Tatsuaki Kanai
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Tatsuaki Kanai has a total of 53 co-authors. Here are the top co-authors by number of shared publications:
Naruhiro Matsufuji
National Institute of Radiological Sciences, National Institutes for Quantum and Radiological Sciences and Technology, Chiba, Japan
4 shared publications- Makoto Sakama
Research Center for Charged Particle Therapy, National Institute of Radiological Sciences, 4-9-1, Anagawa, Inage-ku, Chiba 263-8555, Japan
2 shared publications - Akie Nagao
Department of Electronics and Informatics, Gunma University, Kiryu 376-8515, Gunma, Japan
1 shared publication - Akifumi Fukumura
National Institute of Radiological Sciences, Chiba, Japan
1 shared publication Athena Evalour Paz
Heavy Ion Medicine, Graduate School of Medicine, Gunma University, Gunma, Japan
1 shared publicationEisuke Takase
1 shared publication
Latest Publications
- Open Access
- 25 January 2023
- Published by International Institute of Anticancer Research in Anticancer Research
- Vol. 43 (2) , 581-589
Ultra-high Dose-rate Carbon-ion Scanning Beam With a Compact Medical Synchrotron Contributing to Further Development of FLASH Irradiation
Background/Aim: The focus of this report is establishing an irradiation arrangement to realize an ultra-high dose-rate (uHDR; FLASH) of scanned carbon-ion irradiation possible with a compact commonly available medical synchrotron. Materials and Methods: Following adjustments to the operation it became possible to extract ≥1.0×109 carbon ions at 208.3 MeV/u (86 mm in range) per 100 ms. The design takes the utmost care to prevent damage to monitors, particularly in the nozzle, achieved by the uHDR beam not passing through this part of the apparatus. Doses were adjusted by extraction times, using a function generator. After one scan by the carbon-ion beam it became possible to create a field within the extraction time. The Advanced Markus chamber (AMC) and Gafchromic film are then able to measure the absolute dose and field size at a plateau depth, with the operating voltage of the chamber at 400 V at the uHDR for the AMC. Results: The beam scanning utilizing this uHDR irradiation could be confirmed at a dose of 6.5±0.08 Gy (±3% homogeneous) at this volume over at least 16×16 mm2 corresponding to a dose-rate of 92.3 Gy/s (±1.3%). The dose was ca. 0.7, 1.5, 2.9, and 5.4 Gy depending on dose-rate and field size, with the rate of killed cells increasing with the irradiation dose. Conclusion: The compact medical synchrotron achieved FLASH dose-rates of >40 Gy/s at different dose levels and in useful field sizes for research with the apparatus and arrangement developed here.
- 25 January 2023
- Published by International Institute of Anticancer Research in Anticancer Research
- Vol. 43 (2) , 581-589
Open AccessUltra-high Dose-rate Carbon-ion Scanning Beam With a Compact Medical Synchrotron Contributing to Further Development of FLASH Irradiation
Background/Aim: The focus of this report is establishing an irradiation arrangement to realize an ultra-high dose-rate (uHDR; FLASH) of scanned carbon-ion irradiation possible with a compact commonly available medical synchrotron. Materials and Methods: Following adjustments to the operation it became possible to extract ≥1.0×109 carbon ions at 208.3 MeV/u (86 mm in range) per 100 ms. The design takes the utmost care to prevent damage to monitors, particularly in the nozzle, achieved by the uHDR beam not passing through this part of the apparatus. Doses were adjusted by extraction times, using a function generator. After one scan by the carbon-ion beam it became possible to create a field within the extraction time. The Advanced Markus chamber (AMC) and Gafchromic film are then able to measure the absolute dose and field size at a plateau depth, with the operating voltage of the chamber at 400 V at the uHDR for the AMC. Results: The beam scanning utilizing this uHDR irradiation could be confirmed at a dose of 6.5±0.08 Gy (±3% homogeneous) at this volume over at least 16×16 mm2 corresponding to a dose-rate of 92.3 Gy/s (±1.3%). The dose was ca. 0.7, 1.5, 2.9, and 5.4 Gy depending on dose-rate and field size, with the rate of killed cells increasing with the irradiation dose. Conclusion: The compact medical synchrotron achieved FLASH dose-rates of >40 Gy/s at different dose levels and in useful field sizes for research with the apparatus and arrangement developed here.
- Open Access
Calculation of Stopping-Power Ratio from Multiple CT Numbers Using Photon-Counting CT System: Two- and Three-Parameter-Fitting Method
The two-parameter-fitting method (PFM) is commonly used to calculate the stopping-power ratio (SPR). This study proposes a new formalism: a three-PFM, which can be used in multiple spectral computed tomography (CT). Using a photon-counting CT system, seven rod-shaped samples of aluminium, graphite, and poly(methyl methacrylate) (PMMA), and four types of biological phantom materials were placed in a water-filled sample holder. The X-ray tube voltage and current were set at 150 kV and 40 μA respectively, and four CT images were obtained at four threshold settings. A semi-empirical correction method that corrects the difference between the CT values from the photon-counting CT images and theoretical values in each spectral region was also introduced. Both the two- and three-PFMs were used to calculate the effective atomic number and electron density from multiple CT numbers. The mean excitation energy was calculated via parameterisation with the effective atomic number, and the SPR was then calculated from the calculated electron density and mean excitation energy. Then, the SPRs from both methods were compared with the theoretical values. To estimate the noise level of the CT numbers obtained from the photon-counting CT, CT numbers, including noise, were simulated to evaluate the robustness of the aforementioned PFMs. For the aluminium and graphite, the maximum relative errors for the SPRs calculated using the two-PFM and three-PFM were 17.1% and 7.1%, respectively. For the PMMA and biological phantom materials, the maximum relative errors for the SPRs calculated using the two-PFM and three-PFM were 5.5% and 2.0%, respectively. It was concluded that the three-PFM, compared with the two-PFM, can yield SPRs that are closer to the theoretical values and is less affected by noise.Open AccessCalculation of Stopping-Power Ratio from Multiple CT Numbers Using Photon-Counting CT System: Two- and Three-Parameter-Fitting Method
The two-parameter-fitting method (PFM) is commonly used to calculate the stopping-power ratio (SPR). This study proposes a new formalism: a three-PFM, which can be used in multiple spectral computed tomography (CT). Using a photon-counting CT system, seven rod-shaped samples of aluminium, graphite, and poly(methyl methacrylate) (PMMA), and four types of biological phantom materials were placed in a water-filled sample holder. The X-ray tube voltage and current were set at 150 kV and 40 μA respectively, and four CT images were obtained at four threshold settings. A semi-empirical correction method that corrects the difference between the CT values from the photon-counting CT images and theoretical values in each spectral region was also introduced. Both the two- and three-PFMs were used to calculate the effective atomic number and electron density from multiple CT numbers. The mean excitation energy was calculated via parameterisation with the effective atomic number, and the SPR was then calculated from the calculated electron density and mean excitation energy. Then, the SPRs from both methods were compared with the theoretical values. To estimate the noise level of the CT numbers obtained from the photon-counting CT, CT numbers, including noise, were simulated to evaluate the robustness of the aforementioned PFMs. For the aluminium and graphite, the maximum relative errors for the SPRs calculated using the two-PFM and three-PFM were 17.1% and 7.1%, respectively. For the PMMA and biological phantom materials, the maximum relative errors for the SPRs calculated using the two-PFM and three-PFM were 5.5% and 2.0%, respectively. It was concluded that the three-PFM, compared with the two-PFM, can yield SPRs that are closer to the theoretical values and is less affected by noise. - Open Access
- 1 December 2018
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 102 (5) , 1551-1559
Tumor Control Probability Analysis for Single-Fraction Carbon-Ion Radiation Therapy of Early-Stage Non-small Cell Lung Cancer
- 1 December 2018
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 102 (5) , 1551-1559
Open AccessTumor Control Probability Analysis for Single-Fraction Carbon-Ion Radiation Therapy of Early-Stage Non-small Cell Lung Cancer
- 1 January 2009
- Vol. 28 (4) , 132-41
Verification of biological dose calculation for carbon ion therapy with a monte carlo method.
We developed a calculation technique to evaluate the biological dose distribution of heavy ion beams, and verified its reliability by comparison with experimental results. The calculation technique was developed by connecting two general-purpose Monte Carlo codes. In order to evaluate the radiation quality and biological effect, the microdosimetric kinetic model was adopted. We estimated the distribution of physical dose and radiation quality for the carbon broad beam with experiments and with Monte Carlo calculations. Relative biological effectiveness (RBE) was estimated from radiation quality, and biological dose could be calculated as the product of the physical dose and the RBE. Our calculations showed good agreement with experiments, not only for the physical dose, but also for the dose-averaged lineal energy as an expression of radiation quality and therefore biological dose. This finding indicates that our calculation tool will be useful to estimate biological dose distribution in the design of heavy ion radiation facilities or for quality assurance in treatment planning.
- 1 January 2009
- Vol. 28 (4) , 132-41
Verification of biological dose calculation for carbon ion therapy with a monte carlo method.
We developed a calculation technique to evaluate the biological dose distribution of heavy ion beams, and verified its reliability by comparison with experimental results. The calculation technique was developed by connecting two general-purpose Monte Carlo codes. In order to evaluate the radiation quality and biological effect, the microdosimetric kinetic model was adopted. We estimated the distribution of physical dose and radiation quality for the carbon broad beam with experiments and with Monte Carlo calculations. Relative biological effectiveness (RBE) was estimated from radiation quality, and biological dose could be calculated as the product of the physical dose and the RBE. Our calculations showed good agreement with experiments, not only for the physical dose, but also for the dose-averaged lineal energy as an expression of radiation quality and therefore biological dose. This finding indicates that our calculation tool will be useful to estimate biological dose distribution in the design of heavy ion radiation facilities or for quality assurance in treatment planning.
- 1 January 2009
- Vol. 28 (4) , 172-206
Research on radiation protection in the application of new technologies for proton and heavy ion radiotherapy.
Particle radiotherapy using proton and heavy ion beams has shown improved clinical results and is a promising cancer therapy which is expected to gradually spread in Japan. There are, however, no special regulations for radiotherapy treatment facilities. They have been operated under the same safety regulations as for a research facility using a research accelerator. Significantly high-energy radiation is necessary for particle radiotherapy compared with conventional radiation therapy. The treatment facility, therefore, should have a large accelerator, which is installed in a room with a thick shield wall. Data on radiation protection for such high energy medical facilities is fragmentary and insufficient. In this study, we examined the necessity of other regulations for the safe operation of medical facilities for particle radiotherapy. First, we measured activation levels of the therapeutic devices and of patients. Next the safety level of the medical facility was evaluated from the viewpoint of radiation protection. We have confirmed the facilities can be safely operated by present regulations given in the Law Concerning Prevention from Radiation Hazards due to Radiation Isotopes, etc. or the Law for Health Protection and Medical Care.
- 1 January 2009
- Vol. 28 (4) , 172-206
Research on radiation protection in the application of new technologies for proton and heavy ion radiotherapy.
Particle radiotherapy using proton and heavy ion beams has shown improved clinical results and is a promising cancer therapy which is expected to gradually spread in Japan. There are, however, no special regulations for radiotherapy treatment facilities. They have been operated under the same safety regulations as for a research facility using a research accelerator. Significantly high-energy radiation is necessary for particle radiotherapy compared with conventional radiation therapy. The treatment facility, therefore, should have a large accelerator, which is installed in a room with a thick shield wall. Data on radiation protection for such high energy medical facilities is fragmentary and insufficient. In this study, we examined the necessity of other regulations for the safe operation of medical facilities for particle radiotherapy. First, we measured activation levels of the therapeutic devices and of patients. Next the safety level of the medical facility was evaluated from the viewpoint of radiation protection. We have confirmed the facilities can be safely operated by present regulations given in the Law Concerning Prevention from Radiation Hazards due to Radiation Isotopes, etc. or the Law for Health Protection and Medical Care.
- 1 January 2009
- Vol. 29 (1) , 12-9
[Field-size Dependence of the Glass Dosimeter in 6 MV Photon Beams].
The postal dose audit using radio-photoluminescence glass dosimeters was begun in November 2007 in order to improve the quality of radiotherapy in Japan. However, the irradiation conditions are now limited to the reference conditions which are 10×10 cm(2) field and 10 cm depth. The application of the glass dosimeters to non-reference conditions is strongly desired. This study dealt with the field-size dependence of the glass dosimeter outputs in the 6 MV photon beams of a medical linear accelerator (Varian Clinac21EX). We irradiated glass dosimeters with square field sizes of 5, 7, 10, 13, 16, 20, 23 and 25 cm side lengths at the 10 cm depth of the water equivalent phantom (SSD=90 cm). The outputs were compared with ionization chamber outputs. The ratio of the glass dosimeter outputs to the absorbed dose to water obtained with the ionization chamber increased approximately 1.5% between 5×5 cm(2) and 25×25 cm(2). We have to consider this field-size dependence when we apply the glass dosimeters to non-reference conditions.
- 1 January 2009
- Vol. 29 (1) , 12-9
[Field-size Dependence of the Glass Dosimeter in 6 MV Photon Beams].
The postal dose audit using radio-photoluminescence glass dosimeters was begun in November 2007 in order to improve the quality of radiotherapy in Japan. However, the irradiation conditions are now limited to the reference conditions which are 10×10 cm(2) field and 10 cm depth. The application of the glass dosimeters to non-reference conditions is strongly desired. This study dealt with the field-size dependence of the glass dosimeter outputs in the 6 MV photon beams of a medical linear accelerator (Varian Clinac21EX). We irradiated glass dosimeters with square field sizes of 5, 7, 10, 13, 16, 20, 23 and 25 cm side lengths at the 10 cm depth of the water equivalent phantom (SSD=90 cm). The outputs were compared with ionization chamber outputs. The ratio of the glass dosimeter outputs to the absorbed dose to water obtained with the ionization chamber increased approximately 1.5% between 5×5 cm(2) and 25×25 cm(2). We have to consider this field-size dependence when we apply the glass dosimeters to non-reference conditions.
- 1 January 2008
- Vol. 28 (1) , 1-14
Development of a portable graphite calorimeter for radiation dosimetry.
We developed and performance-tested a portable graphite calorimeter designed to measure the absolute dosimetry of various beams including heavy-ion beams, based on a flexible and convenient means of measurement. This measurement system is fully remote-controlled by the GPIB system. This system uses a digital PID (Proportional, Integral, Derivative) control method based on the LabVIEW software. It was possible to attain stable conditions in a shorter time by this system. The standard deviation of the measurements using the calorimeter was 0.79% at a dose rate of 0.8 Gy/min in 17 calorimeter runs for a (60)Co photon beam. The overall uncertainties for the absorbed dose to graphite and water of the (60)Co photon beam using the developed calorimeter were 0.89% and 1.35%, respectively. Estimations of the correction factors due to vacuum gaps, impurities in the core, the dose gradient and the radiation profile were included in the uncertainties. The absorbed doses to graphite and water irradiated by the (60)Co photon beam were compared with dosimetry measurements obtained using three ionization chambers. The absorbed doses to graphite and water estimated by the two dosimetry methods agreed within 0.1% and 0.3%, respectively.
- 1 January 2008
- Vol. 28 (1) , 1-14
Development of a portable graphite calorimeter for radiation dosimetry.
We developed and performance-tested a portable graphite calorimeter designed to measure the absolute dosimetry of various beams including heavy-ion beams, based on a flexible and convenient means of measurement. This measurement system is fully remote-controlled by the GPIB system. This system uses a digital PID (Proportional, Integral, Derivative) control method based on the LabVIEW software. It was possible to attain stable conditions in a shorter time by this system. The standard deviation of the measurements using the calorimeter was 0.79% at a dose rate of 0.8 Gy/min in 17 calorimeter runs for a (60)Co photon beam. The overall uncertainties for the absorbed dose to graphite and water of the (60)Co photon beam using the developed calorimeter were 0.89% and 1.35%, respectively. Estimations of the correction factors due to vacuum gaps, impurities in the core, the dose gradient and the radiation profile were included in the uncertainties. The absorbed doses to graphite and water irradiated by the (60)Co photon beam were compared with dosimetry measurements obtained using three ionization chambers. The absorbed doses to graphite and water estimated by the two dosimetry methods agreed within 0.1% and 0.3%, respectively.
- 1 January 2000
- Vol. 20 (2) , 71-82
[Fundamental Study on Heavy Ion CT Using Pencil Beam Scanning Method]
The feasibility of heavy ion computed tomography was investigated. A cylindrical polyethylene sample of 50 mm in diameter was used to establish the pencil beam scanning method and estimate the performance of the system. The sample was irradiated with carbon ions of 290 MeV/u and 400 MeV/u, and helium ions of 150 MeV/u. The residual beam energy was measured by a BGO scintillator in coincidence with two small plastic scintillators placed in front of and behind the sample to restrict the beam path and improve the spatial resolution in the CT reconstruction. The projection data were obtained by moving the sample only in the transverse direction because of its symmetrical structure. A Lucite sample with many holes of different diameters was used to demonstrate the spatial resolution of this CT system. From the reconstructed images the spatial resolution was estimated to be less than 2 mm under the conditions in this work. The electron density ratios of ethyl alcohol, water, and Lucite to polyethylene were obtained, which are in good agreement with the calculated values.
- 1 January 2000
- Vol. 20 (2) , 71-82
[Fundamental Study on Heavy Ion CT Using Pencil Beam Scanning Method]
The feasibility of heavy ion computed tomography was investigated. A cylindrical polyethylene sample of 50 mm in diameter was used to establish the pencil beam scanning method and estimate the performance of the system. The sample was irradiated with carbon ions of 290 MeV/u and 400 MeV/u, and helium ions of 150 MeV/u. The residual beam energy was measured by a BGO scintillator in coincidence with two small plastic scintillators placed in front of and behind the sample to restrict the beam path and improve the spatial resolution in the CT reconstruction. The projection data were obtained by moving the sample only in the transverse direction because of its symmetrical structure. A Lucite sample with many holes of different diameters was used to demonstrate the spatial resolution of this CT system. From the reconstructed images the spatial resolution was estimated to be less than 2 mm under the conditions in this work. The electron density ratios of ethyl alcohol, water, and Lucite to polyethylene were obtained, which are in good agreement with the calculated values.