RMRobert T. Marcotte

Robert T. Marcotte

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Robert T. Marcotte has a total of 22 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Independent Validation of Sedentary Time and Physical Activity Intensity Accelerometer Algorithms in Adolescents

    by John R. Sirard, Tanusree Kumar, Robert T. Marcotte, John Chase, Melanna F. Cox, Marcos Amalbert-Birriel, John W. Staudenmayer

    Few accelerometer data processing methods target adolescents, and the appropriateness of child or adult methods in adolescent samples is not clear. Purpose : The purpose of this study was to validate commonly used youth and adult methods for processing accelerometer data into intensity categories in a sample of 13- to 17-year-old adolescents, using free-living direct observation as the criterion measure. Methods : N = 42 (mean ± SD ; age = 15.2 ± 1.5 years, 50% male) engaged in their usual behaviors during four 1-hr video-recorded free-living sessions. Participants simultaneously wore right hip and nondominant wrist accelerometers, both sampling at 80 Hz. Videos were annotated for all changes in behaviors lasting ≥1 s, and age-adjusted metabolic equivalent values categorized sedentary behavior, light, moderate, vigorous, as well as moderate and vigorous physical activity. Accelerometer data were processed using 12 youth and nine adult methods, then synchronized with the video annotations. Agreement statistics, bias with 95% confidence interval, and mean absolute percent error were calculated for minutes spent in each intensity category. Results : No method was unbiased for all intensity categories. The Crouter 2015 youth wrist (vertical axis and vector magnitude) methods and the Hildebrand 2014 adult hip method were not biased for moderate physical activity, vigorous physical activity, or moderate and vigorous physical activity. Several other youth and adult methods were unbiased for sedentary behavior, including those using the 100 counts/min hip cut point. Conclusion : No youth or adult method accurately classified all intensity categories in this sample of adolescents. Additional methods need to be independently validated or developed to provide a method or a set of compatible methods that can work across life stage transitions.

  • Open Access

    Update and Novel Validation of a Pregnancy Physical Activity Questionnaire

    by Lisa Chasan-Taber, Susan Park, Robert T Marcotte, John Staudenmayer, Scott Strath, Patty Freedson

    The aim of this study was to update and validate the Pregnancy Physical Activity Questionnaire (PPAQ), using novel and innovative accelerometer and wearable camera measures in a free-living setting, to improve the measurement performance of this method for self-reporting physical activity. A prospective cohort of 50 eligible pregnant women were enrolled in early pregnancy (mean = 14.9 weeks’ gestation). In early, middle, and late pregnancy, participants completed the updated PPAQ and, for 7 days, wore an accelerometer (GT3X-BT; ActiGraph, Pensacola, Florida) on the nondominant wrist and a wearable camera (Autographer; OMG Life (defunct)). At the end of the 7-day period, participants repeated the PPAQ. Spearman correlations between the PPAQ and accelerometer data ranged from 0.37 to 0.44 for total activity, 0.17 to 0.53 for moderate- to vigorous-intensity activity, 0.19 to 0.42 for light-intensity activity, and 0.23 to 0.45 for sedentary behavior. Spearman correlations between the PPAQ and wearable camera data ranged from 0.52 to 0.70 for sports/exercise and from 0.26 to 0.30 for transportation activity. Reproducibility scores ranged from 0.70 to 0.92 for moderate- to vigorous-intensity activity and from 0.79 to 0.91 for sports/exercise, and were comparable across other domains of physical activity. The PPAQ is a reliable instrument and a valid measure of a broad range of physical activities during pregnancy.


  • Open Access

    Cross-Sectional Associations of 24-Hour Sedentary Time, Physical Activity, and Sleep Duration Compositions with Sleep Quality and Habits in Preschoolers

    by Christine W. St. Laurent, Sarah Burkart, Katrina Rodheim, Robert Marcotte, Rebecca M. C. Spencer

    Although some studies indicate physical activity and sleep quality are positively associated in children, most reports examined physical activity independent of other 24-h behaviors and focused on older children. The aim of this cross-sectional study was to examine the predicted changes in sleep efficiency and habits when reallocating time between movement behaviors using compositional isotemporal substitution in preschool-aged children. Accelerometers were worn by 288 participants (51.6 ± 9.5 months) for up to 16 days. Sleep outcomes included sleep efficiency, nap frequency, sleep disturbances, and bedtime resistance. Compositional isotemporal substitution analyses demonstrated that the combined effect of 24-h movement behaviors was associated with sleep efficiency (p < 0.001) and nap frequency (p < 0.003). When sleep increased by 30 min at the expense of stationary time or light physical activity, estimates of sleep efficiency and bedtime resistance decreased while nap frequency increased. When stationary time increased by 30 min from moderate to vigorous physical activity, estimated sleep efficiency increased and sleep disturbances decreased. Although this study presents preliminary evidence that 24-h movement behavior compositions in early childhood are associated with sleep quality and nap frequency, estimated effects from theoretical time reallocations across sleep outcomes were mixed.


  • A Method To Estimate Free-living Behaviors Using High-frequency Wrist Accelerometer Data

    by Robert T. Marcotte, Greg J. Petrucci, Melanna F. Cox, Patty S. Freedson, John W. Staudenmayer, John R. Sirard

  • Estimating Sedentary Time from a Hip- and Wrist-Worn Accelerometer

    by Robert T. Marcotte, Greg J. Petrucci, Melanna F. Cox, Patty S. Freedson, John W. Staudenmayer, John R. Sirard

    Purpose: This study aimed to determine the validity of existing methods to estimate sedentary behavior (SB) under free-living conditions using ActiGraph GT3X+ accelerometers (AG). Methods: Forty-eight young (18–25 yr) adults wore an AG on the right hip and nondominant wrist and were video recorded during four 1-h sessions in free-living settings (home, community, school, and exercise). Direct observation videos were coded for postural orientation, activity type (e.g., walking), and METs derived from the Compendium of Physical Activities, which served as the criterion measure of SB (sitting or lying posture, VM), raw acceleration and arm angle (sedentary sphere), Euclidean norm minus one (ENMO) corrected for gravity (mg) thresholds, uni- or triaxial sojourn hybrid machine learning models (Soj1x and Soj3x), random forest (RF), and decision tree (TR) models were used to estimate SB minutes from AG data. Method bias, mean absolute percent error, and their 95% confidence intervals were estimated using repeated-measures linear mixed models. Results: On average, participants spent 34.1 min per session in SB. CPM100, CPM150, Soj1x, and Soj3x were the only methods to accurately estimate SB from the hip. Sedentary sphere and ENMO44.8 overestimated SB by 3.9 and 6.1 min, respectively, whereas the remaining wrist methods underestimated SB (range, 9.5–2.5 min). In general, mean absolute percent error was lower using hip methods compared with wrist methods. Conclusion: Accurate group-level estimates of SB from a hip-worn AG can be achieved using either simpler count-based approaches (CPM100 and CPM150) or machine learning models (Soj1x and Soj3x). Wrist methods did not provide accurate or precise estimates of SB. The development of large open-source free-living calibration data sets may lead to improvements in SB estimates.


  • Application of the ActiGraph GT9X IMU for the assessment of turning during walking and running

    by Robert T Marcotte, David R Bassett, Joshua T Weinhandl, Scott E Crouter

    Objective . The primary purpose of this study was to examine the use of the ActiGraph GT9X gyroscope and magnetometer for turn detection and quantifying turn degree during walking and running. The secondary purpose was to examine the effect of varying turn degrees during walking and running on oxygen consumption. Approach . Participants (N = 17) completed pivot trials, straight-line treadmill walking and running (3–6 mph) and four turn conditions (45°, 90°, 135°, and 180°) during over-ground walking and running. Pivot trials were completed for 1 min and walking/running trials were completed for 6 min, both with a turn frequency of 10 turns/min. Data were collected using a GT9X device (right hip) and a Cosmed K4b 2 (measured oxygen consumption). Raw GT9X gyroscope and magnetometer data were processed through various low-pass filter frequencies (0.25–2.0 Hz). Treadmill and pivot trials were used to develop thresholds for turn detection using gyroscope and magnetometer data and cross-validated using the over-ground trials. Linear mixed models were used to compare actual and estimated number of turns, measured and estimated turn degree, and differences in VO 2 across walking and running speed and turn degree. Main results . Greater than 98% of turns were detected when using gyroscope data filtered at 0.25 Hz and turn degree was estimated within 2.2° of measured turn degree across all speeds. In general, the VO 2 of walking and running increased as the turn degree increased beyond 135°. Significance . The GT9X gyroscope, when filtered at 0.25 Hz can be used to detect the number of turns and estimate turn degree. The magnetometer, when filtered at 0.75 Hz, was useful for detecting the number of turns, however turn detection was more accurate using the gyroscope.