KPKevin Piro

Kevin Piro

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Kevin Piro has a total of 51 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Correction: Considerations for Pre-deployment Planning in Point-of-Care Ultrasound Program Implementation: A HIMSS-SIIM Enterprise Imaging Community Whitepaper in Collaboration with AIUM

    by Allan Bottemiller, Robinson M. Ferre, Les R. Folio, Michael Toland, Jeremy S. Boyd, Kevin Piro, Adam Kielski, Teashia French, Alyssa Abo, Stephanie Bazinet, et al.

  • Point‐of‐Care Ultrasound Correlates of Pulmonary Capillary Wedge Pressure and Right Atrial Pressure

    by Aaron M. Silver, Michael Armstrong, Jean Sabile, Sanket Gokhale, Patricia A. Carney, Kevin M. Piro

    Objectives: Volume assessment remains a challenging bedside practice that is highly dependent on patient factors, comorbid conditions, physical exam, and point‐of‐care ultrasound (POCUS) techniques. POCUS is increasingly used to assist with diuretic decision‐making for patients with suspected volume overload. While developing evidence suggests that POCUS allows for rapid and safe evaluation of volume status, limited data exist regarding which POCUS assessments correlate best to filling pressure measurements obtained from rightheart catheterization (RHC). Methods: A single‐center observational exploratory study conducted at Oregon Health & Science University investigated POCUS volume assessment in adult patients scheduled to undergo RHC. Multiple POCUS measurements were performed directly prior to RHC in 28 patients to investigate correlations between POCUS and RHC measurements, specifically mean right atrial pressure (mRAP) and pulmonary capillary wedge pressure (PCWP). Results: POCUS measurements that correlated (either positively or negatively) with mRAP as measured by RHC included qualitative RV function assessment and tricuspid annular plane of systolic excursion (TAPSE) (r S = −0.421, p = 0.032, effect size = −0.699–0.047). Left atrial diameter measurement (r P = 0.651, p = S = 0.394, p = 0.050, effect size = 0.053–0.711), E/A ratio (r S = 0.446, p = 0.025, effect size = 0.048–0.708), total B‐line score (r S = 0.407, p = 0.031, effect size = −0.159–0.615), combined LA diameter and mitral valve inflow velocity (r P = 0.383, p = 0.044, effect size = 0.011–0.661), and combined E/e′ and E/A ratio (r P = 0.418, p = 0.027, effect size = 0.053–0.684) all correlated with PCWP. Discussion: Some correlation exists between POCUS measurements and RHC assessment of PCWP and mRAP. Larger prospective studies are needed to fully understand this correlation, particularly in the context of pre/post intervention and specific disease processes.


  • Open Access

    Considerations for Pre-deployment Planning in Point-of-Care Ultrasound Program Implementation: A HIMSS-SIIM Enterprise Imaging Community Whitepaper in Collaboration with AIUM

    by Allan Bottemiller, Robinson M. Ferre, Les R. Folio, Michael Toland, Jeremy S. Boyd, Kevin Piro, Adam Kielski, Teashia French, Alyssa Abo, Stephanie Bazinet, et al.

    Point-of-care ultrasound (POCUS) provides real-time diagnostic capabilities at the bedside. Implementing a POCUS program in an institution is a highly complex process. Coordinating the imaging workflow of numerous clinical specialties requires meticulous planning and appropriate oversight. This white paper describes the best practices for the critical pre-deployment phase of program implementation, after having established POCUS program governance. Important considerations during the pre-deployment phase include goal setting, scaling POCUS workflow across clinical, educational, and technological domains, and addressing budgetary concerns and complexity of deployment strategies. This paper also discusses the role of the POCUS workflow manager software in encounter-based imaging workflow and the role of a system-wide clinical ultrasound director. Furthermore, it outlines the necessary approvals needed to ensure compliance and program success, including securing approvals from key departments such as imaging informatics, information technology, cybersecurity, supply chain operations, clinical engineering, infection prevention, legal, and billing departments. Finally, it presents a sample comprehensive project charter to guide this complex integration process from business case development, to clinical go-live, emphasizing best practices for sustained adoption.

  • Point‐of‐Care Ultrasound in Hospital Medicine

    by John Kim, David Lee, Michael Schwartz, Tanping Wong, Kevin Piro, James C. Hudspeth, Lao‐Tzu Allan‐Blitz

    Point‐of‐care ultrasound (POCUS) is increasingly used in hospital medicine to support bedside diagnosis, management, and procedural safety. This narrative review aims to synthesize current evidence on POCUS applications in pneumonia, heart failure, deep vein thrombosis, and bedside procedures. While POCUS may be clinically useful for such use cases, its broader adoption is limited by training gaps, infrastructure constraints, and credentialing challenges. Standardizing curricula and institutional support are critical next steps to optimize POCUS adoption and impact. Broader implementation of POCUS may enhance diagnostic accuracy and care efficiency in inpatient settings.


  • Open Access

    Governance Considerations for Point-of-Care Ultrasound: a HIMSS-SIIM Enterprise Imaging Community Whitepaper in Collaboration with AIUM

    by Irene W. Y. Ma, Michael L. Francavilla, Jason T. Nomura, Adam Kielski, Francisco Fernandez, Kevin Piro, Rachel Liu, Josephine Valenzuela, Michael Toland, Jessica Koehler, et al.

    Point-of-care ultrasound (POCUS) has emerged as a standard of care across a variety of healthcare settings due to its ability to provide critical clinical information and as well as procedural guidance to clinicians directly at the bedside. Implementation of enterprise imaging (EI) strategies is needed such that POCUS images can be appropriately captured, indexed, managed, stored, distributed, viewed, and analyzed. Because of its unique workflow and educational requirements, reliance on traditional order-based workflow solutions may be insufficient. To improve patient care outcomes and operational efficiency, a robust governance committee for POCUS within healthcare systems that addresses pertinent institutional policies to ensure effective and sustainable implementation of enterprise imaging, appropriate to the specific clinical encounter-based workflow needs of POCUS, is critical. This white paper explores several key governance considerations in the formulation and structure of a POCUS enterprise imaging strategy, focusing on program governance, clinical governance, technology governance, information governance, and financial governance.


  • Open Access

    Just In Time! Assessment of Internal Medicine Resident Point of Care Ultrasound (POCUS) Attitudes and Behaviors After Spaced Intervention at Two Residency Programs

    by Kevin Piro, Patricia Carney, Christopher Smith

    Point of care ultrasound (POCUS) is a complex psychomotor skill that requires scaffolded support for skill acquisition. However, the effect of spaced curricular elements on learner POCUS behaviors are not clearly understood. Using a multi-site observational cross-sectional survey study, we measured resident baseline POCUS use, behaviors, and attitudes and then implemented POCUS workflow and just-in-time POCUS curricula during internal medicine resident ward rotations and assessed changes. Self-reported personal and team POCUS use and documentation habits all improved between baseline and the just-in-time teaching. Personal POCUS use correlated with team POCUS use (ρ=0.431; p<0.001) and co-resident POCUS use (ρ=0.242; p=0.035). Attending POCUS use correlated with team POCUS use (ρ=0.523; p< 0.001), but not personal use. Overall, we found moderate, but statistically significant, improvements in reported resident and team performance of POCUS and documentation habits, suggesting that just-in-time interventions may promote POCUS use. Co-learning also appears to be a key influencer for POCUS use.


  • Intestinal Ultrasound in Common Gastrointestinal Disorders

    by Kevin Piro, Irene W.Y. Ma, Hamid Shokoohi, Kerri Novak


  • Ultrasound of the Urinary System

    by Renee K. Dversdal, Kevin M. Piro, Robert W. Rope

  • Anuria Evaluation

    by Kevin M. Piro, Renee K. Dversdal