TJTong Jiang

Tong Jiang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Tong Jiang has a total of 21 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Analogy Analysis of Height Exergy and Temperature Exergy in Energy Storage System

    by Yan Cui, Tong Jiang, Mulin Liu

    As a pivotal technology and infrastructure component for modern power systems, energy storage has experienced significant advancement in recent years. A fundamental prerequisite for designing future energy storage facilities lies in the systematic evaluation of energy conversion capabilities across diverse storage technologies. This study conducted a comparative analysis between pumped hydroelectric storage (PHS) and compressed air energy storage (CAES), defining the concepts of height exergy and temperature exergy. Height exergy is the maximum work capacity of a liquid due to height differences, while temperature exergy is the maximum work capacity of a gas due to temperature differences. The temperature exergy represents innovation in thermodynamic analysis; it is derived from internal exergy and proven through the Maxwell relation and the decoupling method of internal exergy, offering a more efficient method for calculating energy storage capacity in CAES systems. Mathematical models of height exergy and temperature exergy were established based on their respective forms. A unified calculation formula was derived, and their respective characteristics were analyzed. In order to show the meaning of temperature exergy more clearly and intuitively, a height exergy model of temperature exergy was established through analogy analysis, and it was concluded that the shape of the reservoir was a cone when comparing water volume to heat quantity, intuitively showing that the cold source had a higher energy storage density than the heat source. Finally, a typical hybrid PHS–CAES system was proposed, and a mathematical model was established and verified in specific cases based on height exergy and temperature exergy. It was demonstrated that when the polytropic exponent n = 1.2, the theoretical loss accounted for the largest proportion, which was 2.06%.

  • Open Access

    A Novel Isothermal Compressed Air Energy Storage System Based on Cooperative Operation of Two-Stage Liquid Piston Units

    by Yan Cui, Tong Jiang, Hongfei Hou

    The transition toward a renewable-based energy structure has significantly accelerated the advancement of energy storage technologies. Compressed air energy storage (CAES) is regarded as a highly promising long-duration energy storage solution due to the advantages of its large scale and long service life. However, the efficiency of conventional compressed air energy storage (CAES) systems remains limited due to the inadequate utilization of thermal energy. Isothermal compressed CAES (ICAES) technology, based on liquid pistons, can overcome the efficiency bottleneck by enabling temperature control during air compression. However, the operation of liquid pistons under high-pressure storage conditions remains a challenge because of the high compression ratio. To enhance the utilization rate of the two-stage liquid piston unit by using the synchronous operations of compression and discharge processes, this paper proposes a coordinated operation scheme. Then, a multi-stage ICAES system under constant-pressure air storage is proposed. Mathematical models and energy efficiency analysis methods of the multi-stage ICAES system are also established. Finally, the operational characteristics are analyzed in combination with the ICAES at 200 kWh. The results show that the proposed system can achieve an overall efficiency of 68.0%, under 85% and 90% efficiencies for low-pressure and linear equipment, respectively. The coordinated operation of the two-stage liquid piston unit can be further extended to multi-stage operations, demonstrating broad application prospects in ICAES systems.


  • Open Access

    A Constant-Pressure Air Storage Operation Strategy for an Isothermal Compressed Air Energy Storage System Based on a Linear-Drive Liquid Piston

    by Yan Cui, Tong Jiang, Zhengda Chen

    Compressed air energy storage (CAES) systems represent a critical technological solution for addressing power grid load fluctuations by generating electrical power during peak load periods and storing energy during low load periods. As a prominent branch of CAES, isothermal compressed air energy storage (ICAES) systems have attracted significant research attention due to their elimination of requirements for high-temperature storage chambers and high-temperature compressors. Implementing constant-pressure operation in air storage reservoirs not only enhances energy storage density but also improves system safety. However, existing constant-pressure air storage methodologies necessitate supplementary infrastructure, such as high-pressure water reservoirs or elevated hydraulic columns, thereby escalating capital expenditures. This study introduces a novel constant-pressure air storage strategy for ICAES systems utilizing a linear-driven liquid piston mechanism. The proposed approach achieves constant-pressure air storage through the dual-mode operation strategies of buffer tanks (CBA and CBP modes) and hydraulic cylinders (CPP and CPW modes), eliminating the requirement for an auxiliary high-pressure apparatus or extensive civil engineering modifications. A prototype two-stage constant-pressure ICAES architecture was proposed, integrating low-pressure equipment with liquid pistons and providing detailed operational processes for preconditioning, energy storage, and power generation. A comprehensive mathematical model of the system is developed and validated through process simulation and performance characterization of a 100 kWh capacity system. It demonstrates that under operational conditions of 1 MPa of low pressure and 5 MPa of storage pressure, the system achieves an efficiency of 74.0% when the low-pressure equipment and liquid piston exhibit efficiencies of 85% and 90%, respectively. Furthermore, parametric analysis reveals a negative correlation between system efficiency and low-pressure parameters.

  • Open Access

    Continuous Line Loss Calculation Method for Distribution Network Considering Collected Data of Different Densities

    by Yuying Li, Xiping Ma, Chen Liang, Yaxin Li, Zhou Cai, Tong Jiang

    In order to find the causes of statistical line loss abnormalities and propose better loss reduction strategies, it is necessary to improve the accuracy of theoretical line loss calculations. Since Distributed Generation (DG) access to the distribution network causes variability of power flow in the distribution network within a short period, the error of the traditional line loss calculation method increases. For the line loss calculation of medium-voltage distribution networks containing DGs with high-density collection data, a continuous line loss calculation method for the distribution network was proposed, aiming at improving the accuracy compared with the traditional line loss calculation method. The proposed method makes full use of the high-density collection data on the dispatch side and DG side, distributing the supply power to each load node by power to calculate real-time power flow, thus obtaining a more credible line loss value. The effectiveness and accuracy of the proposed method were verified in the IEEE 17-node distribution system.


  • Open Access

    Line Loss Interval Algorithm for Distribution Network with DG Based on Linear Optimization under Abnormal or Missing Measurement Data

    by Chen Liang, Chang Chen, Weizhou Wang, Xiping Ma, Yuying Li, Tong Jiang

    Data collection is more difficult in distribution network than transmission networks since the structure of distribution networks is more complex. As a result, data could be partly abnormal or missing, which cannot completely describe the operation status of distribution network. In addition, access of distributed generation (DG) to distribution network further aggravates the variability of power flow in distribution network. The traditional deterministic line loss calculation method has some limitations in accurately estimating the line loss of distribution network with DG. A line loss interval calculation method based on power flow calculation and linear optimization is proposed, considering abnormal data collection and distribution network power flow variability. The linear optimization model is established according to sensitivity of line loss to the injected power and sensitivity of transmission power of first branch to the injected power. Introducing the scheduling information into the optimization model, a reliable line loss fluctuation interval can be obtained which actual line loss locates. The effectiveness of the proposed algorithm is verified in IEEE 33-bus distribution network system.


  • Open Access

    Optimal Planning of Integrated Energy Systems Based on Coupled CCHP

    by Xiaofeng Dong, Chao Quan, Tong Jiang

    With the widespread attention on clean energy use and energy efficiency, the integrated energy system (IES) has received considerable research and development. This paper proposed an electricity-gas IES optimization planning model based on a coupled combined cooling heating and power system (CCHP). The planning and operation of power lines and gas pipelines are considered. Regarding CCHP as the coupled hub of an electricity-gas system, the proposed model minimizes total cost in IES, with multistage planning and multi-scene analyzing. Renewable energy generation is also considered, including wind power generation and photovoltaic power generation. The numerical results reveal the replacing and adding schemes of power lines and gas pipelines, the optimal location and capacity of CCHP. In comparison with conventional separation production (SP), the optimization model which regards CCHP as the coupled hub attains better economy. At the same time, the influence of electricity price and natural gas price on the quantities of purchasing electricity and purchasing gas in the CCHP system is analyzed. According to the simulation result, a benchmark gas price is proposed, which shows whether the CCHP system chooses power generation. The model results and discussion demonstrate the validity of the model.


  • Open Access

    Adaptive Consensus Algorithm for Distributed Heat-Electricity Energy Management of an Islanded Microgrid

    by Xiaofeng Dong, Xiaoshun Zhang, Tong Jiang

    This paper proposes a novel adaptive consensus algorithm (ACA) for distributed heat-electricity energy management (HEEM) of an islanded microgrid. In order to simultaneously satisfy the heat-electricity energy balance constraints, ACA is implemented with a switch between unified consensus and independent consensus according to the dynamic energy mismatches. The feasible operation region of a combined heat and power (CHP) unit is decomposed into eight searching sub-regions, thus its electricity and heat energy outputs can simultaneously match the incremental cost consensus requirement and the heat-electricity energy balance constraints. Case studies are thoroughly carried out to verify the performance of ACA for distributed HEEM of an islanded microgrid.


  • Open Access

    Adaptive Hydraulic Potential Energy Transfer Technology and Its Application to Compressed Air Energy Storage

    by Hao Fu, Tong Jiang, Yan Cui, Bin Li

    In recent years, Hydro-pneumatic cycling compressed air energy storage (HC-CAES) has become an important topic in compressed air energy storage (CAES) technology research. In HC-CAES, air is compressed by liquid and driven by electrical equipment when energy is stored, and then, liquid is used to drive the water conservancy equipment to generate electricity. In this study, adaptive hydraulic potential energy transfer technology is proposed to solve a series of problems in the HC-CAES system, including the high fluctuation range of gas potential energy, poor operating stability, low efficiency, and so on. Therefore, fluctuating potential energy can be stably transferred through the variable area hydraulic devices, which can be controlled with an on–off valve. The structure and operation scheme of the adaptive hydraulic potential energy transfer device used in the HC-CAES system are explained in detail; the device can provide a stable water head range for the highly efficient operation of water conservancy equipment. Moreover, an optimal operation scheme was determined through simulation analysis; a physical experiment platform was built to verify the feasibility of the design and stability of system operation.


  • Open Access

    A Quantitative Profit Analysis of Power Grid with Grid-connected Wind Power

    by Jia Lin, Zhao Yu, Dayong Yu, Dongxue Li, Tong Jiang