Mohamed El Barghouti
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Mohamed El Barghouti has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
Abdellah Mir
Laboratory of Optics, Information Processing, Mechanics, Energetics and Electronics, Department of Physics, Moulay Ismail University of Meknès, Meknès, Morocco
11 shared publicationsAbdellatif Akjouj
University of Lille, Institute of Electronics, Microelectronics and Nanotechnology, UMR CNRS 8520, Villeneuve d’Ascq, France
8 shared publications- Abdellatif Akjouj
Département de Physique, Institut d’Electronique, de Microélectronique et de Nanotechnologie (IEMN), UMR CNRS 8520, Université de Lille, Villeneuve d’Ascq Cédex, France
5 shared publications Fatima Houari
2 shared publications- Fatima Houari
Laboratory of Optics, Information Processing, Mechanics, Energetics and Electronics, Department of Physics, Moulay Ismail University of Meknès, Meknès, Morocco
2 shared publications Abdelkrim Talbi
1 shared publication
Latest Publications
- 9 September 2026
- Published by Springer Nature in Plasmonics
- Vol. 21 (9) , 3527-3543
Advanced Design of Kretschmann Based SPR Biosensor, Combining Cu Nanolayer, Perovskite Oxides and 2D-Nanomaterials for Ultrasensitive Detection
- 9 September 2026
- Published by Springer Nature in Plasmonics
- Vol. 21 (9) , 3527-3543
Advanced Design of Kretschmann Based SPR Biosensor, Combining Cu Nanolayer, Perovskite Oxides and 2D-Nanomaterials for Ultrasensitive Detection
- Open Access
Nanosensors Based on Bimetallic Plasmonic Layer and Black Phosphorus: Application to Urine Glucose Detection
This paper presents a new biosensor design based on the Kretschmann configuration, for the detection of analytes at different refractive indices. Our studied design consists of a TiO2/SiO2 bi-layer sandwiched between a BK7 prism and a bimetallic layer of Ag/Au plasmonic materials, covered by a layer of black phosphorus placed below the analyte-containing detection medium. The different layers of our structure and analyte detection were optimized using the angular interrogation method. High performance was achieved, with a sensitivity of 240 deg/RIU and a quality factor of 34.7 RIU−1. This biosensor can detect analytes with a wide refractive index range between 1.330 and 1.347, such as glucose detection in urine samples using a refractive index variation of . This capability offers a wide range of applications for biomedical and biochemical detection and selectivity.Open AccessNanosensors Based on Bimetallic Plasmonic Layer and Black Phosphorus: Application to Urine Glucose Detection
This paper presents a new biosensor design based on the Kretschmann configuration, for the detection of analytes at different refractive indices. Our studied design consists of a TiO2/SiO2 bi-layer sandwiched between a BK7 prism and a bimetallic layer of Ag/Au plasmonic materials, covered by a layer of black phosphorus placed below the analyte-containing detection medium. The different layers of our structure and analyte detection were optimized using the angular interrogation method. High performance was achieved, with a sensitivity of 240 deg/RIU and a quality factor of 34.7 RIU−1. This biosensor can detect analytes with a wide refractive index range between 1.330 and 1.347, such as glucose detection in urine samples using a refractive index variation of . This capability offers a wide range of applications for biomedical and biochemical detection and selectivity. - 25 July 2024
- Published by Elsevier in Optical Materials
- Vol. 155
Surface plasmon resonance sensors: Temperature effects
- 25 July 2024
- Published by Elsevier in Optical Materials
- Vol. 155
Surface plasmon resonance sensors: Temperature effects
- 16 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (13) , 20452-20459
Enhancing Tamm Plasmon Sensor Performance Using Nanostructured Gold Grating and Porous Materials
In this paper, we introduce a gas sensor concept consisting of a nanostructured gold grating coupled with a Distributed Bragg Reflector. This coupling makes it possible to obtain plasmonic Tamm states where excitation is possible at normal incidence and does not require the use of Kretschmann configuration. Through parameters optimization of the gold nanostructured grating, we achieved well-defined and localized Tamm resonances between the gold nanostructured grating and the Distributed Bragg Reflector composed of SiO 2 /Si 3 N 4 . To exploit the spatial confinement of the energy of the Tamm states in order to measure the change in refractive index, we propose three configurations in which we substitute the last nitride layer in the Bragg Reflector with porous materials. In the first configuration, we use a porous nitride portion with 30% porosity, producing sensitivity S = 170nm/RIU and figure of merit FOM = 27.1 RIU -1 . In the second configuration, we use a porous nitride layer with a porosity of 30% (S = 175nm/RIU, FOM = 27.3 RIU -1 ). Finally, the third configuration adopts a 66% porous silicon layer (S = 268nm/RIU, FOM = 43.6 RIU -1 ). These values show significant potential for sensing applications.
- 16 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (13) , 20452-20459
Enhancing Tamm Plasmon Sensor Performance Using Nanostructured Gold Grating and Porous Materials
In this paper, we introduce a gas sensor concept consisting of a nanostructured gold grating coupled with a Distributed Bragg Reflector. This coupling makes it possible to obtain plasmonic Tamm states where excitation is possible at normal incidence and does not require the use of Kretschmann configuration. Through parameters optimization of the gold nanostructured grating, we achieved well-defined and localized Tamm resonances between the gold nanostructured grating and the Distributed Bragg Reflector composed of SiO 2 /Si 3 N 4 . To exploit the spatial confinement of the energy of the Tamm states in order to measure the change in refractive index, we propose three configurations in which we substitute the last nitride layer in the Bragg Reflector with porous materials. In the first configuration, we use a porous nitride portion with 30% porosity, producing sensitivity S = 170nm/RIU and figure of merit FOM = 27.1 RIU -1 . In the second configuration, we use a porous nitride layer with a porosity of 30% (S = 175nm/RIU, FOM = 27.3 RIU -1 ). Finally, the third configuration adopts a 66% porous silicon layer (S = 268nm/RIU, FOM = 43.6 RIU -1 ). These values show significant potential for sensing applications.
- 5 February 2024
- Published by Elsevier in Optical Materials
- Vol. 149
Engineering and optimization of the SPR device ZnO/Ag/WO3/Ni/2D-Nanomaterials highly sensitive for biomedical processing and detection
- 5 February 2024
- Published by Elsevier in Optical Materials
- Vol. 149
Engineering and optimization of the SPR device ZnO/Ag/WO3/Ni/2D-Nanomaterials highly sensitive for biomedical processing and detection
- 3 October 2022
- Published by Elsevier in Materials Today Communications
- Vol. 33
Modeling of surface plasmon resonance biosensor based on Ag/BiFeO3/Ni using 2D nanomaterial perovskite MAPbBr3
- 3 October 2022
- Published by Elsevier in Materials Today Communications
- Vol. 33
Modeling of surface plasmon resonance biosensor based on Ag/BiFeO3/Ni using 2D nanomaterial perovskite MAPbBr3
Performance evaluation of multifunctional SPR bimetallic sensor using hybrid 2D-nanomaterials layers
- 6 February 2022
- Published by Springer Nature in Applied Physics A
- Vol. 128 (3) , 1-15
High-performance bimetallic layer plasmonic sensors: a comparative study among Ti$_{3}$C$_{2}$T$_{x}$, black phosphorus and WS$_{2}$- 6 February 2022
- Published by Springer Nature in Applied Physics A
- Vol. 128 (3) , 1-15
High-performance bimetallic layer plasmonic sensors: a comparative study among Ti$_{3}$C$_{2}$T$_{x}$, black phosphorus and WS$_{2}$- Open Access
- 1 March 2020
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 783 (1)
Enhancement of localized surface plasmon resonances of silver nanoparticles array upon the presence of graphene coatings: LSPR biosensor
We study, in this article, the resonance of localized surface plasmon (LSPR) on silver nanoparticles (AgNPs) deposited on a glass substrate and coated with a graphene. The resonance peaks in the absorption spectra of the nanostructure SiOx/AgNPs/Graphene, show significantly different profiles such as the thickness of the graphene, and the refractive index of the surrounding environment which is, gradually, varied. Numerical simulation reveals that movements in plasmon resonance peaks result from coupling between the AgNPs networks and the covering graphene layer. In addition, the LSPR modes shift to red from 412 nm to 548 nm when the thickness of the graphene layer deposited on silver nanoparticles changes from 0.34 nm to 9 nm. Light coupled with LSPR modes propagating along a AgNPs-graphene interface is calculated and compared to a conventional AgNPs-based LSPR biosensor. The result of the comparison depicts an improvement in the sensitivity of the biosensor from 26 to 106 nm/RIU.
- 1 March 2020
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 783 (1)
Open AccessEnhancement of localized surface plasmon resonances of silver nanoparticles array upon the presence of graphene coatings: LSPR biosensor
We study, in this article, the resonance of localized surface plasmon (LSPR) on silver nanoparticles (AgNPs) deposited on a glass substrate and coated with a graphene. The resonance peaks in the absorption spectra of the nanostructure SiOx/AgNPs/Graphene, show significantly different profiles such as the thickness of the graphene, and the refractive index of the surrounding environment which is, gradually, varied. Numerical simulation reveals that movements in plasmon resonance peaks result from coupling between the AgNPs networks and the covering graphene layer. In addition, the LSPR modes shift to red from 412 nm to 548 nm when the thickness of the graphene layer deposited on silver nanoparticles changes from 0.34 nm to 9 nm. Light coupled with LSPR modes propagating along a AgNPs-graphene interface is calculated and compared to a conventional AgNPs-based LSPR biosensor. The result of the comparison depicts an improvement in the sensitivity of the biosensor from 26 to 106 nm/RIU.