Aditya Pandya
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Aditya Pandya has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
Alexandre Douplik
Department of Physics, Ryerson University, Toronto, ON, M5B 2K3, Canada
5 shared publicationsCsilla Gergely
Montpellier Univ. (France)
2 shared publicationsHarshad Karia
Ryerson Univ. (Canada)
2 shared publicationsIrina Schelkanova
Department of Physics, Ryerson University, Toronto, ON, M5B 2K3, Canada
2 shared publicationsSlim Tajouri
Ryerson Univ. (Canada)
2 shared publicationsXiao Zheng
Ryerson Univ. (Canada)
2 shared publications
Latest Publications
- 14 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-4
Variable Exposure Portable Perfusion Monitor Using Commercial Vision Processing System-on-Modules (SOMs)
Laser speckle imaging (LSI) has been widely used to image blood flow in biomedical/clinical research. Commercially available perfusion monitoring systems are bulky, expensive, and lack portability. Portable devices that perform LSI using custom digital signal processors (DSPs) and smartphones have been proposed to perform single-exposure LSI to monitor blood flow. While these can perform LSI, it is difficult to estimate flow rates using single exposure LSI. In this study, we use NVIDIA’s Xavier NX embedded vision processing platform to perform variable exposure LSI to evaluate flow rates in a 3-D printed flow phantom. A low-cost Raspberry Pi HQ camera was used to acquire LSI images and the increased sensitivity of the camera allowed images to be captured with exposure times 12 mm/s) flow rates were distinguished. Such a platform can extend the use of portable LSI devices in peri-operative, postoperative, and other point-of-care applications as this platform can be commercialized into a tablet-like form factor for convenient portable operation.
- 14 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-4
Variable Exposure Portable Perfusion Monitor Using Commercial Vision Processing System-on-Modules (SOMs)
Laser speckle imaging (LSI) has been widely used to image blood flow in biomedical/clinical research. Commercially available perfusion monitoring systems are bulky, expensive, and lack portability. Portable devices that perform LSI using custom digital signal processors (DSPs) and smartphones have been proposed to perform single-exposure LSI to monitor blood flow. While these can perform LSI, it is difficult to estimate flow rates using single exposure LSI. In this study, we use NVIDIA’s Xavier NX embedded vision processing platform to perform variable exposure LSI to evaluate flow rates in a 3-D printed flow phantom. A low-cost Raspberry Pi HQ camera was used to acquire LSI images and the increased sensitivity of the camera allowed images to be captured with exposure times 12 mm/s) flow rates were distinguished. Such a platform can extend the use of portable LSI devices in peri-operative, postoperative, and other point-of-care applications as this platform can be commercialized into a tablet-like form factor for convenient portable operation.
- 20 August 2019
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 10 (9) , 4656-4663
Spatio-angular filter (SAF) imaging device for deep interrogation of scattering media
Optical microscopy is limited to shallow interrogation depths as high-resolution imaging in scattering media is challenging. Current methods require complex and expensive experimental setup or suffer from low resolution. Through gating of photons exiting the scattering media using a restricted numerical aperture (NA) fiber optic plate (FOP), we establish a novel spatio-angular filter imaging device that allows deeper imaging in scattering media. Using dilutions of Intralipid (1-4 v/v%) and a USAF resolution target, it is shown that by reducing the NA of the FOP from 0.55 to 0.17, the interrogation depth improves ~2 times using trans-illumination.
- 20 August 2019
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 10 (9) , 4656-4663
Spatio-angular filter (SAF) imaging device for deep interrogation of scattering media
Optical microscopy is limited to shallow interrogation depths as high-resolution imaging in scattering media is challenging. Current methods require complex and expensive experimental setup or suffer from low resolution. Through gating of photons exiting the scattering media using a restricted numerical aperture (NA) fiber optic plate (FOP), we establish a novel spatio-angular filter imaging device that allows deeper imaging in scattering media. Using dilutions of Intralipid (1-4 v/v%) and a USAF resolution target, it is shown that by reducing the NA of the FOP from 0.55 to 0.17, the interrogation depth improves ~2 times using trans-illumination.
- 1 February 2018
- Published by Elsevier in Respiratory Physiology & Neurobiology
- Vol. 249, 62-68
The effect of continuous positive airway pressure on spectral encephalogram characteristics in stroke patients with obstructive sleep apnea
- 1 February 2018
- Published by Elsevier in Respiratory Physiology & Neurobiology
- Vol. 249, 62-68
The effect of continuous positive airway pressure on spectral encephalogram characteristics in stroke patients with obstructive sleep apnea
- 18 January 2018
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10612
Holographic interferometry imaging monitoring of photodynamic (PDT) reactions in gelatin biophantom
Heat and photochemical reactions with human hemoglobin and photosensitizer were monitored by holography interference method in gelatin phantom. The method has successfully facilitated monitoring the reactions as a highresolution refraction index mapping in real time video regime. Methylene Blue was exploited as a photosensitizer.
- 18 January 2018
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10612
Holographic interferometry imaging monitoring of photodynamic (PDT) reactions in gelatin biophantom
Heat and photochemical reactions with human hemoglobin and photosensitizer were monitored by holography interference method in gelatin phantom. The method has successfully facilitated monitoring the reactions as a highresolution refraction index mapping in real time video regime. Methylene Blue was exploited as a photosensitizer.
- 1 January 2018
- Published by Optica Publishing Group
- p. SeM2E.6
Raman spectroscopy and biochemical modeling of ex-vivo breast tissues and deparaffinized tissue samples
Raman spectroscopy (RS) can provide a molecular vibrational fingerprint of an analyte. In this study, RS was used to distinguish normal tissues from tumor tissues using ex-vivo and deparaffinized breast tissues.
- 1 January 2018
- Published by Optica Publishing Group
- p. SeM2E.6
Raman spectroscopy and biochemical modeling of ex-vivo breast tissues and deparaffinized tissue samples
Raman spectroscopy (RS) can provide a molecular vibrational fingerprint of an analyte. In this study, RS was used to distinguish normal tissues from tumor tissues using ex-vivo and deparaffinized breast tissues.
- 1 January 2018
- Published by Optica Publishing Group
- p. JTu2A.41
Tissue Phantoms with Patterned Oxygenation for Photoacoustic Applications
Aluminium sulphonated phthalocyanine (AlPs) photosensitiser mixed with Hemoglobin (Hb) was used to create patterned oxygenation states of Hb in tissue mimicking gelatin phantoms. Temporal study of Hb conversion and an oxygenation patterned phantom is presented.
- 1 January 2018
- Published by Optica Publishing Group
- p. JTu2A.41
Tissue Phantoms with Patterned Oxygenation for Photoacoustic Applications
Aluminium sulphonated phthalocyanine (AlPs) photosensitiser mixed with Hemoglobin (Hb) was used to create patterned oxygenation states of Hb in tissue mimicking gelatin phantoms. Temporal study of Hb conversion and an oxygenation patterned phantom is presented.
- 1 January 2018
- Published by Optica Publishing Group
- p. JTu2A.107
Lens-less Micro-endoscopy through highly scattering media
We demonstrate a setup based on lensless, minimally invasive micro-endoscope to image biological samples through scattering medium. We present in-vitro results of Polydimethylsiloxane micro-channels filled with Hemoglobin covered by intralipid mimicking epidermis of human skin.
- 1 January 2018
- Published by Optica Publishing Group
- p. JTu2A.107
Lens-less Micro-endoscopy through highly scattering media
We demonstrate a setup based on lensless, minimally invasive micro-endoscope to image biological samples through scattering medium. We present in-vitro results of Polydimethylsiloxane micro-channels filled with Hemoglobin covered by intralipid mimicking epidermis of human skin.
- 1 January 2013
- Published by Springer Nature
- p. 1109-1112
Ultrasound-mediated study of the electrokinetic effects in gelatin phantoms
- 1 January 2013
- Published by Springer Nature
- p. 1109-1112
Ultrasound-mediated study of the electrokinetic effects in gelatin phantoms