Denisa Rusinaru
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Denisa Rusinaru has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
Adrian Cojoaca
Oltenia Distribution, Craiova, Romania
3 shared publicationsClaudiu Popirlan
University of Craiova, INCESA (Research Hub for, Applied Sciences), 107 Decebal Bld, 200440 Craiova, Romania
3 shared publicationsGabriel Cosmin Buzatu
University of Craiova, Faculty of Electrical Engineering, INCESA, 107 Decebal Blvd, 200440 Craiova, Romania
3 shared publicationsLeonardo Geo Manescu
University of Craiova, INCESA (Research Hub for, Applied Sciences), 107 Decebal Bld, 200440 Craiova, Romania
3 shared publicationsMarian Ciontu
University of Craiova, Faculty of Electrical Engineering, INCESA, 107 Decebal Blvd, 200440 Craiova, Romania
3 shared publications- Gabriel Stoian
University of Craiova
2 shared publications
Latest Publications
- Open Access
- 5 October 2018
- Published by EDP Sciences in MATEC Web of Conferences
- Vol. 210, 02045
Extended Capabilities of the Power Quality Management System of the Power Distribution Grid for Data Exchange
The actual operation of the power distribution systems asks for high power quality (PQ). This fully justifies the investments in improving the metrics of power grid performances. But maintaining a PQ data infrastructure in a numerous locations is time-consuming and prohibitive. Moreover, each PQ monitor releases its own data format. These considerations justified using of a central PQ management system able to manipulate elliptical and time discontinuous information. The paper presents the characteristics of a webbased application designed to collect the data measured with different technologies of monitors and translate them into a common PQ data interchange format allowing comprehensive and long-duration grid operation assessment. The unitary formatted data generated by this customized software tool can be further processed by a proprietary software platform for PQ management owned by the network operator. The present version of this conversion tool is applicable only for one product family operating in the local power distribution grid. Further development is planned for integrating other two monitor vendors/families.
- 5 October 2018
- Published by EDP Sciences in MATEC Web of Conferences
- Vol. 210, 02045
Open AccessExtended Capabilities of the Power Quality Management System of the Power Distribution Grid for Data Exchange
The actual operation of the power distribution systems asks for high power quality (PQ). This fully justifies the investments in improving the metrics of power grid performances. But maintaining a PQ data infrastructure in a numerous locations is time-consuming and prohibitive. Moreover, each PQ monitor releases its own data format. These considerations justified using of a central PQ management system able to manipulate elliptical and time discontinuous information. The paper presents the characteristics of a webbased application designed to collect the data measured with different technologies of monitors and translate them into a common PQ data interchange format allowing comprehensive and long-duration grid operation assessment. The unitary formatted data generated by this customized software tool can be further processed by a proprietary software platform for PQ management owned by the network operator. The present version of this conversion tool is applicable only for one product family operating in the local power distribution grid. Further development is planned for integrating other two monitor vendors/families.
- Open Access
- 5 October 2018
- Published by EDP Sciences in MATEC Web of Conferences
- Vol. 210, 02054
Impact analysis of changing the neutral treatment solution in an MV electrical station on the system performance
The actual operation of the power distribution systems asks for high standards concerning the performance of the system in terms of continuity and safety in supplying consumers on the one hand and the quality of the delivered energy on the other hand. Thus, the paper aims to present a complete analysis of the impact that the modification of the neutral treatment system in a 110 kV / MV station belonging to Energy Distribution Oltenia (DEO), has on both the number and the type of unwanted events or phenomena as well as on the network parameters and the transient regime which occurs as a result of some defects with the earth. All of these have been analyzed taking into account the new performance standards that distribution systems have to respect.
- 5 October 2018
- Published by EDP Sciences in MATEC Web of Conferences
- Vol. 210, 02054
Open AccessImpact analysis of changing the neutral treatment solution in an MV electrical station on the system performance
The actual operation of the power distribution systems asks for high standards concerning the performance of the system in terms of continuity and safety in supplying consumers on the one hand and the quality of the delivered energy on the other hand. Thus, the paper aims to present a complete analysis of the impact that the modification of the neutral treatment system in a 110 kV / MV station belonging to Energy Distribution Oltenia (DEO), has on both the number and the type of unwanted events or phenomena as well as on the network parameters and the transient regime which occurs as a result of some defects with the earth. All of these have been analyzed taking into account the new performance standards that distribution systems have to respect.
- Open Access
- 30 August 2018
- Published by Academy and Industry Research Collaboration Center (AIRCC) in International Journal of Computer Science and Information Technology
- Vol. 10 (4) , 01-12
Application Development to Convert Heterogeneous Information into PQDIF (Power Quality Data Interchange Format)
- 30 August 2018
- Published by Academy and Industry Research Collaboration Center (AIRCC) in International Journal of Computer Science and Information Technology
- Vol. 10 (4) , 01-12
Open AccessApplication Development to Convert Heterogeneous Information into PQDIF (Power Quality Data Interchange Format)
- 30 July 2018
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1982 (1) , 020003
Estimation of the maximum permissible injections of the distributed generation in the LV networks based on power quality considerations
The operation of a power distribution system with a large number of distributed generation units copes with problems as voltage rising, short-circuit currents increasing, changes of power losses or power quality and reliability problems. When considering these issues, it is important to take into account that existing power network regulatory framework are presently set for the one-way model. The power distribution grids operator can make decisions related to the distributed generation units’ integration by estimating the maximum value of these units’ capacity that can be tolerated by the distribution grid without violating its operational constraints. The paper presents an approach to quantify the technical impacts of small power generation units embedded in low voltage (LV) grids. The analysis is based on a methodology that estimates the limits by relating to a CIGRE benchmark grid.
- 30 July 2018
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1982 (1) , 020003
Estimation of the maximum permissible injections of the distributed generation in the LV networks based on power quality considerations
The operation of a power distribution system with a large number of distributed generation units copes with problems as voltage rising, short-circuit currents increasing, changes of power losses or power quality and reliability problems. When considering these issues, it is important to take into account that existing power network regulatory framework are presently set for the one-way model. The power distribution grids operator can make decisions related to the distributed generation units’ integration by estimating the maximum value of these units’ capacity that can be tolerated by the distribution grid without violating its operational constraints. The paper presents an approach to quantify the technical impacts of small power generation units embedded in low voltage (LV) grids. The analysis is based on a methodology that estimates the limits by relating to a CIGRE benchmark grid.