S. Sudha
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
S. Sudha has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Arun Seeralan
School of Engineering, Asia Pacific University of Technology and Innovation, Jalan Teknologi 5, Taman Teknologi Malaysia, 57000, Wilayah Persekutuan Kuala Lumpur, Malaysia
1 shared publication G. Chandrasekaran
Department of EEE, Velalar College of Engineering and Technology, Erode, India
1 shared publicationJayanthi K. B.
Department of Electronics and Communication Engineering, K.S.Rangasamy College of Technology, Tamil Nadu, India
1 shared publication- K. T. Kalaiselvi
Department of Management Studies, Velalar College of Engineering and Technology, Erode, India
1 shared publication N. S. Kumar
Department of Computer Science and Engineering, SRM Institute of Science and Technology, Chennai, India
1 shared publicationNirmala Madian
Department of Electronics and Communication Engineering, Sri Shakthi Institute of Engineering and Technology, Coimbatore, 641 062, India
1 shared publication
Latest Publications
- 1 January 2024
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 3161 (1) , 020027
Design and development of auto oxygen concentrator with SOS alert for hiking people
Trekking is a popular recreational activity. Hiking is popular among many people. Out-and-back, destination, and loop walks are the most prevalent types of walk Trekking is a popular recreational activity. Hiking is popular among many people. Out-and-back, destination, and loop walks are the most prevalent types of walk
- 1 January 2024
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 3161 (1) , 020027
Design and development of auto oxygen concentrator with SOS alert for hiking people
Trekking is a popular recreational activity. Hiking is popular among many people. Out-and-back, destination, and loop walks are the most prevalent types of walk Trekking is a popular recreational activity. Hiking is popular among many people. Out-and-back, destination, and loop walks are the most prevalent types of walk
- 9 July 2018
- Published by Springer Nature in Journal of Medical Systems
- Vol. 42 (8) , 154-154:8
Convolutional Neural Network for Segmentation and Measurement of Intima Media Thickness
The measurement of Carotid Intima Media Thickness (IMT) on Common Carotid Artery (CCA) is a principle marker of risk of cardiovascular disease. This paper presents a novel method of using deep Convolutional Neural Network (CNN) for identification and measurement of IMT on the far wall of the artery. The Region of Interest (ROI) is extracted using CNN architecture with 8 layers. 110 subjects are taken for the study. Each subject is recorded with one Right Common Carotid Artery (RCCA) and Left Common Carotid Artery (LCCA) frame resulting in 220 recordings. Patch based segmentation with 2640 patches are given to the training network for ROI localization. Intima Media Complex (IMC) is the area where IMT is measured. This region is extracted after defining the ROI. Keeping in mind the end objective of measurement of IMT values binary threshold with snake algorithm is applied to extract the lumen-intima and media-adventitia boundary. IMT values are measured for 20 cases and mean difference is found to be 0.08 mm.
- 9 July 2018
- Published by Springer Nature in Journal of Medical Systems
- Vol. 42 (8) , 154-154:8
Convolutional Neural Network for Segmentation and Measurement of Intima Media Thickness
The measurement of Carotid Intima Media Thickness (IMT) on Common Carotid Artery (CCA) is a principle marker of risk of cardiovascular disease. This paper presents a novel method of using deep Convolutional Neural Network (CNN) for identification and measurement of IMT on the far wall of the artery. The Region of Interest (ROI) is extracted using CNN architecture with 8 layers. 110 subjects are taken for the study. Each subject is recorded with one Right Common Carotid Artery (RCCA) and Left Common Carotid Artery (LCCA) frame resulting in 220 recordings. Patch based segmentation with 2640 patches are given to the training network for ROI localization. Intima Media Complex (IMC) is the area where IMT is measured. This region is extracted after defining the ROI. Keeping in mind the end objective of measurement of IMT values binary threshold with snake algorithm is applied to extract the lumen-intima and media-adventitia boundary. IMT values are measured for 20 cases and mean difference is found to be 0.08 mm.