Amin Zammouri
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Amin Zammouri has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
Abdelaziz Ait Moussa
4 shared publicationsA. Ait Moussa
Department of Computer Science, Faculty of Sciences, Mohammed First University, Av. Med VI, P.B. 717, 60000 Oujda, Morocco
1 shared publication- Abdelaziz Ait Moussa
Department of Computer Sciences, Faculty of Sciences, Mohammed First University, Oujda, Morocco
1 shared publication Abdelaziz Aitmoussa
Department of Mathematics and Computer Sciences, Faculty of Sciences, Mohammed First University, Av Med VI, BP 717, 60000, Oujda, Morocco
1 shared publication- Abderrazak Hajjioui
Life and Health Sciences Laboratory, Faculty of Medicine and Pharmacy, Abdelmalek Essaâdi University, Tangier 90000, Morocco
1 shared publication Eric Monacelli
Laboratoire d'Ingénierie des Systèmes de Versailles, Université de Versailles Saint-Quentin-en-Yvelines, Vélizy-Villacoublay 78140, France
1 shared publication
Latest Publications
- 3 November 2023
- Published by Elsevier
- p. 427-439
Africa region: Morocco
- 24 August 2023
- Published by Elsevier in Expert Systems with Applications
- Vol. 237
Use of cognitive load measurements to design a new architecture of intelligent learning systems
- 24 August 2023
- Published by Elsevier in Expert Systems with Applications
- Vol. 237
Use of cognitive load measurements to design a new architecture of intelligent learning systems
- 1 June 2021
- Published by Springer Nature
- p. 215-227
Prototype of a BCI-Based Autonomous Communicating Robot for Disability Assessment
- 1 June 2021
- Published by Springer Nature
- p. 215-227
Prototype of a BCI-Based Autonomous Communicating Robot for Disability Assessment
- 1 December 2018
- Published by Elsevier in Expert Systems with Applications
- Vol. 112, 138-147
Brain-computer interface for workload estimation: Assessment of mental efforts in learning processes
- 1 December 2018
- Published by Elsevier in Expert Systems with Applications
- Vol. 112, 138-147
Brain-computer interface for workload estimation: Assessment of mental efforts in learning processes
- Open Access
- 22 October 2017
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 904 (1) , 012008
Brain waves-based index for workload estimation and mental effort engagement recognition
The advent of the communication systems and considering the complexity that some impose in their use, it is necessary to incorporate and equip these systems with a certain intelligence which takes into account the cognitive and mental capacities of the human operator. In this work, we address the issue of estimating the mental effort of an operator according to the cognitive tasks difficulty levels. Based on the Electroencephalogram (EEG) measurements, the proposed approach analyzes the user's brain activity from different brain regions while performing cognitive tasks with several levels of difficulty. At a first time, we propose a variances comparison-based classifier (VCC) that makes use of the Power Spectral Density (PSD) of the EEG signal. The aim of using such a classifier is to highlight the brain regions that enter into interaction according to the cognitive task difficulty. In a second time, we present and describe a new EEG-based index for the estimation of mental efforts. The designed index is based on information recorded from two EEG channels. Results from the VCC demonstrate that powers of the Theta [4-7 Hz] (θ) and Alpha [8-12 Hz] (α) oscillations decrease while increasing the cognitive task difficulty. These decreases are mainly located in parietal and temporal brain regions. Based on the Kappa coefficients, decisions of the introduced index are compared to those obtained from an existing index. This performance assessment method revealed strong agreements. Hence the efficiency of the introduced index.
- 22 October 2017
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 904 (1) , 012008
Open AccessBrain waves-based index for workload estimation and mental effort engagement recognition
The advent of the communication systems and considering the complexity that some impose in their use, it is necessary to incorporate and equip these systems with a certain intelligence which takes into account the cognitive and mental capacities of the human operator. In this work, we address the issue of estimating the mental effort of an operator according to the cognitive tasks difficulty levels. Based on the Electroencephalogram (EEG) measurements, the proposed approach analyzes the user's brain activity from different brain regions while performing cognitive tasks with several levels of difficulty. At a first time, we propose a variances comparison-based classifier (VCC) that makes use of the Power Spectral Density (PSD) of the EEG signal. The aim of using such a classifier is to highlight the brain regions that enter into interaction according to the cognitive task difficulty. In a second time, we present and describe a new EEG-based index for the estimation of mental efforts. The designed index is based on information recorded from two EEG channels. Results from the VCC demonstrate that powers of the Theta [4-7 Hz] (θ) and Alpha [8-12 Hz] (α) oscillations decrease while increasing the cognitive task difficulty. These decreases are mainly located in parietal and temporal brain regions. Based on the Kappa coefficients, decisions of the introduced index are compared to those obtained from an existing index. This performance assessment method revealed strong agreements. Hence the efficiency of the introduced index.
- 1 January 2017
- Published by Inderscience Publishers in International Journal of Embedded Systems
- Vol. 9 (4) , 321
Eye blinks artefacts detection in a single EEG channel
In clinical conditions, the EEG measurements are mainly influenced by muscles and ocular movements, especially eye blinks. In this work, we present a new method to detect and reject eye blinks from a single-channel EEG signal. In an offline use mode, the proposed approach is based on statistical computations. It aims, in a first time, at estimating the pure EEG data interval. In a second time, we seek to improve the errors that may occur during the first step by using the Fisher-Snedecor test. By using ROC performance metrics, kappa coefficient and signal-to-artefact ratio (SAR), the proposed method is compared to an expert detection and to single-channel independent component analysis (SC-ICA), one of the widely used and robust methods for artefacts rejection. Experimental results show large values even when using the expert's annotation and the comparison to the SC-ICA method. This reflects the efficiency of the proposed method in detecting and rejecting blinks from a single-channel EEG signal.
- 1 January 2017
- Published by Inderscience Publishers in International Journal of Embedded Systems
- Vol. 9 (4) , 321
Eye blinks artefacts detection in a single EEG channel
In clinical conditions, the EEG measurements are mainly influenced by muscles and ocular movements, especially eye blinks. In this work, we present a new method to detect and reject eye blinks from a single-channel EEG signal. In an offline use mode, the proposed approach is based on statistical computations. It aims, in a first time, at estimating the pure EEG data interval. In a second time, we seek to improve the errors that may occur during the first step by using the Fisher-Snedecor test. By using ROC performance metrics, kappa coefficient and signal-to-artefact ratio (SAR), the proposed method is compared to an expert detection and to single-channel independent component analysis (SC-ICA), one of the widely used and robust methods for artefacts rejection. Experimental results show large values even when using the expert's annotation and the comparison to the SC-ICA method. This reflects the efficiency of the proposed method in detecting and rejecting blinks from a single-channel EEG signal.
- 1 October 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 517-520
Evaluating usability of brain signals for content adaptation in intelligent tutoring systems
Designing intelligent tutoring systems (ITS) requires appropriate assessment tools to ensure a good usability by learners. In this work we discuss the process of content adaptation in ITS. We study and assess the usability of a brain-activity-based approach to address the issue of content adaptation in ITS. The approach aims at continuously assessing the learners' mental states during a learning task. Results from this investigation are motivating to design future content adaptation architectures of ITS which take advantage from brain signals.
- 1 October 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 517-520
Evaluating usability of brain signals for content adaptation in intelligent tutoring systems
Designing intelligent tutoring systems (ITS) requires appropriate assessment tools to ensure a good usability by learners. In this work we discuss the process of content adaptation in ITS. We study and assess the usability of a brain-activity-based approach to address the issue of content adaptation in ITS. The approach aims at continuously assessing the learners' mental states during a learning task. Results from this investigation are motivating to design future content adaptation architectures of ITS which take advantage from brain signals.
- 1 March 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
SafeBrowse: A new tool for strengthening and monitoring the security configuration of web browsers
Among the attacks against a user's computer, the current trend of cybercriminals is to focus their strikes on the web browser. The common operational mode among these attacks is the misconfiguration of the browser security settings in order to facilitate access to the user's machine. In this paper we investigate the prevention level of browsers against such attacks. Our investigation covers the popular browsers on Windows platforms as well as the Firefox browser available on the Android operating system. As a result of this investigation, we developed and evaluated a new system for monitoring the security settings of browsers. This system can be used to significantly enhance the protection level offered by browsers.
- 1 March 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
SafeBrowse: A new tool for strengthening and monitoring the security configuration of web browsers
Among the attacks against a user's computer, the current trend of cybercriminals is to focus their strikes on the web browser. The common operational mode among these attacks is the misconfiguration of the browser security settings in order to facilitate access to the user's machine. In this paper we investigate the prevention level of browsers against such attacks. Our investigation covers the popular browsers on Windows platforms as well as the Firefox browser available on the Android operating system. As a result of this investigation, we developed and evaluated a new system for monitoring the security settings of browsers. This system can be used to significantly enhance the protection level offered by browsers.
- 1 March 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Intelligentocular artifacts removal in a noninvasive singlechannel EEG recording
Muscle noises, line noises and eye movements are the main interferences that make difficulties when interpreting and analyzing electroencephalographic signals. Many methods have been proposed for artifacts removing from EEG measurements, and especially those arising from an ocular source. Principal Component Analysis (PCA) and Independent Component Analysis (ICA) have been proposed to remove ocular artifacts from multichannel EEG. In contrast to this, we present a new algorithm for ocular artifacts removal from a single electroencephalographic channel recording. This method is based on a set of information on brain wave frequencies. Our results on EEG data, collected from healthy subjects, show that our algorithm can effectively detect and remove ocular artifacts in EEG recordings.
- 1 March 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Intelligentocular artifacts removal in a noninvasive singlechannel EEG recording
Muscle noises, line noises and eye movements are the main interferences that make difficulties when interpreting and analyzing electroencephalographic signals. Many methods have been proposed for artifacts removing from EEG measurements, and especially those arising from an ocular source. Principal Component Analysis (PCA) and Independent Component Analysis (ICA) have been proposed to remove ocular artifacts from multichannel EEG. In contrast to this, we present a new algorithm for ocular artifacts removal from a single electroencephalographic channel recording. This method is based on a set of information on brain wave frequencies. Our results on EEG data, collected from healthy subjects, show that our algorithm can effectively detect and remove ocular artifacts in EEG recordings.