Kiara Serafini Dapieve
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Kiara Serafini Dapieve has a total of 53 co-authors. Here are the top co-authors by number of shared publications:
- Luiz Felipe Valandro
MSciD-PhD Post-Graduate Program in Oral Science, Faculty of Odontology, Federal University of Santa Maria, Santa Maria, Rio Grande do Sul, Brazil
30 shared publications - Gabriel Kalil Rocha Pereira
Graduate Program in Dental Sciences Federal University of Santa Maria (UFSM) Santa Maria Rio Grande do Sul Brazil
27 shared publications - Andressa Borin Venturini
Faculty of Odontology, Federal University of Santa Maria, Santa Maria, Rio Grande do Sul, Brazil
11 shared publications - Renan Vaz Machry
Department of Restorative Dentistry, Federal University of Minas Gerais (UFMG), Belo Horizonte, Minas Gerais, Brazil; Department of Restorative Dentistry (Prosthodontic Unit), Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil
11 shared publications - Cornelis Johannes Kleverlaan
Department of Dental Materials Science, Academic Centre for Dentistry Amsterdam (ACTA), Universiteit van Amsterdam and Vrije Universiteit, Amsterdam, Noord-Holland, the Netherlands
9 shared publications - Helder Callegaro Velho
Federal University of Santa Maria, Brazil
6 shared publications
Latest Publications
- Open Access
- 1 January 2024
- Published by FapUNIFESP (SciELO) in Brazilian Oral Research
- Vol. 38, e027
Fatigue behavior of sintered, glazed and glass-infiltrated surfaces of 5Y-PSZ bonded plates
This study evaluated the effect of different occlusal surface finishes (glaze and silica glass infiltration) on surface characteristics and fatigue behavior of partially stabilized zirconia (PSZ) plates adhesively bonded onto epoxy resin discs. PSZ disc specimens (n = 15; Katana blocks STML, Kuraray Noritake Dental) were produced (Ø = 10 mm; thickness = 1.2 mm) and allocated into 3 groups: As sintered (S), silica glass infiltration (SGI), and glaze application (G). The PSZ intaglio surface was air-abraded with 50-µm alumina powder followed by bonding agent application. All produced PSZ were adhesively cemented onto dentin analogue discs made of epoxy resin material (Ø = 10 mm; thickness = 2 mm). Step stress fatigue test was performed (load ranging from 200 to 1800 N; step size 100 N and 10,000 cycles; 20 Hz). The topographic, microstructural, and fractographic analyses were performed by scanning electron microscopy. Results: No statistically significant difference in fatigue behavior was detected among the groups. All failures started at the bonding surface. Silica glass-infiltration and glaze layer application provided a smoothing effect, while the sintered group had a surface with grooves. The occlusal surface finishing method (silica glass infiltration or glazing) had no deleterious effect on fatigue behavior of adhesively bonded PSZ plates.
- 1 January 2024
- Published by FapUNIFESP (SciELO) in Brazilian Oral Research
- Vol. 38, e027
Open AccessFatigue behavior of sintered, glazed and glass-infiltrated surfaces of 5Y-PSZ bonded plates
This study evaluated the effect of different occlusal surface finishes (glaze and silica glass infiltration) on surface characteristics and fatigue behavior of partially stabilized zirconia (PSZ) plates adhesively bonded onto epoxy resin discs. PSZ disc specimens (n = 15; Katana blocks STML, Kuraray Noritake Dental) were produced (Ø = 10 mm; thickness = 1.2 mm) and allocated into 3 groups: As sintered (S), silica glass infiltration (SGI), and glaze application (G). The PSZ intaglio surface was air-abraded with 50-µm alumina powder followed by bonding agent application. All produced PSZ were adhesively cemented onto dentin analogue discs made of epoxy resin material (Ø = 10 mm; thickness = 2 mm). Step stress fatigue test was performed (load ranging from 200 to 1800 N; step size 100 N and 10,000 cycles; 20 Hz). The topographic, microstructural, and fractographic analyses were performed by scanning electron microscopy. Results: No statistically significant difference in fatigue behavior was detected among the groups. All failures started at the bonding surface. Silica glass-infiltration and glaze layer application provided a smoothing effect, while the sintered group had a surface with grooves. The occlusal surface finishing method (silica glass infiltration or glazing) had no deleterious effect on fatigue behavior of adhesively bonded PSZ plates.
- Open Access
- 1 January 2024
- Published by FapUNIFESP (SciELO) in Brazilian Oral Research
- Vol. 38, e053
Effect of erosive conditions on different sealant materials used in paediatric dentistry
To evaluate the effect of acidic challenge on erosion depth and topographic characteristics of different materials used as occlusal sealants. Two hundred specimens of five sealant materials (Fuji IX, Ketac Molar, Fuji II, Equia and Clinpro) and forty bovine teeth enamel samples (control) were prepared and exposed to acidic challenge. The specimens were immersed in four different solutions (orange juice, coke drink, citric acid or distilled water) under mildly shaken conditions for 3 days. The erosion depth profiles were measured using a profilometer and Scanning Electron Microscope (SEM). Two-way ANOVA with Tukey post-hoc test was performed to evaluate the interactions. Sealant material and acidic challenge had significant effects on erosion depth. Among the materials, Fuji II presented the highest mean of erosion depth after immersion in orange juice, coke drink, and citric acid. All materials groups presented higher erosion depth values after immersion in the citric acid solution, except Clinpro. Bovine enamel presented higher erosion depth values compared to all materials when submitted to erosive challenge. Sealant materials submitted to the acidic challenge presented different degrees of erosion and topographic modification; however, they are less susceptible to erosion than bovine teeth enamel.
- 1 January 2024
- Published by FapUNIFESP (SciELO) in Brazilian Oral Research
- Vol. 38, e053
Open AccessEffect of erosive conditions on different sealant materials used in paediatric dentistry
To evaluate the effect of acidic challenge on erosion depth and topographic characteristics of different materials used as occlusal sealants. Two hundred specimens of five sealant materials (Fuji IX, Ketac Molar, Fuji II, Equia and Clinpro) and forty bovine teeth enamel samples (control) were prepared and exposed to acidic challenge. The specimens were immersed in four different solutions (orange juice, coke drink, citric acid or distilled water) under mildly shaken conditions for 3 days. The erosion depth profiles were measured using a profilometer and Scanning Electron Microscope (SEM). Two-way ANOVA with Tukey post-hoc test was performed to evaluate the interactions. Sealant material and acidic challenge had significant effects on erosion depth. Among the materials, Fuji II presented the highest mean of erosion depth after immersion in orange juice, coke drink, and citric acid. All materials groups presented higher erosion depth values after immersion in the citric acid solution, except Clinpro. Bovine enamel presented higher erosion depth values compared to all materials when submitted to erosive challenge. Sealant materials submitted to the acidic challenge presented different degrees of erosion and topographic modification; however, they are less susceptible to erosion than bovine teeth enamel.
- 21 December 2023
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 150, 106338
Characteristic fatigue strength and reliability of dental glass-ceramics: Effect of distinct surface treatments – Hydrofluoric acid etching and silane treatment vs one-step self-etching ceramic primer
- 21 December 2023
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 150, 106338
Characteristic fatigue strength and reliability of dental glass-ceramics: Effect of distinct surface treatments – Hydrofluoric acid etching and silane treatment vs one-step self-etching ceramic primer
- 25 July 2023
- Published by Springer Nature in Clinical Oral Investigations
- Vol. 27 (9) , 5539-5548
Fatigue behavior, failure mode, and stress distribution of occlusal veneers: influence of the prosthetic preparation cusp inclinations and the type of restorative material
Objective To evaluate the effects of cusp inclination of the prosthetic preparation’s occlusal surface and type of restorative material on the fatigue behavior, failure mode, and stress distribution of occlusal veneers. Materials and methods Glass fiber–reinforced epoxy resin prosthetic preparations for occlusal veneers with three different occlusal surface cusp inclination degrees (0°, 15°, and 30°) were produced and assigned into six testing groups (n = 11) according to the cusp inclination (0°, 15°, or 30°) and type of restorative material (lithium disilicate—LD or resin composite—RC). Despite different substrate preparation cusp inclination degrees, the restorations were designed maintaining 30° inclination between the cusps at the occlusal surface and a thickness of 0.7 mm at the central groove region of the restorations to be machined in a CAD/CAM system. After cementation, the specimens were stored for about 7 days (under water at 37 °C), and subsequently submitted to a load to failure test (n = 2) and an intermittent cyclic fatigue test (n = 9) (initial load: 100 N; step size: 50 N; cycles/step: 10,000; loading frequency: 20 Hz; loading piston: 6-mm-diameter stainless steel) until observing cracks. The data were analyzed by two-way ANOVA, Kaplan–Meier, and Mantel-Cox post hoc tests. Finite element analysis (FEA) and fractographic analyses were performed. Results The fatigue performance of LD and RC occlusal veneers was evaluated based on different prosthetic preparation cusp inclinations. The 0° inclination showed the best fatigue performance for both materials (LD: 944N, RC: 861N), while the 15° and 30° inclinations had lower values (LD: 800N and 533N, RC: 739N and 717N, respectively). The study also found that for a 0° inclination, LD occlusal veneers performed better than RC ones (LD: 944 N > RC: 861N), while for a 30° inclination, RC occlusal veneers had better fatigue performance than LD ones (LD: 533N < RC: 717N). No significant difference was observed between the materials for a 15° inclination (LD: 800N = RC: 739N). The FEA results showed a higher tensile stress concentration on lithium disilicate than on resin composite occlusal veneers. All lithium disilicate occlusal veneers showed radial crack failures, while resin composite occlusal veneers showed Hertzian cone cracks and radial cracks combined. Conclusion Considering mechanical perspective only, RC occlusal veneers should be indicated when prosthetic preparation cusps inclinations are 30°. When 0° prosthetic preparation cusps inclinations are observed, LD occlusal veneers will behave mechanically better. When a 15° cusp inclination is preserved, both restorative materials behave similarly.
- 25 July 2023
- Published by Springer Nature in Clinical Oral Investigations
- Vol. 27 (9) , 5539-5548
Fatigue behavior, failure mode, and stress distribution of occlusal veneers: influence of the prosthetic preparation cusp inclinations and the type of restorative material
Objective To evaluate the effects of cusp inclination of the prosthetic preparation’s occlusal surface and type of restorative material on the fatigue behavior, failure mode, and stress distribution of occlusal veneers. Materials and methods Glass fiber–reinforced epoxy resin prosthetic preparations for occlusal veneers with three different occlusal surface cusp inclination degrees (0°, 15°, and 30°) were produced and assigned into six testing groups (n = 11) according to the cusp inclination (0°, 15°, or 30°) and type of restorative material (lithium disilicate—LD or resin composite—RC). Despite different substrate preparation cusp inclination degrees, the restorations were designed maintaining 30° inclination between the cusps at the occlusal surface and a thickness of 0.7 mm at the central groove region of the restorations to be machined in a CAD/CAM system. After cementation, the specimens were stored for about 7 days (under water at 37 °C), and subsequently submitted to a load to failure test (n = 2) and an intermittent cyclic fatigue test (n = 9) (initial load: 100 N; step size: 50 N; cycles/step: 10,000; loading frequency: 20 Hz; loading piston: 6-mm-diameter stainless steel) until observing cracks. The data were analyzed by two-way ANOVA, Kaplan–Meier, and Mantel-Cox post hoc tests. Finite element analysis (FEA) and fractographic analyses were performed. Results The fatigue performance of LD and RC occlusal veneers was evaluated based on different prosthetic preparation cusp inclinations. The 0° inclination showed the best fatigue performance for both materials (LD: 944N, RC: 861N), while the 15° and 30° inclinations had lower values (LD: 800N and 533N, RC: 739N and 717N, respectively). The study also found that for a 0° inclination, LD occlusal veneers performed better than RC ones (LD: 944 N > RC: 861N), while for a 30° inclination, RC occlusal veneers had better fatigue performance than LD ones (LD: 533N < RC: 717N). No significant difference was observed between the materials for a 15° inclination (LD: 800N = RC: 739N). The FEA results showed a higher tensile stress concentration on lithium disilicate than on resin composite occlusal veneers. All lithium disilicate occlusal veneers showed radial crack failures, while resin composite occlusal veneers showed Hertzian cone cracks and radial cracks combined. Conclusion Considering mechanical perspective only, RC occlusal veneers should be indicated when prosthetic preparation cusps inclinations are 30°. When 0° prosthetic preparation cusps inclinations are observed, LD occlusal veneers will behave mechanically better. When a 15° cusp inclination is preserved, both restorative materials behave similarly.
- 5 April 2023
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 142, 105819
Adhesion to lithium disilicate glass-ceramics after aging: Resin viscosity and ceramic surface treatment effects
- 5 April 2023
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 142, 105819
Adhesion to lithium disilicate glass-ceramics after aging: Resin viscosity and ceramic surface treatment effects
- 6 February 2023
- Published by Springer Nature in Current Oral Health Reports
- Vol. 10 (1) , 8-13
Do We Still Need Intraradicular Retainers? Current Perspectives on the Treatment of Endodontically Treated Teeth
- 6 February 2023
- Published by Springer Nature in Current Oral Health Reports
- Vol. 10 (1) , 8-13
Do We Still Need Intraradicular Retainers? Current Perspectives on the Treatment of Endodontically Treated Teeth
- 6 December 2022
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 138, 105607
A brief review on fatigue test of ceramic and some related matters in Dentistry
- 6 December 2022
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 138, 105607
A brief review on fatigue test of ceramic and some related matters in Dentistry