Liang Miao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Liang Miao has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Cheng-Gang Mo
Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China
1 shared publication Chuang Sun
Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China
1 shared publicationGuoqing Yang
Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China
1 shared publicationXin Zhang
Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China
1 shared publication- Xin Zhang
Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China
1 shared publication - Xin-Dong Chen
Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China
1 shared publication
Latest Publications
- Open Access
Theoretical Analysis and Optimization Strategies of Wavefront Errors and Chromatic Aberrations Induced by Optical Coatings
This research addresses the frequently overlooked wavefront errors and chromatic aberrations in optical coatings. It identifies intrinsic phase shifts within the coating system as the primary cause of these aberrations, rather than errors in surface form accuracy. This study investigates the impact of group delay () on wavefront errors in optical coatings. The results reveal that contributes significantly to wavefront errors in two cases: when coatings exhibit thickness non-uniformity and when they operate over a wide range of incident angles. At a single incident angle, wavefront errors are only induced when both and thickness non-uniformity exist. In the case of a wide range of incident angles, even in the absence of thickness non-uniformity, still introduces wavefront errors. This study introduces novel optimization strategies for thin-film components through theoretical derivation, aiming to minimize wavefront errors by optimizing .Open AccessTheoretical Analysis and Optimization Strategies of Wavefront Errors and Chromatic Aberrations Induced by Optical Coatings
This research addresses the frequently overlooked wavefront errors and chromatic aberrations in optical coatings. It identifies intrinsic phase shifts within the coating system as the primary cause of these aberrations, rather than errors in surface form accuracy. This study investigates the impact of group delay () on wavefront errors in optical coatings. The results reveal that contributes significantly to wavefront errors in two cases: when coatings exhibit thickness non-uniformity and when they operate over a wide range of incident angles. At a single incident angle, wavefront errors are only induced when both and thickness non-uniformity exist. In the case of a wide range of incident angles, even in the absence of thickness non-uniformity, still introduces wavefront errors. This study introduces novel optimization strategies for thin-film components through theoretical derivation, aiming to minimize wavefront errors by optimizing . - 19 June 2018
- Published by Optica Publishing Group in Applied Optics
- Vol. 57 (18) , 5217-5223
High-accuracy measurement of the focal length and distortion of optical systems based on interferometry
A figure measuring interferometer (FMI) method is proposed for high-accuracy measurement of the focal length and distortion of optical systems simultaneously. FMI uses the Zernike coefficients of interference fringe to identify the image point position precisely, and then measures the distance between the image points under the different fields to determine the image height. The field of view can also be accurately obtained by a precise rotating platform. Linear fitting between the field of view and the image height is used to calculate the focal length and distortion. The experimental results indicate that FMI has a relative expanded standard uncertainty of less than 0.01% for focal length and 0.02% for distortion. In brief, the proposed method is feasible for measurement of the focal length and distortion with high accuracy, promising further industrial applications.
- 19 June 2018
- Published by Optica Publishing Group in Applied Optics
- Vol. 57 (18) , 5217-5223
High-accuracy measurement of the focal length and distortion of optical systems based on interferometry
A figure measuring interferometer (FMI) method is proposed for high-accuracy measurement of the focal length and distortion of optical systems simultaneously. FMI uses the Zernike coefficients of interference fringe to identify the image point position precisely, and then measures the distance between the image points under the different fields to determine the image height. The field of view can also be accurately obtained by a precise rotating platform. Linear fitting between the field of view and the image height is used to calculate the focal length and distortion. The experimental results indicate that FMI has a relative expanded standard uncertainty of less than 0.01% for focal length and 0.02% for distortion. In brief, the proposed method is feasible for measurement of the focal length and distortion with high accuracy, promising further industrial applications.