Kevin Piro
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Kevin Piro has a total of 51 co-authors. Here are the top co-authors by number of shared publications:
Adam Kielski
Amazon Web Services, Seattle, USA
3 shared publicationsAllan Bottemiller
Origin Medical, Kirkland, USA
3 shared publications- Gregg Cohen
Radiology and Imaging Sciences, National Institutes of Health Clinical Center, Bethesda, USA
3 shared publications - Irene Wai Yan Ma
Department of Medicine, University of Calgary, Calgary, Canada
3 shared publications James D. Nolan
Information Technology, Valley Medical Center, Renton, USA
3 shared publicationsJenn Quattrone Brown
Independent Consultant, Garland, USA
3 shared publications
Latest Publications
- 11 August 2026
- Published by Wiley in Journal of Ultrasound in Medicine
Point‐of‐Care Ultrasound Correlates of Pulmonary Capillary Wedge Pressure and Right Atrial Pressure
Objectives: Volume assessment remains a challenging bedside practice that is highly dependent on patient factors, comorbid conditions, physical exam, and point‐of‐care ultrasound (POCUS) techniques. POCUS is increasingly used to assist with diuretic decision‐making for patients with suspected volume overload. While developing evidence suggests that POCUS allows for rapid and safe evaluation of volume status, limited data exist regarding which POCUS assessments correlate best to filling pressure measurements obtained from rightheart catheterization (RHC). Methods: A single‐center observational exploratory study conducted at Oregon Health & Science University investigated POCUS volume assessment in adult patients scheduled to undergo RHC. Multiple POCUS measurements were performed directly prior to RHC in 28 patients to investigate correlations between POCUS and RHC measurements, specifically mean right atrial pressure (mRAP) and pulmonary capillary wedge pressure (PCWP). Results: POCUS measurements that correlated (either positively or negatively) with mRAP as measured by RHC included qualitative RV function assessment and tricuspid annular plane of systolic excursion (TAPSE) (r S = −0.421, p = 0.032, effect size = −0.699–0.047). Left atrial diameter measurement (r P = 0.651, p = S = 0.394, p = 0.050, effect size = 0.053–0.711), E/A ratio (r S = 0.446, p = 0.025, effect size = 0.048–0.708), total B‐line score (r S = 0.407, p = 0.031, effect size = −0.159–0.615), combined LA diameter and mitral valve inflow velocity (r P = 0.383, p = 0.044, effect size = 0.011–0.661), and combined E/e′ and E/A ratio (r P = 0.418, p = 0.027, effect size = 0.053–0.684) all correlated with PCWP. Discussion: Some correlation exists between POCUS measurements and RHC assessment of PCWP and mRAP. Larger prospective studies are needed to fully understand this correlation, particularly in the context of pre/post intervention and specific disease processes.
- 11 August 2026
- Published by Wiley in Journal of Ultrasound in Medicine
Point‐of‐Care Ultrasound Correlates of Pulmonary Capillary Wedge Pressure and Right Atrial Pressure
Objectives: Volume assessment remains a challenging bedside practice that is highly dependent on patient factors, comorbid conditions, physical exam, and point‐of‐care ultrasound (POCUS) techniques. POCUS is increasingly used to assist with diuretic decision‐making for patients with suspected volume overload. While developing evidence suggests that POCUS allows for rapid and safe evaluation of volume status, limited data exist regarding which POCUS assessments correlate best to filling pressure measurements obtained from rightheart catheterization (RHC). Methods: A single‐center observational exploratory study conducted at Oregon Health & Science University investigated POCUS volume assessment in adult patients scheduled to undergo RHC. Multiple POCUS measurements were performed directly prior to RHC in 28 patients to investigate correlations between POCUS and RHC measurements, specifically mean right atrial pressure (mRAP) and pulmonary capillary wedge pressure (PCWP). Results: POCUS measurements that correlated (either positively or negatively) with mRAP as measured by RHC included qualitative RV function assessment and tricuspid annular plane of systolic excursion (TAPSE) (r S = −0.421, p = 0.032, effect size = −0.699–0.047). Left atrial diameter measurement (r P = 0.651, p = S = 0.394, p = 0.050, effect size = 0.053–0.711), E/A ratio (r S = 0.446, p = 0.025, effect size = 0.048–0.708), total B‐line score (r S = 0.407, p = 0.031, effect size = −0.159–0.615), combined LA diameter and mitral valve inflow velocity (r P = 0.383, p = 0.044, effect size = 0.011–0.661), and combined E/e′ and E/A ratio (r P = 0.418, p = 0.027, effect size = 0.053–0.684) all correlated with PCWP. Discussion: Some correlation exists between POCUS measurements and RHC assessment of PCWP and mRAP. Larger prospective studies are needed to fully understand this correlation, particularly in the context of pre/post intervention and specific disease processes.
- Open Access
- 18 June 2026
- Published by Springer Nature in Journal of Imaging Informatics in Medicine
Considerations for Pre-deployment Planning in Point-of-Care Ultrasound Program Implementation: A HIMSS-SIIM Enterprise Imaging Community Whitepaper in Collaboration with AIUM
Point-of-care ultrasound (POCUS) provides real-time diagnostic capabilities at the bedside. Implementing a POCUS program in an institution is a highly complex process. Coordinating the imaging workflow of numerous clinical specialties requires meticulous planning and appropriate oversight. This white paper describes the best practices for the critical pre-deployment phase of program implementation, after having established POCUS program governance. Important considerations during the pre-deployment phase include goal setting, scaling POCUS workflow across clinical, educational, and technological domains, and addressing budgetary concerns and complexity of deployment strategies. This paper also discusses the role of the POCUS workflow manager software in encounter-based imaging workflow and the role of a system-wide clinical ultrasound director. Furthermore, it outlines the necessary approvals needed to ensure compliance and program success, including securing approvals from key departments such as imaging informatics, information technology, cybersecurity, supply chain operations, clinical engineering, infection prevention, legal, and billing departments. Finally, it presents a sample comprehensive project charter to guide this complex integration process from business case development, to clinical go-live, emphasizing best practices for sustained adoption.
- 18 June 2026
- Published by Springer Nature in Journal of Imaging Informatics in Medicine
Open AccessConsiderations for Pre-deployment Planning in Point-of-Care Ultrasound Program Implementation: A HIMSS-SIIM Enterprise Imaging Community Whitepaper in Collaboration with AIUM
Point-of-care ultrasound (POCUS) provides real-time diagnostic capabilities at the bedside. Implementing a POCUS program in an institution is a highly complex process. Coordinating the imaging workflow of numerous clinical specialties requires meticulous planning and appropriate oversight. This white paper describes the best practices for the critical pre-deployment phase of program implementation, after having established POCUS program governance. Important considerations during the pre-deployment phase include goal setting, scaling POCUS workflow across clinical, educational, and technological domains, and addressing budgetary concerns and complexity of deployment strategies. This paper also discusses the role of the POCUS workflow manager software in encounter-based imaging workflow and the role of a system-wide clinical ultrasound director. Furthermore, it outlines the necessary approvals needed to ensure compliance and program success, including securing approvals from key departments such as imaging informatics, information technology, cybersecurity, supply chain operations, clinical engineering, infection prevention, legal, and billing departments. Finally, it presents a sample comprehensive project charter to guide this complex integration process from business case development, to clinical go-live, emphasizing best practices for sustained adoption.
- 8 September 2025
- Published by Wiley in Journal of Ultrasound in Medicine
- Vol. 45 (2) , 225-239
Point‐of‐Care Ultrasound in Hospital Medicine
Point‐of‐care ultrasound (POCUS) is increasingly used in hospital medicine to support bedside diagnosis, management, and procedural safety. This narrative review aims to synthesize current evidence on POCUS applications in pneumonia, heart failure, deep vein thrombosis, and bedside procedures. While POCUS may be clinically useful for such use cases, its broader adoption is limited by training gaps, infrastructure constraints, and credentialing challenges. Standardizing curricula and institutional support are critical next steps to optimize POCUS adoption and impact. Broader implementation of POCUS may enhance diagnostic accuracy and care efficiency in inpatient settings.
- 8 September 2025
- Published by Wiley in Journal of Ultrasound in Medicine
- Vol. 45 (2) , 225-239
Point‐of‐Care Ultrasound in Hospital Medicine
Point‐of‐care ultrasound (POCUS) is increasingly used in hospital medicine to support bedside diagnosis, management, and procedural safety. This narrative review aims to synthesize current evidence on POCUS applications in pneumonia, heart failure, deep vein thrombosis, and bedside procedures. While POCUS may be clinically useful for such use cases, its broader adoption is limited by training gaps, infrastructure constraints, and credentialing challenges. Standardizing curricula and institutional support are critical next steps to optimize POCUS adoption and impact. Broader implementation of POCUS may enhance diagnostic accuracy and care efficiency in inpatient settings.
- Open Access
- 3 January 2025
- Published by Springer Nature in Journal of Imaging Informatics in Medicine
- Vol. 38 (5) , 2585-2599
Governance Considerations for Point-of-Care Ultrasound: a HIMSS-SIIM Enterprise Imaging Community Whitepaper in Collaboration with AIUM
Point-of-care ultrasound (POCUS) has emerged as a standard of care across a variety of healthcare settings due to its ability to provide critical clinical information and as well as procedural guidance to clinicians directly at the bedside. Implementation of enterprise imaging (EI) strategies is needed such that POCUS images can be appropriately captured, indexed, managed, stored, distributed, viewed, and analyzed. Because of its unique workflow and educational requirements, reliance on traditional order-based workflow solutions may be insufficient. To improve patient care outcomes and operational efficiency, a robust governance committee for POCUS within healthcare systems that addresses pertinent institutional policies to ensure effective and sustainable implementation of enterprise imaging, appropriate to the specific clinical encounter-based workflow needs of POCUS, is critical. This white paper explores several key governance considerations in the formulation and structure of a POCUS enterprise imaging strategy, focusing on program governance, clinical governance, technology governance, information governance, and financial governance.
- 3 January 2025
- Published by Springer Nature in Journal of Imaging Informatics in Medicine
- Vol. 38 (5) , 2585-2599
Open AccessGovernance Considerations for Point-of-Care Ultrasound: a HIMSS-SIIM Enterprise Imaging Community Whitepaper in Collaboration with AIUM
Point-of-care ultrasound (POCUS) has emerged as a standard of care across a variety of healthcare settings due to its ability to provide critical clinical information and as well as procedural guidance to clinicians directly at the bedside. Implementation of enterprise imaging (EI) strategies is needed such that POCUS images can be appropriately captured, indexed, managed, stored, distributed, viewed, and analyzed. Because of its unique workflow and educational requirements, reliance on traditional order-based workflow solutions may be insufficient. To improve patient care outcomes and operational efficiency, a robust governance committee for POCUS within healthcare systems that addresses pertinent institutional policies to ensure effective and sustainable implementation of enterprise imaging, appropriate to the specific clinical encounter-based workflow needs of POCUS, is critical. This white paper explores several key governance considerations in the formulation and structure of a POCUS enterprise imaging strategy, focusing on program governance, clinical governance, technology governance, information governance, and financial governance.
- Open Access
- 15 November 2024
- Published by Queen's University Library in POCUS Journal
- Vol. 9 (2) , 93-101
Just In Time! Assessment of Internal Medicine Resident Point of Care Ultrasound (POCUS) Attitudes and Behaviors After Spaced Intervention at Two Residency Programs
Point of care ultrasound (POCUS) is a complex psychomotor skill that requires scaffolded support for skill acquisition. However, the effect of spaced curricular elements on learner POCUS behaviors are not clearly understood. Using a multi-site observational cross-sectional survey study, we measured resident baseline POCUS use, behaviors, and attitudes and then implemented POCUS workflow and just-in-time POCUS curricula during internal medicine resident ward rotations and assessed changes. Self-reported personal and team POCUS use and documentation habits all improved between baseline and the just-in-time teaching. Personal POCUS use correlated with team POCUS use (ρ=0.431; p<0.001) and co-resident POCUS use (ρ=0.242; p=0.035). Attending POCUS use correlated with team POCUS use (ρ=0.523; p< 0.001), but not personal use. Overall, we found moderate, but statistically significant, improvements in reported resident and team performance of POCUS and documentation habits, suggesting that just-in-time interventions may promote POCUS use. Co-learning also appears to be a key influencer for POCUS use.
- 15 November 2024
- Published by Queen's University Library in POCUS Journal
- Vol. 9 (2) , 93-101
Open AccessJust In Time! Assessment of Internal Medicine Resident Point of Care Ultrasound (POCUS) Attitudes and Behaviors After Spaced Intervention at Two Residency Programs
Point of care ultrasound (POCUS) is a complex psychomotor skill that requires scaffolded support for skill acquisition. However, the effect of spaced curricular elements on learner POCUS behaviors are not clearly understood. Using a multi-site observational cross-sectional survey study, we measured resident baseline POCUS use, behaviors, and attitudes and then implemented POCUS workflow and just-in-time POCUS curricula during internal medicine resident ward rotations and assessed changes. Self-reported personal and team POCUS use and documentation habits all improved between baseline and the just-in-time teaching. Personal POCUS use correlated with team POCUS use (ρ=0.431; p<0.001) and co-resident POCUS use (ρ=0.242; p=0.035). Attending POCUS use correlated with team POCUS use (ρ=0.523; p< 0.001), but not personal use. Overall, we found moderate, but statistically significant, improvements in reported resident and team performance of POCUS and documentation habits, suggesting that just-in-time interventions may promote POCUS use. Co-learning also appears to be a key influencer for POCUS use.
- 25 September 2024
- Published by Elsevier in Medical Clinics of North America
- Vol. 109 (1) , 177-189
Intestinal Ultrasound in Common Gastrointestinal Disorders
- 25 September 2024
- Published by Elsevier in Medical Clinics of North America
- Vol. 109 (1) , 177-189
Intestinal Ultrasound in Common Gastrointestinal Disorders
- 1 January 2022
- Published by Springer Nature
- p. 175-207
Ultrasound of the Urinary System
- 26 June 2018
- Published by Springer Nature
- p. 197-202
Anuria Evaluation