SRStefan Raufer

Stefan Raufer

*This is an algorithmically generated author record based on publicly available information.

Stefan Raufer has a total of 32 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Development and Evaluation of a Realistic Audio-Visual Multi-Talker Speech Comprehension Test

    by Xinyu Guo, Rebecca Holt, Kelly Miles, Ronny Kurniawan Ibrahim, Stefan Raufer, Peter Derleth, Joerg M. Buchholz

    Current speech comprehension assessments do not provide a reliable measure of listeners’ real-life speech comprehension ability, as they fail to capture the complexity and dynamic nature of real-world communicative scenarios. To better align laboratory assessment with real-world listening demands, we developed a new speech comprehension test using audio-visual recordings of spontaneous conversations between two talkers. The conversations were combined with babble noise at three different signal-to-noise ratios (SNRs) to vary task difficulty (Quiet, 0dB, and -5dB). Speech comprehension was assessed using a word monitoring paradigm, in which listeners were given a word category and responded to target words related to that category by pressing a hand-held button. Outcome measures included self-rated listening effort, hit rate, response time (RT), and head turn behavior. Thirty adults with normal hearing were tested. With decreasing SNR, self-reported listening effort increased, hit rate decreased, and RT increased. Participants predominantly oriented toward the active talker, with visual localization achieved through a combination of head and eye movements. Dynamic analyses around conversational floor transfers revealed that, listeners oriented earlier and more consistently toward the upcoming talker in more challenging conditions. None of the behavioral measures were significantly associated with listening effort ratings after accounting for SNR effects. Overall, our results demonstrate that the proposed test provides a sensitive measure of real-world speech comprehension and holds promise for assessing the impact of hearing loss and evaluating hearing device benefit in ecologically valid settings.

  • Open Access

    Output performance of the novel active transcutaneous bone conduction implant Sentio at different stimulation sites

    by Mohammad Ghoncheh, Stefan Stenfelt, Patrick Maas, Rolf Salcher, Nils Prenzler, Stefan Raufer, Hannes Maier


  • Anatomy of the Human Osseous Spiral Lamina and Cochlear Partition Bridge: Relevance for Cochlear Partition Motion

    by Stefan Raufer, Cornelia Idoff, Aleksandrs Zosuls, Giacomo Marino, Nathan Blanke, Irving J. Bigio, Jennifer T. O’mAlley, Barbara J. Burgess, Joseph B. Nadol, John J. Guinan, et al.

    The classic view of cochlear partition (CP) motion, generalized to be for all mammals, was derived from basal-turn measurements in laboratory animals. Recently, we reported motion of the human CP in the cochlear base that differs substantially from the classic view. We described a human soft tissue “bridge” (non-existent in the classic view) between the osseous spiral lamina (OSL) and basilar membrane (BM), and showed how OSL and bridge move in response to sound. Here, we detail relevant human anatomy to better understand the relationship between form and function. The bridge and BM have similar widths that increase linearly from base to apex, whereas the OSL width decreases from base to apex, leading to an approximately constant total CP width throughout the cochlea. The bony three-dimensional OSL microstructure, reconstructed from unconventionally thin, 2-μm histological sections, revealed thin, radially wide OSL plates with pores that vary in size, extent, and distribution with cochlear location. Polarized light microscopy revealed collagen fibers in the BM that spread out medially through the bridge to connect to the OSL. The long width and porosity of the OSL may explain its considerable bending flexibility. The similarity of BM and bridge widths along the cochlea, both containing continuous collagen fibers, may make them a functional unit and allow maximum CP motion near the bridge-BM boundary, as recently described. These anatomical findings may help us better understand the motion of the structures surrounding the organ of Corti and how they shape the input to the cochlear sensory mechanism.


  • Open Access

    Superior Canal Dehiscence Similarly Affects Cochlear Pressures in Temporal Bones and Audiograms in Patients

    by Y. Song Cheng, Stefan Raufer, Xiying Guan, Christopher F. Halpin, Daniel J. Lee, Hideko Heidi Nakajima

    Objectives: The diagnosis of superior canal dehiscence (SCD) is challenging and audiograms play an important role in raising clinical suspicion of SCD. The typical audiometric finding in SCD is the combination of increased air conduction (AC) thresholds and decreased bone conduction thresholds at low frequencies. However, this pattern is not always apparent in audiograms of patients with SCD, and some have hearing thresholds that are within the normal reference range despite subjective reports of hearing impairment. In this study, we used a human temporal bone model to measure the differential pressure across the cochlear partition (P Diff) before and after introduction of an SCD. P Diff estimates the cochlear input drive and provides a mechanical audiogram of the temporal bone. We measured P Diff across a wider frequency range than in previous studies and investigated whether the changes in P Diff in the temporal bone model and changes of audiometric thresholds in patients with SCD were similar, as both are thought to reflect the same physical phenomenon. Design: We measured P Diff across the cochlear partition in fresh human cadaveric temporal bones before and after creating an SCD. Measurements were made for a wide frequency range (20 Hz to 10 kHz), which extends down to lower frequencies than in previous studies and audiograms. P Diff = P SV- P ST is calculated from pressures measured simultaneously at the base of the cochlea in scala vestibuli (P SV) and scala tympani (P ST) during sound stimulation. The change in P Diff after an SCD is created quantifies the effect of SCD on hearing. We further included an important experimental control—by patching the SCD, to confirm that P Diff was reversed back to the initial state. To provide a comparison of temporal bone data to clinical data, we analyzed AC audiograms (250 Hz to 8kHz) of patients with symptomatic unilateral SCD (radiographically confirmed). To achieve this, we used the unaffected ear to estimate the baseline hearing function for each patient, and determined the influence of SCD by referencing AC hearing thresholds of the SCD-affected ear with the unaffected contralateral ear. Results: P Diff measured in temporal bones (n = 6) and AC thresholds in patients (n = 53) exhibited a similar pattern of SCD-related change. With decreasing frequency, SCD caused a progressive decrease in P Diff at low frequencies for all temporal bones and a progressive increase in AC thresholds at low frequencies. SCD decreases the cochlear input drive by approximately 6 dB per octave at frequencies below ~1 kHz for both P Diff and AC thresholds. Individual data varied in frequency and magnitude of this SCD effect, where some temporal-bone ears had noticeable effects only below 250 Hz. Conclusions: We found that with decrease in frequency the progressive decrease in low-frequency P Diff in our temporal bone experiments mirrors the progressive elevation in AC hearing thresholds observed in patients. This hypothesis remains to be tested in the clinical setting, but our findings suggest that that measuring AC thresholds at frequencies below 250 Hz would detect a larger change, thus improving audiograms as a diagnostic tool for SCD.


  • Cochlear partition anatomy and motion in humans differ from the classic view of mammals

    by Stefan Raufer, John J. Guinan, Hideko Heidi Nakajima

    Mammals detect sound through mechanosensitive cells of the cochlear organ of Corti that rest on the basilar membrane (BM). Motions of the BM and organ of Corti have been studied at the cochlear base in various laboratory animals, and the assumption has been that the cochleas of all mammals work similarly. In the classic view, the BM attaches to a stationary osseous spiral lamina (OSL), the tectorial membrane (TM) attaches to the limbus above the stationary OSL, and the BM is the major moving element, with a peak displacement near its center. Here, we measured the motion and studied the anatomy of the human cochlear partition (CP) at the cochlear base of fresh human cadaveric specimens. Unlike the classic view, we identified a soft-tissue structure between the BM and OSL in humans, which we name the CP “bridge.” We measured CP transverse motion in humans and found that the OSL moved like a plate hinged near the modiolus, with motion increasing from the modiolus to the bridge. The bridge moved almost as much as the BM, with the maximum CP motion near the bridge–BM connection. BM motion accounts for 100% of CP volume displacement in the classic view, but accounts for only 27 to 43% in the base of humans. In humans, the TM–limbus attachment is above the moving bridge, not above a fixed structure. These results challenge long-held assumptions about cochlear mechanics in humans. In addition, animal apical anatomy (in SI Appendix) doesn’t always fit the classic view. Significance Basic properties of hearing such as its sensitivity and frequency tuning arise from the mechanical responses in the cochlea. Such responses have been measured extensively in the cochlear base of laboratory mammals, and our understanding of human cochlear mechanics is largely founded on the assumption that cochlear mechanics is similar in all mammals. Here we show that the anatomy and motion of the human cochlear partition differ in crucial ways from the generalized classic view of mammalian cochlear mechanics. Our results call into question this classic view. Establishing the features of human cochlear anatomy and function is important for understanding human hearing and for comparison with results from laboratory animals.


  • Infrasound transmission in the human ear: Implications for acoustic and vestibular responses of the normal and dehiscent inner ear

    by Stefan Raufer, Salwa F. Masud, Hideko H. Nakajima

    The transmission of infrasound within the human ear is not well understood. To investigate infrasound propagation through the middle and inner ear, velocities of the stapes and round window membrane were measured to very low frequencies (down to 0.9 Hz from 2000 Hz) in fresh cadaveric human specimens. Results from ear-canal sound stimulation responses show that below 200 Hz, the middle ear impedance is dominated by its stiffness term, limiting sound transmission to the inner ear. During air-conduction, normal ears have approximately equal volume velocities at the oval (stapes) and round windows, known as a two-window system. However, perturbing the impedance of the inner ear with a superior canal dehiscence (SCD), a pathological opening of the bone surrounding the semicircular canal, breaks down this simple two-window system. SCD changes the volume velocity flow in the inner ear, particularly at low frequencies. The experimental findings and model predictions in this study demonstrate that low-frequency auditory and vestibular sound transmission can be affected by a change in the inner-ear impedance due to a SCD.


  • Open Access

    The effect of middle ear cavity and superior canal dehiscence on wideband acoustic immittance in fresh human cadaveric specimens

    by Salwa F. Masud, Stefan Raufer, Stephen T. Neely, Hideko H. Nakajima

    Superior canal dehiscence (SCD) is a hole in the bony wall of the superior semicircular canal, which can cause various auditory and/or vestibular symptoms and can result in wrong and/or delayed diagnosis. Wideband acoustic immittance (WAI) can potentially distinguish various mechanical middle-ear pathologies as well as inner-ear pathologies non-invasively. We found that in patients, SCD was commonly associated with a narrow-band decrease in power reflectance (PR, derived from WAI) near 1 kHz. Because clinical data has large variation across individual ears and because we do not know the individual “normal” state prior to SCD, we measured WAI in five fresh temporal bone specimens to determine the effects of SCD with respect to the normal state. In temporal bone, we measured PR to assess mechanical changes before and after SCD, as well as to assess the effect of an open or closed middle-ear cavity. After SCD, PR had a consistent decrease between 0.48 and 0.76 kHz, and a slight increase between 1.04 and 1.4 kHz in the open cavity condition. However, in several experiments, we observed low PR around 1 kHz in the normal state before SCD, likely due to the specimen’s open middle ear cavity (MEC). Because we see effects of both SCD and open MEC around 1 kHz, some of the SCD effect can be masked by the effect of the MEC in the temporal bone specimens. To compensate for this MEC effect, we estimated the effect of SCD in a closed MEC case, but the effect did not differ significantly from the measured open MEC. This study demonstrates the limitation of temporal bone experiments with open MEC when studying inner-ear lesions with WAI.

  • Impedance measurements of the human cochlear partition

    by Stefan Raufer, Hideko H. Nakajima

    The cochlea is a mechanical frequency analyzer, owing its characteristics to the impedance of the cochlear partition. In humans, the impedance of the partition has not been measured directly, and estimates of the stiffness (a principal component of the impedance) are based on loose assumptions. In this study, we examine not only the stiffness of the basilar membrane (BM), but also the osseous spiral lamina (OSL), which, in human, vibrates substantially. We hypothesize that the OSL contributes significantly to the volume stiffness of the cochlear partition (CP). We measured velocities of the BM and OSL at different radial locations 1 mm from the base of the cochlea in a fresh human cadaveric specimen. Simultaneously, we measured intracochlear pressures on the other side of the partition, in scala vestibuli. With the velocity and pressure measurements we can estimate the specific acoustic impedance of the BM and OSL (Z = p/v). At frequencies well below the resonant frequency, the stiffness of these structures can be extracted by multiplying the impedance by the radian frequency. The specific acoustic stiffness was found to be 1.2 GPa/m on the BM, 6 GPa/m at the juncture where the BM attaches to the OSL, and 10 GPa/m at the midpoint of the OSL. A beam model, appropriate to model the radial motion of the BM in guinea pig or gerbil, cannot describe the displacement of the human CP in the base. Instead, we find that the OSL is hinged near the modiolus and vibrates significantly near the connection to the more compliant BM, contributing greatly the volume compliance of the CP.