MTMakbule Tuğba Tunçdemir

Makbule Tuğba Tunçdemir

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Makbule Tuğba Tunçdemir has a total of 26 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Comparison of Body Position Perception, Tongue Pressure and Neck Muscle Endurance in Patients with Bruxism and Temporomandibular Joint Dysfunction: Occlusal Splint Users and Non-Users

    by Beyza Çiçek, Neslihan Altuntaş Yılmaz, Makbule Tuğba Tunçdemir, Fatma Erdeo

    Background: This study aimed to investigate the association between occlusal splint use and several key parameters, including body position perception, tongue pressure, temporomandibular joint dysfunction (TMD) severity, jaw functional limitation, and neck muscle endurance. Methods: A total of 157 individuals diagnosed with bruxism were screened, and 52 eligible participants were enrolled and divided into two groups: occlusal splint users (n = 26) and non-users (n = 26). Body position perception was assessed with a digital inclinometer, tongue pressure was measured using the Iowa Oral Performance Instrument (IOPI), and neck muscle endurance was evaluated by the Cranio-Cervical Flexion Test (CCFT). TMD severity and jaw functional limitation were assessed via the Fonseca Anamnestic Questionnaire and Jaw Functional Limitation Scale-20, respectively. Gender-based analyses showed higher TMD severity and mandibular limitation scores in females using occlusal splints than in males. Results: No statistically significant differences were found between the splint and non-splint groups in body position perception, tongue pressure and neck muscle endurance (p > 0.05). However, significant differences were observed in the Jaw Functional Limitation Scale (CFKS) subscales. Splint users reported higher functional limitations in chewing, mobility, and expression compared to non-splint users (all p = 0.000), with small effect sizes (d = 0.23–0.29). Conclusions: Occlusal splint use was not associated with better proprioception, orofacial muscle function, or TMD-related symptoms compared with non-splint users. However, splint users were associated with higher mandibular functional limitation based on CFKS subscale scores.

  • Open Access

    Examination of stress distribution on Class I cavity restored using amalgam and bulk-fill composite: A 3D finite element stress analysis

    by Hilal Karaköy, Hakan Yasin Gönder, Reza Mohammadi, Abdulkadir Harmankaya, Makbule Tuğba Tunçdemir, Emine Gülşah Göktolga

    Aim: The aim of this study was to examine the stress distribution on the tooth structure, restorative materials, and periodontal tissues prepared in a computer environment as a result of the forces acting on the mandibular premolar tooth surface, using the finite element stress analysis method. Methodology: The extracted mandibular premolar tooth was scanned with a dental tomography device and recorded. Images were obtained as digital imaging and communications in medicine (DICOM) files, which were transferred to the Mimics 12.00 program. This program was used to create a 3D image of the tooth, which was converted into a Standard Tessellation Language (STL) file. The resulting STL files were transferred to the Geomagic Design X program, some necessary adjustments, such as smoothing, were made, and Standard for the Exchange of Product Model Data (STP) files were created. The STP files were transferred to the SolidWorks program and Class I cavity preparation, restorative material layers, adhesive material layers, and periodontal tissues were created. Finally, the finite element (FE) model was created in the ABAQUS program, and the stress distributions were analyzed. Results: In the model restored with bulk-fill, compared to the model restored with amalgam, the amount of stress on dentin was found to be higher, while the amount of stress on cortical bone, trabecular bone, periodontal ligament, and enamel was found to be lower. In both models restored with bulk-fill composite and amalgam, the structure exposed to the most stress was the enamel layer, while the structure exposed to the least stress was the periodontal ligament. The amount of stress on the amalgam material was found to be higher than the amount of stress on the bulk-fill composite material. Conclusion: Amalgam and bulk-fill composite materials are frequently used today in posterior teeth with large cavities. As a result of our study, bulk-fill composite material caused less stress distribution than amalgam in all tissues except dentin tissue. How to cite this article: Karaköy H, Gönder HY, Mohammadi R, Harmankaya A, Tunçdemir MT, Yüksel İB, Göktolga EG. Examination of stress distribution on Class I cavity restored using amalgam and bulk-fill composite: A 3D finite element stress analysis. Int Dent Res. 2024;14(S1):98-105. https://doi.org/10.5577/indentres.570

  • Open Access

    Examination of stress distributions on Class V restorations using nanohybrid resin composite: A 3D finite element stress analysis

    by Abdulkadir Harmankaya, Hakan Yasin Gönder, Reza Mohammadi, Hilal Karaköy, Makbule Tuğba Tunçdemir, İbRahim Burak Yüksel, Emine Gülşah Göktolga

    Aim: The aim of this study was to investigate and compare the distribution of stress zones in composite resins and dental tissues applied to different-sized Class V cavities in the cervical region of the tooth as a result of the forces acting on the tooth in a computer environment using the finite element method. Methodology: The extracted lower first molar tooth was scanned and recorded with a dental tomography device. Images were obtained as DICOM files, and these files were imported into the Mimics 12.00 program. In this program, a 3D image of the tooth was created and converted to Standard Tessellation Language (STL) files. The obtained STL files were transferred to the Geomagic Design X program, and Standard for the Exchange of Product Model Data (STP) files were created. The SolidWorks program was used to create different sizes of Class V cavity preparation, restorative material layers, adhesive material layers, and periodontal tissues. Finally, a finite element (FE) model was created in the ABAQUS program, and stress distributions were analyzed. Results: When the depth was kept constant and the width was increased, the amount of stress on the enamel tissue decreased, while the amount of stress on all other tissues and the restorative material increased. When the width was kept constant and the depth was increased, the amount of stress on the restorative material, adhesive layer, and cortical bone increased, while the amount of stress on the enamel layer, dentin layer, periodontal ligament, and trabecular bone decreased. Conclusion: Based on the values found in the study, the model that produced the least stress on the restorative material was the model with the least depth and width. However, the stress accumulation in the enamel tissue was higher in this model compared to the other models. As a result, the lifespan of restorative materials may be longer in cavities prepared more shallowly and narrowly during the preparation phase. How to cite this article: Harmankaya A, Gönder HY, Mohammadi R, Karaköy H, Tunçdemir MT, Yüksel İB, Göktolga EG. Examination of stress distributions on Class V restorations using nanohybrid resin composite: A 3D finite element stress analysis. Int Dent Res. 2024;14(S1):90-97. https://doi.org/10.5577/indentres.562

  • Open Access

    The effect of different herbal teas on the color stability of nanohybrid and bulk-fill composites

    by Makbule Tuğba Tunçdemir, Zeynep Dereli, Ayşe Bahar

    Aim: The aim of this study is to investigate the effects of green tea and rosehip tea, on the color stability of nanohybrid and bulk-fill composite resins. Methodology: A total of 60 disc-shaped samples were made from two types of A2 resin with nanohybrid (Tetric N Ceram, Ivoclar Vivadent, Schaan, Liechtenstein) and bulk-fill (Filtek Bulk-Fill, 3M ESPE, MN, USA) structure with the help of 10 mm diameter and 2 mm thick Teflon molds in this study. All samples were finished and polished with 4-stage (thick, medium, fine, superfine) polishing discs (Sof-lex, 3M ESPE, MN, USA) and kept in an oven at 37 °C for 24 hours. The samples, whose initial color measurements were made by spectrophotometer, were divided into subgroups for the control group and two different herbal teas (Green tea, Rosehip) (n=10). Color measurements were repeated, and ΔE values were calculated. Wilcoxon, Kruskal-Wallis, and Bonferroni tests were used to analyze the data (p < 0.05). Results: There was no statistically significant difference in color change between the composite resins (p > 0.05). No significant color change was found for either the Tetric N-Ceram or Filtek Bulk-Fill composite resin samples immersed in distilled water (p > 0.05, ΔEConclusion: Rosehip and green tea affect the color stability of composite resin restorations. Whereas the color change caused by green tea is at a clinically acceptable level, that stemming from rosehip tea falls within clinically unacceptable levels.   How to cite this article: Tunçdemir MT, Dereli Z, Bahar A. The effect of different herbal teas on the color stability of nanohybrid and bulk-fill composites. Int Dent Res 2022;12(Suppl.1):103-7. https://doi.org/10.5577/intdentres.445 Linguistic Revision: The English in this manuscript has been checked by at least two professional editors, both native speakers of English.


  • Open Access

    Investigation of the coloring effects of different ground-based coffee types on composite resin materials

    by Meryem Erdoğdu, Makbule Tuğba Tunçdemir, Neslihan Güntekin

    Aim: The aim of this study is to investigate the effect of different ground-based coffee types on the color change of nanohybrid and bulk-fill composites. Methodology: A total of 80 disk-shaped samples were made using Teflon molds (5 mm in diameter and 8 mm thick) and two types of A2 resin with nanohybrid (Tetric N Ceram Ivoclar Vivadent, Schaan, Liechtenstein) and bulk-fill (Filtek Bulk-Fill, 3M ESPE, St. Paul, MN, USA) structures. All samples were finished and polished with four-stage (thick, medium, fine, and superfine) polishing disks (Sof-lex, 3M ESPE, St. Paul, MN, USA) and kept at 37°C for 24 hours. Color measurements of the samples were performed using a spectrophotometer (Vita Easy Shade, Vita ZahnFabrik, Bad Sackingen, Germany) and were divided into subgroups: the control group, filter coffee, Turkish coffee, espresso, and Mırra (n = 8). Distilled water was used as a control. Prepared coffees were added to the microcentrifuge tubes and refreshed daily during the 14-day exposure period. ΔE values were calculated for each material. Statistical analyses were performed using one-way variance analysis and Tukey multiple comparisons (p = 0.05). Results: There was no significant color change for either the nano-fill or bulk-fill composite groups in the control group samples (p>0.05). Filter coffee was found to be the most effective colorant coffee type for both composites (p < 0.05). Among the coffee types, Mırra caused the least coloration for both composites. Conclusion: The consumption of two or more cups of coffee per day, especially filter coffee, can cause color changes in both conventional and bulk-fill composites, and it should be considered an important factor in aesthetic problems with dental restorations. How to cite this article: Erdoğdu M, Tunçdemir MT, Güntekin N. Investigation of the coloring effects of different ground-based coffee types on composite resin materials. Int Dent Res 2022;12(Suppl.1):16-21. https://doi.org/10.5577/intdentres.448 Linguistic Revision: The English in this manuscript has been checked by at least two professional editors, both native speakers of English.


  • Open Access

    The effect of the material used and the pulp chamber extension depth on stress distribution of endocrowns: A three-dimensional finite element analysis

    by Neslihan Güntekin, Reza Mohammadi, Makbule Tuğba Tunçdemir

    Aim: The aim of this study was to examine the effects of materials used and the depth of extension into the pulp chamber on stress distribution in mandibular molar endodontically treated teeth with endocrown restoration using three-dimensional (3D) finite element analysis (FEA). Methodology: Three-dimensional finite element analysis models were obtained at two different pulp chamber extension depths by taking a tomography of a root canal-treated mandibular molar tooth extracted for periodontal reasons: 2.5 mm (Model A) and 3.5 mm (Model B). Models were divided into the following three groups according to material type used: Vita Enamic (VE), Lava Ultimate (LU), and IPS e.max CAD (EMX). The aforementioned model groups were further divided into the following two subgroups according to the types of cement used: NX3 and MaxCem Elite Chroma (MX). Maximum principal stress (MPa) values under 600 N vertical load were investigated to evaluate the effect of restoration design, material type, and cements used on stress distribution. Results: The maximum stress on the restoration was observed in the EMX material type (13.000 MPa) in the MX cement group in Model A, while the lowest was observed in the LU material (5.932 MPa) in the NX3 cement group in Model A. The areas of highest stress for both Models A and B were observed in the restoration areas corresponding to the enamel margins. Conclusion: Materials with a higher elastic modulus show a higher stress area on the restoration surface, while the stress values they transmit are lower. Materials with the elastic modulus close to dentin have more homogeneous stress distributions within the restoration. How to cite this article: Güntekin N, Mohammadi R, Tunçdemir MT. The effect of the material used and the pulp chamber extension depth on stress distribution of endocrowns: A three-dimensional finite element analysis. Int Dent Res 2022;12(Suppl.1):1-9. https://doi.org/10.5577/intdentres.436 Linguistic Revision: The English in this manuscript has been checked by at least two professional editors, both native speakers of English.


  • Direkt Kompozit Rezin Restorasyonla Estetik Kaygının Giderilmesi, 36 Aylık Takip

    by Makbule Tuğba TUNCDEMIR, İrem Elmaci

    Son yıllarda koruyucu ve estetik restoratif diş hekimliğindeki gelişmelerle bugüne kadar çoğunlukla protetik uygulamalarla giderilen yapı, şekil ve renk bozuklukları adeziv teknikler ile tek seansta tedavi edilebilmektedir. Özellikle adeziv sistemler ve kompozit rezinlerdeki gelişmelerle daha konservatif, ekonomik bir yaklaşımla ve protetik işlemlere kıyasla çok daha kısa sürede estetik kaygılar giderilebilmektedir. Direkt kompozit rezinler doğru teknikle uygulandıklarında tatmin edici estetik sonuçlar alınabilmektedir. Bu olguda, 22 numaralı dişin restorasyonunun kaybı üzerine kliniğimize başvuran hastaya nanohibrit kompozit rezin (Sirona Ceram.x ,Dentsply) ile tek seansta direkt kompozit rezin restorasyon uygulanmıştır. Hastanın 18. ve 36. ay takipleri yapılmış ve değerlendirilmiştir.

  • Open Access

    Investigation of the Effect of Whitening Mouthwashes on the Translucency of Resin Composites at Different Times

    by Muhammet Fidan, Makbule Tugba Tuncdemir

    The aim of this study is to evaluate the effect of whitening mouthwashes on the translucency parameter (TP) at different times of resin composites after coloring with coffee. A total of 90 samples were prepared from resin materials (Estelite Σ Quick, G-aenial Anterior, Omnichroma). After being kept in coffee for 12 days, the samples were divided into three subgroups (n = 10). The initial (T0) measurement of the TP values was recorded. Control groups were kept in distilled water, and the other groups were kept in two different types of mouthwash (Listerine Advanced White and Crest 3D White). The TP values were recorded at the end of 24 h (T1) and 72 h (T2). The TP values were determined using the CIEDE2000 formula. Two-way analysis of variance and the Tukey test were used (p < 0.05). The lowest ΔTP value was observed in the control group at T0–T1 and T0–T2. The highest ΔTP value was observed with Crest 3D White mouthwash at T0–T2. However, there was no difference with Listerine Advanced White. Among the composites, the highest ΔTP value was found in G-aenial Anterior at T0–T2, and the lowest ΔTP value was found in Omnichroma at T0–T1. Whitening mouthwashes caused an increase in the translucency values of resin composites over time. It should be noted that long-term use of whitening mouthwashes may affect the translucency values of resin composites.


  • Open Access

    Analysis of Monomer Release from Different Composite Resins after Bleaching by HPLC

    by Mehmet Gökberkkaan Demirel, Hakan Yasin Gönder, Makbule Tuğba Tunçdemir

    (1) Background: This study aimed to examine the effect of bleaching agents on the release of triethylenae glycol dimethacrylate, 2-hydroxyethyl methacrylate, bisphenol A, urethane dimethacrylate, and bisphenol A-glycidyl methacrylate monomers, which are released from different composite resins, using the high-performance liquid chromatography (HPLC) method. (2) Methods: Ninety disc-shaped specimens were produced and immersed in artificial saliva. After different bleaching applications [office type bleaching (OB) and home type bleaching (HB)], the specimens were immersed in a 75 wt% ethanol/water solution, and the released monomers were analyzed by HPLC at predefined time intervals: 1, 7, and 28 days. The Kruskal–Wallis and Mann–Whitney U tests were conducted for statistical analysis (p = 0.05). (3) Results: The monomers were released at all times from all composite specimens. The monomer release was increased over time. The highest monomer release was detected on day 28. Bleaching applications affected monomer release. No statistical difference was found between OB and HB applications (p > 0.05). The most released monomer was Bisphenol-A in all composites. (4) Conclusion: Given that a residual monomer release from composite resins has a toxic effect and that bleaching treatments increase this release, a treatment protocol should be made in accordance with the manufacturer’s instructions.


  • The Relationship Between Plasma MicroRNAs and Serum Mercury Levels in Patients with Amalgam Filling and Dentists

    by Makbule Tuğba TUNCDEMIR, Fatma Hümryra Yerli̇kAya

    Background: The aim of this study was to investigate the relationship between serum mercury and some plasma microRNA (miRNA) levels associated with neurological diseases in patients with amalgam filling and dentists. Methods: This study included 30 patients with amalgam filling, 30 dentists, and 30 healthy individuals as the control group. Circulating plasma miRNAs (124-3p, 125-5p, and 127-3p) were evaluated using real-time quantitative polymerase chain reaction analysis. The serum mercury levels were measured using inductively coupled plasma-mass spectrometry. ANOVA and Tukey’s multiple comparison tests were used for statistical analyses (α =.05). Results: A significant difference in serum mercury and plasma miRNA levels was found between the groups. Significant positive correlations between serum mercury and plasma miRNA 125-5p and 127-3p levels were detected in the patient group (r: 0.56 and r: 0.39, respectively). Serum mercury and plasma miRNA-125-5p levels showed a positive correlation in the dentist group (r: 0.37). Conclusion: Having amalgam filling caused a significant increase in serum mercury and plasma miRNA levels. The presence of a positive correlation suggests that sensitivity to neurological diseases may increase because of mercury exposure. Alternative restorative materials should be preferred for amalgam filling and amalgam fillings should be replaced with other restorative materials under necessary preventions.