Hyeong Jae Lee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Hyeong Jae Lee has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Shyh-Shiuh Lih
Jet Propulsion Lab. (United States)
3 shared publications - Yoseph Bar-Cohen
California Institute of Technology
3 shared publications - Mircea Badescu
NASA/Jet Propulsion Laboratory, California Institute of Technology, Pasadena, CA 91109, USA
1 shared publication Nobuyuki Takano
Jet Propulsion Lab. (United States)
1 shared publication- Xiaoqi Bao
Jet Propulsion Lab. (United States)
1 shared publication
Latest Publications
- 28 May 2018
- Published by ASME International in Journal of Nondestructive Evaluation, Diagnostics and Prognostics of Engineering Systems
- Vol. 1 (3) , 031008
Development and Testing of a Multitransducer System for Measuring Height of Condensed Water in Steam Pipes With Steady-State and Turbulent Flow Conditions
A system consisting of a multiplexer and multiple ultrasonic probes was developed for in situ monitoring of the water condensation height in steam pipes under steady-state and turbulent flow conditions. The measurement method, the signal processing techniques, the experimental setup, and the test results are presented in this paper. The feasibility and efficiency of the developed multitransducers and signal processing algorithms were demonstrated. The measured water height and wave pattern in dynamic surface conditions inside the pipe were verified through the snapshot of the recorded video images. The developed methodology built the framework for the use of multiple transducers array ultrasonic system for practical application to in situ monitor the water height in steam pipes.
- 28 May 2018
- Published by ASME International in Journal of Nondestructive Evaluation, Diagnostics and Prognostics of Engineering Systems
- Vol. 1 (3) , 031008
Development and Testing of a Multitransducer System for Measuring Height of Condensed Water in Steam Pipes With Steady-State and Turbulent Flow Conditions
A system consisting of a multiplexer and multiple ultrasonic probes was developed for in situ monitoring of the water condensation height in steam pipes under steady-state and turbulent flow conditions. The measurement method, the signal processing techniques, the experimental setup, and the test results are presented in this paper. The feasibility and efficiency of the developed multitransducers and signal processing algorithms were demonstrated. The measured water height and wave pattern in dynamic surface conditions inside the pipe were verified through the snapshot of the recorded video images. The developed methodology built the framework for the use of multiple transducers array ultrasonic system for practical application to in situ monitor the water height in steam pipes.
- 1 April 2016
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9805, 980510
In-situ measurement of the height of condensed water in steam pipes with dynamic flow
A method based on the use of enhanced filtered Hilbert envelope of the wave signal was developed in order to monitor the height of condensed water through the wall of steam pipes having dynamic flow conditions. A prototype testbed was designed and fabricated in this study to simulate the dynamic flow conditions including the air stream flowing above the water and bubble induced disturbance. A dual-transducer was used to perform the test as a basis for the multiple transducers system to facilitate the detectability and reliability for long term monitoring of the condensed water height in dynamic conditions. The results demonstrated that the method of measuring the water height using multiple-transducer system employing the developed novel signal processing technique is an efficient and accurate tool for practical applications. © (2016) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
- 1 April 2016
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9805, 980510
In-situ measurement of the height of condensed water in steam pipes with dynamic flow
A method based on the use of enhanced filtered Hilbert envelope of the wave signal was developed in order to monitor the height of condensed water through the wall of steam pipes having dynamic flow conditions. A prototype testbed was designed and fabricated in this study to simulate the dynamic flow conditions including the air stream flowing above the water and bubble induced disturbance. A dual-transducer was used to perform the test as a basis for the multiple transducers system to facilitate the detectability and reliability for long term monitoring of the condensed water height in dynamic conditions. The results demonstrated that the method of measuring the water height using multiple-transducer system employing the developed novel signal processing technique is an efficient and accurate tool for practical applications. © (2016) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
- 17 April 2013
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8695, 86950I
Advanced signal processing for high temperatures health monitoring of condensed water height in steam pipes
An advanced signal processing methodology is being developed to monitor the height of condensed water thru the wall of a steel pipe while operating at temperatures as high as 250°C. Using existing techniques, previous study indicated that, when the water height is low or there is disturbance in the environment, the predicted water height may not be accurate. In recent years, the use of the autocorrelation and envelope techniques in the signal processing has been demonstrated to be a very useful tool for practical applications. In this paper, various signal processing techniques including the auto correlation, Hilbert transform, and the Shannon Energy Envelope methods were studied and implemented to determine the water height in the steam pipe. The results have shown that the developed method provides a good capability for monitoring the height in the regular conditions. An alternative solution for shallow water or no water conditions based on a developed hybrid method based on Hilbert transform (HT) with a high pass filter and using the optimized windowing technique is suggested. Further development of the reported methods would provide a powerful tool for the identification of the disturbances of water height inside the pipe.
- 17 April 2013
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8695, 86950I
Advanced signal processing for high temperatures health monitoring of condensed water height in steam pipes
An advanced signal processing methodology is being developed to monitor the height of condensed water thru the wall of a steel pipe while operating at temperatures as high as 250°C. Using existing techniques, previous study indicated that, when the water height is low or there is disturbance in the environment, the predicted water height may not be accurate. In recent years, the use of the autocorrelation and envelope techniques in the signal processing has been demonstrated to be a very useful tool for practical applications. In this paper, various signal processing techniques including the auto correlation, Hilbert transform, and the Shannon Energy Envelope methods were studied and implemented to determine the water height in the steam pipe. The results have shown that the developed method provides a good capability for monitoring the height in the regular conditions. An alternative solution for shallow water or no water conditions based on a developed hybrid method based on Hilbert transform (HT) with a high pass filter and using the optimized windowing technique is suggested. Further development of the reported methods would provide a powerful tool for the identification of the disturbances of water height inside the pipe.