Marc Lubnow
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Marc Lubnow has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Christof Schulz
University of Duisburg-Essen
5 shared publications - Thomas Dreier
EMPI-RF, Institute for Energy and Materials Processes-Reactive Fluids, University of Duisburg-Essen, Duisburg, Germany
5 shared publications Torsten Endres
Univ Duisburg Essen, Inst Energy & Mat Proc React Fluids, EMPI, D-47048 Duisburg, Germany
2 shared publicationsJay B. Jeffries
High Temperature Gas Dynamics Laboratory, Stanford University, Stanford, California, USA
1 shared publication
Latest Publications
- 17 April 2023
- Published by Optica Publishing Group in Applied Optics
- Vol. 62 (12) , 3169-3175
Water-film thickness imaging based on time-multiplexed near-infrared absorption with up to 500 Hz repetition rate
We demonstrate high-repetition-rate imaging of the liquid-film thickness in the 50–1000 µm range resulting from impinging water droplets on a glass surface. The pixel-by-pixel ratio of line-of-sight absorption at two time-multiplexed near-infrared wavelengths at 1440 and 1353 nm was detected with a high-frame-rate InGaAs focal-plane array camera. Frame rates of 1 kHz and thus measurement rates of 500 Hz could be achieved, well suited to capture the fast dynamics of droplet impingement and film formation. The droplets were sprayed onto the glass surface using an atomizer. Suitable absorption wavelength bands for water droplet/film imaging were determined from Fourier-transform infrared (FTIR) spectra of pure water between 298 and 338 K. At 1440 nm, the water absorption is nearly temperature-independent, making the measurements robust against temperature fluctuations. Time-resolved imaging measurements capturing the dynamics of the water droplet impingement and evolution were successfully demonstrated.
- 17 April 2023
- Published by Optica Publishing Group in Applied Optics
- Vol. 62 (12) , 3169-3175
Water-film thickness imaging based on time-multiplexed near-infrared absorption with up to 500 Hz repetition rate
We demonstrate high-repetition-rate imaging of the liquid-film thickness in the 50–1000 µm range resulting from impinging water droplets on a glass surface. The pixel-by-pixel ratio of line-of-sight absorption at two time-multiplexed near-infrared wavelengths at 1440 and 1353 nm was detected with a high-frame-rate InGaAs focal-plane array camera. Frame rates of 1 kHz and thus measurement rates of 500 Hz could be achieved, well suited to capture the fast dynamics of droplet impingement and film formation. The droplets were sprayed onto the glass surface using an atomizer. Suitable absorption wavelength bands for water droplet/film imaging were determined from Fourier-transform infrared (FTIR) spectra of pure water between 298 and 338 K. At 1440 nm, the water absorption is nearly temperature-independent, making the measurements robust against temperature fluctuations. Time-resolved imaging measurements capturing the dynamics of the water droplet impingement and evolution were successfully demonstrated.
- 3 November 2021
- Published by Optica Publishing Group in Applied Optics
- Vol. 60 (32) , 10087-10093
Simultaneous measurement of liquid-film thickness and solute concentration of aqueous solutions of two urea derivatives using NIR absorption
We present a method to simultaneously measure the film thickness and individual concentrations of two urea derivates (urea C H 4 N 2 O and dimethylurea C 3 H 8 N 2 O ) mixed in an aqueous solution at constant temperature using near-infrared (NIR) absorption at multiple specific wavelengths. Fourier transform infrared (FTIR) spectra of aqueous mixtures of urea and dimethylurea solutions were recorded in the 1250–2500 nm wavelength range in thin-layer quartz cuvettes at room temperature. The spectra reveal suitable detection wavelengths, i.e., 1450, 1933, 2200, and 2270 nm, for which both the absorption coefficient and its variation with the species concentration are large enough to achieve satisfactory detection sensitivity and selectivity. For validation measurements, samples were prepared in thin-layer quartz transmission cells with known path lengths and mixture compositions in the range 100–1000 µm and 0–40 wt.%, respectively. Film thickness and mass fractions of both species were determined from measured absorbance ratios in the determined characteristic wavelength bands.
- 3 November 2021
- Published by Optica Publishing Group in Applied Optics
- Vol. 60 (32) , 10087-10093
Simultaneous measurement of liquid-film thickness and solute concentration of aqueous solutions of two urea derivatives using NIR absorption
We present a method to simultaneously measure the film thickness and individual concentrations of two urea derivates (urea C H 4 N 2 O and dimethylurea C 3 H 8 N 2 O ) mixed in an aqueous solution at constant temperature using near-infrared (NIR) absorption at multiple specific wavelengths. Fourier transform infrared (FTIR) spectra of aqueous mixtures of urea and dimethylurea solutions were recorded in the 1250–2500 nm wavelength range in thin-layer quartz cuvettes at room temperature. The spectra reveal suitable detection wavelengths, i.e., 1450, 1933, 2200, and 2270 nm, for which both the absorption coefficient and its variation with the species concentration are large enough to achieve satisfactory detection sensitivity and selectivity. For validation measurements, samples were prepared in thin-layer quartz transmission cells with known path lengths and mixture compositions in the range 100–1000 µm and 0–40 wt.%, respectively. Film thickness and mass fractions of both species were determined from measured absorbance ratios in the determined characteristic wavelength bands.
- 31 May 2019
- Published by Optica Publishing Group in Applied Optics
- Vol. 58 (16) , 4546-4552
NIR sensor for aqueous urea solution film thickness and concentration measurement using a broadband light source
We demonstrate a multi-wavelength near-infrared (NIR) broadband absorption sensor for the simultaneous monitoring of layer thickness and urea concentration of aqueous urea solutions. Samples were prepared in thin-layer quartz transmission cells. Film thickness and urea mass fraction (at constant temperature) were determined from measured transmittance ratios in characteristic wavelength bands selected by narrowband filters in front of the detector and converted to absorbance ratios. Suitable emission bands were selected depending on the sensitivity of the NIR absorption spectrum of the solution with respect to temperature and solute concentration. For this purpose, Fourier transform IR spectra of aqueous urea solutions were recorded in the 1250–2500 nm wavelength range for urea concentrations between 0 and 40 wt.% and temperatures between 298 K and 338 K. A prototype sensor was designed using a continuous-wave fiber-coupled incoherent tungsten lamp, subsequent intensity modulation, and lock-in detection of the transmitted radiation. The sensor concept was validated with measurements using a calibration cell providing liquid layers of variable thicknesses (7–1000 μm).
- 31 May 2019
- Published by Optica Publishing Group in Applied Optics
- Vol. 58 (16) , 4546-4552
NIR sensor for aqueous urea solution film thickness and concentration measurement using a broadband light source
We demonstrate a multi-wavelength near-infrared (NIR) broadband absorption sensor for the simultaneous monitoring of layer thickness and urea concentration of aqueous urea solutions. Samples were prepared in thin-layer quartz transmission cells. Film thickness and urea mass fraction (at constant temperature) were determined from measured transmittance ratios in characteristic wavelength bands selected by narrowband filters in front of the detector and converted to absorbance ratios. Suitable emission bands were selected depending on the sensitivity of the NIR absorption spectrum of the solution with respect to temperature and solute concentration. For this purpose, Fourier transform IR spectra of aqueous urea solutions were recorded in the 1250–2500 nm wavelength range for urea concentrations between 0 and 40 wt.% and temperatures between 298 K and 338 K. A prototype sensor was designed using a continuous-wave fiber-coupled incoherent tungsten lamp, subsequent intensity modulation, and lock-in detection of the transmitted radiation. The sensor concept was validated with measurements using a calibration cell providing liquid layers of variable thicknesses (7–1000 μm).
- Open Access
- 31 July 2018
- Published by Optica Publishing Group in Optics Express
- Vol. 26 (16) , 20902-20912
Water film thickness imaging based on time-multiplexed near-infrared absorption
We demonstrate the imaging of the thickness of liquid water thin films in the 100–1500 µm range at a constant temperature by monitoring the pixel-by-pixel ratio of absorbance at two near-infrared (NIR) wavelengths near 1400 nm detected with a fast framing InGaAs focal-plane array camera. Experiments were performed in reflection mode with films of pure water and water/ethanol mixtures supported on opaque surfaces using two illumination–detection configurations. One scheme uses specular reflection of incident and reflected linearly polarized diode-laser light at Brewster’s angle, which enables detection of signal light that has twice traversed the liquid film with negligible interference from unwanted partial reflections of the incoming beams at the front surface interfaces (air/window and window/water for films constrained by a cover plate or air/water for free-standing films). The second configuration located the detection camera perpendicular above the surface where the detected light was transmitted through the sample and diffusely scattered from the support surface. Imaging measurements of film thickness using both configurations were successfully demonstrated. Time-resolved measurements capture the dynamics of flowing water films or waves generated by droplet impingement.
- 31 July 2018
- Published by Optica Publishing Group in Optics Express
- Vol. 26 (16) , 20902-20912
Open AccessWater film thickness imaging based on time-multiplexed near-infrared absorption
We demonstrate the imaging of the thickness of liquid water thin films in the 100–1500 µm range at a constant temperature by monitoring the pixel-by-pixel ratio of absorbance at two near-infrared (NIR) wavelengths near 1400 nm detected with a fast framing InGaAs focal-plane array camera. Experiments were performed in reflection mode with films of pure water and water/ethanol mixtures supported on opaque surfaces using two illumination–detection configurations. One scheme uses specular reflection of incident and reflected linearly polarized diode-laser light at Brewster’s angle, which enables detection of signal light that has twice traversed the liquid film with negligible interference from unwanted partial reflections of the incoming beams at the front surface interfaces (air/window and window/water for films constrained by a cover plate or air/water for free-standing films). The second configuration located the detection camera perpendicular above the surface where the detected light was transmitted through the sample and diffusely scattered from the support surface. Imaging measurements of film thickness using both configurations were successfully demonstrated. Time-resolved measurements capture the dynamics of flowing water films or waves generated by droplet impingement.
- 1 January 2018
- Published by Optica Publishing Group
- p. LW2C.3
Water Film Thickness Imaging based on Time-Multiplexed Near-Infrared Absorption
We demonstrate the imaging of water film thickness at constant temperature by exploiting absorbance ratios of near-infrared (NIR) radiation at two wavelengths in the water absorption spectrum around 1400 nm with light delivered by diode lasers and signal registered by a fast framing InGaAs focal plane array camera. Measurements are performed in reflection mode from opaque film support surfaces.
- 1 January 2018
- Published by Optica Publishing Group
- p. LW2C.3
Water Film Thickness Imaging based on Time-Multiplexed Near-Infrared Absorption
We demonstrate the imaging of water film thickness at constant temperature by exploiting absorbance ratios of near-infrared (NIR) radiation at two wavelengths in the water absorption spectrum around 1400 nm with light delivered by diode lasers and signal registered by a fast framing InGaAs focal plane array camera. Measurements are performed in reflection mode from opaque film support surfaces.