Sydney Gales
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Sydney Gales has a total of 114 co-authors. Here are the top co-authors by number of shared publications:
- A. Leatherland
Atomic Weapons Establishment, Aldermaston, Berkshire RG7 4PR, United Kingdom
7 shared publications - Alex B. Zylstra
Pacific Fusion Corporation 3 , Fremont, California 94538
5 shared publications C. J. Horsfield
Atomic Weapons Establishment, Aldermaston, Berkshire RG7 4PR, United Kingdom
5 shared publicationsH. W. Herrmann
Los Alamos National Laboratory 1 , Los Alamos, New Mexico 87545, USA
4 shared publications- Hermann Geppert-Kleinrath
Los Alamos National Laboratory, Los Alamos, New Mexico 87545, USA
4 shared publications J. D. Kilkenny
General Atomics, San Diego, California 92186, USA
4 shared publications
Latest Publications
- 1 June 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (6)
Platform for 100 s Mbar equation of state measurements on the National Ignition Facility
Equation of state (EOS) measurements in the 100 s Mbar range are needed to underwrite models employed in the simulation of high energy density plasmas. To this end, a platform has been developed for fielding on the National Ignition Facility, capable of producing high-quality impedance match EOS data, wherein a planar, high-pressure, steady shock is driven into a sample package, and sample and reference standard shock velocities are measured. This platform, dubbed planar high pressure, or PHP, was fielded with an initial proof-of-concept shot in January 2023. The first PHP shot, aiming to study gold, demonstrated a pressure close to 400 Mbar, two orders of magnitude higher than previously reported gold EOS data.
- 1 June 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (6)
Platform for 100 s Mbar equation of state measurements on the National Ignition Facility
Equation of state (EOS) measurements in the 100 s Mbar range are needed to underwrite models employed in the simulation of high energy density plasmas. To this end, a platform has been developed for fielding on the National Ignition Facility, capable of producing high-quality impedance match EOS data, wherein a planar, high-pressure, steady shock is driven into a sample package, and sample and reference standard shock velocities are measured. This platform, dubbed planar high pressure, or PHP, was fielded with an initial proof-of-concept shot in January 2023. The first PHP shot, aiming to study gold, demonstrated a pressure close to 400 Mbar, two orders of magnitude higher than previously reported gold EOS data.
- 1 January 2021
- Published by AIP Publishing in Physics of Plasmas
- Vol. 28 (1) , 012707
First observation of increased DT yield over prediction due to addition of hydrogen
In a number of reported instances, implosions utilizing fuel mixtures have resulted in anomalously low fusion yields below those predicted by radiation-hydrodynamics simulations. Inter-species ion diffusion has been suggested as a possible cause of the observed yield degradation in fuel mixture implosions. An experimental platform utilizing hydro-equivalent deuterium–tritium (DT), deuterium–tritium–hydrogen (DTH), and deuterium-tritium-helium3 (DT3He) capsule implosions was developed to determine whether the inter-species ion diffusion theory may describe the resulting fuel mixture implosion behavior. The implosion experiments were performed at the Omega laser facility. X-ray images and shell areal density diagnostics results show that the hydro-equivalent three capsules (DT, DTH, and DT3He) have similar compression behavior. However, nuclear yield deviation was observed from the scaling determined using a fusion yield formula. In the DT3He mixture, a reduced yield of a factor of 0.65 ± 0.13 was observed, which is similar to a yield reduction observed in D3He mixture by Rygg et al. (i.e., Rygg effect). In contrast, in the DTH mixture, a factor of 1.17 ± 0.15 yield increase was observed, which we named the inverse Rygg effect. The yield increase observed in the DTH mixture is consistent with the inter-species ion diffusion theory where lighter H diffuses away from the core and concentrated DT in the core produces higher yield. An inter-species ion diffusion model, the Zimmerman–Paquette–Kagan–Zhdanov model, implemented in a Lagrangian radiation-hydrodynamics fluid code, was also used to analyze the present data, without the need to assume hydrodynamic equivalence of the capsules, but it does not completely explain the DTH or DT3He capsules although its effects are in the correct direction. Simulation-based Bayesian inference was used in the latter analysis to quantify the uncertainty in the numerical simulations. The simulation-based analysis resulted in an inferred Rygg-effect yield decrease factor of 0.91 ± 0.02 for the DT3He mixture, and an inferred inverse-Rygg yield increase factor of 1.21 ± 0.04 for the DTH mixture, based on simulations ignoring ion diffusion.
- 1 January 2021
- Published by AIP Publishing in Physics of Plasmas
- Vol. 28 (1) , 012707
First observation of increased DT yield over prediction due to addition of hydrogen
In a number of reported instances, implosions utilizing fuel mixtures have resulted in anomalously low fusion yields below those predicted by radiation-hydrodynamics simulations. Inter-species ion diffusion has been suggested as a possible cause of the observed yield degradation in fuel mixture implosions. An experimental platform utilizing hydro-equivalent deuterium–tritium (DT), deuterium–tritium–hydrogen (DTH), and deuterium-tritium-helium3 (DT3He) capsule implosions was developed to determine whether the inter-species ion diffusion theory may describe the resulting fuel mixture implosion behavior. The implosion experiments were performed at the Omega laser facility. X-ray images and shell areal density diagnostics results show that the hydro-equivalent three capsules (DT, DTH, and DT3He) have similar compression behavior. However, nuclear yield deviation was observed from the scaling determined using a fusion yield formula. In the DT3He mixture, a reduced yield of a factor of 0.65 ± 0.13 was observed, which is similar to a yield reduction observed in D3He mixture by Rygg et al. (i.e., Rygg effect). In contrast, in the DTH mixture, a factor of 1.17 ± 0.15 yield increase was observed, which we named the inverse Rygg effect. The yield increase observed in the DTH mixture is consistent with the inter-species ion diffusion theory where lighter H diffuses away from the core and concentrated DT in the core produces higher yield. An inter-species ion diffusion model, the Zimmerman–Paquette–Kagan–Zhdanov model, implemented in a Lagrangian radiation-hydrodynamics fluid code, was also used to analyze the present data, without the need to assume hydrodynamic equivalence of the capsules, but it does not completely explain the DTH or DT3He capsules although its effects are in the correct direction. Simulation-based Bayesian inference was used in the latter analysis to quantify the uncertainty in the numerical simulations. The simulation-based analysis resulted in an inferred Rygg-effect yield decrease factor of 0.91 ± 0.02 for the DT3He mixture, and an inferred inverse-Rygg yield increase factor of 1.21 ± 0.04 for the DTH mixture, based on simulations ignoring ion diffusion.
- 1 October 2018
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 89 (10) , 10I148
Progress on next generation gamma-ray Cherenkov detectors for the National Ignition Facility
Fusion reaction history and ablator areal density measurements for Inertial Confinement Fusion experiments at the National Ignition Facility are currently conducted using the Gamma Reaction History diagnostic (GRH_6m). Future Gas Cherenkov Detectors (GCDs) will ultimately provide ∼100x more sensitivity, reduce the effective temporal response from ∼100 to ∼10 ps, and lower the energy threshold from 2.9 to 1.8 MeV, relative to GRH_6m. The first phase toward next generation GCDs consisted of inserting the existing coaxial GCD-3 detector into a reentrant well which puts it within 4 m of the implosion. Reaction history and ablator gamma measurement results from this Phase I are discussed here. These results demonstrate viability for the follow-on Phases of (II) the use of a revolutionary new pulse-dilation photomultiplier tube to improve the effective measurement bandwidth by >10x relative to current PMT technology; and (III) the design of a NIF-specific “Super” GCD which will be informed by the assessment of the radiation background environment within the well described here.
- 1 October 2018
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 89 (10) , 10I148
Progress on next generation gamma-ray Cherenkov detectors for the National Ignition Facility
Fusion reaction history and ablator areal density measurements for Inertial Confinement Fusion experiments at the National Ignition Facility are currently conducted using the Gamma Reaction History diagnostic (GRH_6m). Future Gas Cherenkov Detectors (GCDs) will ultimately provide ∼100x more sensitivity, reduce the effective temporal response from ∼100 to ∼10 ps, and lower the energy threshold from 2.9 to 1.8 MeV, relative to GRH_6m. The first phase toward next generation GCDs consisted of inserting the existing coaxial GCD-3 detector into a reentrant well which puts it within 4 m of the implosion. Reaction history and ablator gamma measurement results from this Phase I are discussed here. These results demonstrate viability for the follow-on Phases of (II) the use of a revolutionary new pulse-dilation photomultiplier tube to improve the effective measurement bandwidth by >10x relative to current PMT technology; and (III) the design of a NIF-specific “Super” GCD which will be informed by the assessment of the radiation background environment within the well described here.
- 1 October 2018
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 89 (10) , 10I146
Pulse dilation gas Cherenkov detector for ultra-fast gamma reaction history at the NIF (invited)
The Cherenkov mechanism used in Gas Cherenkov Detectors (GCDs) is exceptionally fast. However, the temporal resolution of GCDs, such as the Gamma Reaction History diagnostic at the National Ignition Facility (NIF), has been limited by the current state-of-the-art photomultiplier tube technology to ∼100 ps. The soon-to-be deployed Pulse Dilation Photomultiplier Tube (PD-PMT) at NIF will allow for temporal resolution comparable to that of the gas cell or ∼10 ps. Enhanced resolution will contribute to the quest for ignition in a crucial way through precision measurements of reaction history and ablator areal density (ρR) history, leading to better constrained models. Features such as onset of alpha heating, shock reverberations, and burn truncation due to dynamically evolving failure modes may become visible for the first time. Test measurements of the PD-PMT at Atomic Weapons Establishment confirmed that design goals have been met. The PD-PMT provides dilation factors of 2 to 40× in 6 increments. The GCD-3 recently deployed at the NIF has been modified for coupling to a PD-PMT and will soon be making ultrafast measurements.
- 1 October 2018
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 89 (10) , 10I146
Pulse dilation gas Cherenkov detector for ultra-fast gamma reaction history at the NIF (invited)
The Cherenkov mechanism used in Gas Cherenkov Detectors (GCDs) is exceptionally fast. However, the temporal resolution of GCDs, such as the Gamma Reaction History diagnostic at the National Ignition Facility (NIF), has been limited by the current state-of-the-art photomultiplier tube technology to ∼100 ps. The soon-to-be deployed Pulse Dilation Photomultiplier Tube (PD-PMT) at NIF will allow for temporal resolution comparable to that of the gas cell or ∼10 ps. Enhanced resolution will contribute to the quest for ignition in a crucial way through precision measurements of reaction history and ablator areal density (ρR) history, leading to better constrained models. Features such as onset of alpha heating, shock reverberations, and burn truncation due to dynamically evolving failure modes may become visible for the first time. Test measurements of the PD-PMT at Atomic Weapons Establishment confirmed that design goals have been met. The PD-PMT provides dilation factors of 2 to 40× in 6 increments. The GCD-3 recently deployed at the NIF has been modified for coupling to a PD-PMT and will soon be making ultrafast measurements.
- 1 October 2018
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 89 (10) , 10I137
Development of an ultra-fast photomultiplier tube for gamma-ray Cherenkov detectors at the National Ignition Facility (PD-PMT)
A new ultra-fast photomultiplier tube and associated drivers have been developed for use in the next generation of gamma-ray high pressure gas Cherenkov detectors for inertial confinement fusion experiments at the National Ignition Facility. Pulse-dilation technology has been applied to a standard micro-channel-plate-based photomultiplier tube to improve the temporal response by about 10×. The tube has been packaged suitably for deployment on the National Ignition Facility, and remote electronics have been designed to deliver the required non-linear waveforms to the pulse dilation electrode. This is achieved with an avalanche pulse generator system capable of generating fast arbitrary waveforms over the useful parameter space. The pulse is delivered via fast impedance-matching transformers and isolators, allowing the cathode to be ramped on a sub-nanosecond time scale between two high voltages in a controlled non-linear manner. This results in near linear pulse dilation over several ns. The device has a built-in fiducial system that allows easy calibration and testing with fiber optic laser sources. Results are presented demonstrating the greatly improved response time and other parameters of the device.
- 1 October 2018
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 89 (10) , 10I137
Development of an ultra-fast photomultiplier tube for gamma-ray Cherenkov detectors at the National Ignition Facility (PD-PMT)
A new ultra-fast photomultiplier tube and associated drivers have been developed for use in the next generation of gamma-ray high pressure gas Cherenkov detectors for inertial confinement fusion experiments at the National Ignition Facility. Pulse-dilation technology has been applied to a standard micro-channel-plate-based photomultiplier tube to improve the temporal response by about 10×. The tube has been packaged suitably for deployment on the National Ignition Facility, and remote electronics have been designed to deliver the required non-linear waveforms to the pulse dilation electrode. This is achieved with an avalanche pulse generator system capable of generating fast arbitrary waveforms over the useful parameter space. The pulse is delivered via fast impedance-matching transformers and isolators, allowing the cathode to be ramped on a sub-nanosecond time scale between two high voltages in a controlled non-linear manner. This results in near linear pulse dilation over several ns. The device has a built-in fiducial system that allows easy calibration and testing with fiber optic laser sources. Results are presented demonstrating the greatly improved response time and other parameters of the device.
- 1 August 2018
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 89 (8) , 083510
First measurements of remaining shell areal density on the OMEGA laser using the Diagnostic for Areal Density (DAD)
A glass Cherenkov detector, called the Diagnostic for Areal Density (DAD), has been built and implemented at the OMEGA laser facility for measuring fusion gammas above 430 keV, from which remaining shell ⟨ρR⟩abl can be determined. A proof-of-principle experiment is discussed, where signals from a surrogate gas Cherenkov detector are compared with reported values from the wedge range filter and charged particle spectrometer and found to correlate strongly. The design of the more compact port–based DAD diagnostic and results from the commissioning shots are then presented. Once absolutely calibrated, the DAD will be capable of reporting remaining shell ⟨ρR⟩abl for plastic and glass capsules within minutes of a shot and with potentially higher precision than existing techniques.
- 1 August 2018
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 89 (8) , 083510
First measurements of remaining shell areal density on the OMEGA laser using the Diagnostic for Areal Density (DAD)
A glass Cherenkov detector, called the Diagnostic for Areal Density (DAD), has been built and implemented at the OMEGA laser facility for measuring fusion gammas above 430 keV, from which remaining shell ⟨ρR⟩abl can be determined. A proof-of-principle experiment is discussed, where signals from a surrogate gas Cherenkov detector are compared with reported values from the wedge range filter and charged particle spectrometer and found to correlate strongly. The design of the more compact port–based DAD diagnostic and results from the commissioning shots are then presented. Once absolutely calibrated, the DAD will be capable of reporting remaining shell ⟨ρR⟩abl for plastic and glass capsules within minutes of a shot and with potentially higher precision than existing techniques.
- 11 July 2018
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 89 (10) , 10I103
Cherenkov detector analysis for implosions with multiple nuclear reactions
Nuclear reactions that produce γ rays occur in inertial fusion implosions and are commonly measured with Cherenkov detectors. Typically a detector is primarily sensitive to a single reaction, but in some implosions, multiple fusion reactions can occur and are combined in the data. We discuss an analysis technique using multiple thresholded detectors to reproduce the individual burn histories from reactions like DT and HT fusion, which is applicable to separated-reactant mix experiments. Requirements for this technique and resulting analysis uncertainties are quantified using synthetic data.
- 11 July 2018
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 89 (10) , 10I103
Cherenkov detector analysis for implosions with multiple nuclear reactions
Nuclear reactions that produce γ rays occur in inertial fusion implosions and are commonly measured with Cherenkov detectors. Typically a detector is primarily sensitive to a single reaction, but in some implosions, multiple fusion reactions can occur and are combined in the data. We discuss an analysis technique using multiple thresholded detectors to reproduce the individual burn histories from reactions like DT and HT fusion, which is applicable to separated-reactant mix experiments. Requirements for this technique and resulting analysis uncertainties are quantified using synthetic data.
- 1 June 2018
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 89 (6) , 063506
Characterisation of a sub-20 ps temporal resolution pulse dilation photomultiplier tube
A pulse-dilation photomultiplier tube (PD-PMT) with sub-20 ps temporal resolution has been developed for use with γ-ray-sensitive gas Cherenkov detectors at the National Ignition Facility to improve the diagnosis of nuclear fusion burn history and the areal density of the remaining capsule ablator. The pulse-dilation mechanism entails the application of a time-dependent, ramp waveform to a photocathode-mesh structure, introducing a time-dependent photoelectron accelerating potential. The electric field imparts axial velocity dispersion to outgoing photoelectrons. The photoelectron pulse is dilated as it transits a drift region prior to amplification in a microchannel plate and read out with a digital oscilloscope. We report the first measurements with the prototype PD-PMT demonstrating nominal <20 ps FWHM across a 400 ps measurement window and <30 ps FWHM for an extracted charge up to 300 pC. The output peak areas are linear to within 20% over 3 orders of magnitude of input intensity. 3D particle in cell simulations, which included space charge effects, have been carried out to investigate the device temporal magnification, resolution, and linearity.
- 1 June 2018
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 89 (6) , 063506
Characterisation of a sub-20 ps temporal resolution pulse dilation photomultiplier tube
A pulse-dilation photomultiplier tube (PD-PMT) with sub-20 ps temporal resolution has been developed for use with γ-ray-sensitive gas Cherenkov detectors at the National Ignition Facility to improve the diagnosis of nuclear fusion burn history and the areal density of the remaining capsule ablator. The pulse-dilation mechanism entails the application of a time-dependent, ramp waveform to a photocathode-mesh structure, introducing a time-dependent photoelectron accelerating potential. The electric field imparts axial velocity dispersion to outgoing photoelectrons. The photoelectron pulse is dilated as it transits a drift region prior to amplification in a microchannel plate and read out with a digital oscilloscope. We report the first measurements with the prototype PD-PMT demonstrating nominal <20 ps FWHM across a 400 ps measurement window and <30 ps FWHM for an extracted charge up to 300 pC. The output peak areas are linear to within 20% over 3 orders of magnitude of input intensity. 3D particle in cell simulations, which included space charge effects, have been carried out to investigate the device temporal magnification, resolution, and linearity.
- 2 June 2010
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1238 (1) , 349-351
LHCf: calibration of hadron interaction models for high energy cosmic-ray physics at the LHC energy
LHCf measures the energy and transverse momentum of neutral particles produced in the forward region of the LHC interaction point. In high energy cosmic ray measurements, the results strongly depend on the hadron interaction model which is used in the air shower simulation. LHCf will take data at 2.4, 7, 10 and 14 TeV collisions at LHC and provide crucial calibration points for the hadron interaction models.- 2 June 2010
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1238 (1) , 349-351
LHCf: calibration of hadron interaction models for high energy cosmic-ray physics at the LHC energy
LHCf measures the energy and transverse momentum of neutral particles produced in the forward region of the LHC interaction point. In high energy cosmic ray measurements, the results strongly depend on the hadron interaction model which is used in the air shower simulation. LHCf will take data at 2.4, 7, 10 and 14 TeV collisions at LHC and provide crucial calibration points for the hadron interaction models.- 1 March 2003
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 74 (3) , 2220-2223
Investigation into the aging effect of experiment use on x-ray diode photocathodes, and the calibration of p-i-n silicon diodes
Vacuum x-ray diode photocathodes are commonly employed in temperature diagnostic instruments on the Helen laser at AWE Aldermaston, UK. The photocathodes are used in a Dante filtered x-ray diode spectrometer and in conjunction with a compound x-ray filter to yield a quasi-flat response detector the flat response diode. Investigations carried out in 1999 indicated that the response of these photocathodes diminished over time. Following these investigations [C. D. Bentley and A. C. Simmons, Rev. Sci. Instrum. 72, 1202 (2001)] a number of refurbished photocathodes were produced and the effect of their use in the above instruments investigated. Initial characterization was carried out using the hot cathode Excalibur soft x-ray calibration facility at AWE and at the National Synchrotron Light Source (NSLS) at Brookhaven. Diode sensitivity was remeasured 14 months later again at Brookhaven and at AWE. These results are compared with the earlier study and some degradation in sensitivity is noted. Possible reasons for this change are discussed. Additionally in the latest study the sensitivity of a number of silicon p-i-n diodes was measured at the NSLS and at AWE. The different detector characteristics demand different approaches and these are discussed. Sensitivity results are presented and compared.
- 1 March 2003
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 74 (3) , 2220-2223
Investigation into the aging effect of experiment use on x-ray diode photocathodes, and the calibration of p-i-n silicon diodes
Vacuum x-ray diode photocathodes are commonly employed in temperature diagnostic instruments on the Helen laser at AWE Aldermaston, UK. The photocathodes are used in a Dante filtered x-ray diode spectrometer and in conjunction with a compound x-ray filter to yield a quasi-flat response detector the flat response diode. Investigations carried out in 1999 indicated that the response of these photocathodes diminished over time. Following these investigations [C. D. Bentley and A. C. Simmons, Rev. Sci. Instrum. 72, 1202 (2001)] a number of refurbished photocathodes were produced and the effect of their use in the above instruments investigated. Initial characterization was carried out using the hot cathode Excalibur soft x-ray calibration facility at AWE and at the National Synchrotron Light Source (NSLS) at Brookhaven. Diode sensitivity was remeasured 14 months later again at Brookhaven and at AWE. These results are compared with the earlier study and some degradation in sensitivity is noted. Possible reasons for this change are discussed. Additionally in the latest study the sensitivity of a number of silicon p-i-n diodes was measured at the NSLS and at AWE. The different detector characteristics demand different approaches and these are discussed. Sensitivity results are presented and compared.