.7 to 120.6% for Cl-ELISA. These results indicate that Cl-ELISA has a high sensitivity and a rapid detection time, saving cost (antigen and antibody concentrations) and serving as a more efficient model for the rapid detection of imidacloprid residue.
Open AccessComparison of Chemiluminescence Enzyme Immunoassay (Cl-ELISA) with Colorimetric Enzyme Immunoassay (Co-ELISA) for Imidacloprid Detection in Vegetables
Imidacloprid is one of the most commonly used insecticides for managing pests, thus, improving the quality and yield of vegetables. The abuse/misuse of imidacloprid contaminates the environment and threatens human health. To reduce the risk, a colorimetric enzyme-linked immunoassay assay (Co-ELISA) and chemiluminescence enzyme-linked immunoassay assay (Cl-ELISA) were established to detect imidacloprid residues in vegetables. The linear range of Co-ELISA ranged between 1.56 μg/L and 200 μg/L with a limit of detection (LOD) of 1.56 μg/L. The values for Cl-ELISA were 0.19 μg/L to 25 μg/L with an LOD of 0.19 μg/L, which are lower than those of Co-ELISA. Fortifying Chinese cabbage, cucumber, and zucchini with imidacloprid at 10, 50, and 100 μg/L yielded recoveries between 81.7 and 117.6% for Co-ELISA and at 5, 10, and 20 µg/L yielded recoveries range from 69.7 to 120.6% for Cl-ELISA. These results indicate that Cl-ELISA has a high sensitivity and a rapid detection time, saving cost (antigen and antibody concentrations) and serving as a more efficient model for the rapid detection of imidacloprid residue.
- Open Access
Magnetic Composite Based on Carbon Nanotubes and Deep Eutectic Solvents: Preparation and Its Application for the Determination of Pyrethroids in Tea Drinks
In this study, a novel composite material prepared by using deep eutectic solvent (tetrabutylammonium chloride-dodecanol, DES5) functionalized magnetic MWCNTs−ZIF−8 (MM/ZIF−8@DES5) was employed as an adsorbent for the magnetic solid-phase extraction of six pyrethroids from tea drinks. The characterization results show that MM/ZIF−8@DES5 possessed sufficient specific surface area and superparamagnetism, which could facilitate the rapid enrichment of pyrethroids from tea drink samples. The results of the optimization experiment indicated that DES5, which comprised tetrabutylammonium chloride and 1-dodecanol, was selected for the next experiment and that the adsorption properties of MM/ZIF−8@DES5 were higher than those of MM/ZIF−8 and M-MWCNTs. The validation results show that the method has a wide linear range (0.5–400 μg L−1, R2 ≥ 0.9905), low LOD (0.08–0.33 μg L−1), and good precision (intra-day RSD ≤ 5.6%, inter-day RSD ≤ 8.6%). The method was successfully applied to the determination of pyrethroids in three tea drink samples.
Open AccessMagnetic Composite Based on Carbon Nanotubes and Deep Eutectic Solvents: Preparation and Its Application for the Determination of Pyrethroids in Tea Drinks
In this study, a novel composite material prepared by using deep eutectic solvent (tetrabutylammonium chloride-dodecanol, DES5) functionalized magnetic MWCNTs−ZIF−8 (MM/ZIF−8@DES5) was employed as an adsorbent for the magnetic solid-phase extraction of six pyrethroids from tea drinks. The characterization results show that MM/ZIF−8@DES5 possessed sufficient specific surface area and superparamagnetism, which could facilitate the rapid enrichment of pyrethroids from tea drink samples. The results of the optimization experiment indicated that DES5, which comprised tetrabutylammonium chloride and 1-dodecanol, was selected for the next experiment and that the adsorption properties of MM/ZIF−8@DES5 were higher than those of MM/ZIF−8 and M-MWCNTs. The validation results show that the method has a wide linear range (0.5–400 μg L−1, R2 ≥ 0.9905), low LOD (0.08–0.33 μg L−1), and good precision (intra-day RSD ≤ 5.6%, inter-day RSD ≤ 8.6%). The method was successfully applied to the determination of pyrethroids in three tea drink samples.
- Open Access
Magnetic Solid-Phase Extraction of Pyrethroid Pesticides from Environmental Water Samples Using Deep Eutectic Solvent-type Surfactant Modified Magnetic Zeolitic Imidazolate Framework-8
A simple, sensitive and effective magnetic solid-phase extraction (MSPE) technique was developed for the extraction of pyrethroid pesticides from environmental water samples, followed by gas chromatography tandem triple quadrupole mass spectrometry determination. An adsorbent of magnetic zeolitic imidazolate framework-8@deep eutectic solvent (M-ZIF-8@DES) was prepared using deep eutectic solvent coated on the surface of M-ZIF-8. The features of M-ZIF-8@DES were confirmed by material characterizations, and the results indicated that M-ZIF-8@DES has a good magnetism (61.3 emu g−1), a decent surface area (96.83 m2 g−1) and pore volume (0.292 mL g−1). Single factor experiments were carried out to investigate the effect of different conditions on the performance of MSPE. Under the optimal conditions, the developed method performs good linearity (R2 ≥ 0.9916) in the concentration range of 1–500 μg L−1. The limits of detection were in the range of 0.05–0.21 μg L−1 (signal/noise = 3/1). The intraday relative standard deviation (RSD) and interday RSD were less than 9.40%. Finally, the proposed technique was applied for the determination of pyrethroid pesticides in environmental water samples. This work shows the potential of DES-modified metal-organic frameworks for different sample pretreatment techniques.
Open AccessMagnetic Solid-Phase Extraction of Pyrethroid Pesticides from Environmental Water Samples Using Deep Eutectic Solvent-type Surfactant Modified Magnetic Zeolitic Imidazolate Framework-8
A simple, sensitive and effective magnetic solid-phase extraction (MSPE) technique was developed for the extraction of pyrethroid pesticides from environmental water samples, followed by gas chromatography tandem triple quadrupole mass spectrometry determination. An adsorbent of magnetic zeolitic imidazolate framework-8@deep eutectic solvent (M-ZIF-8@DES) was prepared using deep eutectic solvent coated on the surface of M-ZIF-8. The features of M-ZIF-8@DES were confirmed by material characterizations, and the results indicated that M-ZIF-8@DES has a good magnetism (61.3 emu g−1), a decent surface area (96.83 m2 g−1) and pore volume (0.292 mL g−1). Single factor experiments were carried out to investigate the effect of different conditions on the performance of MSPE. Under the optimal conditions, the developed method performs good linearity (R2 ≥ 0.9916) in the concentration range of 1–500 μg L−1. The limits of detection were in the range of 0.05–0.21 μg L−1 (signal/noise = 3/1). The intraday relative standard deviation (RSD) and interday RSD were less than 9.40%. Finally, the proposed technique was applied for the determination of pyrethroid pesticides in environmental water samples. This work shows the potential of DES-modified metal-organic frameworks for different sample pretreatment techniques.
- 7 October 2019
- Published by Wiley in Journal of Food Science
- Vol. 84 (11) , 3296-3302
Application of Immunoassays for Rapid Monitor of Carbofuran Residue in Vegetables
Carbofuran residue in vegetables is a concern to human health. Direct competitive enzyme‐linked immunosorbent assay (dcELISA) and dipstick immunoassay were developed in the present study. The dcELISA showed a 50% inhibition concentration (IC 50 ) and working range of 1.3 and 0.2 to 7.5 ng/mL, respectively, while the cutoff value of dipstick immunoassay was 20 ng/mL. Applying the two immunoassays, we achieved the goal of rapid screening of carbofuran residue in commercial vegetables with a simple sample processing method. Among 46 leek, 39 potato, and 39 sweet potato samples, carbofuran residue was detected in 22% of the leek samples, and two samples exceeded the maximum residue limit of China (0.02 mg/kg). In addition, carbofuran residue was found at less than 2.5 ng/g in one potato and one sweet potato samples. The residual level of carbofuran measured by immunoassays agreed well with those determined by ultra‐performance liquid chromatography tandem mass spectrometry. To ensure food safety and human health, it is greatly necessary and meaningful to monitor carbofuran residue in commercial vegetables. Practical Application: Rapid monitoring of carbofuran residue in vegetables is very necessary and important for consumers, regulatory agencies, and food industry.
- 7 October 2019
- Published by Wiley in Journal of Food Science
- Vol. 84 (11) , 3296-3302
Application of Immunoassays for Rapid Monitor of Carbofuran Residue in Vegetables
Carbofuran residue in vegetables is a concern to human health. Direct competitive enzyme‐linked immunosorbent assay (dcELISA) and dipstick immunoassay were developed in the present study. The dcELISA showed a 50% inhibition concentration (IC 50 ) and working range of 1.3 and 0.2 to 7.5 ng/mL, respectively, while the cutoff value of dipstick immunoassay was 20 ng/mL. Applying the two immunoassays, we achieved the goal of rapid screening of carbofuran residue in commercial vegetables with a simple sample processing method. Among 46 leek, 39 potato, and 39 sweet potato samples, carbofuran residue was detected in 22% of the leek samples, and two samples exceeded the maximum residue limit of China (0.02 mg/kg). In addition, carbofuran residue was found at less than 2.5 ng/g in one potato and one sweet potato samples. The residual level of carbofuran measured by immunoassays agreed well with those determined by ultra‐performance liquid chromatography tandem mass spectrometry. To ensure food safety and human health, it is greatly necessary and meaningful to monitor carbofuran residue in commercial vegetables. Practical Application: Rapid monitoring of carbofuran residue in vegetables is very necessary and important for consumers, regulatory agencies, and food industry.
- 1 September 2019
- Published by Elsevier in Environmental Pollution
- Vol. 252, 689-696
Synergetic mediation of reduced graphene oxide and Cu(II) on the oxidation of 2-naphthol in water
- 1 September 2019
- Published by Elsevier in Environmental Pollution
- Vol. 252, 689-696
Synergetic mediation of reduced graphene oxide and Cu(II) on the oxidation of 2-naphthol in water
- Open Access
Magnetic Solid-Phase Extraction of Dichlorodiphenyltrichloroethane and Its Metabolites from Environmental Water Samples Using Ionic Liquid Modified Magnetic Multiwalled Carbon Nanotube/Zeolitic Imidazolate Framework-8 as Sorbent
As persistent organic pollutants, dichlorodiphenyltrichloroethanes (DDTs) and their metabolites pose considerable risks to human health and the environment. Therefore, monitoring DDTs in the environment is essential. Here, we developed a green, simple, and effective magnetic solid-phase extraction (MSPE) method coupled with gas chromatography tandem triple-quadrupole mass spectrometry to determine the DDT content of environmental water samples. A magnetic ionic liquid (IL) adsorbent was developed based on a modified magnetic multiwalled carbon nanotube/zeolitic imidazolate framework-8 (MM/ZIF-8/IL), synthesized by immobilizing the IL on the surface of MM/ZIF-8. We confirmed successful synthesis of MM/ZIF-8/IL by material characterization, and our results suggested that the MM/ZIF-8/IL had a high Brunauer–Emmett–Teller surface area (159.9 m2 g−1), good thermostability (−1). Several experimental conditions affecting the MSPE efficiency were optimized. Under the best conditions, good detection linearity was achieved (0.5–500 µg L−1) with determination coefficients ranging from 0.9927 to 0.9971. The lower limits of detection (0.0016–0.0072 µg L−1) also had good precision, having an intraday relative standard deviation (RSD) ≤ 6.5% and an interday RSD ≤ 8.9%. Finally, we used the as-developed method to determine DDT levels in environmental water samples.
Open AccessMagnetic Solid-Phase Extraction of Dichlorodiphenyltrichloroethane and Its Metabolites from Environmental Water Samples Using Ionic Liquid Modified Magnetic Multiwalled Carbon Nanotube/Zeolitic Imidazolate Framework-8 as Sorbent
As persistent organic pollutants, dichlorodiphenyltrichloroethanes (DDTs) and their metabolites pose considerable risks to human health and the environment. Therefore, monitoring DDTs in the environment is essential. Here, we developed a green, simple, and effective magnetic solid-phase extraction (MSPE) method coupled with gas chromatography tandem triple-quadrupole mass spectrometry to determine the DDT content of environmental water samples. A magnetic ionic liquid (IL) adsorbent was developed based on a modified magnetic multiwalled carbon nanotube/zeolitic imidazolate framework-8 (MM/ZIF-8/IL), synthesized by immobilizing the IL on the surface of MM/ZIF-8. We confirmed successful synthesis of MM/ZIF-8/IL by material characterization, and our results suggested that the MM/ZIF-8/IL had a high Brunauer–Emmett–Teller surface area (159.9 m2 g−1), good thermostability (−1). Several experimental conditions affecting the MSPE efficiency were optimized. Under the best conditions, good detection linearity was achieved (0.5–500 µg L−1) with determination coefficients ranging from 0.9927 to 0.9971. The lower limits of detection (0.0016–0.0072 µg L−1) also had good precision, having an intraday relative standard deviation (RSD) ≤ 6.5% and an interday RSD ≤ 8.9%. Finally, we used the as-developed method to determine DDT levels in environmental water samples.
- Open Access
- 18 July 2019
- Published by MDPI AG in Nanomaterials
- Vol. 9 (7) , 1030
Recent Advances and Perspectives of Molecularly Imprinted Polymer-Based Fluorescent Sensors in Food and Environment Analysis
Molecular imprinting technology (MIT), also known as molecular template technology, is a new technology involving material chemistry, polymer chemistry, biochemistry, and other multi-disciplinary approaches. This technology is used to realize the unique recognition ability of three-dimensional crosslinked polymers, called the molecularly imprinted polymers (MIPs). MIPs demonstrate a wide range of applicability, good plasticity, stability, and high selectivity, and their internal recognition sites can be selectively combined with template molecules to achieve selective recognition. A molecularly imprinted fluorescence sensor (MIFs) incorporates fluorescent materials (fluorescein or fluorescent nanoparticles) into a molecularly imprinted polymer synthesis system and transforms the binding sites between target molecules and molecularly imprinted materials into readable fluorescence signals. This sensor demonstrates the advantages of high sensitivity and selectivity of fluorescence detection. Molecularly imprinted materials demonstrate considerable research significance and broad application prospects. They are a research hotspot in the field of food and environment safety sensing analysis. In this study, the progress in the construction and application of MIFs was reviewed with emphasis on the preparation principle, detection methods, and molecular recognition mechanism. The applications of MIFs in food and environment safety detection in recent years were summarized, and the research trends and development prospects of MIFs were discussed.
- 18 July 2019
- Published by MDPI AG in Nanomaterials
- Vol. 9 (7) , 1030
Open AccessRecent Advances and Perspectives of Molecularly Imprinted Polymer-Based Fluorescent Sensors in Food and Environment Analysis
Molecular imprinting technology (MIT), also known as molecular template technology, is a new technology involving material chemistry, polymer chemistry, biochemistry, and other multi-disciplinary approaches. This technology is used to realize the unique recognition ability of three-dimensional crosslinked polymers, called the molecularly imprinted polymers (MIPs). MIPs demonstrate a wide range of applicability, good plasticity, stability, and high selectivity, and their internal recognition sites can be selectively combined with template molecules to achieve selective recognition. A molecularly imprinted fluorescence sensor (MIFs) incorporates fluorescent materials (fluorescein or fluorescent nanoparticles) into a molecularly imprinted polymer synthesis system and transforms the binding sites between target molecules and molecularly imprinted materials into readable fluorescence signals. This sensor demonstrates the advantages of high sensitivity and selectivity of fluorescence detection. Molecularly imprinted materials demonstrate considerable research significance and broad application prospects. They are a research hotspot in the field of food and environment safety sensing analysis. In this study, the progress in the construction and application of MIFs was reviewed with emphasis on the preparation principle, detection methods, and molecular recognition mechanism. The applications of MIFs in food and environment safety detection in recent years were summarized, and the research trends and development prospects of MIFs were discussed.