EFEdward Florez

Edward Florez

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Edward Florez has a total of 39 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Optimizing MRI sequences and images for MRI-based stereotactic radiosurgery treatment planning

    by Somayeh Taghizadeh, Cecille Labuda, Claus Chunli Yang, Bart Morris, Madhava R. Kanakamedala, Srinivasan Vijayakumar, Roberto Rey-Dios, William N. Duggar, Edward Florez, Ali Fatemi

    Development of MRI sequences and processing methods for the production of images appropriate for direct use in stereotactic radiosurgery (SRS) treatment planning. MRI is useful in SRS treatment planning, especially for patients with brain lesions or anatomical targets that are poorly distinguished by CT, but its use requires further refinement. This methodology seeks to optimize MRI sequences to generate distortion-free and clinically relevant MR images for MRI-only SRS treatment planning. We used commercially available SRS MRI-guided radiotherapy phantoms and eight patients to optimize sequences for patient imaging. Workflow involved the choice of correct MRI sequence(s), optimization of the sequence parameters, evaluation of image quality (artifact free and clinically relevant), measurement of geometrical distortion, and evaluation of the accuracy of our offline correction algorithm. CT images showed a maximum deviation of 1.3 mm and minimum deviation of 0.4 mm from true fiducial position for SRS coordinate definition. Interestingly, uncorrected MR images showed maximum deviation of 1.2 mm and minimum of 0.4 mm, comparable to CT images used for SRS coordinate definition. After geometrical correction, we observed a maximum deviation of 1.1 mm and minimum deviation of only 0.3 mm. Our optimized MRI pulse sequences and image correction technique show promising results; MR images produced under these conditions are appropriate for direct use in SRS treatment planning.


  • Open Access

    Multiparametric Magnetic Resonance Imaging in the Assessment of Primary Brain Tumors Through Radiomic Features: A Metric for Guided Radiation Treatment Planning

    by Edward Florez, Todd Nichols, Ellen E Parker, Seth T. Lirette, Candace M. Howard, Ali Fatemi

    The definition of radiotherapy target volume is a critical step in treatment planning for all tumor sites. Conventional magnetic resonance imaging (MRI) pulse sequences are used for the definition of the gross target volume (GTV) and the contouring of glioblastoma multiforme (GBM) and meningioma. We propose the use of multiparametric MRI combined with radiomic features to improve the texture-based differentiation of tumor from edema for GTV definition and to differentiate vasogenic from tumor cell infiltration edema. Twenty-five patients with brain tumor and peritumoral edema (PTE) were assessed. Of the enrolled patients, 17 (63 ± 10 years old, six female and 11 male patients) were diagnosed with GBM and eight (64 ± 14 years old, five female and three male patients) with meningioma. A 3 Tesla (3T) MRI scanner was used to scan patients using a 3D multi-echo Gradient Echo (GRE) sequence. After the acquisition process, two experienced neuroradiologists independently used an in-house semiautomatic algorithm to conduct a segmentation of two regions of interest (ROI; edema and tumor) in all patients using functional MRI sequences, apparent diffusion coefficient (ADC), and dynamic contrast-enhanced MRI (DCE-MRI), as well as anatomical MRI sequences—T1-weighted, T2-weighted and fluid-attenuated inversion recovery (FLAIR). Radiomic (computer-extracted texture) features were extracted from all ROIs through different approaches, including first-, second-, and higher-order statistics, both with and without normalization, leading to the calculation of around 300 different texture parameters for each ROI. Based on the extracted parameters, a least absolute shrinkage and selection operator (LASSO) analysis was used to isolate the parameters that best differentiated edema from tumors while irrelevant parameters were discarded. The parameters chosen by LASSO were used to perform statistical analyses which allowed identification of the variables with the best discriminant ability in all scenarios. Receiver operating characteristic results showcase both the best single discriminator and the discriminant capacity of the model using all variables selected by LASSO. Excellent results were obtained for patients with GBM with all MRI sequences, with and without normalization; a T1-weighted sequence postcontrast (T1W+C) with normalization offered the best tumor classification (area under the curve, AUC > 0.97). For patients with meningioma, a good model of tumor classification was obtained through the T1-weighted sequence (T1W) without normalization (AUC > 0.71). However, there was no agreement between the results of both radiologists for some MRI sequences analyzed for patients with GBM and meningioma. In conclusion, a small subset of radiomic features showed an excellent ability to distinguish edema from tumor tissue through its most discriminating features.


  • Open Access

    Assessment of Treatment Response Following Yttrium-90 Transarterial Radioembolization of Liver Malignancies

    by Charles S. Adcock, Edward Florez, Kevin A Zand, Akash Patel, Candace M. Howard, Ali Fatemi

    Transarterial radioembolization using yttrium-90 microspheres is an established and effective treatment for liver malignancies. Determining response to this treatment is difficult due to the radical changes that occur in tissue as a response to radiation. Though accurate assessment of treatment response is paramount for proper patient disposition, there is currently no standardized assessment protocol. Current methods of assessment often consider changes in size, necrosis, vascularity, fluorodeoxyglucose-positron emission tomography FDG-PET metabolic activity, and diffusion using diffusion-weighted magnetic resonance imaging (DWI). Current methods of assessment require a lag time of one to two months post-treatment to determine treatment effectiveness. This delay is a hindrance to obtaining better patient outcomes, giving rise to a need to identify markers for faster determination of treatment efficacy.


  • Comparative Effectiveness of Tumor Response Assessment Methods: Standard of Care Versus Computer-Assisted Response Evaluation

    by Brian C. Allen, Edward Florez, Reza Sirous, Seth T. Lirette, Michael Griswold, Erick M. Remer, Zhen J. Wang, Jacob E. Bieszczad, Kelly L. Cox, Ajit H. Goenka, et al.

    Purpose To compare the effectiveness of metastatic tumor response evaluation with computed tomography using computer-assisted versus manual methods. Materials and Methods In this institutional review board–approved, Health Insurance Portability and Accountability Act–compliant retrospective study, 11 readers from 10 different institutions independently categorized tumor response according to three different therapeutic response criteria by using paired baseline and initial post-therapy computed tomography studies from 20 randomly selected patients with metastatic renal cell carcinoma who were treated with sunitinib as part of a completed phase III multi-institutional study. Images were evaluated with a manual tumor response evaluation method (standard of care) and with computer-assisted response evaluation (CARE) that included stepwise guidance, interactive error identification and correction methods, automated tumor metric extraction, calculations, response categorization, and data and image archiving. A crossover design, patient randomization, and 2-week washout period were used to reduce recall bias. Comparative effectiveness metrics included error rate and mean patient evaluation time. Results The standard-of-care method, on average, was associated with one or more errors in 30.5% (6.1 of 20) of patients, whereas CARE had a 0.0% (0.0 of 20) error rate ( P < .001). The most common errors were related to data transfer and arithmetic calculation. In patients with errors, the median number of error types was 1 (range, 1 to 3). Mean patient evaluation time with CARE was twice as fast as the standard-of-care method (6.4 minutes v 13.1 minutes; P < .001). Conclusion CARE reduced errors and time of evaluation, which indicated better overall effectiveness than manual tumor response evaluation methods that are the current standard of care.