YPYelun Peng

Yelun Peng

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Yelun Peng has a total of 34 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Hierarchical Time-Series Assessment and Control for Transient Stability Enhancement in Islanded Microgrids

    by Yang Shen, Yelun Peng, Zhikang Shuai, Quan Zhou, Lipeng Zhu, Z. John Shen, Mohammad Shahidehpour

    The grid-forming converters would integrate battery energy storage systems (BESSs) in islanded microgrids for smoothing out the uncertain fluctuations of renewable energy resources. However, gird-forming converters would pose transient instability risks under large disturbances, which could require fast and accurate stability assessment methods in such challenging and uncertain cases. In this work, a hierarchical time-series assessment and control (HTSAC) framework is proposed for assessing the transient stability of grid-forming converters in islanded microgrids. The proposed HTSAC framework offers a gated recurrent unit (GRU) neural network alternative for an intuitive and accurate trajectory prediction in early post-fault stages. Subsequently, an emergency ride-through control (ERC) strategy is proposed which leverages the proposed neural network approach for enhancing the prediction results in real-time assessments of microgrid transient stability. The initial input horizon of GRU is optimized to avoid intense trial-and-error design burdens incurred in conventional data-driven assessment methods. Simulation and experimental results are presented to validate the effectiveness of the proposed HTSAC on an islanded microgrid in south China. The results also point out that the GRU of the prediction layer with a quantile loss function would ensure a timely ERC in the proposed HTSAC approach to renewable energy-based converter operations.


  • Transient Stabilization Control of Electric Synchronous Machine for Preventing the Collapse of DC-Link Voltage

    by Yelun Peng, Zhikang Shuai, Chao Shen, Xiaochao Hou, Z. John Shen

    Electric synchronous machine (ESM) control is a power synchronization strategy that utilizes the measurement of dc-link voltage to generate a frequency reference. By using ESM, the grid-connected inverters with indeterminant renewable energies can work in grid-forming mode, and realizes a closed-loop control of the dc-link voltage. However, under weak grid conditions, the ESM provides a sluggish performance for the regulation of dc-link voltage and is prone to the transient instability issues, including dc-voltage collapse and synchronization instability, which hinders the application of ESM. This paper reveals the instability mechanism of dc-link voltage under large disturbances, and proposes a passivity-based control for the transient stabilization of ESM. Firstly, the transient stability of ESM is analyzed from the view of port-Hamilton system. The corresponding energy function comprises the energy stored in dc-link capacitor and potential energy in ac side. Then, a 2-degree-of-fredom controller is proposed to stabilize the dc-link voltage by enhancing the energy dissipation. It combines a phase-shift controller and supplementary voltage controller, fully utilizing the control flexibility of the inverters. Dissipation analysis proves the large-signal stability of the proposed control. Simulations and hardware-in-the-loop (HIL) experiments validate its transient performance in a single-inverter-infinite-bus (SIIB) system and a multi-inverter test system.


  • Transient Synchronization Stability Analysis and Enhancement of Paralleled Converters Considering Different Current Injection Strategies

    by Xiangtong Yi, Yelun Peng, Quan Zhou, Wen Huang, Lijia Xu, Z. John Shen, Zhikang Shuai

    Renewable energy sources (RESs) are highly penetrated in power systems through phase-locked loop (PLL) synchronized converters. Under severe grid voltage sags, PLL-synchronized RES system is susceptive to transient instability and tripping from the grid due to inappropriate current injection. The existing literatures mainly focus on synchronization instability issues of a single grid-connected RES system, and the effect of the interaction between them is rarely studied. To fill this gap, this paper aims to clarify the interaction mechanism and characterize stability boundary of paralleled PLL-synchronized RES system with different converter parameters. More specifically, the effect of current injection angle and magnitude on transient synchronization stability is investigated for guiding current injection reference design during low voltage ride-through (LVRT) and rated capacity option of RESs. First, the transient interaction model of the paralleled converter system is developed, and interaction mechanism under different current injection angles is revealed. Next, stability region analysis is performed to evaluate the impact of current injection magnitude, wherein current injection boundary is obtained. Then, a current injection design method is proposed for improving both transient stability and voltage support. The theoretical analysis and the proposed method are validated by simulation results.


  • Single-Phase to Ground Fault Line Identification for Medium Voltage Islanded Microgrids With Neutral Ineffectively Grounded Modes

    by Lili He, Yang Li, Xu Chu, Zhikang Shuai, Yelun Peng, Z. John Shen

    Considering single-phase to ground (SPG) faults accounting for more than 80% of all faults, neutral ineffectively grounded mode (NIGM) is the most promising choice for medium voltage (MV) islanded microgrids (MGs) to enhance operation reliability. But due to the weak fault current and flexible network topology of islanded MGs, it is difficult to detect SPG fault lines. To solve this issue, this paper firstly analyzes the SPG fault characteristics of the MV islanded MGs with different NIGMs and network topologies. It is found that the looped MGs have a virtual terminal, i.e., the point where zero-sequence current (ZSC) is zero. And the feature differences between fault and non-fault lines are revealed. Based on that, an SPG fault line identification method is proposed. The main criterion is constructed based on the skewness signs of high frequency zero-sequence voltage (ZSV) and ZSC. Additionally, the fundamental amplitude of the difference between the actual ZSC received from another terminal and the ZSC calculated from local ZSV and ZSC is used to formulate an auxiliary criterion. Finally, the effectiveness of the proposed method is validated in a 10kV islanded MG model considering different NIGMs, different fault conditions, arc grounding faults, and the influences of the line parameter, operating point and measurement noises.


  • Open Access

    Multilevel Dynamic Master-Slave Control Strategy for Resilience Enhancement of Networked Microgrids

    by Rui Huang, Yu Xiao, Mouhai Liu, Xia Shen, Wen Huang, Yelun Peng, John Shen

    Conventional power management methods of networked microgrids (NMGs) are limited to the failure of pinned communication terminals and heavy communication burdens. This paper proposes a multilevel dynamic master-slave control strategy via two-level dynamic leaders to realize the resilience enhanced power management of NMGs. The first level dynamic leader with considerations of distributed energy resources (DERs) feature is selected to guide the output of DERs and achieve the power management within individual microgrid (MG). Subsequently, the secondary level leader considering each MG feature is selected among the bidirectional interlinking converters (BICs), whose signals would be shared with other BICs by communication to achieve power management among MGs. Moreover, the local weight selecting method (LWSM) is proposed to automatically select the two-level dynamic leaders according to the real-time system operation state. Compared with conventional methods, the communication among MGs is essentially realized through the dynamic DER leaders instead of pinned ones. Therefore, unreliability issues in the event of pinned terminal outage and converters’ communication failure can be fully addressed and the communication bus within each only needs to transmit one DER’s signals. The proposed strategy can be also extended to NMGs with various topologies and provide the “plug and play” capabilities of DERs or MGs. Finally, the effectiveness and feasibility of the proposed strategy are verified through the PSCAD/EMTDC platform.


  • Dynamic Stability Improvement and Accurate Power Regulation of Single-Phase Virtual Oscillator Based Microgrids

    by Yelun Peng, Zhikang Shuai, Liang Che, Mingcheng Lyu, Z. John Shen

    Thanks to its fast self-synchronization capability, the virtual oscillator control (VOC) has become an emerging control technique for grid-connected inverters, especially in single-phase applications. Nevertheless, the nonlinearity of VOC inverters impacts its dynamic behavior, and there is a trade-off between the system stability and accurate power regulation in VOC-based microgrids. This paper studies the dynamic stability of VOC inverters for guiding the parameter design. Then, based on the analysis result, an improved VOC strategy with hybrid power regulation structure is proposed for improving both the system stability and power regulation of VOC-based microgrids. First, a dynamic phasor (DP) model of single-phase VOC-based microgrids with multiple control loops is developed. Second, a stability region analysis of VOC parameters is performed, the proper mode setting and robust parameter design of VOC inverters are provided. Third, the improved VOC strategy is presented, achieving accurate power sharing, fast voltage recovery and adequate stability margin. The proposed parameter design and improved VOC strategy are validated by simulation and hardware-in the-loop experiment.


  • Transient Voltage Stability of Paralleled Synchronous and Virtual Synchronous Generators With Induction Motor Loads

    by Huijie Cheng, Wen Huang, Chao Shen, Yelun Peng, Zhikang Shuai, Z. John Shen

    Parallel operation of synchronous generators (SGs) and virtual synchronous generators (VSGs) is an important way to guarantee the safe operation of the microgrid in remote islands or rural areas. However, the system may experience transient voltage instability when a high penetration level of induction motor (IM) loads is connected. This paper considers the dynamics of SG and VSG to investigate the transient voltage stability of paralleled SG and VSG system with IM load. The effects of SG’s and VSG’s active power loops (APLs) are analyzed in detail due to the low inertia of microgrids and the power coupling introduced by the network impedance, which has not been well-explored in the prior research. The results show that the interaction of APLs between SG and VSG would deteriorate the transient voltage stability of the system. Moreover, critical clearance time (CCT) is employed to estimate the system stability. Based on the theoretical analysis, a control method is proposed to enhance the transient voltage stability of the system. The hardware-in-loop experiment is performed to verify the correctness of the theoretical analysis.


  • Top Cited Papers

    Transient Stability and Current Injection Design of Paralleled Current-Controlled VSCs and Virtual Synchronous Generators

    by Chao Shen, Zhikang Shuai, Yang Shen, Yelun Peng, Xuan Liu, Zuyi Li, Z. John Shen

    With development of power electronic technology, the paralleled current-controlled voltage source converters (CCSs) and virtual synchronous generators (VSGs) system has advantages in providing power and voltage/frequency regulation at the same time in rural area or remote island. However, the paralleled system faces great challenges in safe and stable operation due to their limited thermal capacity and weak anti-disturbance ability, especially during fault periods. This paper focuses on transient stability and stability-oriented control design of the paralleled CCS-VSG system. First, mathematical model of the paralleled system is established and then the effect of two kinds of CCSs’ current injection angle (active current and reactive current) on VSG’s transient stability has been revealed through extended equal area criterion. Based on the theoretical analysis results, transient stability improvement control is put forward by controlling the CCS to track the VSG’s frame. Compared with the conditions that only active-or reactive current is provided by the CCS, the system can achieve the best transient performance when the proposed control is adopted. Moreover, the effect of CCS’s capacity on transient stability of the VSG has also been discussed. Finally, both Lyapunov’s method and simulation/experimental results are provided to validate the correctness of theoretical analysis.


  • Open Access

    Analysis and Design of PI Plus Repetitive Control for Grid-Side Converters of Direct-Drive Wind Power Systems Considering the Effect of Hardware Sampling Circuits

    by Mingcheng Lyu, Lerong Hong, Qianming Xu, Wu Liao, Gongping Wu, Shoudao Huang, Yelun Peng, Xin Long

    In inverters based on a single proportional-integral (PI) or deadbeat (DB) controller, an inherent resonance peak may emerge near their current loop cut-off frequency, which results in harmonic amplification or even resonance. Additionally, inappropriate filter circuits implemented in sampling circuits may result in the expansion of the resonance peak. Thus, this paper further investigates the influence of the sampling circuits on a PI-or DB-based control loop. Then, the RC filter in the sampling circuit is designed to reduce the inherent resonance peak. Moreover, a compound control strategy based on an improved repetitive controller (IRC) plus a PI controller is adopted for the grid-side converter of a direct-drive wind system. This strategy enhances the harmonic and reactive compensation performance by reconstructing the internal model of the classic repetitive controller (CRC) and limiting the bandwidth of the PI-based loop to a low level. The parameters of the presented IRC-plus-PI control are designed for the purpose of resonance peak elimination and system stability. Furthermore, the non-integer delay problem is solved with an inserted fraction compensator (FC), which plays the role of a low-pass filter in the IRC. Finally, the feasibility and effectiveness of the presented control method is verified by the experimental results.


  • Performance Improvement of the Unbalanced Voltage Compensation in Islanded Microgrid Based on Small-Signal Analysis

    by Yelun Peng, Zhikang Shuai, Josep M. Guerrero, Yong Li, An Luo, Zheng John Shen

    A low-voltage microgrid is naturally three-phase unbalance due to the connection of unbalanced loads. Voltage unbalance compensation (VUC) strategies of inverters have been proposed to compensate the voltage unbalance on the point of common coupling. However, the small-signal analysis of these VUC strategies has not been investigated in a microgrid with multiple inverters, which is due to the difficulty of the state-space modeling for unbalanced microgrids. This lack of discussion may result in a poor performance of the microgrid when the parameters of VUCs are not well designed. To investigate the dynamic behavior of the unbalanced microgrid with VUC strategies, this article develops a detailed state-space model for an unbalanced microgrid using the dynamic phasor method. Then, based on the developed model, small-signal analysis is carried out to investigate the effect of the VUC control on the dynamic behavior of a microgrid. It is found that a poor design of the VUC controllers may result in the instability of the microgrid. Finally, an improved compensation method with better compensation performance is proposed. Experimental results are used to validate the effectiveness of the proposed method.