Atsushi Hosoi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Atsushi Hosoi has a total of 65 co-authors. Here are the top co-authors by number of shared publications:
Hiroyuki Kawada
Waseda University
17 shared publicationsKeita Wada
Department of Applied Mechanics and Aerospace Engineering, Waseda University, Japan
3 shared publications- Kristine Munk Jespersen
Department of Wind and Energy Systems, Technical University of Denmark, Frederiksborgvej 399, 4000 Roskilde, Denmark
3 shared publications Dai Tsunoda
Mobility Business Headquarters Mobility R&D Center, Resonac Corporation, Tokyo, Japan
2 shared publicationsH Kawada
Department of Applied Mechanics and Aerospace Engineering, Waseda University, 3-4-1, Okubo, Shinjuku-ku, Tokyo 169-8555, Japan
2 shared publicationsHiroki Ota
Department of Materials Science, Waseda University, Japan
2 shared publications
Latest Publications
- Open Access
- 13 April 2026
- Published by Taylor & Francis in Advanced Composite Materials
- p. 1-15
Experimental evaluation of fatigue properties and failure mechanisms of thick carbon fiber-reinforced plastic laminates under three-point bending load
- 13 April 2026
- Published by Taylor & Francis in Advanced Composite Materials
- p. 1-15
Open AccessExperimental evaluation of fatigue properties and failure mechanisms of thick carbon fiber-reinforced plastic laminates under three-point bending load
- Open Access
- 23 March 2026
- Published by Taylor & Francis in Advanced Composite Materials
- Vol. 35 (6) , 961-988
Effects of self-heating on fatigue behavior of quasi-isotropic CFRP laminates under ultrasonic loading
1. Carbon fiber-reinforced plastics (CFRPs) are used in aircraft engine fan blades and wind turbine blades, and these components are subjected to fatigue loads on the order of 108–109 cycles [1,2]....
- 23 March 2026
- Published by Taylor & Francis in Advanced Composite Materials
- Vol. 35 (6) , 961-988
Open AccessEffects of self-heating on fatigue behavior of quasi-isotropic CFRP laminates under ultrasonic loading
1. Carbon fiber-reinforced plastics (CFRPs) are used in aircraft engine fan blades and wind turbine blades, and these components are subjected to fatigue loads on the order of 108–109 cycles [1,2]....
- Open Access
- 23 July 2025
- Published by Springer Nature in Surface Science and Technology
- Vol. 3 (1) , 1-3
Correction: Interfacial microstructure effects on the bonding strength and interlaminar fracture toughness of aluminum alloys thermally bonded to carbon fiber-reinforced polyetheretherketone
- 23 July 2025
- Published by Springer Nature in Surface Science and Technology
- Vol. 3 (1) , 1-3
Open AccessCorrection: Interfacial microstructure effects on the bonding strength and interlaminar fracture toughness of aluminum alloys thermally bonded to carbon fiber-reinforced polyetheretherketone
- Open Access
- 10 June 2025
- Published by Springer Nature in Surface Science and Technology
- Vol. 3 (1) , 1-12
Interfacial microstructure effects on the bonding strength and interlaminar fracture toughness of aluminum alloys thermally bonded to carbon fiber-reinforced polyetheretherketone
In this study, to improve the bonding strength and interlaminar fracture toughness of hot-pressed joints fabricated using aluminum alloys and carbon fiber-reinforced thermoplastic laminates (polyetheretherketone as the matrix), several pretreatment strategies were implemented to modify the aluminum surface. Specifically, we evaluated the optimal conditions for silane coupling treatment and determined the effects of surface microstructuring on the bonding strength and interlaminar fracture toughness. The experimental results suggested that reducing the hydrolysis time of the amino-silane coupling agent reduces the reaction between silanols and improves the bonding strength. In addition, the bonding strength of specimens pretreated using a pulse wave laser to make grooved structures on the aluminum alloy surface was up to 1.97 times higher than specimens without grooved structures. The interlaminar fracture toughness of the specimen with a grooved structure on the surface of the aluminium alloy was approximately 2.8 times that of the specimen without a structure, and for the bonded specimen with a nano-structure introduced by anodisation and etching, it was approximately 2.0 times. Our findings also help clarify the mechanisms behind these improvements. By refining the hydrolysis conditions of the silane coupling agent, we strengthened the chemical bonding at the interface. Furthermore, the additional micro and nanoscale structures enhanced mechanical interlocking and promoted plastic deformation during crack propagation. Ultimately, these effects partially overcome the inherent trade-off between strength and toughness, supporting the development of advanced applications.
- 10 June 2025
- Published by Springer Nature in Surface Science and Technology
- Vol. 3 (1) , 1-12
Open AccessInterfacial microstructure effects on the bonding strength and interlaminar fracture toughness of aluminum alloys thermally bonded to carbon fiber-reinforced polyetheretherketone
In this study, to improve the bonding strength and interlaminar fracture toughness of hot-pressed joints fabricated using aluminum alloys and carbon fiber-reinforced thermoplastic laminates (polyetheretherketone as the matrix), several pretreatment strategies were implemented to modify the aluminum surface. Specifically, we evaluated the optimal conditions for silane coupling treatment and determined the effects of surface microstructuring on the bonding strength and interlaminar fracture toughness. The experimental results suggested that reducing the hydrolysis time of the amino-silane coupling agent reduces the reaction between silanols and improves the bonding strength. In addition, the bonding strength of specimens pretreated using a pulse wave laser to make grooved structures on the aluminum alloy surface was up to 1.97 times higher than specimens without grooved structures. The interlaminar fracture toughness of the specimen with a grooved structure on the surface of the aluminium alloy was approximately 2.8 times that of the specimen without a structure, and for the bonded specimen with a nano-structure introduced by anodisation and etching, it was approximately 2.0 times. Our findings also help clarify the mechanisms behind these improvements. By refining the hydrolysis conditions of the silane coupling agent, we strengthened the chemical bonding at the interface. Furthermore, the additional micro and nanoscale structures enhanced mechanical interlocking and promoted plastic deformation during crack propagation. Ultimately, these effects partially overcome the inherent trade-off between strength and toughness, supporting the development of advanced applications.
- Open Access
- 3 February 2025
- Published by Wiley in Fatigue & Fracture of Engineering Materials & Structures
- Vol. 48 (4) , 1879-1892
Mechanism of Fatigue Crack Closure in Steel Under High‐Density Pulsed Current
This study is aimed at clarifying the mechanism of effectively healing fatigue cracks in steel; austenitic stainless steel, SUS304; and hot work tool steel, SKD61, using high‐density pulsed current. The results show that the current concentration occurred at the crack tip for SUS304, and crack closure was observed near the fatigue crack tip. On the other hand, crack closure was observed at the notch tip in SKD61. The fatigue crack closure phenomena were verified by finite element analysis, revealing that contact pressure was applied behind the crack tip owing to local bending deformation associated with residual stress near the crack tip. For effective crack healing, it is necessary to bond the interface leveraging compressive stress and Joule heat generated at the crack tip during current application.
- 3 February 2025
- Published by Wiley in Fatigue & Fracture of Engineering Materials & Structures
- Vol. 48 (4) , 1879-1892
Open AccessMechanism of Fatigue Crack Closure in Steel Under High‐Density Pulsed Current
This study is aimed at clarifying the mechanism of effectively healing fatigue cracks in steel; austenitic stainless steel, SUS304; and hot work tool steel, SKD61, using high‐density pulsed current. The results show that the current concentration occurred at the crack tip for SUS304, and crack closure was observed near the fatigue crack tip. On the other hand, crack closure was observed at the notch tip in SKD61. The fatigue crack closure phenomena were verified by finite element analysis, revealing that contact pressure was applied behind the crack tip owing to local bending deformation associated with residual stress near the crack tip. For effective crack healing, it is necessary to bond the interface leveraging compressive stress and Joule heat generated at the crack tip during current application.
- 20 November 2024
- Published by Wiley in Fatigue & Fracture of Engineering Materials & Structures
- Vol. 48 (2) , 967-975
Fatigue Properties of Carbon Fiber–Reinforced Foams and Experimental Observation of the Damage Growth Mechanism
Carbon fiber–reinforced foams (CFRFs) are expanded thermoplastic composite materials reinforced with three‐dimensional discontinuous carbon fibers. Herein, the effects of their unique internal structure on fatigue properties were investigated. Through tension‐tension fatigue tests and the digital image correlation (DIC) method, distinct stiffness reduction behavior was observed across the entire specimen and at the fracture points. The results suggest that local stiffness reduction behavior affects the fatigue properties. From the DIC method, damage was observed by scanning electron microscopy and the fiber tortuosity, and the void fraction were quantified using X‐ray computed tomography scans. In the case of three‐dimensional oriented fibers, stress was concentrated at fiber ends, fiber intersections, and bent fibers, resulting in fiber pull‐outs and matrix cracks. In the case of voids, the void size affected damage development, and the stress concentration around the voids caused fiber fracture and matrix cracks.
- 20 November 2024
- Published by Wiley in Fatigue & Fracture of Engineering Materials & Structures
- Vol. 48 (2) , 967-975
Fatigue Properties of Carbon Fiber–Reinforced Foams and Experimental Observation of the Damage Growth Mechanism
Carbon fiber–reinforced foams (CFRFs) are expanded thermoplastic composite materials reinforced with three‐dimensional discontinuous carbon fibers. Herein, the effects of their unique internal structure on fatigue properties were investigated. Through tension‐tension fatigue tests and the digital image correlation (DIC) method, distinct stiffness reduction behavior was observed across the entire specimen and at the fracture points. The results suggest that local stiffness reduction behavior affects the fatigue properties. From the DIC method, damage was observed by scanning electron microscopy and the fiber tortuosity, and the void fraction were quantified using X‐ray computed tomography scans. In the case of three‐dimensional oriented fibers, stress was concentrated at fiber ends, fiber intersections, and bent fibers, resulting in fiber pull‐outs and matrix cracks. In the case of voids, the void size affected damage development, and the stress concentration around the voids caused fiber fracture and matrix cracks.
- Open Access
- 25 October 2024
- Published by Springer Nature in Scientific Reports
- Vol. 14 (1) , 1-14
Fatigue life prediction of composite materials using strain distribution images and a deep convolution neural network
The damage process of composite materials, such as short fiber-reinforced plastics (SFRP), is complex. Therefore, it is necessary to accurately represent the damage process in fatigue life prediction. Herein, fatigue life prediction was conducted by combining the digital image correlation method, which is a non-destructive testing technique, with a convolutional neural network (CNN), using Xception as the network architecture. High prediction accuracy was obtained when training and testing were performed on the same SFRP specimens. In contrast, using different specimens for training and testing resulted in lower accuracy. This issue may be improved by increasing the number of specimens. The regions of interest in the model were visualized by Gradient-weighted Class Activation Mapping. Notably, the model indicated the breaking point as the region of interest from the early stages of the test. The breaking point was identified at an earlier stage by the CNN than by visual inspection, demonstrating the potential for a new method of damage observation.
- 25 October 2024
- Published by Springer Nature in Scientific Reports
- Vol. 14 (1) , 1-14
Open AccessFatigue life prediction of composite materials using strain distribution images and a deep convolution neural network
The damage process of composite materials, such as short fiber-reinforced plastics (SFRP), is complex. Therefore, it is necessary to accurately represent the damage process in fatigue life prediction. Herein, fatigue life prediction was conducted by combining the digital image correlation method, which is a non-destructive testing technique, with a convolutional neural network (CNN), using Xception as the network architecture. High prediction accuracy was obtained when training and testing were performed on the same SFRP specimens. In contrast, using different specimens for training and testing resulted in lower accuracy. This issue may be improved by increasing the number of specimens. The regions of interest in the model were visualized by Gradient-weighted Class Activation Mapping. Notably, the model indicated the breaking point as the region of interest from the early stages of the test. The breaking point was identified at an earlier stage by the CNN than by visual inspection, demonstrating the potential for a new method of damage observation.
- Open Access
- 1 November 2023
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 1293 (1) , 012019
Effect of span/thickness ratio on fatigue properties of thick quasi-isotropic CFRP laminates subjected to three-point bending loading
In this study, three-point bending fatigue tests were conducted to investigate damage growth behavior of thick quasi-isotropic carbon fiber reinforced plastic (CFRP) laminates. The span/thickness ratio L/h was varied for both static tests and fatigue tests to determine failure mechanisms. In the static tests, the failure mode changed from delamination to compressive buckling as span/thickness ratio increases. The apparent interlaminar shear strength was higher for the specimens with lower span/thickness ratios, and the shear failure was likely to be caused by oblique crack in 90° plies. In the fatigue tests, the specimens with span/thickness ratio L/h=7 caused delamination regardless of stress level. For the specimens with span/thickness ratio L/h =15, three types of failure modes were obtained depending on stress level; delamination near the neutral plane, buckling at compressive area and matrix crack at tensile area. During the fatigue tests, stiffness of specimens with different span/thickness ratios which fail in shear was compared using digital image correlation (DIC) method. The specimens with span/thickness ratio 4 suddenly decreased in stiffness without increasing normal strain over cycles. Both specimens with span/thickness ratio 4 and 11 finally failed by delamination but they showed different failure process in how normal or shear strain developed.
- 1 November 2023
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 1293 (1) , 012019
Open AccessEffect of span/thickness ratio on fatigue properties of thick quasi-isotropic CFRP laminates subjected to three-point bending loading
In this study, three-point bending fatigue tests were conducted to investigate damage growth behavior of thick quasi-isotropic carbon fiber reinforced plastic (CFRP) laminates. The span/thickness ratio L/h was varied for both static tests and fatigue tests to determine failure mechanisms. In the static tests, the failure mode changed from delamination to compressive buckling as span/thickness ratio increases. The apparent interlaminar shear strength was higher for the specimens with lower span/thickness ratios, and the shear failure was likely to be caused by oblique crack in 90° plies. In the fatigue tests, the specimens with span/thickness ratio L/h=7 caused delamination regardless of stress level. For the specimens with span/thickness ratio L/h =15, three types of failure modes were obtained depending on stress level; delamination near the neutral plane, buckling at compressive area and matrix crack at tensile area. During the fatigue tests, stiffness of specimens with different span/thickness ratios which fail in shear was compared using digital image correlation (DIC) method. The specimens with span/thickness ratio 4 suddenly decreased in stiffness without increasing normal strain over cycles. Both specimens with span/thickness ratio 4 and 11 finally failed by delamination but they showed different failure process in how normal or shear strain developed.
- Open Access
- 1 January 2023
- Published by Japan Society of Mechanical Engineers in Mechanical Engineering Journal
- Vol. 10 (4) , 23-00089
Very high-cycle fatigue properties of 90° unidirectional CFRP laminates and evaluation of fatigue limits by free volume measurement using positron microscopy
The objective of this study was to experimentally evaluate the fatigue limit of 90° unidirectional carbon fiber reinforced plastic (CFRP) laminates. The very high-cycle fatigue properties of the specimens were evaluated using ultrasonic and electromagnetic fatigue testing machines. Ultrasonic fatigue tests were conducted to obtain the fatigue properties under the giga-cycle regime. The specimen geometry was designed to resonate at 20 kHz, the specimen consisted of CFRP laminate and a metal tab to connect to the horn end of the testing machine. Additionally, the free volume of the matrix material, namely, epoxy resin, of the CFRP laminates was evaluated using the positron annihilation method. A slit was introduced in the specimen surface to identify the location of damage development, which facilitated the free volume measurement by positron microscopy. The obtained S-N curves reveal that failure did not occur at strain levels lower than εmax = 0.75% at the slit tip for all specimens up to N = 1.0 × 109 cycles. The free volume measurement for a specimen set above the threshold strain level revealed that the free volume increased in size and decreased in amount as the number of cycles increased. The test results revealed that the opposite trend existed below the threshold, which suggests that a fatigue limit may exist.
- 1 January 2023
- Published by Japan Society of Mechanical Engineers in Mechanical Engineering Journal
- Vol. 10 (4) , 23-00089
Open AccessVery high-cycle fatigue properties of 90° unidirectional CFRP laminates and evaluation of fatigue limits by free volume measurement using positron microscopy
The objective of this study was to experimentally evaluate the fatigue limit of 90° unidirectional carbon fiber reinforced plastic (CFRP) laminates. The very high-cycle fatigue properties of the specimens were evaluated using ultrasonic and electromagnetic fatigue testing machines. Ultrasonic fatigue tests were conducted to obtain the fatigue properties under the giga-cycle regime. The specimen geometry was designed to resonate at 20 kHz, the specimen consisted of CFRP laminate and a metal tab to connect to the horn end of the testing machine. Additionally, the free volume of the matrix material, namely, epoxy resin, of the CFRP laminates was evaluated using the positron annihilation method. A slit was introduced in the specimen surface to identify the location of damage development, which facilitated the free volume measurement by positron microscopy. The obtained S-N curves reveal that failure did not occur at strain levels lower than εmax = 0.75% at the slit tip for all specimens up to N = 1.0 × 109 cycles. The free volume measurement for a specimen set above the threshold strain level revealed that the free volume increased in size and decreased in amount as the number of cycles increased. The test results revealed that the opposite trend existed below the threshold, which suggests that a fatigue limit may exist.